Jong-Sup Park
Research Subjects
Jong-Sup Park has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Hee Beom Park
Department of Highway & Transportation Research, Korea Institute of Civil Engineering and Building Technology, Goyang-Si 10223, Republic of Korea
2 shared publications - Woo-Tai Jung
Korea Institute of Civil Engineering and Building Technology, Goyang-Si 10223, Republic of Korea
2 shared publications Jae-Yoon Kang
1 shared publication- Jae-Yoon Kang
Department of Infrastructure Safety Research
1 shared publication - Sanghyun Kim
Department of Environmental Engineering, Pusan National University, Busan, South Korea
1 shared publication
Latest Publications
- 30 December 2020
- Published by Korean Society for Advanced Composite Structures in Journal of the Korean Society for Advanced Composite Structures
- Vol. 11 (6) , 71-77
Reinforced Concrete Beams Strengthened with an Unbonded and Prestressed Near Surface Mounted Tendon
- 30 December 2020
- Published by Korean Society for Advanced Composite Structures in Journal of the Korean Society for Advanced Composite Structures
- Vol. 11 (6) , 71-77
Reinforced Concrete Beams Strengthened with an Unbonded and Prestressed Near Surface Mounted Tendon
- Open Access
- 1 January 2018
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2018 (1)
Strengthening Effect of Prestressed Near‐Surface‐Mounted CFRP Tendon on Reinforced Concrete Beam
Efforts are being made to use FRP (fiber‐reinforced polymer) for reinforcements instead of traditional construction materials like steel owing to its remarkable mechanical properties. Among them, this study developed a CFRP tendon to be used as near‐surface‐mounted reinforcement together with a dedicated prestressing system and investigates experimentally the strengthening effect considering various variables including the amount of reinforcement, the bond performance, and the strength and damage ratio of the concrete. The test results reveal that one line of reinforcement improved the strengthening performance by about 55% and two lines by 96% and that the bonding of the CFRP tendon enhanced the strengthening performance by 15%. Higher strength and damage of the concrete seem to have a poor effect on the overall strengthening performance. However, the use of CFRP tendon with bond performance higher than 11 MPa, filler, and anchorage system appears to promote stable strengthening behavior.
- 1 January 2018
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2018 (1)
Open AccessStrengthening Effect of Prestressed Near‐Surface‐Mounted CFRP Tendon on Reinforced Concrete Beam
Efforts are being made to use FRP (fiber‐reinforced polymer) for reinforcements instead of traditional construction materials like steel owing to its remarkable mechanical properties. Among them, this study developed a CFRP tendon to be used as near‐surface‐mounted reinforcement together with a dedicated prestressing system and investigates experimentally the strengthening effect considering various variables including the amount of reinforcement, the bond performance, and the strength and damage ratio of the concrete. The test results reveal that one line of reinforcement improved the strengthening performance by about 55% and two lines by 96% and that the bonding of the CFRP tendon enhanced the strengthening performance by 15%. Higher strength and damage of the concrete seem to have a poor effect on the overall strengthening performance. However, the use of CFRP tendon with bond performance higher than 11 MPa, filler, and anchorage system appears to promote stable strengthening behavior.