Nae-Hyun Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nae-Hyun Kim has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Cheol-Hwan Kim
Department of Mechanical Engineering, Incheon National University, Incheon, Korea
3 shared publicationsMin-Geon Go
R&D Center, Samhwa-Ace Co, Incheon, Republic of Korea
3 shared publicationsIl-Hwan Choi
Department of Mechanical Engineering, Incheon National University, Incheon, Korea
2 shared publicationsYousaf Shah
Department of Mechanical Engineering, Incheon National University, Incheon, Korea
2 shared publicationsByung-Nam Choi
R&D Center, Samhwa-Ace Co, Incheon, Republic of Korea
1 shared publication- Chuancai Zhang
Qingdao University of Science and Technology College of Electromechanical Engineering 99, Songling Road, Qingdao City 266061 , China
1 shared publication
Latest Publications
- 3 January 2022
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 36 (1) , 467-478
Pool boiling of R-123/MO and R-134a/POE lubricant mixtures on pored surfaces
- 3 January 2022
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 36 (1) , 467-478
Pool boiling of R-123/MO and R-134a/POE lubricant mixtures on pored surfaces
- 31 October 2021
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 35 (11) , 5225-5232
Thermo-hydraulic characteristics of heat exchangers having the smooth or the herringbone wave fins on 12.7 mm tubes under dehumidifying condition
- 31 October 2021
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 35 (11) , 5225-5232
Thermo-hydraulic characteristics of heat exchangers having the smooth or the herringbone wave fins on 12.7 mm tubes under dehumidifying condition
- 22 September 2021
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 35 (10) , 4747-4756
Comparison of the heat transfer and pressure drop characteristics of fin-and-tube heat exchangers having smooth or herringbone wave fins on 12.7 mm outer diameter tubes
- 22 September 2021
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 35 (10) , 4747-4756
Comparison of the heat transfer and pressure drop characteristics of fin-and-tube heat exchangers having smooth or herringbone wave fins on 12.7 mm outer diameter tubes
- 18 September 2021
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 58 (4) , 587-600
Two-phase refrigerant distribution for a horizontal header/horizontal mini-channel tube configuration
- 18 September 2021
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 58 (4) , 587-600
Two-phase refrigerant distribution for a horizontal header/horizontal mini-channel tube configuration
- 28 August 2021
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 35 (9) , 4225-4237
Refrigerant distribution in an evaporator having a horizontal header and horizontal mini-channel tubes
- 28 August 2021
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 35 (9) , 4225-4237
Refrigerant distribution in an evaporator having a horizontal header and horizontal mini-channel tubes
- 2 June 2021
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 35 (5) , 674-687
Experiments on heat and mass transfer in enthalpy exchangers having a diagonal configuration
In this study, with an aim to develop a proper effectiveness-NTU relationship of an enthalpy exchanger having a diagonal flow configuration, heat and moisture transfer experiments were conducted. Test samples having a range of diagonal angles were tested, and the effectiveness ratios between the diagonal flow and the cross-flow configuration were obtained as a function of the diagonal angle. Developed correlations of the heat, moisture, and enthalpy predicted the data within 3%. Furthermore, it was shown that the moisture transfer effectiveness was highly dependent on the relative humidity and the air temperature.- 2 June 2021
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 35 (5) , 674-687
Experiments on heat and mass transfer in enthalpy exchangers having a diagonal configuration
In this study, with an aim to develop a proper effectiveness-NTU relationship of an enthalpy exchanger having a diagonal flow configuration, heat and moisture transfer experiments were conducted. Test samples having a range of diagonal angles were tested, and the effectiveness ratios between the diagonal flow and the cross-flow configuration were obtained as a function of the diagonal angle. Developed correlations of the heat, moisture, and enthalpy predicted the data within 3%. Furthermore, it was shown that the moisture transfer effectiveness was highly dependent on the relative humidity and the air temperature.- 13 April 2021
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 35 (4) , 484-499
Experimental investigation on the airside heat transfer and pressure drop of the fin-and-tube heat exchangers having oval tubes
It is well known that the replacement of round tubes to oval tubes in a fin-and-tube heat exchanger reduces the air-side pressure drop as well as the low-performance region behind the tube, which improves the thermal performance of the heat exchanger. However, experimental evidences are lacking, especially for generic heat exchangers. In this study, generic heat exchangers having oval tubes were tested, which included two different oval tube dimension and two different tube pitches. Round tube samples were also tested for a comparison purpose. The effect of fin pitch on j factor was negligible, whereas f factor increased as the fin pitch increased. Furthermore, both the j and f factor decreased as the number of tube row increased. A thermal performance comparison based on the ratio of thermal conductance per unit volume ( ) to pressure drop per unit length ( ) revealed that the oval tube samples yielded a higher performance than the round tube samples, except at a small number of tube row. Furthermore, the best performance was obtained from the oval tube samples having a smaller diameter tube. On the other hand, relatively poor performance was obtained from the oval tube samples having a larger diameter tube, probably due to the large pressure drops. The j and f correlations were developed based on the data.- 13 April 2021
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 35 (4) , 484-499
Experimental investigation on the airside heat transfer and pressure drop of the fin-and-tube heat exchangers having oval tubes
It is well known that the replacement of round tubes to oval tubes in a fin-and-tube heat exchanger reduces the air-side pressure drop as well as the low-performance region behind the tube, which improves the thermal performance of the heat exchanger. However, experimental evidences are lacking, especially for generic heat exchangers. In this study, generic heat exchangers having oval tubes were tested, which included two different oval tube dimension and two different tube pitches. Round tube samples were also tested for a comparison purpose. The effect of fin pitch on j factor was negligible, whereas f factor increased as the fin pitch increased. Furthermore, both the j and f factor decreased as the number of tube row increased. A thermal performance comparison based on the ratio of thermal conductance per unit volume ( ) to pressure drop per unit length ( ) revealed that the oval tube samples yielded a higher performance than the round tube samples, except at a small number of tube row. Furthermore, the best performance was obtained from the oval tube samples having a smaller diameter tube. On the other hand, relatively poor performance was obtained from the oval tube samples having a larger diameter tube, probably due to the large pressure drops. The j and f correlations were developed based on the data.- 21 March 2021
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 57 (10) , 1633-1644
Air-side heat transfer and pressure drop of the fin-and-tube heat exchangers having oval tubes under wet condition
- 21 March 2021
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 57 (10) , 1633-1644
Air-side heat transfer and pressure drop of the fin-and-tube heat exchangers having oval tubes under wet condition
- 1 January 2021
- Published by Japan Society of Mechanical Engineers in Journal of Thermal Science and Technology
- Vol. 16 (2) , JTST0031
Effects of fin corrugation and tube geometry on the airside performance of fin-and-tube heat exchangers - Part I; dry surface
For a cooling or heating coil of a building air conditioning system, large diameter tubes (over 12.7 mm) with wave fins are frequently used. Furthermore, there have been attempts to apply oval tubes to the heating or cooling coils. In this study, nine samples - three herringbone wave fin/round tube, three smooth wave fin/round tube and three smooth wave fin/oval tube samples - were tested under dry condition. All of the samples had the same original tube diameter (12.7 mm). For the smooth wave fin samples, fins were identical, and for the round tube samples, fin corrugation angles were almost the same. Tests were conducted varying the frontal air velocity from 1.0 to 4.0 m/s. Results showed that the round tube samples yielded higher conductance per volume (ηo ho Ao / Vo ) than the oval tube sample. Similarly, the smooth wave fin samples yielded a higher conductance per volume than the herringbone wave fin samples. At one row configuration, however, a significant difference among samples existed between the heat transfer conductance per volume and the heat transfer coefficient, and the reason was explained by the difference in fin efficiency between the round and the oval geometry. The pressure drops of the round tube samples were larger than those of the oval tube samples. Similarly, the smooth wave fin samples yielded larger pressure drops than the herringbone wave fin samples. A performance evaluation revealed that the smooth wave fin samples yielded larger heat transfer conductances per volume than the herringbone wave fin samples at the same pumping power per volume.
- 1 January 2021
- Published by Japan Society of Mechanical Engineers in Journal of Thermal Science and Technology
- Vol. 16 (2) , JTST0031
Effects of fin corrugation and tube geometry on the airside performance of fin-and-tube heat exchangers - Part I; dry surface
For a cooling or heating coil of a building air conditioning system, large diameter tubes (over 12.7 mm) with wave fins are frequently used. Furthermore, there have been attempts to apply oval tubes to the heating or cooling coils. In this study, nine samples - three herringbone wave fin/round tube, three smooth wave fin/round tube and three smooth wave fin/oval tube samples - were tested under dry condition. All of the samples had the same original tube diameter (12.7 mm). For the smooth wave fin samples, fins were identical, and for the round tube samples, fin corrugation angles were almost the same. Tests were conducted varying the frontal air velocity from 1.0 to 4.0 m/s. Results showed that the round tube samples yielded higher conductance per volume (ηo ho Ao / Vo ) than the oval tube sample. Similarly, the smooth wave fin samples yielded a higher conductance per volume than the herringbone wave fin samples. At one row configuration, however, a significant difference among samples existed between the heat transfer conductance per volume and the heat transfer coefficient, and the reason was explained by the difference in fin efficiency between the round and the oval geometry. The pressure drops of the round tube samples were larger than those of the oval tube samples. Similarly, the smooth wave fin samples yielded larger pressure drops than the herringbone wave fin samples. A performance evaluation revealed that the smooth wave fin samples yielded larger heat transfer conductances per volume than the herringbone wave fin samples at the same pumping power per volume.
- 1 January 2021
- Published by Japan Society of Mechanical Engineers in Journal of Thermal Science and Technology
- Vol. 16 (2) , JTST0020
Airside heat transfer and pressure drop of an aluminum heat exchanger having a new louver fin with leading edge extension
Conventional louver fins have an inherent problem of condensate drainage. In this study, a newly developed louver fin is introduced. The louver fin has an extension at leading edge. Dry and wet surface heat transfer and pressure drop characteristics of the heat exchanger made of the new fins were investigated, and results are compared with those having trailing edge extension fins or conventional fins. For conventional sample, significant differences between dry and wet j and f factors were observed. Dry j factors were 166% larger than wet j factors, and wet f factors were 68% larger than dry f factors. The discrepancies were significantly reduced for the samples having extensions, which suggests that extensions are effective in condensate control. The present sample having leading edge extension yielded higher dry j factors than the sample having trailing edge extension, probably due to proper allocation of louvers. Wet j factors of the two extended samples were approximately the same, which means that the condensate drainage is better for trailing edge extension than leading edge extension. Under dry condition, j/f1/3 of leading edge sample were 132 % and 59% higher than those of trailing edge extension and conventional sample respectively. However, under wet condition, j/f1/3 of leading edge extension sample were 87% and 205% higher than those of trailing edge extension and conventional sample. This confirms that the present leading edge extension sample shows better performance than trailing edge extension sample, both under dry and wet condition.
- 1 January 2021
- Published by Japan Society of Mechanical Engineers in Journal of Thermal Science and Technology
- Vol. 16 (2) , JTST0020
Airside heat transfer and pressure drop of an aluminum heat exchanger having a new louver fin with leading edge extension
Conventional louver fins have an inherent problem of condensate drainage. In this study, a newly developed louver fin is introduced. The louver fin has an extension at leading edge. Dry and wet surface heat transfer and pressure drop characteristics of the heat exchanger made of the new fins were investigated, and results are compared with those having trailing edge extension fins or conventional fins. For conventional sample, significant differences between dry and wet j and f factors were observed. Dry j factors were 166% larger than wet j factors, and wet f factors were 68% larger than dry f factors. The discrepancies were significantly reduced for the samples having extensions, which suggests that extensions are effective in condensate control. The present sample having leading edge extension yielded higher dry j factors than the sample having trailing edge extension, probably due to proper allocation of louvers. Wet j factors of the two extended samples were approximately the same, which means that the condensate drainage is better for trailing edge extension than leading edge extension. Under dry condition, j/f1/3 of leading edge sample were 132 % and 59% higher than those of trailing edge extension and conventional sample respectively. However, under wet condition, j/f1/3 of leading edge extension sample were 87% and 205% higher than those of trailing edge extension and conventional sample. This confirms that the present leading edge extension sample shows better performance than trailing edge extension sample, both under dry and wet condition.