Bart De Keulenaer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bart De Keulenaer has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Adrian Regli
Intensive Care Unit, SJOG Murdoch Hospital, Murdoch, WA, Australia; Intensive Care Unit, Fiona Stanley Hospital, Murdoch, WA, Australia; Division of Emergency Medicine, Anaesthesia and Pain Medicine, Medical School, The University of Western Australia, Nedlands, WA, Australia; Medical School, The University of Notre Dame, Fremantle, WA, Australia
1 shared publication Alexander Robinson
Emergency Department, Royal Perth Hospital, Perth, Western Australia, Australia
1 shared publication- Bhajan Singh
Western Australian Sleep Disorders Research Institute, Sir Charles Gairdner Hospital Nedlands Western Australia Australia
1 shared publication - Bill Noffsinger
Department of Pulmonary Physiology and Sleep Medicine, Sir Charles Gairdner Hospital, Hospital Avenue, 6009 Nedlands, Australia
1 shared publication - Brigit Roberts
Sir Charles Gairdner Hospital, Perth, WA, Australia
1 shared publication - Edward Thomas Hamilton Fysh
Centre for Innovative Pleural Research & Department of Respiratory Medicine Sir Charles Gairdner Hospital Nedlands Western Australia Australia
1 shared publication
Latest Publications
- 16 June 2021
- Published by BMJ in BMJ Case Reports
- Vol. 14 (6) , e239811
Unusual presentation of infective endocarditis in ICU
Bacterial endocarditis remains a challenging condition to manage owing to its variety of different presentations. This report describes a 55-year-old woman with endocarditis who presented confused with shoulder and back pain. Initial diagnosis was made difficult by a negative echocardiogram but aided by striking peripheral stigmata. She was treated for infective endocarditis as she met all five Duke’s minor criteria for infective endocarditis. Gallium scan was a useful investigation in identifying lumbar spine and acromioclavicular joint septic foci. This case highlights the challenges of diagnosing endocarditis. It also describes how gallium scans can be useful in identifying occult septic emboli in these patients.
- 16 June 2021
- Published by BMJ in BMJ Case Reports
- Vol. 14 (6) , e239811
Unusual presentation of infective endocarditis in ICU
Bacterial endocarditis remains a challenging condition to manage owing to its variety of different presentations. This report describes a 55-year-old woman with endocarditis who presented confused with shoulder and back pain. Initial diagnosis was made difficult by a negative echocardiogram but aided by striking peripheral stigmata. She was treated for infective endocarditis as she met all five Duke’s minor criteria for infective endocarditis. Gallium scan was a useful investigation in identifying lumbar spine and acromioclavicular joint septic foci. This case highlights the challenges of diagnosing endocarditis. It also describes how gallium scans can be useful in identifying occult septic emboli in these patients.
- Open Access
- 26 October 2012
- Published by Springer Nature in Critical Care
- Vol. 16 (5) , R208
Matching positive end-expiratory pressure to intra-abdominal pressure improves oxygenation in a porcine sick lung model of intra-abdominal hypertension
Introduction: Intra-abdominal hypertension (IAH) causes atelectasis, reduces lung volumes and increases respiratory system elastance. Positive end-expiratory pressure (PEEP) in the setting of IAH and healthy lungs improves lung volumes but not oxygenation. However, critically ill patients with IAH often suffer from acute lung injury (ALI). This study, therefore, examined the respiratory and cardiac effects of positive end-expiratory pressure in an animal model of IAH, with sick lungs. Methods: Nine pigs were anesthetized and ventilated (48 +/- 6 kg). Lung injury was induced with oleic acid. Three levels of intra-abdominal pressure (baseline, 18, and 22 mmHg) were randomly generated. At each level of intra-abdominal pressure, three levels of PEEP were randomly applied: baseline (5 cmH2O), moderate (0.5 × intra-abdominal pressure), and high (1.0 × intra-abdominal pressure). We measured end-expiratory lung volumes, arterial oxygen levels, respiratory mechanics, and cardiac output 10 minutes after each new IAP and PEEP setting. Results: At baseline PEEP, IAH (22 mmHg) decreased oxygen levels (-55%, P P = 0.007). At IAP of 22 mmHg, moderate and high PEEP increased oxygen levels (+60%, P = 0.04 and +162%, P P = 0.02 and +279%, P P = 0.04). Shunt and dead-space fraction inversely correlated with oxygen levels and end-expiratory lung volumes. In the presence of IAH, lung, chest wall and respiratory system elastance increased. Subsequently, PEEP decreased respiratory system elastance by decreasing chest wall elastance. Conclusions: In a porcine sick lung model of IAH, PEEP matched to intra-abdominal pressure led to increased lung volumes and oxygenation and decreased chest wall elastance shunt and dead-space fraction. High PEEP decreased cardiac output. The study shows that lung injury influences the effects of IAH and PEEP on oxygenation and respiratory mechanics. Our findings support the application of PEEP in the setting of acute lung injury and IAH.
- 26 October 2012
- Published by Springer Nature in Critical Care
- Vol. 16 (5) , R208
Open AccessMatching positive end-expiratory pressure to intra-abdominal pressure improves oxygenation in a porcine sick lung model of intra-abdominal hypertension
Introduction: Intra-abdominal hypertension (IAH) causes atelectasis, reduces lung volumes and increases respiratory system elastance. Positive end-expiratory pressure (PEEP) in the setting of IAH and healthy lungs improves lung volumes but not oxygenation. However, critically ill patients with IAH often suffer from acute lung injury (ALI). This study, therefore, examined the respiratory and cardiac effects of positive end-expiratory pressure in an animal model of IAH, with sick lungs. Methods: Nine pigs were anesthetized and ventilated (48 +/- 6 kg). Lung injury was induced with oleic acid. Three levels of intra-abdominal pressure (baseline, 18, and 22 mmHg) were randomly generated. At each level of intra-abdominal pressure, three levels of PEEP were randomly applied: baseline (5 cmH2O), moderate (0.5 × intra-abdominal pressure), and high (1.0 × intra-abdominal pressure). We measured end-expiratory lung volumes, arterial oxygen levels, respiratory mechanics, and cardiac output 10 minutes after each new IAP and PEEP setting. Results: At baseline PEEP, IAH (22 mmHg) decreased oxygen levels (-55%, P P = 0.007). At IAP of 22 mmHg, moderate and high PEEP increased oxygen levels (+60%, P = 0.04 and +162%, P P = 0.02 and +279%, P P = 0.04). Shunt and dead-space fraction inversely correlated with oxygen levels and end-expiratory lung volumes. In the presence of IAH, lung, chest wall and respiratory system elastance increased. Subsequently, PEEP decreased respiratory system elastance by decreasing chest wall elastance. Conclusions: In a porcine sick lung model of IAH, PEEP matched to intra-abdominal pressure led to increased lung volumes and oxygenation and decreased chest wall elastance shunt and dead-space fraction. High PEEP decreased cardiac output. The study shows that lung injury influences the effects of IAH and PEEP on oxygenation and respiratory mechanics. Our findings support the application of PEEP in the setting of acute lung injury and IAH.