Hui Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hui Cheng has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Hao Yu
Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
15 shared publications Ming Zheng
6 shared publicationsXiu-Rong Li
4 shared publicationsXiurong Li
Department of Prosthetic Technology, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, China
4 shared publications- Chang-Yuan Zhang
Department of Prosthodontics, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, PR China
3 shared publications Honglei Lin
Institute of Stomatology & Research Center of Dental Esthetics and Biomechanics, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, China
3 shared publications
Latest Publications
- Open Access
- 15 September 2023
- Published by Wiley in Journal of Dental Education
- Vol. 87 (12) , 1636-1644
The evaluation of online Modified Objective Structured Examination (MOSE) as postgraduate admissions re‐examination: A report from Fujian Medical University, China
This paper aims to explore the successful implementation of online postgraduate admissions re-examination in China, specifically focusing on the Modified Objective Structured Examination (MOSE). It introduced the specific practice of the online postgraduate admissions re-examination in China and investigated the perceptions of applicants, postgraduate supervisors and admissions staffs about the online MOSE re-examination. Surveys were administrated 3 years after the implementation of online MOSE postgraduate admissions re-examination in China. Separate surveys were conducted with applicants, postgraduate supervisors, and admissions staff members to gather their opinions and suggestions regarding the online MOSE re-examination. A total of 65 applicants, 43 postgraduate supervisors and seven admissions staff members completed the surveys. Over 80% of the applicants agreed that the online MOSE comprehensively evaluated their medical humanities, communication, medical knowledge, and overall competence. Furthermore, 89.30% of postgraduate supervisors believed that the students recruited through online MOSE were either "not significantly different," "better," or "much better" compared to those recruited through on-site re-examination. Admissions staff members also expressed a favorable view of online MOSE re-examination. The online MOSE re-examination is an effective, convenient, and affirmative evaluation method for postgraduate admissions re-examination.
- 15 September 2023
- Published by Wiley in Journal of Dental Education
- Vol. 87 (12) , 1636-1644
Open AccessThe evaluation of online Modified Objective Structured Examination (MOSE) as postgraduate admissions re‐examination: A report from Fujian Medical University, China
This paper aims to explore the successful implementation of online postgraduate admissions re-examination in China, specifically focusing on the Modified Objective Structured Examination (MOSE). It introduced the specific practice of the online postgraduate admissions re-examination in China and investigated the perceptions of applicants, postgraduate supervisors and admissions staffs about the online MOSE re-examination. Surveys were administrated 3 years after the implementation of online MOSE postgraduate admissions re-examination in China. Separate surveys were conducted with applicants, postgraduate supervisors, and admissions staff members to gather their opinions and suggestions regarding the online MOSE re-examination. A total of 65 applicants, 43 postgraduate supervisors and seven admissions staff members completed the surveys. Over 80% of the applicants agreed that the online MOSE comprehensively evaluated their medical humanities, communication, medical knowledge, and overall competence. Furthermore, 89.30% of postgraduate supervisors believed that the students recruited through online MOSE were either "not significantly different," "better," or "much better" compared to those recruited through on-site re-examination. Admissions staff members also expressed a favorable view of online MOSE re-examination. The online MOSE re-examination is an effective, convenient, and affirmative evaluation method for postgraduate admissions re-examination.
- Open Access
- 1 January 2021
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 65 (3) , 298-302
Bonding to zirconia: Effects of translucency and cusp inclinations using an experimental methodology
Purpose: To investigate the effects of translucency and cusp inclination on the micro-shear bond strength (µSBS) of zirconia to self-adhesive resin cement (SARC). Methods: Sixty U-shaped zirconia specimens with 1.0 mm thickness consisting of three planes (0°, 20°, and 30°) simulating different cusp inclinations were fabricated from zirconia blocks of high, moderate, and low translucency (n=20). SARC was bonded to the specimen and light-cured for 40 s. The µSBS was tested using a universal testing machine with a cross-head at a speed of 0.5 mm/min and fracture mode was observed using a stereomicroscope (×50). Two-way analysis of variance followed by a post hoc Tukey’s honest significant difference test was used for the statistical analyses (α=0.05). Results: Varied µSBS values were found in the test groups (7.1–14.9 MPa). Within the zirconia of the same translucency, the µSBS value of the plane 0°specimen was significantly higher than that of the 20° and 30° planes (all pConclusions: Translucency and cusp inclination significantly affect the µSBS of zirconia to SARC. The higher the translucency, the greater are the µSBS values; the higher the cusp inclination, the lower are the µSBS values.
- 1 January 2021
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 65 (3) , 298-302
Open AccessBonding to zirconia: Effects of translucency and cusp inclinations using an experimental methodology
Purpose: To investigate the effects of translucency and cusp inclination on the micro-shear bond strength (µSBS) of zirconia to self-adhesive resin cement (SARC). Methods: Sixty U-shaped zirconia specimens with 1.0 mm thickness consisting of three planes (0°, 20°, and 30°) simulating different cusp inclinations were fabricated from zirconia blocks of high, moderate, and low translucency (n=20). SARC was bonded to the specimen and light-cured for 40 s. The µSBS was tested using a universal testing machine with a cross-head at a speed of 0.5 mm/min and fracture mode was observed using a stereomicroscope (×50). Two-way analysis of variance followed by a post hoc Tukey’s honest significant difference test was used for the statistical analyses (α=0.05). Results: Varied µSBS values were found in the test groups (7.1–14.9 MPa). Within the zirconia of the same translucency, the µSBS value of the plane 0°specimen was significantly higher than that of the 20° and 30° planes (all pConclusions: Translucency and cusp inclination significantly affect the µSBS of zirconia to SARC. The higher the translucency, the greater are the µSBS values; the higher the cusp inclination, the lower are the µSBS values.
- Open Access
- 5 August 2020
- Published by Springer Nature in BMC Oral Health
- Vol. 20 (1) , 1-7
Effects of remaining dentin thickness on the bond strength of bleached dentin
Background: The bond strength of resin composites to dentin was reported to be related to either the remaining dentin thickness (RDT) or bleaching treatment. However, information is limited regarding the effects of RDT on the bond strength of bleached dentin. The present study aimed to investigate the effects of RDT on the microshear bond strength (μSBS) of resin cement to bleached dentin. Methods: A total of 120 dentin specimens were prepared and randomly divided into 2 groups: a bleaching group (group B) and a control group (group C). Hydrogen peroxide with a concentration of 35% (Ultradent, USA) was applied on the dentin surface for 2 × 1 d for group B, while no bleaching treatment was performed for group C. After the treatment, the specimens were finished and polished to obtain different RDTs (2, 1, and 0.5 mm) and divided into 3 groups of 20 specimens each. The bonding procedure was performed using Panavia V5 (Kuraray, Japan) with a bonding area of 0.785 mm2. For each group, half of the specimens were subjected to 5000 thermal cycles (subgroup T), while the other half did not receive thermocycling (subgroup N) (n = 10). The specimens were then subjected to the μSBS test using a universal testing machine. Data were analyzed by a three-way analysis of variance (α = 0.05). The fracture modes of the specimens were confirmed with a measuring microscope. Representative specimens with different fracture modes were observed with scanning electron microscopy (SEM). Results: The μSBS values were significantly affected by bleaching treatment (p < 0.001), whereas no significant effect was observed for thermocycling (p = 0.293). In terms of RDT, a significantly different μSBS value was found among the subgroups with different RDTs in group C (p = 0.003). However, the RDT did not significantly affect the μSBS values of bleached dentin in group B (p = 0.779). The μSBS values were significantly lower in group B than in group C (p < 0.001). A higher percentage of adhesive failure was observed in group B than in group C. Conclusion: Based on the present findings, it can be concluded that the RDT did not affect the bond strength of resin cement to bleached dentin. Clinical significance: Since RDT did not affect the bond strength of resin cement to bleached dentin, bonding procedures should not be performed immediately after intracoronal bleaching, even if the dentin is planned to be removed due to a tooth preparation process.
- 5 August 2020
- Published by Springer Nature in BMC Oral Health
- Vol. 20 (1) , 1-7
Open AccessEffects of remaining dentin thickness on the bond strength of bleached dentin
Background: The bond strength of resin composites to dentin was reported to be related to either the remaining dentin thickness (RDT) or bleaching treatment. However, information is limited regarding the effects of RDT on the bond strength of bleached dentin. The present study aimed to investigate the effects of RDT on the microshear bond strength (μSBS) of resin cement to bleached dentin. Methods: A total of 120 dentin specimens were prepared and randomly divided into 2 groups: a bleaching group (group B) and a control group (group C). Hydrogen peroxide with a concentration of 35% (Ultradent, USA) was applied on the dentin surface for 2 × 1 d for group B, while no bleaching treatment was performed for group C. After the treatment, the specimens were finished and polished to obtain different RDTs (2, 1, and 0.5 mm) and divided into 3 groups of 20 specimens each. The bonding procedure was performed using Panavia V5 (Kuraray, Japan) with a bonding area of 0.785 mm2. For each group, half of the specimens were subjected to 5000 thermal cycles (subgroup T), while the other half did not receive thermocycling (subgroup N) (n = 10). The specimens were then subjected to the μSBS test using a universal testing machine. Data were analyzed by a three-way analysis of variance (α = 0.05). The fracture modes of the specimens were confirmed with a measuring microscope. Representative specimens with different fracture modes were observed with scanning electron microscopy (SEM). Results: The μSBS values were significantly affected by bleaching treatment (p < 0.001), whereas no significant effect was observed for thermocycling (p = 0.293). In terms of RDT, a significantly different μSBS value was found among the subgroups with different RDTs in group C (p = 0.003). However, the RDT did not significantly affect the μSBS values of bleached dentin in group B (p = 0.779). The μSBS values were significantly lower in group B than in group C (p < 0.001). A higher percentage of adhesive failure was observed in group B than in group C. Conclusion: Based on the present findings, it can be concluded that the RDT did not affect the bond strength of resin cement to bleached dentin. Clinical significance: Since RDT did not affect the bond strength of resin cement to bleached dentin, bonding procedures should not be performed immediately after intracoronal bleaching, even if the dentin is planned to be removed due to a tooth preparation process.
- Open Access
- 1 January 2020
- Published by Wiley in BioMed Research International
- Vol. 2020 (1) , 3529781
The Influence of Recycling on the Properties of Interface between Ceramic and Dental Alloys
Statement of Problem. Results are discrepant regarding the metal‐ceramic interface of dental alloys affected by recycling. Purpose. The purpose of this study was to evaluate the effect of recycling on the properties of interface between 2 dental alloys and their corresponding porcelains. Materials and Methods. Noble alloy (Pd‐Cu‐Ga) and high‐noble alloy (Au‐Pt) were used in this study. Metal matrices (cylinders Φ4 mm × 4 mm with pedestal Φ5 mm × 1 mm) were prepared by arc melting in argon after recasting 1‐3 times. Corresponding porcelain with overall dimensions of Φ4 mm × 2 mm was veneered on each metal cylinder. There were 22 specimens in each alloy group. Specifically, two specimens of each group were chosen randomly for interfacial morphology and diffusion analyses by scanning electron microscopy (SEM) equipped with energy‐dispersive X‐ray spectroscopy (EDS). The remaining 20 specimens were divided into 2 groups with or without thermal cycling. The bond strength was evaluated by shear test, and the data were analyzed by two‐way analysis of variance (ANOVA). The failure mode of shear test specimen was observed with a stereoscopic microscopy and subjected to the exact probability test (α = 0.05). Results. According to the results from SEM, no obvious difference was observed in the interfacial morphology of both Pd‐Cu‐Ga and Au‐Pt alloys among different recasting specimens. EDS analysis revealed that no significant difference was found in the width of elemental diffusion among 2 test alloys after recycling 1‐3 times. Notably, in Pd‐Cu‐Ga alloy groups, the peak of Ga in thrice recasting was lower than those in first and second recastings. And there was no significant difference (P > 0.05) in the metal‐ceramic shear bond strength of Pd‐Cu‐Ga and Au‐Pt alloys after recycling 1‐3 times, with or without thermal cycling. The results of failure modes observed on specimens were not affected by the recycling and thermal cycling in the 2 tested alloys. Conclusions. Within the limitations of this study, the Pd‐Cu‐Ga and Au‐Pt alloys can be recycled 2 times without significant changes on the properties of metal‐ceramic interface, with or without thermal cycling.
- 1 January 2020
- Published by Wiley in BioMed Research International
- Vol. 2020 (1) , 3529781
Open AccessThe Influence of Recycling on the Properties of Interface between Ceramic and Dental Alloys
Statement of Problem. Results are discrepant regarding the metal‐ceramic interface of dental alloys affected by recycling. Purpose. The purpose of this study was to evaluate the effect of recycling on the properties of interface between 2 dental alloys and their corresponding porcelains. Materials and Methods. Noble alloy (Pd‐Cu‐Ga) and high‐noble alloy (Au‐Pt) were used in this study. Metal matrices (cylinders Φ4 mm × 4 mm with pedestal Φ5 mm × 1 mm) were prepared by arc melting in argon after recasting 1‐3 times. Corresponding porcelain with overall dimensions of Φ4 mm × 2 mm was veneered on each metal cylinder. There were 22 specimens in each alloy group. Specifically, two specimens of each group were chosen randomly for interfacial morphology and diffusion analyses by scanning electron microscopy (SEM) equipped with energy‐dispersive X‐ray spectroscopy (EDS). The remaining 20 specimens were divided into 2 groups with or without thermal cycling. The bond strength was evaluated by shear test, and the data were analyzed by two‐way analysis of variance (ANOVA). The failure mode of shear test specimen was observed with a stereoscopic microscopy and subjected to the exact probability test (α = 0.05). Results. According to the results from SEM, no obvious difference was observed in the interfacial morphology of both Pd‐Cu‐Ga and Au‐Pt alloys among different recasting specimens. EDS analysis revealed that no significant difference was found in the width of elemental diffusion among 2 test alloys after recycling 1‐3 times. Notably, in Pd‐Cu‐Ga alloy groups, the peak of Ga in thrice recasting was lower than those in first and second recastings. And there was no significant difference (P > 0.05) in the metal‐ceramic shear bond strength of Pd‐Cu‐Ga and Au‐Pt alloys after recycling 1‐3 times, with or without thermal cycling. The results of failure modes observed on specimens were not affected by the recycling and thermal cycling in the 2 tested alloys. Conclusions. Within the limitations of this study, the Pd‐Cu‐Ga and Au‐Pt alloys can be recycled 2 times without significant changes on the properties of metal‐ceramic interface, with or without thermal cycling.
- Open Access
- 27 March 2019
- Published by Springer Nature in BMC Oral Health
- Vol. 19 (1) , 50
Effect of surface removal following bleaching on the bond strength of enamel
A reduction in bond strength of bleached enamel has been confirmed in the literature. Although limited information is available, it is conceivable that the veneer preparation process may remove the impacted enamel and further eliminate the compromised bond strength between the composite resin and bleached enamel. This study aimed to evaluate the effect of surface removal following bleaching on the micro-shear bond strength (μSBS) of bleached enamel. Forty-eight specimens were prepared from bovine incisors and were randomly divided into 2 groups (n = 24): group B (bleaching with 40% hydrogen peroxide for 2 × 45 min with a 1-week interval) and group C (control group without bleaching treatment). Immediately after receiving the treatments, 0.5 mm of the enamel was removed from the specimen surface, followed by bonding of composite resin to the enamel surface. Each group was further divided into 2 subgroups of 12 specimens each: subgroup T (with 5000 thermocycles in water baths at 5 °C and 55 °C), and subgroup N (without thermocycling). The μSBS values were measured using a universal testing machine and subjected to two-way analysis of variance (α = 0.05). The fracture modes of the specimens were observed using a stereomicroscope. The μSBS values of the different groups ranged from 21.42 to 25.21 MPa. Following a surface reduction of 0.5 mm, bleaching treatment and thermocycling did not significantly affect the μSBS values (P = 0.348 and P = 0.507, respectively). No significant interaction was found between the bleaching treatment and thermocycling (P = 0.514). All the groups exhibited a high percentage of mixed failures. Compared with group C, group B exhibited higher percentage of adhesive failure. The results suggested that the bonding procedure could be performed on the bleached enamel following a surface reduction of 0.5 mm immediately after the bleaching treatment.
- 27 March 2019
- Published by Springer Nature in BMC Oral Health
- Vol. 19 (1) , 50
Open AccessEffect of surface removal following bleaching on the bond strength of enamel
A reduction in bond strength of bleached enamel has been confirmed in the literature. Although limited information is available, it is conceivable that the veneer preparation process may remove the impacted enamel and further eliminate the compromised bond strength between the composite resin and bleached enamel. This study aimed to evaluate the effect of surface removal following bleaching on the micro-shear bond strength (μSBS) of bleached enamel. Forty-eight specimens were prepared from bovine incisors and were randomly divided into 2 groups (n = 24): group B (bleaching with 40% hydrogen peroxide for 2 × 45 min with a 1-week interval) and group C (control group without bleaching treatment). Immediately after receiving the treatments, 0.5 mm of the enamel was removed from the specimen surface, followed by bonding of composite resin to the enamel surface. Each group was further divided into 2 subgroups of 12 specimens each: subgroup T (with 5000 thermocycles in water baths at 5 °C and 55 °C), and subgroup N (without thermocycling). The μSBS values were measured using a universal testing machine and subjected to two-way analysis of variance (α = 0.05). The fracture modes of the specimens were observed using a stereomicroscope. The μSBS values of the different groups ranged from 21.42 to 25.21 MPa. Following a surface reduction of 0.5 mm, bleaching treatment and thermocycling did not significantly affect the μSBS values (P = 0.348 and P = 0.507, respectively). No significant interaction was found between the bleaching treatment and thermocycling (P = 0.514). All the groups exhibited a high percentage of mixed failures. Compared with group C, group B exhibited higher percentage of adhesive failure. The results suggested that the bonding procedure could be performed on the bleached enamel following a surface reduction of 0.5 mm immediately after the bleaching treatment.
- 1 January 2019
- Vol. 22 (3) , 189-196
Effects of Different Root Canal Obturation Techniques on the Bond Strength of Fiber Post to Intraradicular Dentine
Objective: To evaluate the bond strength of fiber posts to intraradicular dentine pretreated with two root canal obturation techniques and three postspace irrigation solutions. Methods: A total of 96 human premolars were collected and treated with complete or partial root canal obturation techniques. The roots were further divided into three subgroups (n = 16) based on postspace irrigation solutions: 2.5% NaOCl, 37% phosphoric acid etching, and distilled water. The fiber posts were bonded with self-adhesive resin cement, and the roots were sectioned into three slices (cervical, middle, and apical regions) after 5,000 thermocycles. The push-out bond strengths were determined and subjected to analysis of variance (alpha = 0.05). A stereomicroscope we used to observe the failure modes of the specimens. Results: The irrigation solution, root canal obturation technique, and root region had significant effects on bond strength (P < 0.001). The completely obturated root canals showed significantly lower bond strength than the partially obturated root canals. The 2.5% NaOCl treatment produced the highest bond strength among the three irrigation solutions. Among the root regions, the cervical part showed significantly greater bond strength than the middle and apical parts. The most common failure mode was mixed failure. Conclusion: The partial root canal obturation technique provided better bond strength of the fiber post to intraradicular dentine. Irrigation with 2.5% NaOCl solution and phosphoric acid etching before cementation improved the push-out bond strength of the fiber posts to intraradicular dentine.
- 1 January 2019
- Vol. 22 (3) , 189-196
Effects of Different Root Canal Obturation Techniques on the Bond Strength of Fiber Post to Intraradicular Dentine
Objective: To evaluate the bond strength of fiber posts to intraradicular dentine pretreated with two root canal obturation techniques and three postspace irrigation solutions. Methods: A total of 96 human premolars were collected and treated with complete or partial root canal obturation techniques. The roots were further divided into three subgroups (n = 16) based on postspace irrigation solutions: 2.5% NaOCl, 37% phosphoric acid etching, and distilled water. The fiber posts were bonded with self-adhesive resin cement, and the roots were sectioned into three slices (cervical, middle, and apical regions) after 5,000 thermocycles. The push-out bond strengths were determined and subjected to analysis of variance (alpha = 0.05). A stereomicroscope we used to observe the failure modes of the specimens. Results: The irrigation solution, root canal obturation technique, and root region had significant effects on bond strength (P < 0.001). The completely obturated root canals showed significantly lower bond strength than the partially obturated root canals. The 2.5% NaOCl treatment produced the highest bond strength among the three irrigation solutions. Among the root regions, the cervical part showed significantly greater bond strength than the middle and apical parts. The most common failure mode was mixed failure. Conclusion: The partial root canal obturation technique provided better bond strength of the fiber post to intraradicular dentine. Irrigation with 2.5% NaOCl solution and phosphoric acid etching before cementation improved the push-out bond strength of the fiber posts to intraradicular dentine.
- Open Access
- 1 September 2018
- Published by Elsevier in Journal of Dentistry
- Vol. 76, 40-45
In situ effect of Tooth Mousse containing CPP-ACP on human enamel subjected to in vivo acid attacks
- 1 September 2018
- Published by Elsevier in Journal of Dentistry
- Vol. 76, 40-45
Open AccessIn situ effect of Tooth Mousse containing CPP-ACP on human enamel subjected to in vivo acid attacks
- 1 September 2018
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 120 (3) , 462-469
Effects of cyclic staining on the color, translucency, surface roughness, and substance loss of contemporary adhesive resin cements
- 1 September 2018
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 120 (3) , 462-469
Effects of cyclic staining on the color, translucency, surface roughness, and substance loss of contemporary adhesive resin cements
- Open Access
- 11 July 2018
- Published by Wiley in Journal of Spectroscopy
- Vol. 2018, 1-7
Effect of Different Coloring Procedures on the Aging Behavior of Dental Monolithic Zirconia
Objective. This study aimed to investigate the effect of different coloring procedures on the aging behavior of dental monolithic zirconia. Methods. Two types of translucent zirconia (SuperfectZir HTS, Aidite; Katana HT, Kuraray) were tested. Bar-shaped specimens with dimensions of 22 × 4 × 2 mm were prepared from uncolored and precolored blocks. Before being sintered, specimens made from uncolored blocks were colored by dipping them into a coloring liquid, whereas the precolored specimens were not treated. The specimens were then divided into 4 subgroups (n = 13) according to the aging conditions (no aging, 134°C/0.2 MPa for 5 h, 134°C/0.2 MPa for 10 h, and 134°C/0.2 MPa for 20 h). The flexural strength of the specimens was tested with the 4-point flexure. The crystalline phase composition of the specimens was analyzed by XRD. The subsurface microstructure of the fractured specimens was examined by using a SEM. The data were statistically analyzed using 3-way ANOVA and Tukey’s test (α = 0.05). Results. Significant differences were found in the flexural strength between the two zirconia materials tested (). Aging and coloring procedures showed no significant effect on the flexural strength of the zirconia. Aging and coloring procedures significantly affected the t→m transformation of the zirconia. The monoclinic phase increased with the aging time. After aging, the precolored specimens showed a significantly higher t→m transformation than the specimens that were dipped in the coloring liquids. After aging for 20 h, the depth of the transformed zone with an irregular surface was approximately 6 µm for SuperfectZir HTS, whereas no detectable transformation zone was observed for Katana HT. Conclusion. Aging and coloring procedures had no significant effects on the flexural strength of the zirconia tested. The coloring procedure had a significant effect on the phase transformation of the zirconia subjected to hydrothermal aging.- 11 July 2018
- Published by Wiley in Journal of Spectroscopy
- Vol. 2018, 1-7
Open AccessEffect of Different Coloring Procedures on the Aging Behavior of Dental Monolithic Zirconia
Objective. This study aimed to investigate the effect of different coloring procedures on the aging behavior of dental monolithic zirconia. Methods. Two types of translucent zirconia (SuperfectZir HTS, Aidite; Katana HT, Kuraray) were tested. Bar-shaped specimens with dimensions of 22 × 4 × 2 mm were prepared from uncolored and precolored blocks. Before being sintered, specimens made from uncolored blocks were colored by dipping them into a coloring liquid, whereas the precolored specimens were not treated. The specimens were then divided into 4 subgroups (n = 13) according to the aging conditions (no aging, 134°C/0.2 MPa for 5 h, 134°C/0.2 MPa for 10 h, and 134°C/0.2 MPa for 20 h). The flexural strength of the specimens was tested with the 4-point flexure. The crystalline phase composition of the specimens was analyzed by XRD. The subsurface microstructure of the fractured specimens was examined by using a SEM. The data were statistically analyzed using 3-way ANOVA and Tukey’s test (α = 0.05). Results. Significant differences were found in the flexural strength between the two zirconia materials tested (). Aging and coloring procedures showed no significant effect on the flexural strength of the zirconia. Aging and coloring procedures significantly affected the t→m transformation of the zirconia. The monoclinic phase increased with the aging time. After aging, the precolored specimens showed a significantly higher t→m transformation than the specimens that were dipped in the coloring liquids. After aging for 20 h, the depth of the transformed zone with an irregular surface was approximately 6 µm for SuperfectZir HTS, whereas no detectable transformation zone was observed for Katana HT. Conclusion. Aging and coloring procedures had no significant effects on the flexural strength of the zirconia tested. The coloring procedure had a significant effect on the phase transformation of the zirconia subjected to hydrothermal aging. - Open Access
- 20 June 2018
- Published by Wiley in Journal of Spectroscopy
- Vol. 2018, 1-9
Polymerization Efficiency of a Dual-Cured Resin Cement through Zirconia with Three Different Cusp Inclinations
Assessing the polymerization efficiency of a dual-cured resin cement through zirconia with three different cusp inclinations is the aim of this study. Seventy-two resin cement (Multilink Speed) specimens were light-cured through the zirconia with three different cusp inclinations (30°, 20°, and 0°) for 20 s or 40 s (). For each group, the Vickers hardness (VH) measurement was performed on half of the specimens, whereas the degree of conversion (DC) was tested for the other half with a Fourier transform infrared spectrometer. The recorded data were analyzed with a two-way ANOVA. Varied VH (32.3 ± 3.2–40.3 ± 4.8) and DC (50.5% ± 3.0%–59.6% ± 2.4%) values were obtained from different groups. The cusp inclinations significantly affect the VH () and DC () of the resin cement, and the curing time exhibited a significant effect on the DC () of resin cement but not on the VH (). In conclusion, the cusp inclination of zirconia significantly affects the polymerization efficiency of dual-cured resin cement.- 20 June 2018
- Published by Wiley in Journal of Spectroscopy
- Vol. 2018, 1-9
Open AccessPolymerization Efficiency of a Dual-Cured Resin Cement through Zirconia with Three Different Cusp Inclinations
Assessing the polymerization efficiency of a dual-cured resin cement through zirconia with three different cusp inclinations is the aim of this study. Seventy-two resin cement (Multilink Speed) specimens were light-cured through the zirconia with three different cusp inclinations (30°, 20°, and 0°) for 20 s or 40 s (). For each group, the Vickers hardness (VH) measurement was performed on half of the specimens, whereas the degree of conversion (DC) was tested for the other half with a Fourier transform infrared spectrometer. The recorded data were analyzed with a two-way ANOVA. Varied VH (32.3 ± 3.2–40.3 ± 4.8) and DC (50.5% ± 3.0%–59.6% ± 2.4%) values were obtained from different groups. The cusp inclinations significantly affect the VH () and DC () of the resin cement, and the curing time exhibited a significant effect on the DC () of resin cement but not on the VH (). In conclusion, the cusp inclination of zirconia significantly affects the polymerization efficiency of dual-cured resin cement.