Volker Hinrichsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Volker Hinrichsen has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Cameron Tropea
Technical University of Darmstadt
3 shared publications - Jens-Michael Löwe
High-Voltage Laboratories, Technical University of Darmstadt, Darmstadt, 64283, Germany
3 shared publications - Alexander Rocks
TU Darmstadt, Highvoltage Labs, Landgraf-Georg-Str. 4, 64283 Darmstadt, Germany
2 shared publications - Christoph Drefke
TransnetBW GmbH, Stuttgart, Germany
2 shared publications - Ingo Sass
Geothermal Science and Technology, Institute of Applied Geosciences, Technical University of Darmstadt, Schnittspahnstrasse 9, 64287 Darmstadt, Germany
2 shared publications - Markus Schedel
Darmstadt Graduate School of Excellence Energy Science and Engineering, Darmstadt, Germany
2 shared publications
Latest Publications
- 31 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2843-2853
Commissioning and Service Experience With a ±550 kV DC GIL Conducted in Frame of a CIGRE Prototype Installation Test
A newly developed ±550 kV DC GIL (direct current gas-insulated transmission line) prototype was erected at a HVDC test facility at the Technical University of Darmstadt to collect first service experience with this new equipment. The 100 m long DC GIL prototype is periodically stressed with DC voltage and DC current as well as superimposed impulse voltage. The test equipment was procured for the project and partly newly developed. The overall procedure follows the prototype installation test recommendations from CIGRE TB 842. This paper presents experience collected during the commissioning and long-term testing of the DC GIL prototype. The commissioning process, events occurred, as well as resulting conclusions for type, factory acceptance and site acceptance tests of DC GIL systems are discussed. The long-term operation of the DC GIL is intended to run continuously. Interruptions occur due to external influences only. Partial discharge events and the overall performance of the DC GIL prototype during long-term stress are presented.
- 31 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2843-2853
Commissioning and Service Experience With a ±550 kV DC GIL Conducted in Frame of a CIGRE Prototype Installation Test
A newly developed ±550 kV DC GIL (direct current gas-insulated transmission line) prototype was erected at a HVDC test facility at the Technical University of Darmstadt to collect first service experience with this new equipment. The 100 m long DC GIL prototype is periodically stressed with DC voltage and DC current as well as superimposed impulse voltage. The test equipment was procured for the project and partly newly developed. The overall procedure follows the prototype installation test recommendations from CIGRE TB 842. This paper presents experience collected during the commissioning and long-term testing of the DC GIL prototype. The commissioning process, events occurred, as well as resulting conclusions for type, factory acceptance and site acceptance tests of DC GIL systems are discussed. The long-term operation of the DC GIL is intended to run continuously. Interruptions occur due to external influences only. Partial discharge events and the overall performance of the DC GIL prototype during long-term stress are presented.
- Open Access
- 27 December 2021
- Published by Wiley in Vadose Zone Journal
- Vol. 21 (1) , e20173
Experiment for validation of numerical models of coupled heat and mass transfer around energy cables
The increasing decentralization of electrical energy production as well as an increasing number of fluctuating regenerative energy sources require significant investments in grid expansion. Among other assessments, an exact prediction of the thermal behavior of the cable environment is necessary to be able to design cable routes both technically and economically sufficient. To investigate the coupled thermal and hydraulic processes around a cable‐like heat source with high temporal and spatial resolution under controlled boundary conditions, a cylindrical laboratory test was designed and experiments with two soils conducted. The data collected can be used to validate models of coupled heat and mass transfer around power cables. Within this study, the experimental data was compared with a modified model approach that is based on experimentally determined input data for the thermal and hydraulic properties of the examined soils. Although overall good agreement in the temperature field around the central heat source was observed, differences in the spatial distribution of the dry‐out zone near the heat source led to some shift between the measured and simulated temperatures.
- 27 December 2021
- Published by Wiley in Vadose Zone Journal
- Vol. 21 (1) , e20173
Open AccessExperiment for validation of numerical models of coupled heat and mass transfer around energy cables
The increasing decentralization of electrical energy production as well as an increasing number of fluctuating regenerative energy sources require significant investments in grid expansion. Among other assessments, an exact prediction of the thermal behavior of the cable environment is necessary to be able to design cable routes both technically and economically sufficient. To investigate the coupled thermal and hydraulic processes around a cable‐like heat source with high temporal and spatial resolution under controlled boundary conditions, a cylindrical laboratory test was designed and experiments with two soils conducted. The data collected can be used to validate models of coupled heat and mass transfer around power cables. Within this study, the experimental data was compared with a modified model approach that is based on experimentally determined input data for the thermal and hydraulic properties of the examined soils. Although overall good agreement in the temperature field around the central heat source was observed, differences in the spatial distribution of the dry‐out zone near the heat source led to some shift between the measured and simulated temperatures.
- Open Access
Heat Dissipation in Variable Underground Power Cable Beddings: Experiences from a Real Scale Field Experiment
To prevent accelerated thermal aging or insulation faults in cable systems due to overheating, the current carrying capacity is usually limited by specific conductor temperatures. As the heat produced during the operation of underground cables has to be dissipated to the environment, the actual current carrying capacity of a power cable system is primarily dependent on the thermal properties of the surrounding porous bedding material and soil. To investigate the heat dissipation processes around buried power cables of real scale and with realistic electric loading, a field experiment consisting of a main field with various cable configurations, laid in four different bedding materials, and a side field with additional cable trenches for thermally enhanced bedding materials and protection pipe systems was planned and constructed. The experimental results present the strong influences of the different bedding materials on the maximum cable ampacity. Alongside the importance of the basic thermal properties, the influence of the bedding’s hydraulic properties, especially on the drying and rewetting effects, were observed. Furthermore, an increase in ampacity between 25% and 35% was determined for a cable system in a duct filled with an artificial grouting material compared to a common air-filled ducted system.
Open AccessHeat Dissipation in Variable Underground Power Cable Beddings: Experiences from a Real Scale Field Experiment
To prevent accelerated thermal aging or insulation faults in cable systems due to overheating, the current carrying capacity is usually limited by specific conductor temperatures. As the heat produced during the operation of underground cables has to be dissipated to the environment, the actual current carrying capacity of a power cable system is primarily dependent on the thermal properties of the surrounding porous bedding material and soil. To investigate the heat dissipation processes around buried power cables of real scale and with realistic electric loading, a field experiment consisting of a main field with various cable configurations, laid in four different bedding materials, and a side field with additional cable trenches for thermally enhanced bedding materials and protection pipe systems was planned and constructed. The experimental results present the strong influences of the different bedding materials on the maximum cable ampacity. Alongside the importance of the basic thermal properties, the influence of the bedding’s hydraulic properties, especially on the drying and rewetting effects, were observed. Furthermore, an increase in ampacity between 25% and 35% was determined for a cable system in a duct filled with an artificial grouting material compared to a common air-filled ducted system.
- 16 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (2) , 871-879
Simulation Analysis of Critical Parameters for Thermal Stability of Surge Arresters
Ensuring thermal stability is an important aspect of an arrester design process. In this paper, the thermal stability of station class surge arresters is investigated using a coupled electrothermal numerical model. An ungraded 550-kV-station class arrester model is successfully validated against temperature measurements in power grid operation. The arrester cooling rate is introduced to determine the thermal stability threshold. Thermally stable and unstable scenarios are compared. The influence of selected arrester design parameters on the stability threshold is analyzed. It is shown that an improved heat transfer in the arrester air gap increases the thermal stability threshold significantly. Additionally, the nonlinear zinc oxide material characteristics influence the thermal stability threshold strongly. Furthermore, a thermal stability prediction approach based on few, computationally less expensive simulations is proposed. Finally, the results are confirmed for an arrester model that is equipped with a field-grading system. The paper shows that the presented field simulation approach can be reliably used to determine the stability threshold of an arrester, thus, reducing the need for costly laboratory tests.
- 16 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (2) , 871-879
Simulation Analysis of Critical Parameters for Thermal Stability of Surge Arresters
Ensuring thermal stability is an important aspect of an arrester design process. In this paper, the thermal stability of station class surge arresters is investigated using a coupled electrothermal numerical model. An ungraded 550-kV-station class arrester model is successfully validated against temperature measurements in power grid operation. The arrester cooling rate is introduced to determine the thermal stability threshold. Thermally stable and unstable scenarios are compared. The influence of selected arrester design parameters on the stability threshold is analyzed. It is shown that an improved heat transfer in the arrester air gap increases the thermal stability threshold significantly. Additionally, the nonlinear zinc oxide material characteristics influence the thermal stability threshold strongly. Furthermore, a thermal stability prediction approach based on few, computationally less expensive simulations is proposed. Finally, the results are confirmed for an arrester model that is equipped with a field-grading system. The paper shows that the presented field simulation approach can be reliably used to determine the stability threshold of an arrester, thus, reducing the need for costly laboratory tests.
- 14 January 2021
- Published by American Physical Society (APS) in Physical Review E
- Vol. 103 (1) , 012801
Ice nucleation in high alternating electric fields: Effect of electric field strength and frequency
Icing is a severe problem for many technical systems such as aircraft or systems for high-voltage power transmission and distribution. Ice nucleation in water droplets is affected by several influencing factors like impurities or the liquid temperature, which have been widely investigated. However, although an electric field affects nucleation, this influence has been far less investigated and is still not completely understood. The present work is focused on the influence of high alternating electric fields on ice nucleation in sessile water droplets, which is examined for a systematic variation of the electric field frequency and strength. All experiments used to determine the influence of a single parameter like the electric field strength or frequency are performed with the same set of droplets to ensure well-defined conditions and a high repeatability of the procedure. For each parameter variation a large number of nucleation events is observed and analyzed. Droplet survival curves and the nucleation site density are used to analyze the experiments and to determine the influence of the electric field on ice nucleation. Especially for high electric field strengths, a significant influence on nucleation is observed. Some droplets freeze earlier, which leads to a higher median nucleation temperature. On the other hand, the lowest temperature required to freeze all droplets is almost constant compared to the reference case without an electric field. It is shown that not all droplets are affected by the electric field in the same way, but the influence of the electric field on ice nucleation is rather of singular nature. In addition, the frequency of the applied electric field has an impact on the nucleation behavior. The present experimental data quantitatively demonstrate the effect of an electric field on ice nucleation and improves our understanding of heterogeneous nucleation of supercooled water subjected to high alternating electric fields.
- 14 January 2021
- Published by American Physical Society (APS) in Physical Review E
- Vol. 103 (1) , 012801
Ice nucleation in high alternating electric fields: Effect of electric field strength and frequency
Icing is a severe problem for many technical systems such as aircraft or systems for high-voltage power transmission and distribution. Ice nucleation in water droplets is affected by several influencing factors like impurities or the liquid temperature, which have been widely investigated. However, although an electric field affects nucleation, this influence has been far less investigated and is still not completely understood. The present work is focused on the influence of high alternating electric fields on ice nucleation in sessile water droplets, which is examined for a systematic variation of the electric field frequency and strength. All experiments used to determine the influence of a single parameter like the electric field strength or frequency are performed with the same set of droplets to ensure well-defined conditions and a high repeatability of the procedure. For each parameter variation a large number of nucleation events is observed and analyzed. Droplet survival curves and the nucleation site density are used to analyze the experiments and to determine the influence of the electric field on ice nucleation. Especially for high electric field strengths, a significant influence on nucleation is observed. Some droplets freeze earlier, which leads to a higher median nucleation temperature. On the other hand, the lowest temperature required to freeze all droplets is almost constant compared to the reference case without an electric field. It is shown that not all droplets are affected by the electric field in the same way, but the influence of the electric field on ice nucleation is rather of singular nature. In addition, the frequency of the applied electric field has an impact on the nucleation behavior. The present experimental data quantitatively demonstrate the effect of an electric field on ice nucleation and improves our understanding of heterogeneous nucleation of supercooled water subjected to high alternating electric fields.
- 8 December 2020
- Published by American Physical Society (APS) in Physical Review E
- Vol. 102 (6) , 063101
Impact of electric charge and motion of water drops on the inception field strength of partial discharges
Strong electric fields may deform drops and induce their oscillation or motion on the substrate. Moreover, they can initiate partial discharges (PDs) because of the enhancement of the electric field in the vicinity of the three-phase contact lines. The partial discharges affect the drop spreading which can result in unusual drop shapes. In addition, the partial discharges can also deteriorate the surface properties of the substrate, e.g., of high-voltage composite insulators. In this study the occurrence of partial discharges due to stationary or oscillating sessile drops under the influence of an alternating electric field is investigated using a generic insulator model under well-defined conditions. Drops of a yield stress fluid (a gelatin-water mixture) are used to determine the PD inception field strength for stationary drop shapes. The influence of the volume as well as the distance between the individual drops for two drop configurations on the PD inception threshold is determined. The inception field strength of the partial discharges is measured for various drop volumes, drop charges, as well as for different resonance modes of drop oscillations. Besides the electrical measurement, the location of the partial discharges is optically determined by a UV camera. The detailed knowledge of the influencing factors of the partial discharges improves the understanding of the drop behavior under the impact of strong electric fields.
- 8 December 2020
- Published by American Physical Society (APS) in Physical Review E
- Vol. 102 (6) , 063101
Impact of electric charge and motion of water drops on the inception field strength of partial discharges
Strong electric fields may deform drops and induce their oscillation or motion on the substrate. Moreover, they can initiate partial discharges (PDs) because of the enhancement of the electric field in the vicinity of the three-phase contact lines. The partial discharges affect the drop spreading which can result in unusual drop shapes. In addition, the partial discharges can also deteriorate the surface properties of the substrate, e.g., of high-voltage composite insulators. In this study the occurrence of partial discharges due to stationary or oscillating sessile drops under the influence of an alternating electric field is investigated using a generic insulator model under well-defined conditions. Drops of a yield stress fluid (a gelatin-water mixture) are used to determine the PD inception field strength for stationary drop shapes. The influence of the volume as well as the distance between the individual drops for two drop configurations on the PD inception threshold is determined. The inception field strength of the partial discharges is measured for various drop volumes, drop charges, as well as for different resonance modes of drop oscillations. Besides the electrical measurement, the location of the partial discharges is optically determined by a UV camera. The detailed knowledge of the influencing factors of the partial discharges improves the understanding of the drop behavior under the impact of strong electric fields.
- 4 February 2020
- Published by American Physical Society (APS) in Physical Review E
- Vol. 101 (2) , 023102
Behavior of charged and uncharged drops in high alternating tangential electric fields
The interaction of drops and electric fields occurs in many applications like electrowetting, electrospinning, atomization, but also causes unwanted effects like the aging of high-voltage composite insulators. Water drops are influenced by electric fields due to the polar properties of the water molecules. The behavior of the drops depends on several parameters like the orientation and strength of the electric field, drop volume, and frequency of the applied field. In addition, electric charges can influence the behavior of drops significantly. However, the impact of electric charges, including the interaction with the drop as well as the electric field strength, is far from being well understood. In this work, the impact of electric charges on the behavior of single sessile drops is investigated experimentally under well-defined conditions. The effects of the drop volume, electric field strength, field frequency, and electric charge of the drop are studied. The necessary amount of charge to change the behavior of drops, depending on the applied electric field and drop volume, is determined and different drop behavior regimes are identified. Depending on the boundary conditions, the drop oscillates with the same or double the frequency of the applied voltage. The different regimes are investigated for the first three oscillation modes. The obtained results will help to improve the understanding and to manipulate the behavior of uncharged and charged drops in strong electric fields.
- 4 February 2020
- Published by American Physical Society (APS) in Physical Review E
- Vol. 101 (2) , 023102
Behavior of charged and uncharged drops in high alternating tangential electric fields
The interaction of drops and electric fields occurs in many applications like electrowetting, electrospinning, atomization, but also causes unwanted effects like the aging of high-voltage composite insulators. Water drops are influenced by electric fields due to the polar properties of the water molecules. The behavior of the drops depends on several parameters like the orientation and strength of the electric field, drop volume, and frequency of the applied field. In addition, electric charges can influence the behavior of drops significantly. However, the impact of electric charges, including the interaction with the drop as well as the electric field strength, is far from being well understood. In this work, the impact of electric charges on the behavior of single sessile drops is investigated experimentally under well-defined conditions. The effects of the drop volume, electric field strength, field frequency, and electric charge of the drop are studied. The necessary amount of charge to change the behavior of drops, depending on the applied electric field and drop volume, is determined and different drop behavior regimes are identified. Depending on the boundary conditions, the drop oscillates with the same or double the frequency of the applied voltage. The different regimes are investigated for the first three oscillation modes. The obtained results will help to improve the understanding and to manipulate the behavior of uncharged and charged drops in strong electric fields.
- 31 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (8) , 3525-3532
Comparison of Arc Motion in Different Lifetime Sealed Vacuum Interrupters With RMF Contacts
Vacuum circuit breakers are well established in the distribution levels of the electrical power grids. To maximize the short-circuit interruption performance, an radial magnetic field (RMF)-contact design forces the arc from a fault current to rotate. The performance of the RMF-contact designs is usually evaluated in a model vacuum chamber with viewing ports that allows observing arc rotation with the help of high-speed cameras. These setups differ significantly from lifetime sealed vacuum bottles in geometry (and thus volume) and due to the fact that the main metallic vapor shield cannot be present. This, in turn, can affect the arc rotation behavior. In order to overcome these shortcomings, a new diagnostic tool has been developed to analyze the arcing behavior in standard lifetime sealed vacuum interrupters. Optical methods are not possible here, since the view is blocked by the opaque ceramics and the metallic vapor shield. For this reason, a Hall-sensor-based measuring system is applied, in which the variation in the magnetic field from the arc position is observed by multiple sensors. This paper presents the comparison of arc motion in lifetime sealed vacuum interrupters with different bottle geometries. For this purpose, investigations with identical spiral-shaped RMF contacts inside different vacuum bottle designs with differing vacuum volumes are performed. Also, for comparison, an interrupter with contrate cup contacts was investigated. Similarities and differences between the corresponding arc motion behaviors are discussed.
- 31 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (8) , 3525-3532
Comparison of Arc Motion in Different Lifetime Sealed Vacuum Interrupters With RMF Contacts
Vacuum circuit breakers are well established in the distribution levels of the electrical power grids. To maximize the short-circuit interruption performance, an radial magnetic field (RMF)-contact design forces the arc from a fault current to rotate. The performance of the RMF-contact designs is usually evaluated in a model vacuum chamber with viewing ports that allows observing arc rotation with the help of high-speed cameras. These setups differ significantly from lifetime sealed vacuum bottles in geometry (and thus volume) and due to the fact that the main metallic vapor shield cannot be present. This, in turn, can affect the arc rotation behavior. In order to overcome these shortcomings, a new diagnostic tool has been developed to analyze the arcing behavior in standard lifetime sealed vacuum interrupters. Optical methods are not possible here, since the view is blocked by the opaque ceramics and the metallic vapor shield. For this reason, a Hall-sensor-based measuring system is applied, in which the variation in the magnetic field from the arc position is observed by multiple sensors. This paper presents the comparison of arc motion in lifetime sealed vacuum interrupters with different bottle geometries. For this purpose, investigations with identical spiral-shaped RMF contacts inside different vacuum bottle designs with differing vacuum volumes are performed. Also, for comparison, an interrupter with contrate cup contacts was investigated. Similarities and differences between the corresponding arc motion behaviors are discussed.
- 22 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (1) , 346-352
Testing Metal–Oxide Varistors for HVDC Breaker Application
There is growing interest in changing the power grid infrastructure. It is increasingly important to transport a large amount of renewable energy over long distances. To minimize losses, meshed DC-grids are needed but require the development of DC circuit breakers. Without it a meshed grid cannot be operated. Actually different concepts of DC breakers exist. The majority of them include an energy absorbing element. In AC grids metal-oxide varistors (MOVs) absorb high energies. However, clarification is needed whether commercial available MOVs are able to handle the energy stresses that arise during DC switching operations. To investigate the energy handling capabilities of conventional MO material an endurance test setup has been developed. In this setup MOV specimens are stressed by repetitive impulse current injections while being permanently connected to DC voltage. This study reports on the endurance behavior of MOV submitted to >10 000 impulse energy injections with 60 to 100 J/cm2. Large differences are observed for MOVs from different manufacturers. Temperature and superimposing the impulses by a constant DC voltage are two parameters of less impact. Two types of MOV showed moderate changes of their electrical properties after >10 000 impulses and would be suitable for DC breaker application.
- 22 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (1) , 346-352
Testing Metal–Oxide Varistors for HVDC Breaker Application
There is growing interest in changing the power grid infrastructure. It is increasingly important to transport a large amount of renewable energy over long distances. To minimize losses, meshed DC-grids are needed but require the development of DC circuit breakers. Without it a meshed grid cannot be operated. Actually different concepts of DC breakers exist. The majority of them include an energy absorbing element. In AC grids metal-oxide varistors (MOVs) absorb high energies. However, clarification is needed whether commercial available MOVs are able to handle the energy stresses that arise during DC switching operations. To investigate the energy handling capabilities of conventional MO material an endurance test setup has been developed. In this setup MOV specimens are stressed by repetitive impulse current injections while being permanently connected to DC voltage. This study reports on the endurance behavior of MOV submitted to >10 000 impulse energy injections with 60 to 100 J/cm2. Large differences are observed for MOVs from different manufacturers. Temperature and superimposing the impulses by a constant DC voltage are two parameters of less impact. Two types of MOV showed moderate changes of their electrical properties after >10 000 impulses and would be suitable for DC breaker application.
- 27 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 3155-3161
Increasing the Internal Field Strength of Vacuum Interrupters With Vapor Shield Potential Control
Internal dielectric strength of vacuum interrupters (VIs) is primarily determined by the macroscopic electric field strength on the electrode surfaces. Generally, the vacuum breakdown is initiated by field emissions from critical enhancement points with higher electric field on a cathode. A vapor shield of a VI is one component that determines the electric field strength and distribution. Its floating electrical potential can basically be determined by the geometry of the VI and its surroundings. Since the shield potential can change the maximum electric field strength at the front contact edge in VI, the present study focuses on the possibility of electrical potential control of the vapor shield for increasing the internal withstand voltage of VI. Basically, the potential control of the vapor shield can be realized by connecting a parallel capacitor network. Dielectric withstand tests for the 72.5 kV VI with potential control show that the breakdown voltage can be increased by 11.2%, by setting the vapor shield potential to one third of the applied voltage. The increase in breakdown voltage of the VI can be explained by the relaxation of electric field on the critical point because of the decrease in potential difference between cathode and vapor shield.
- 27 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 3155-3161
Increasing the Internal Field Strength of Vacuum Interrupters With Vapor Shield Potential Control
Internal dielectric strength of vacuum interrupters (VIs) is primarily determined by the macroscopic electric field strength on the electrode surfaces. Generally, the vacuum breakdown is initiated by field emissions from critical enhancement points with higher electric field on a cathode. A vapor shield of a VI is one component that determines the electric field strength and distribution. Its floating electrical potential can basically be determined by the geometry of the VI and its surroundings. Since the shield potential can change the maximum electric field strength at the front contact edge in VI, the present study focuses on the possibility of electrical potential control of the vapor shield for increasing the internal withstand voltage of VI. Basically, the potential control of the vapor shield can be realized by connecting a parallel capacitor network. Dielectric withstand tests for the 72.5 kV VI with potential control show that the breakdown voltage can be increased by 11.2%, by setting the vapor shield potential to one third of the applied voltage. The increase in breakdown voltage of the VI can be explained by the relaxation of electric field on the critical point because of the decrease in potential difference between cathode and vapor shield.