LSLivia Rentas Sanches

Livia Rentas Sanches

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Livia Rentas Sanches has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diagnostic accuracy of thromboelastometry and its correlation with the HPLC-MS/MS quantification test

    by V.F. de Aranda, P.B.M. Derogis, L.R. Sanches, C.L.P. Mangueira, M. Katz, A.C.L. Faulhaber, C.E.A. Mendes, C.E. dos Santos Ferreira, C.N. França, J.C. de Campos Guerra

    The aim of the study was to evaluate the diagnostic accuracy of thromboelastometry for assessing rivaroxaban concentrations. The accuracy of thromboelastometry was compared with the high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method, which is the gold standard for drug plasma monitoring (the reference standard). Forty-six clinically stable patients were treated with 10, 15, or 20 mg of rivaroxaban once daily (OD group) or 15 mg twice a day (BID group) (no particular indication for treatment). Patient samples were collected 2 h after the use of the medication (peak) and 2 h before the next dose (trough). The rivaroxaban plasma concentrations were determined via HPLC-MS/MS, and thromboelastometry was performed using a ROTEM® delta analyzer. There were significant prolongations in clotting time (CT) for the 10, 15, and 20 mg of rivaroxaban treatments in the OD groups. In the 15 mg BID group, the responses at the peak and trough times were similar. At the peak times, there was a positive correlation between the plasma concentration of rivaroxaban and CT (Spearman correlation rho=0.788, P<0.001) and clot formation time (rho=0.784, P<0.001), and a negative correlation for alpha angle (rho=−0.771, P<0.001), amplitude after 5 min (rho=−0.763, P<0.001), and amplitude after 10 min (rho=−0.680, P<0.001). The CT presented higher specificity and sensitivity using the cut-off determined by the receiver characteristics curve. ROTEM has potential as screening tool to measure possible bleeding risk associated with rivaroxaban plasma levels.


  • Calibration for the determination of 19 trace elements in serum and urine

    by Bruna M. Freire, Tatiana Pedron, Camila N. Lange, Livia R. Sanches, Gustavo R. M. Barcelos, Walter R. P. Filho, Bruno L. Batista

    A fast, high-throughput and accurate method was developed for determination of Al, As, Ba, Cd, Co, Cr, Cs, Cu, Fe, Mn, Ni, Pb, Se, U, Zn, Sb, Sn, I and Hg in urine and serum by inductively coupled plasma mass spectrometry. The samples were directly analyzed after 1/20 (v/v) dilution in 0.4% (v/v) HNO3 and 0.005% Triton X-100. Three calibration modes were tested: aqueous and matrix matching with urine and serum. The accuracy was tested using reference materials of serum, urine and spiking. Results showed that the use of matrix matching calibration reduced the interferences and improved the recoveries for Al, Co, Pb and I in urine. The matrix matching did not affect the results considerably for serum. When serum was spiked with As, Co, Cs, Pb, U, Hg, I, Ba, Al, Cr and Ni, only matrix matching presented good recoveries. Helium was used as a collision cell gas reducing effectively polyatomic interferences for Al, Mn, Cu, Ni, Cr, Zn, As and Fe. Selection of the best internal standard was carried out for each element. The use of diluted HNO3 improved the limit of detection. Finally, the method was applied successfully in samples of urine from workers occupationally exposed.


  • Mitochondrial ND5 mutation: neurological improvement after CoQ10 supplementation (P5.122)

    by Jose Luiz Pedroso, Maria Thereza Drumond Gama, Juliana Harumi Arita, Felipe Gustavo Ravagnani, Mário H Barros, Livia Rentas Sanches, Fabíola Rosa Picosse, Tania Oliveira Lopes, Patrícia de Carvalho Aguiar, Marcos Chiaratti, et al.