Livia Rentas Sanches
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Livia Rentas Sanches has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- A.C.L. Faulhaber
Hospital Israelita Albert Einstein, São Paulo, SP, Brasil
1 shared publication - Bruna Moreira Freire
Center for Natural and Human Sciences, Federal University of ABC, Santo André 09210-580, São Paulo, Brazil
1 shared publication - Bruno Lemos Batista
Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, Santo André 09280-560, SP, Brazil
1 shared publication - C.E.A. Mendes
Hospital Israelita Albert Einstein, São Paulo, SP, Brasil
1 shared publication - Camila Neves Lange
Centro de Ciências Naturais e Humanas, Universidade Federal do ABC, Santo André, São Paulo, Brazil
1 shared publication - Carlos Eduardo dos Santos Ferreira
Hospital Israelita Albert Einstein
1 shared publication
Latest Publications
- Open Access
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 52 (4) , e8006
Diagnostic accuracy of thromboelastometry and its correlation with the HPLC-MS/MS quantification test
The aim of the study was to evaluate the diagnostic accuracy of thromboelastometry for assessing rivaroxaban concentrations. The accuracy of thromboelastometry was compared with the high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method, which is the gold standard for drug plasma monitoring (the reference standard). Forty-six clinically stable patients were treated with 10, 15, or 20 mg of rivaroxaban once daily (OD group) or 15 mg twice a day (BID group) (no particular indication for treatment). Patient samples were collected 2 h after the use of the medication (peak) and 2 h before the next dose (trough). The rivaroxaban plasma concentrations were determined via HPLC-MS/MS, and thromboelastometry was performed using a ROTEM® delta analyzer. There were significant prolongations in clotting time (CT) for the 10, 15, and 20 mg of rivaroxaban treatments in the OD groups. In the 15 mg BID group, the responses at the peak and trough times were similar. At the peak times, there was a positive correlation between the plasma concentration of rivaroxaban and CT (Spearman correlation rho=0.788, P<0.001) and clot formation time (rho=0.784, P<0.001), and a negative correlation for alpha angle (rho=−0.771, P<0.001), amplitude after 5 min (rho=−0.763, P<0.001), and amplitude after 10 min (rho=−0.680, P<0.001). The CT presented higher specificity and sensitivity using the cut-off determined by the receiver characteristics curve. ROTEM has potential as screening tool to measure possible bleeding risk associated with rivaroxaban plasma levels.
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 52 (4) , e8006
Open AccessDiagnostic accuracy of thromboelastometry and its correlation with the HPLC-MS/MS quantification test
The aim of the study was to evaluate the diagnostic accuracy of thromboelastometry for assessing rivaroxaban concentrations. The accuracy of thromboelastometry was compared with the high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method, which is the gold standard for drug plasma monitoring (the reference standard). Forty-six clinically stable patients were treated with 10, 15, or 20 mg of rivaroxaban once daily (OD group) or 15 mg twice a day (BID group) (no particular indication for treatment). Patient samples were collected 2 h after the use of the medication (peak) and 2 h before the next dose (trough). The rivaroxaban plasma concentrations were determined via HPLC-MS/MS, and thromboelastometry was performed using a ROTEM® delta analyzer. There were significant prolongations in clotting time (CT) for the 10, 15, and 20 mg of rivaroxaban treatments in the OD groups. In the 15 mg BID group, the responses at the peak and trough times were similar. At the peak times, there was a positive correlation between the plasma concentration of rivaroxaban and CT (Spearman correlation rho=0.788, P<0.001) and clot formation time (rho=0.784, P<0.001), and a negative correlation for alpha angle (rho=−0.771, P<0.001), amplitude after 5 min (rho=−0.763, P<0.001), and amplitude after 10 min (rho=−0.680, P<0.001). The CT presented higher specificity and sensitivity using the cut-off determined by the receiver characteristics curve. ROTEM has potential as screening tool to measure possible bleeding risk associated with rivaroxaban plasma levels.
- 21 April 2018
- Published by Taylor & Francis in Toxicological & Environmental Chemistry
- Vol. 100 (4) , 395-412
Calibration for the determination of 19 trace elements in serum and urine
A fast, high-throughput and accurate method was developed for determination of Al, As, Ba, Cd, Co, Cr, Cs, Cu, Fe, Mn, Ni, Pb, Se, U, Zn, Sb, Sn, I and Hg in urine and serum by inductively coupled plasma mass spectrometry. The samples were directly analyzed after 1/20 (v/v) dilution in 0.4% (v/v) HNO3 and 0.005% Triton X-100. Three calibration modes were tested: aqueous and matrix matching with urine and serum. The accuracy was tested using reference materials of serum, urine and spiking. Results showed that the use of matrix matching calibration reduced the interferences and improved the recoveries for Al, Co, Pb and I in urine. The matrix matching did not affect the results considerably for serum. When serum was spiked with As, Co, Cs, Pb, U, Hg, I, Ba, Al, Cr and Ni, only matrix matching presented good recoveries. Helium was used as a collision cell gas reducing effectively polyatomic interferences for Al, Mn, Cu, Ni, Cr, Zn, As and Fe. Selection of the best internal standard was carried out for each element. The use of diluted HNO3 improved the limit of detection. Finally, the method was applied successfully in samples of urine from workers occupationally exposed.
- 21 April 2018
- Published by Taylor & Francis in Toxicological & Environmental Chemistry
- Vol. 100 (4) , 395-412
Calibration for the determination of 19 trace elements in serum and urine
A fast, high-throughput and accurate method was developed for determination of Al, As, Ba, Cd, Co, Cr, Cs, Cu, Fe, Mn, Ni, Pb, Se, U, Zn, Sb, Sn, I and Hg in urine and serum by inductively coupled plasma mass spectrometry. The samples were directly analyzed after 1/20 (v/v) dilution in 0.4% (v/v) HNO3 and 0.005% Triton X-100. Three calibration modes were tested: aqueous and matrix matching with urine and serum. The accuracy was tested using reference materials of serum, urine and spiking. Results showed that the use of matrix matching calibration reduced the interferences and improved the recoveries for Al, Co, Pb and I in urine. The matrix matching did not affect the results considerably for serum. When serum was spiked with As, Co, Cs, Pb, U, Hg, I, Ba, Al, Cr and Ni, only matrix matching presented good recoveries. Helium was used as a collision cell gas reducing effectively polyatomic interferences for Al, Mn, Cu, Ni, Cr, Zn, As and Fe. Selection of the best internal standard was carried out for each element. The use of diluted HNO3 improved the limit of detection. Finally, the method was applied successfully in samples of urine from workers occupationally exposed.
- 18 April 2017
- Published by Wolters Kluwer Health in Neurology
- Vol. 88 (16_supplem)
Mitochondrial ND5 mutation: neurological improvement after CoQ10 supplementation (P5.122)
- 18 April 2017
- Published by Wolters Kluwer Health in Neurology
- Vol. 88 (16_supplem)
Mitochondrial ND5 mutation: neurological improvement after CoQ10 supplementation (P5.122)