RORobin Otchwemah

Robin Otchwemah

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Robin Otchwemah has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Frauke Mattner

    Institute for Hygiene, Witten/Herdecke University, Division of Hygiene and Environmental Medicine, Cologne, Germany Cologne Merheim Medical Centre, University Hospital Witten/Herdecke, Cologne, Germany

    2 shared publications
  • Holger Bäthis

    Department of Trauma Surgery and Orthopedic Surgery, Cologne-Merheim Medical Center, University of Witten/Herdecke, Köln, Germany

    2 shared publications
  • Sven Shafizadeh

    Department of Trauma Surgery and Orthopedic Surgery, Cologne-Merheim Medical Center, University of Witten/Herdecke, Köln, Germany

    2 shared publications
  • Thorsten Tjardes

    Department of Trauma Surgery and Orthopedic Surgery, Cologne-Merheim Medical Center, University of Witten/Herdecke, Köln, Germany

    2 shared publications
  • Adnan Hamid

    Institute for Hygiene, Witten/Herdecke University, Division of Hygiene and Environmental Medicine, Cologne, Germany Cologne Merheim Medical Centre, University Hospital Witten/Herdecke, Cologne, Germany

    1 shared publication
  • Bertil Bouillon

    Department of Traumatology and Orthopedic Surgery, Cologne-Merheim Medical Center, Germany

    1 shared publication

Latest Publications

  • WHAT DO WE REALLY KNOW ABOUT HAND DISINFECTION PERFORMANCE DURING PATIENT CARE ON SURGICAL WARDS?

    by Robin Otchwemah, Dominik Sons, Swetlana Herbrand, Marieke Stolte, Adnan Hamid, Frauke Mattner

    Aim: Hand-disinfection (HD) is the most effective infection-prevention-measure. HD-performance of health care professionals (HCP) is usually evaluated by compliance observations (CO). The Hawthorne effect (HE) (HCP behave differently under observation) is considered to systematically increase HD-compliance-rates during CO. However, little is known about the specifications of the HE in health care settings. We hypothesized that, due to hand-hygiene`s known impact on patient safety and infection-prevention, the HE does not affect HD performance during direct patient care in patient-rooms.Method: We conducted a prospective observational trial on an 18-bed surgical intensive care unit (ICU), a 12-bed surgical intermediate care unit (IMC) and a 36-bed surgical normal ward (NW) in a university hospital in Germany. Dispensers of hand sanitizers were equipped with an electronic monitoring system (EMS) (GWA Hygiene, Germany), which recorded the number of HDs per patient hour (HD/PH) and time and location of hand-disinfections. Locations were categorized as follows: 1. Patient rooms (PR); 2. Utility- and waste-disposal-rooms (UWR) and 3. Other rooms (hallways, kitchen, toilets etc.) (OR). Additionally trained infection-control-staff performed hand-hygiene CO according to WHO's Five Moments. The HD/PH during CO was compared to the HD/PH during the same time-periods without CO. Additionally the ratio between HD/PD-change during CO and mean-HD/PD of each ward during the study-period was determined in percentages. Descriptive and analytical statistics were calculated using R. P-values ≤ 0.05 were regarded as significant.Results: 587.128 HD were electronically recorded during the study-period (February 2022 to May 2023) and CO took place on 72 days. We recorded a significant increase of HD/PH during CO on all three wards in PRs (ICU: 21%, p<0.001; IMC: 11%, p=0.029; NW: 49%, p=0.047). Furthermore we detected a significant increase of HD/PH during CO on ICU (10%, p<0.001) and IMC (11%, p=0.033) in ORs. CO did not significantly affect HD/PH in ORs on NW and in UWR on all three wards.Conclusions: In our setting, the number of hand-disinfections per patient-hour was significantly increased during compliance-observations especially in patient-rooms, where hand-hygiene is most crucial for infection-prevention. This indicates a lower everyday compliance to WHO`s hand-hygiene indications during patient care than determined by compliance-observations.Acknowledgments: Paul-Hartmann AG financially supported this study.

  • Effective Graft Preservation by Following a Standard Protocol for the Treatment of Knee Joint Infection after Anterior Cruciate Ligament Reconstruction

    by Robin Otchwemah, Jan-Hendrik Naendrup, Frauke Mattner, Thorsten Tjardes, Holger Bäthis, Sven Shafizadeh

    Knee joint infections constitute a rare but devastating complication after anterior cruciate ligament (ACL) reconstruction. We hypothesized that effective infection therapy and graft preservation is possible following a standard treatment protocol. We retrospectively analyzed all patients admitted to our center with suspected infection of the knee after ACL reconstruction between 2010 and 2012. Following a standardized protocol, blood samples were drawn and synovial fluid was analyzed. Furthermore, the protocol consisted of arthroscopic lavages and debridements of the anterior and posterior joint compartments over three incisions, and targeted antibiotic therapy over a period of 6 weeks. Surgeries were repeated every 2 days until clinical signs of infections resolved, but at least two times. Mean observation period was 10 months. Forty-one patients aged 31 ( ± 9.9) years and admitted 14 ( ± 7.5) days after ACL reconstruction were included. Pathogens were found in 34 patients and coagulase-negative staphylococci were isolated most commonly (31 isolates in 28 patients). Quinolones were the most commonly used antibiotic agents. Mean number of operations was 3.8 ( ± 1.4). Following the standard protocol, primary successful infection treatment with graft preservation was possible in 37 of the included 41 patients. Graft preservation was achieved in 100% of the included patients with Gaechter stage 1 and 2 infections. Knee joint infection after ACL reconstruction was successfully treated following a standardized protocol, and graft preservation was reliably achieved especially in cases with infections at an early stage.


  • Bacterial contamination of open fractures – pathogens, antibiotic resistances and therapeutic regimes in four hospitals of the trauma network Cologne, Germany

    by Robin Otchwemah, Volker Grams, Thorsten Tjardes, Sven Shafizadeh, Holger Bäthis, Marc Maegele, Sabine Messler, Bertil Bouillon, Christian Probst


  • Open Access

    Less than full circumferential fusion of a tibial nonunion is sufficient to achieve mechanically valid fusion - Proof of concept using a finite element modeling approach

    by Thorsten Tjardes, Michael Roland, Robin Otchwemah, Tim Dahmen, Stefan Diebels, Bertil Bouillon

    Although minimally invasive approaches are widely used in many areas of orthopedic surgery nonunion therapy remains a domain of open surgery. Some attempts have been made to introduce minimally invasive procedures into nonunion therapy. However, these proof of concept studies showed fusion rates comparable to open approaches never gaining wider acceptance in the clinical community. We hypothesize that knowledge of mechanically relevant regions of a nonunion might reduce the complexity of percutaneous procedures, especially in complex fracture patterns, and further reduce the amount of cancellous bone that needs to be transplanted. The aim of this investigation is to provide a proof of concept concerning the hypothesis that mechanically stable fusion of a nonunion can be achieved with less than full circumferential fusion. CT data of an artificial tibia with a complex fracture pattern and anatomical LCP are converted into a finite element mesh. The nonunion area is segmented. The finite element mesh is assigned mechanical properties according to data from the literature. An optimization algorithm is developed that reduces the number of voxels in the non union area until the scaled von Mises stress in the implant reaches 20% of the maximum stress in the implant/bone system that occurs with no fusion in the nonunion area at all. After six iterations of the optimization algorithm the number of voxels in the nonunion area is reduced by 96.4%, i.e. only 3.6% of voxels in the non union area are relevant for load transfer such that the von Mises stress in the implant/bone system does not exceed 20% of the maximal scaled von Mises stress occurring in the system with no fusion in the non union area at all. The hypothesis that less than full circumferential fusion is necessary for mechanical stability of a nonunion is confirmed. As the model provides only qualitative information the observed reduction of fusion area may not be taken literally but needs to be calibrated in future experiments. However this proof of concept provides the mechanical foundation for further development of minimally invasive approaches to delayed union and nonunion therapy.