Wen Jie Choy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wen Jie Choy has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Ralph Jasper Mobbs
Faculty of Medicine, University of New South Wales (UNSW), Sydney, Australia
9 shared publications Kevin Phan
NeuroSpine Surgery Research Group (NSURG), Prince of Wales Private Hospital, Randwick, Sydney, New South Wales, Australia; NeuroSpine Clinic, Department of Neurosurgery, Prince of Wales Private Hospital, Randwick, Sydney, New South Wales, Australia; Faculty of Medicine, University of New South Wales (UNSW), Randwick, Sydney, New South Wales, Australia
6 shared publications- Kevin Phan
Department of Dermatology, Liverpool Hospital, Sydney, Australia
4 shared publications Andrew Lennox
2 shared publications- Callum Betteridge
NeuroSpine Clinic, Prince of Wales Private Hospital, Randwick, Australia
2 shared publications Lachlan Cassar
University of New South Wales, Sydney, New South Wales, Australia; NeuroSpine Surgery Research Group, Sydney, New South Wales, Australia; NeuroSpine Clinic, Prince of Wales Private Hospital, Randwick, New South Wales, Australia
2 shared publications
Latest Publications
- Open Access
- 1 September 2021
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 7 (3) , 254-268
Objectifying clinical gait assessment: using a single-point wearable sensor to quantify the spatiotemporal gait metrics of people with lumbar spinal stenosis
Objectifying clinical gait assessment: using a single-point wearable sensor to quantify the spatiotemporal gait metrics of people with lumbar spinal stenosis Callum Betteridge, Ralph J. Mobbs, R. Dineth Fonseka, Pragadesh Natarajan, Daniel Ho, Wen Jie Choy, Luke W. Sy, Nina Pell
- 1 September 2021
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 7 (3) , 254-268
Open AccessObjectifying clinical gait assessment: using a single-point wearable sensor to quantify the spatiotemporal gait metrics of people with lumbar spinal stenosis
Objectifying clinical gait assessment: using a single-point wearable sensor to quantify the spatiotemporal gait metrics of people with lumbar spinal stenosis Callum Betteridge, Ralph J. Mobbs, R. Dineth Fonseka, Pragadesh Natarajan, Daniel Ho, Wen Jie Choy, Luke W. Sy, Nina Pell
- 1 October 2020
- Published by Elsevier in World Neurosurgery
- Vol. 142, e111-e116
Assessment and Post-Intervention Recovery After Surgery for Lumbar Disk Herniation Based on Objective Gait Metrics from Wearable Devices Using the Gait Posture Index
- 1 October 2020
- Published by Elsevier in World Neurosurgery
- Vol. 142, e111-e116
Assessment and Post-Intervention Recovery After Surgery for Lumbar Disk Herniation Based on Objective Gait Metrics from Wearable Devices Using the Gait Posture Index
- 1 March 2020
- Published by Elsevier in World Neurosurgery
- Vol. 135, e321-e332
Three-Dimensional Morphometric Analysis of Lumbar Vertebral End Plate Anatomy
- 1 March 2020
- Published by Elsevier in World Neurosurgery
- Vol. 135, e321-e332
Three-Dimensional Morphometric Analysis of Lumbar Vertebral End Plate Anatomy
- 1 December 2019
- Published by Elsevier in World Neurosurgery
- Vol. 132, 75-80
Three-Dimensional Planning and Patient-Specific Drill Guides for Repair of Spondylolysis/L5 Pars Defect
- 1 December 2019
- Published by Elsevier in World Neurosurgery
- Vol. 132, 75-80
Three-Dimensional Planning and Patient-Specific Drill Guides for Repair of Spondylolysis/L5 Pars Defect
- Open Access
- 15 June 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 288
The role of wearable devices and objective gait analysis for the assessment and monitoring of patients with lumbar spinal stenosis: systematic review
The purpose of this systematic review was to evaluate the accuracy and reliability of wearable devices for objective gait measurement of Lumbar Spinal Stenosis (LSS) patients, with a focus on relevant gait metrics. Systematic searches were conducted of five electronic databases to identify studies that assessed gait metrics by wearable or portable technology. Data was collected according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) statement guidelines. Four articles were identified for inclusion in this review. The objectives, methodology and quality of the studies varied. No single gait metric was investigated in all four studies, making comparison difficult. The most relevant metrics reported included gait cycle, gait velocity, step length and cadence, which were reported in two studies. Two studies explored gait symmetry. Differences between LSS patients and normal healthy subjects are demonstrable using wearable technology. The measurements of gait cycle, cadence, step length, gait velocity, and number of steps with wearable devices can be used in the gait measurement of LSS patients for initial assessment, and objective outcomes following interventions. However, data and analysis are limited, and further studies are necessary to comment on reliability.
- 15 June 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 288
Open AccessThe role of wearable devices and objective gait analysis for the assessment and monitoring of patients with lumbar spinal stenosis: systematic review
The purpose of this systematic review was to evaluate the accuracy and reliability of wearable devices for objective gait measurement of Lumbar Spinal Stenosis (LSS) patients, with a focus on relevant gait metrics. Systematic searches were conducted of five electronic databases to identify studies that assessed gait metrics by wearable or portable technology. Data was collected according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) statement guidelines. Four articles were identified for inclusion in this review. The objectives, methodology and quality of the studies varied. No single gait metric was investigated in all four studies, making comparison difficult. The most relevant metrics reported included gait cycle, gait velocity, step length and cadence, which were reported in two studies. Two studies explored gait symmetry. Differences between LSS patients and normal healthy subjects are demonstrable using wearable technology. The measurements of gait cycle, cadence, step length, gait velocity, and number of steps with wearable devices can be used in the gait measurement of LSS patients for initial assessment, and objective outcomes following interventions. However, data and analysis are limited, and further studies are necessary to comment on reliability.
- Open Access
- 9 June 2019
- Published by Wiley in Orthopaedic Surgery
- Vol. 11 (3) , 510-515
Technical Note: Pedicle Cement Augmentation with Proximal Screw Toggle and Loosening
Background: Cement augmentation is a technique used to increase the stability and purchase of pedicle screws in poor quality bone. Various methods can be applied for cement delivery, such as cement injection before screw placement and the use of fenestrated screws. However, potential problems can arise with the use of cement augmentation.Case Presentation: A 66‐year‐old man with a lower trunk deformity, severe kyphosis, and sagittal imbalance following fusion (L2‐5), with minimal comorbidities, was referred to our unit 9 months after surgery. Pain and progressive kyphosis were investigated clinically and radiographically with computed tomography (CT) scans to assess the status of the hardware and fusion. CT imaging revealed that cement was present only at the distal tip of the fenestrated screws at the L4 vertebral level. A non‐union was present along with loosening and a halo around the body of the pedicle screws, and there was evidence of pullout of inferior screws.Conclusion: Single‐level cement augmentation of pedicle screw in a posterior construct and distal tip cement augmentation of the screw results in a fixed pivot point. Micromotion in cranio‐caudal loading during flexion and extension may result in screw toggling with the single‐level cement‐augmented tip as a fulcrum. This may cause screw loosening, which can lead to pullout and loss of construct stability. The halo around the screw suggests bone loss and/or a fibrous tissue interface, which further complicates revision surgery. Stress shielding and polymethylmethacrylate cement present additional difficulties.The findings of this technical note question the risks and benefits of cement‐augmented fenestrated pedicle screw fixation for spinal fusion. Although incidences of such cases are uncommon, surgeons should perform this technique with caution. Accurate restoration of lumbar lordosis during index procedures is important to minimize the risk of construct failure.
- 9 June 2019
- Published by Wiley in Orthopaedic Surgery
- Vol. 11 (3) , 510-515
Open AccessTechnical Note: Pedicle Cement Augmentation with Proximal Screw Toggle and Loosening
Background: Cement augmentation is a technique used to increase the stability and purchase of pedicle screws in poor quality bone. Various methods can be applied for cement delivery, such as cement injection before screw placement and the use of fenestrated screws. However, potential problems can arise with the use of cement augmentation.Case Presentation: A 66‐year‐old man with a lower trunk deformity, severe kyphosis, and sagittal imbalance following fusion (L2‐5), with minimal comorbidities, was referred to our unit 9 months after surgery. Pain and progressive kyphosis were investigated clinically and radiographically with computed tomography (CT) scans to assess the status of the hardware and fusion. CT imaging revealed that cement was present only at the distal tip of the fenestrated screws at the L4 vertebral level. A non‐union was present along with loosening and a halo around the body of the pedicle screws, and there was evidence of pullout of inferior screws.Conclusion: Single‐level cement augmentation of pedicle screw in a posterior construct and distal tip cement augmentation of the screw results in a fixed pivot point. Micromotion in cranio‐caudal loading during flexion and extension may result in screw toggling with the single‐level cement‐augmented tip as a fulcrum. This may cause screw loosening, which can lead to pullout and loss of construct stability. The halo around the screw suggests bone loss and/or a fibrous tissue interface, which further complicates revision surgery. Stress shielding and polymethylmethacrylate cement present additional difficulties.The findings of this technical note question the risks and benefits of cement‐augmented fenestrated pedicle screw fixation for spinal fusion. Although incidences of such cases are uncommon, surgeons should perform this technique with caution. Accurate restoration of lumbar lordosis during index procedures is important to minimize the risk of construct failure.
- 1 April 2019
- Published by Elsevier in World Neurosurgery
- Vol. 124, 452-458.e1
Anterior Lumbar Interbody Fusion Using a Personalized Approach: Is Custom the Future of Implants for Anterior Lumbar Interbody Fusion Surgery?
- 1 April 2019
- Published by Elsevier in World Neurosurgery
- Vol. 124, 452-458.e1
Anterior Lumbar Interbody Fusion Using a Personalized Approach: Is Custom the Future of Implants for Anterior Lumbar Interbody Fusion Surgery?
- 1 February 2019
- Published by Elsevier in World Neurosurgery
- Vol. 122, 674-679
Three-Dimensional Patient-Specific Guides for Intraoperative Navigation for Cortical Screw Trajectory Pedicle Fixation
- 1 February 2019
- Published by Elsevier in World Neurosurgery
- Vol. 122, 674-679
Three-Dimensional Patient-Specific Guides for Intraoperative Navigation for Cortical Screw Trajectory Pedicle Fixation
- 1 December 2018
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 4 (4) , 757-769
3-dimensional printing for anterior cervical surgery: a review
Age-related degenerative changes and non-spondylotic pathologies of the cervical spine such as trauma and tumor can lead to compression of neurological structures and result in substantial alteration of the structural anatomy. The end-goal of surgical intervention is to decompress the neural structures which can be achieved via an anterior or a posterior approach, and stabilization of segments to restore stability and alignment. Three-dimensional printing (3DP or Additive Manufacturing) has been applied to the field of medicine, in particular orthopedics and neurosurgery. Coupled with advances of medical imaging such as computed tomography (CT) scans and magnetic resonance imaging (MRI), accurate 3D models of patient anatomy can be produced, and patient-specific implants (PSIs) for complex anatomical reconstruction have all been applied with positive outcomes. 3D printed implants have been applied in particular to the cervical spine predominantly due to the complex and relatively small osteological anatomy and the proximity of important neurovascular structures to the surgical sites. The purpose of this review is to evaluate the current application of 3DP for cervical spinal implants. This includes a review on the available literature on 3D printed PSIs and current available 3D printed “off-the-shelf” (OTS) implants (3D-OTS). Suitable materials for 3DP of spinal implants and the future prospect of cervical implants will be discussed. The review will be concluded with a suggested guide for carrying future studies to evaluate the efficacy and safety of 3DP for cervical spinal implants.
- 1 December 2018
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 4 (4) , 757-769
3-dimensional printing for anterior cervical surgery: a review
Age-related degenerative changes and non-spondylotic pathologies of the cervical spine such as trauma and tumor can lead to compression of neurological structures and result in substantial alteration of the structural anatomy. The end-goal of surgical intervention is to decompress the neural structures which can be achieved via an anterior or a posterior approach, and stabilization of segments to restore stability and alignment. Three-dimensional printing (3DP or Additive Manufacturing) has been applied to the field of medicine, in particular orthopedics and neurosurgery. Coupled with advances of medical imaging such as computed tomography (CT) scans and magnetic resonance imaging (MRI), accurate 3D models of patient anatomy can be produced, and patient-specific implants (PSIs) for complex anatomical reconstruction have all been applied with positive outcomes. 3D printed implants have been applied in particular to the cervical spine predominantly due to the complex and relatively small osteological anatomy and the proximity of important neurovascular structures to the surgical sites. The purpose of this review is to evaluate the current application of 3DP for cervical spinal implants. This includes a review on the available literature on 3D printed PSIs and current available 3D printed “off-the-shelf” (OTS) implants (3D-OTS). Suitable materials for 3DP of spinal implants and the future prospect of cervical implants will be discussed. The review will be concluded with a suggested guide for carrying future studies to evaluate the efficacy and safety of 3DP for cervical spinal implants.