Maryam Saeedifard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Maryam Saeedifard has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- Suman Debnath
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
10 shared publications Xifan Wang
Xi’an Jiaotong University
10 shared publications- Haitao Zhang
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China
9 shared publications - Mahmoud Mehrabankhomartash
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
9 shared publications - Changsong Cai
Hubei Key Laboratory of Power Equipment and System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
7 shared publications - Pengcheng Zhang
Department of Electrical Engineering, Tsinghua University, Beijing, China
7 shared publications
Latest Publications
- 1 January 2027
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 42 (1) , 84-87
Editorial 2027: Celebrating 40 Years of PELS
- 1 January 2027
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 42 (1) , 84-87
Editorial 2027: Celebrating 40 Years of PELS
- Open Access
- 11 November 2026
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 5 (1) , 53
Real-time machine learning control of a Hall thruster discharge plasma
- 11 November 2026
- Published by Springer Nature in Journal of Electric Propulsion
- Vol. 5 (1) , 53
Open AccessReal-time machine learning control of a Hall thruster discharge plasma
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (7) , 10491-10495
Anti-Diagonal Mapping Relationship of dq -Admittance and Frequency–Voltage Stability
The increasing penetration of inverter-based resources (IBRs) aggravates harmonic, frequency and voltage instability in modern power systems. While harmonic stability has been extensively studied, the theoretical understanding of frequency–voltage stability remains limited. This letter investigates system frequency and voltage dynamics under power disturbances by the PQ/ωU transfer function, and uncovers the anti-diagonal mapping relationship between dq-admittance and frequency–voltage stability. The results reveal that a main diagonally dominant dq-admittance implies that the system frequency and voltage are primarily impacted by reactive and active power, respectively. Conversely, an anti-diagonally dominant dq-admittance indicates that frequency and voltage are more sensitive to active and reactive power, respectively. The proposed theory enables frequency–voltage stability assessment based on the dominance pattern of dq-admittance, providing a new perspective for understanding frequency and voltage dynamics. The analysis is validated using three representative IBR-based test systems.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (7) , 10491-10495
Anti-Diagonal Mapping Relationship of dq -Admittance and Frequency–Voltage Stability
The increasing penetration of inverter-based resources (IBRs) aggravates harmonic, frequency and voltage instability in modern power systems. While harmonic stability has been extensively studied, the theoretical understanding of frequency–voltage stability remains limited. This letter investigates system frequency and voltage dynamics under power disturbances by the PQ/ωU transfer function, and uncovers the anti-diagonal mapping relationship between dq-admittance and frequency–voltage stability. The results reveal that a main diagonally dominant dq-admittance implies that the system frequency and voltage are primarily impacted by reactive and active power, respectively. Conversely, an anti-diagonally dominant dq-admittance indicates that frequency and voltage are more sensitive to active and reactive power, respectively. The proposed theory enables frequency–voltage stability assessment based on the dominance pattern of dq-admittance, providing a new perspective for understanding frequency and voltage dynamics. The analysis is validated using three representative IBR-based test systems.
- 24 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (1) , 4-6
Editorial 2026: Happy New Year TPEL!
- 24 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (1) , 4-6
Editorial 2026: Happy New Year TPEL!
- 31 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (6) , 5472-5485
Interactions of AGC Cyber-Attacks and Remedial Action Schemes in a Two-Area System
Automatic generation control (AGC) adjusts generator set-points through communication to maintain frequency stability and scheduled power transfer between neighboring areas of power systems. Due to cyber-vulnerabilities in communication networks, the AGC signal is susceptible to attacks, potentially leading to abnormal frequency deviations. This paper analyzes an attack strategy targeting AGC and the factors influencing its success. First, the paper outlines the attacker model and briefly reviews the feedback attack policy. Then, it examines the impact of power system parameters on the likelihood of a successful attack, using a decision tree algorithm, establishing guidelines to identify worst-case scenarios from a system operator’s perspective. Adhering to these guidelines can increase the probability of a successful attack, which is verified using phasor simulation with detailed turbine/governor and protection models. Additionally, the paper examines the attacker threat model, which identifies the attack surface required to steer the system frequency to an unsafe state while avoiding the activation of the remedial action scheme (RAS). If an attacker gains access, they could prevent the tripping of generator circuit breakers, thereby increasing the risk of a system-wide collapse and/or blackout.
- 31 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (6) , 5472-5485
Interactions of AGC Cyber-Attacks and Remedial Action Schemes in a Two-Area System
Automatic generation control (AGC) adjusts generator set-points through communication to maintain frequency stability and scheduled power transfer between neighboring areas of power systems. Due to cyber-vulnerabilities in communication networks, the AGC signal is susceptible to attacks, potentially leading to abnormal frequency deviations. This paper analyzes an attack strategy targeting AGC and the factors influencing its success. First, the paper outlines the attacker model and briefly reviews the feedback attack policy. Then, it examines the impact of power system parameters on the likelihood of a successful attack, using a decision tree algorithm, establishing guidelines to identify worst-case scenarios from a system operator’s perspective. Adhering to these guidelines can increase the probability of a successful attack, which is verified using phasor simulation with detailed turbine/governor and protection models. Additionally, the paper examines the attacker threat model, which identifies the attack surface required to steer the system frequency to an unsafe state while avoiding the activation of the remedial action scheme (RAS). If an attacker gains access, they could prevent the tripping of generator circuit breakers, thereby increasing the risk of a system-wide collapse and/or blackout.
- 14 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 14146-14158
A Parameter-Centric Approach for Enhancing Misalignment Tolerance in Wireless Power Transfer Systems
This article introduces a misalignment tolerance design method for wireless power transfer (WPT) systems by optimization of compensation network parameters. Leveraging the derivation of two-port impedance parameters and adjoint sensitivity analysis, the coupling misalignment characteristics of the system are assessed. Subsequently, a parameter-centric misalignment tolerant approach, independent of the coil structure, is established through a linear fitting method. The proposed approach ensures zero-voltage switching (ZVS) and facilitates efficient stable constant current (CC) output. Experimental validation is performed on a scaled-down 500-W rated SS-compensated WPT prototype equipped with nonspecialized square-shaped coils, demonstrating the effectiveness of the proposed approach. The proposed method enhances the SS-compensated system's ability to tolerate both horizontal and vertical misalignments, surpassing the performance of conventional SS topologies. Specifically, the system achieves over 85% efficiency within the misalignment tolerance range, with a peak efficiency of 93.2%. Additionally, the load current variation remains within 5.8% for 100 mm $x$-misalignment and $-$15 to $+$50 mm $z$-misalignment.
- 14 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 14146-14158
A Parameter-Centric Approach for Enhancing Misalignment Tolerance in Wireless Power Transfer Systems
This article introduces a misalignment tolerance design method for wireless power transfer (WPT) systems by optimization of compensation network parameters. Leveraging the derivation of two-port impedance parameters and adjoint sensitivity analysis, the coupling misalignment characteristics of the system are assessed. Subsequently, a parameter-centric misalignment tolerant approach, independent of the coil structure, is established through a linear fitting method. The proposed approach ensures zero-voltage switching (ZVS) and facilitates efficient stable constant current (CC) output. Experimental validation is performed on a scaled-down 500-W rated SS-compensated WPT prototype equipped with nonspecialized square-shaped coils, demonstrating the effectiveness of the proposed approach. The proposed method enhances the SS-compensated system's ability to tolerate both horizontal and vertical misalignments, surpassing the performance of conventional SS topologies. Specifically, the system achieves over 85% efficiency within the misalignment tolerance range, with a peak efficiency of 93.2%. Additionally, the load current variation remains within 5.8% for 100 mm $x$-misalignment and $-$15 to $+$50 mm $z$-misalignment.
- 11 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (6) , 4868-4881
A Unified Analysis Method for Harmonic and Frequency/Voltage Stability of Inverter- Integrated Power Systems
The large-scale integration of inverter-based resources (IBRs) in power systems increases the risk of harmonic instability and frequency/voltage instability. Traditionally, these two types of stability are handled separately by multifarious methods, and the relationship between them has not been thoroughly investigated. This paper addresses this gap by proving the equivalence between harmonic stability and frequency/voltage stability. On this basis, a unified analysis method for the two types of stability is formulated using the locally measured $\boldsymbol{dq}$ admittance model. Several key advantages are offered by the proposed method over existing approaches: 1) It enables black-box analysis of both stability types, protecting intellectual property and proprietary information; 2) It allows for concurrent analysis of both stability types, avoiding the trade-off between enhancing one type of stability at the expense of the other; 3) It captures dynamic features across the full frequency range, demonstrating superior accuracy in inverter-integrated power systems; 4) It reveals that $\boldsymbol{d}$-axis and $\boldsymbol{q}$-axis subsystem harmonic stability correspond to frequency and voltage stability, respectively. Finally, a series of case studies involving heterogeneous generation units and non-linear loads validate the accuracy and effectiveness of the proposed method.
- 11 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (6) , 4868-4881
A Unified Analysis Method for Harmonic and Frequency/Voltage Stability of Inverter- Integrated Power Systems
The large-scale integration of inverter-based resources (IBRs) in power systems increases the risk of harmonic instability and frequency/voltage instability. Traditionally, these two types of stability are handled separately by multifarious methods, and the relationship between them has not been thoroughly investigated. This paper addresses this gap by proving the equivalence between harmonic stability and frequency/voltage stability. On this basis, a unified analysis method for the two types of stability is formulated using the locally measured $\boldsymbol{dq}$ admittance model. Several key advantages are offered by the proposed method over existing approaches: 1) It enables black-box analysis of both stability types, protecting intellectual property and proprietary information; 2) It allows for concurrent analysis of both stability types, avoiding the trade-off between enhancing one type of stability at the expense of the other; 3) It captures dynamic features across the full frequency range, demonstrating superior accuracy in inverter-integrated power systems; 4) It reveals that $\boldsymbol{d}$-axis and $\boldsymbol{q}$-axis subsystem harmonic stability correspond to frequency and voltage stability, respectively. Finally, a series of case studies involving heterogeneous generation units and non-linear loads validate the accuracy and effectiveness of the proposed method.
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 8934-8938
Impact of DC Voltage Reference on Subsynchronous Dynamics in Grid-Forming Inverters
The influence of dc-side dynamics in grid-forming inverters has emerged as a critical area of study due to its implications for stability and control. A key yet unresolved question in the literature concerns the choice between measured and nominal dc voltage when determining the modulation index for the inverter's output voltage. This letter provides new insights into the distinct dynamic behaviors associated with these approaches. Through theoretical analysis, it demonstrates that the use of nominal dc voltage introduces unique low-frequency dynamics, leading to a previously unreported kind of subsynchronous oscillation. These oscillations, rooted in the interaction between dc-side dynamics and grid-forming control, pose potential challenges for system stability. Theoretical predictions are validated through hardware-in-the-loop studies.
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 8934-8938
Impact of DC Voltage Reference on Subsynchronous Dynamics in Grid-Forming Inverters
The influence of dc-side dynamics in grid-forming inverters has emerged as a critical area of study due to its implications for stability and control. A key yet unresolved question in the literature concerns the choice between measured and nominal dc voltage when determining the modulation index for the inverter's output voltage. This letter provides new insights into the distinct dynamic behaviors associated with these approaches. Through theoretical analysis, it demonstrates that the use of nominal dc voltage introduces unique low-frequency dynamics, leading to a previously unreported kind of subsynchronous oscillation. These oscillations, rooted in the interaction between dc-side dynamics and grid-forming control, pose potential challenges for system stability. Theoretical predictions are validated through hardware-in-the-loop studies.
- 13 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 11 (4) , 20-30
Cybersecurity Challenges in Low-Inertia Power-Electronics-Dominated Grids
The integration of renewable sources into the traditional grid requires a transition to a power electronics dominated grid (PEDG). One of the challenges facing a PEDG integration is the provision of voltage and frequency that can maintain system stability, through grid-forming distributed generation inverter to replace traditional synchronous generators. A significant challenge in implementing large-scale PEDGs lies in understanding the interactions between grid-forming inverters, particularly concerning system inertia. As synchronous generators are replaced with inertia-less inverters, the overall inherent inertia of the system decreases, potentially affecting grid stability. PEDGs and smart grids inherent dependence on communication networks for the successful integration and control of non-linear power electronic converters introduces cybersecurity vulnerabilities that malicious actors could exploit for financial or political gain, potentially destabilizing grid operations. This article highlights the effect of a cyber-attack on the performance of virtual synchronous generator control for a PEDG and provide key insight on some of the key research gaps, proposing a roadmap for future investigations. The study emphasizes the need for robust cybersecurity measures in PEDG implementations and highlights the importance of developing resilient control strategies that can maintain grid stability even under adverse conditions. This research contributes to the growing body of knowledge on secure and reliable operation of future power grids dominated by power electronics.
- 13 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 11 (4) , 20-30
Cybersecurity Challenges in Low-Inertia Power-Electronics-Dominated Grids
The integration of renewable sources into the traditional grid requires a transition to a power electronics dominated grid (PEDG). One of the challenges facing a PEDG integration is the provision of voltage and frequency that can maintain system stability, through grid-forming distributed generation inverter to replace traditional synchronous generators. A significant challenge in implementing large-scale PEDGs lies in understanding the interactions between grid-forming inverters, particularly concerning system inertia. As synchronous generators are replaced with inertia-less inverters, the overall inherent inertia of the system decreases, potentially affecting grid stability. PEDGs and smart grids inherent dependence on communication networks for the successful integration and control of non-linear power electronic converters introduces cybersecurity vulnerabilities that malicious actors could exploit for financial or political gain, potentially destabilizing grid operations. This article highlights the effect of a cyber-attack on the performance of virtual synchronous generator control for a PEDG and provide key insight on some of the key research gaps, proposing a roadmap for future investigations. The study emphasizes the need for robust cybersecurity measures in PEDG implementations and highlights the importance of developing resilient control strategies that can maintain grid stability even under adverse conditions. This research contributes to the growing body of knowledge on secure and reliable operation of future power grids dominated by power electronics.
- 19 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (7) , 6943-6956
A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)
The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.
- 19 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (7) , 6943-6956
A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)
The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.