Mingyang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mingyang Wang has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
Zhijian Jin
School of Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, People’s Republic of China
16 shared publications- Jie Sheng
Shanghai Jiao Tong University
10 shared publications Zhuyong Li
Energy Singularity Fusion Power Technology (Shanghai) Ltd, Shanghai 200131, People’s Republic of China
10 shared publications- Fangliang Dong
Chinese Academy of Sciences
9 shared publications - Junjie Jiang
School of Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
8 shared publications - Zhijian Jin
Shanghai Jiao Tong University
8 shared publications
Latest Publications
- 1 September 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (9) , 095014
Overcurrent behaviour and dynamic contact resistance of a semi-insulation HTS coil via plasma-deposited film
REBCO tapes are among the most promising high-temperature superconducting (HTS) materials for high-field applications. Their practical implementation typically involves wound coils, where the turn-to-turn insulation strategy significantly influences the electromagnetic response and self-protection behaviour. Conventional insulated coils provide well-defined current paths and fast magnetic-field responses, but they lack effective bypass-current channels. In contrast, no-insulation (NI) coils allow radial current bypass through turn-to-turn contacts, which improves self-protection by reducing local hot-spot growth. However, this radial current-sharing path also causes magnetic-field charging delay and makes the coil response sensitive to the turn-to-turn contact state. Therefore, a tunable turn-to-turn interface is expected to balance electromagnetic controllability and self-protection capability. In this study, we proposed HTS coils wound with atmospheric-pressure plasma jet-deposited film tapes. This plasma-deposited film may act as a semi-insulation turn-to-turn contact layer and introduces a condition-dependent effective contact resistance. During normal charging, the central magnetic field follows the transport current closely, indicating that radial current flow is suppressed. Under overcurrent tests, reproducible voltage disturbances and recoverable central-field responses are observed, suggesting a recoverable redistribution of transport current through radial contact paths in the plasma-film layer. A lumped magnetic-response model was first employed to estimate the global effective contact resistivity. An extended distributed radial-shunt model with dynamic contact resistance was then combined with a Monte Carlo framework to statistically evaluate representative spatial weak-contact hypotheses. The result demonstrates that spatially separated multi-site weak-contact regions are more consistent with the observed transient voltage spike and rapid recovery than a single weak region or a continuous radial channel. These findings suggest that the plasma film serves as a tunable semi-insulation turn-to-turn interface, providing a possible route to improve current distribution behaviour and self-protection capability in HTS coils.
- 1 September 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (9) , 095014
Overcurrent behaviour and dynamic contact resistance of a semi-insulation HTS coil via plasma-deposited film
REBCO tapes are among the most promising high-temperature superconducting (HTS) materials for high-field applications. Their practical implementation typically involves wound coils, where the turn-to-turn insulation strategy significantly influences the electromagnetic response and self-protection behaviour. Conventional insulated coils provide well-defined current paths and fast magnetic-field responses, but they lack effective bypass-current channels. In contrast, no-insulation (NI) coils allow radial current bypass through turn-to-turn contacts, which improves self-protection by reducing local hot-spot growth. However, this radial current-sharing path also causes magnetic-field charging delay and makes the coil response sensitive to the turn-to-turn contact state. Therefore, a tunable turn-to-turn interface is expected to balance electromagnetic controllability and self-protection capability. In this study, we proposed HTS coils wound with atmospheric-pressure plasma jet-deposited film tapes. This plasma-deposited film may act as a semi-insulation turn-to-turn contact layer and introduces a condition-dependent effective contact resistance. During normal charging, the central magnetic field follows the transport current closely, indicating that radial current flow is suppressed. Under overcurrent tests, reproducible voltage disturbances and recoverable central-field responses are observed, suggesting a recoverable redistribution of transport current through radial contact paths in the plasma-film layer. A lumped magnetic-response model was first employed to estimate the global effective contact resistivity. An extended distributed radial-shunt model with dynamic contact resistance was then combined with a Monte Carlo framework to statistically evaluate representative spatial weak-contact hypotheses. The result demonstrates that spatially separated multi-site weak-contact regions are more consistent with the observed transient voltage spike and rapid recovery than a single weak region or a continuous radial channel. These findings suggest that the plasma film serves as a tunable semi-insulation turn-to-turn interface, providing a possible route to improve current distribution behaviour and self-protection capability in HTS coils.
- 25 March 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (4)
Adaptive-extended modeling of superconducting magnets for hybrid energy storage integration in DC microgrids
With the increasing deployment of renewable energy sources, DC microgrids are becoming increasingly important owing to their strong capability of integrating such resources. Hybrid energy storage systems (HESSs) play a crucial role in mitigating the inherent uncertainties of renewable energy resources. Superconducting magnetic energy storage (SMES) constitutes a key component of HESSs due to its high energy conversion efficiency. Considering that the performance of SMES is inevitably influenced by the behavior of the magnet, and the electromagnetic environments arising from various operating conditions of DC microgrid would impact the superconducting magnets, it is necessary to investigate operating state of magnet under these conditions. Quantitative analysis of such responses remain scarce, and existing modeling efforts for DC microgrids containing HESS are either incomplete in calculation of superconducting properties or limited by computation efficiency. To address these limitations, this paper investigates the influences of renewable energy source fluctuations and faults-two representative operating conditions of DC microgrids-on the superconducting magnet within HESS. In order to achieve this objective, an adaptive-extended (AE) modeling framework is developed by coupling AE J-model with the simulated circuit, which enables the simultaneous capture of the dynamic interaction between superconducting properties and grid-level operating condition variations for the first time. The proposed AE modeling is validated through comparison with experimental results. Simulation results reveal the spatial distribution patterns of magnetic field and screening current induced stress (SCIS) under various operating conditions, and further show that a pole-to-pole short-circuit fault may impose Lorentz force on the magnet that exceed its irreversible stress limit. These findings offer valuable insights for magnet protection and enable targeted design strategies that avoid blindly increasing safety margins.
- 25 March 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (4)
Adaptive-extended modeling of superconducting magnets for hybrid energy storage integration in DC microgrids
With the increasing deployment of renewable energy sources, DC microgrids are becoming increasingly important owing to their strong capability of integrating such resources. Hybrid energy storage systems (HESSs) play a crucial role in mitigating the inherent uncertainties of renewable energy resources. Superconducting magnetic energy storage (SMES) constitutes a key component of HESSs due to its high energy conversion efficiency. Considering that the performance of SMES is inevitably influenced by the behavior of the magnet, and the electromagnetic environments arising from various operating conditions of DC microgrid would impact the superconducting magnets, it is necessary to investigate operating state of magnet under these conditions. Quantitative analysis of such responses remain scarce, and existing modeling efforts for DC microgrids containing HESS are either incomplete in calculation of superconducting properties or limited by computation efficiency. To address these limitations, this paper investigates the influences of renewable energy source fluctuations and faults-two representative operating conditions of DC microgrids-on the superconducting magnet within HESS. In order to achieve this objective, an adaptive-extended (AE) modeling framework is developed by coupling AE J-model with the simulated circuit, which enables the simultaneous capture of the dynamic interaction between superconducting properties and grid-level operating condition variations for the first time. The proposed AE modeling is validated through comparison with experimental results. Simulation results reveal the spatial distribution patterns of magnetic field and screening current induced stress (SCIS) under various operating conditions, and further show that a pole-to-pole short-circuit fault may impose Lorentz force on the magnet that exceed its irreversible stress limit. These findings offer valuable insights for magnet protection and enable targeted design strategies that avoid blindly increasing safety margins.
- Open Access
- 16 December 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 11160
Real-time artificial intelligence for solid-state lithium metal batteries
Battery health often evolves from an initial regime of slow capacity decay to a fast decay regime, due to catastrophic electrochemical reactions to cause the battery failure. The signals of such failure, however, often emerge much earlier during cycling, an early detection of which may help prevent the failure through real-time adjustment of cycling procedures. Here we demonstrate the integration of machine learning module directly into electrochemical battery test stations to constantly detect the signals from battery current and voltage profiles, followed by reinforcement learning–based real-time adjustment of cycling procedures for greatly elongated battery lifetime. We use solid-state lithium metal batteries to demonstrate this proof-of-concept implementation of built-in intelligence for future battery management systems, leveraging their high current density and fast cycling to generate abundant data and greatly shorten the development feedback loop. This intelligent approach improves battery lifetime by 265% and accumulative specific energy based on active material by 250% at 80% state of health, which is achieved through an effective control of detrimental interface reactions. This work showcases a pathway toward real-time artificial intelligence control of batteries for longevity and safety beyond human expertise.
- 16 December 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 11160
Open AccessReal-time artificial intelligence for solid-state lithium metal batteries
Battery health often evolves from an initial regime of slow capacity decay to a fast decay regime, due to catastrophic electrochemical reactions to cause the battery failure. The signals of such failure, however, often emerge much earlier during cycling, an early detection of which may help prevent the failure through real-time adjustment of cycling procedures. Here we demonstrate the integration of machine learning module directly into electrochemical battery test stations to constantly detect the signals from battery current and voltage profiles, followed by reinforcement learning–based real-time adjustment of cycling procedures for greatly elongated battery lifetime. We use solid-state lithium metal batteries to demonstrate this proof-of-concept implementation of built-in intelligence for future battery management systems, leveraging their high current density and fast cycling to generate abundant data and greatly shorten the development feedback loop. This intelligent approach improves battery lifetime by 265% and accumulative specific energy based on active material by 250% at 80% state of health, which is achieved through an effective control of detrimental interface reactions. This work showcases a pathway toward real-time artificial intelligence control of batteries for longevity and safety beyond human expertise.
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Improved Interface Reliability and Critical Current Retention in Multifilamentary REBCO Tapes via a Plasma-Deposited Film
With the widespread application of high-temperature superconducting (HTS) REBCO tapes in energy, healthcare, and transportation, their operating environments have become increasingly complex, placing higher demands on stability. Although multifilamentary REBCO tapes can reduce AC loss, exposure of REBCO compounds without stabilizing layers leads to moisture-induced degradation and performance failure. This study proposes a plasma-driven film deposition method using an atmospheric pressure plasma jet (APPJ) with hexamethyldisiloxane (HMDSO) to enhance the hydrophobicity of REBCO tapes. Results show that after the plasma film deposition, the water contact angle (WCA) on the tape surface increases from 94° to 138°. A new Si-O-based film with a spherical cluster morphology was deposited onto the tape surface. Scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) confirms that the coating is primarily composed of Si and O rather than the underlying tape elements (Cu, Y, Ba). Furthermore, critical current retention tests revealed a degradation in the critical current of untreated multifilamentary REBCO tapes over time, while the samples treated with plasma-deposited films exhibited minimal variation, indicating excellent critical current stability. After liquid nitrogen bathing, the film maintains considerable stability in hydrophobicity performance and chemical composition, demonstrating the feasibility of the plasma film fabrication for hydrophobicity improvement of superconducting tapes. This study presents an effective plasma coating method to prevent hydrolysis in multifilamentary REBCO tapes, thereby enhancing their electrical stability performance and providing crucial technical support for the design of high-performance tapes.
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Improved Interface Reliability and Critical Current Retention in Multifilamentary REBCO Tapes via a Plasma-Deposited Film
With the widespread application of high-temperature superconducting (HTS) REBCO tapes in energy, healthcare, and transportation, their operating environments have become increasingly complex, placing higher demands on stability. Although multifilamentary REBCO tapes can reduce AC loss, exposure of REBCO compounds without stabilizing layers leads to moisture-induced degradation and performance failure. This study proposes a plasma-driven film deposition method using an atmospheric pressure plasma jet (APPJ) with hexamethyldisiloxane (HMDSO) to enhance the hydrophobicity of REBCO tapes. Results show that after the plasma film deposition, the water contact angle (WCA) on the tape surface increases from 94° to 138°. A new Si-O-based film with a spherical cluster morphology was deposited onto the tape surface. Scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) confirms that the coating is primarily composed of Si and O rather than the underlying tape elements (Cu, Y, Ba). Furthermore, critical current retention tests revealed a degradation in the critical current of untreated multifilamentary REBCO tapes over time, while the samples treated with plasma-deposited films exhibited minimal variation, indicating excellent critical current stability. After liquid nitrogen bathing, the film maintains considerable stability in hydrophobicity performance and chemical composition, demonstrating the feasibility of the plasma film fabrication for hydrophobicity improvement of superconducting tapes. This study presents an effective plasma coating method to prevent hydrolysis in multifilamentary REBCO tapes, thereby enhancing their electrical stability performance and providing crucial technical support for the design of high-performance tapes.
- 14 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. PP (10518223) , 1-5
Influence of Groove Layout on Screening Current Induced Field in Multifilamentary REBCO Stacks
REBCO magnets generate unavoidable screening currents during operation. The screening current effect causes severe damage to both the structural integrity and electromagnetic performance of the coil. Specifically, the screening current induced field (SCIF) leads to distortion and drift in the central magnetic field of the coil. The multifilamentary REBCO stack is a viable structure for suppressing SCIF. However, its complex internal striated architecture incurs high manufacturing challenges and costs. Based on the finite element models proposed with T-A formulation solving the vector potential of current and magnetic, the effect of stacking process and multifilamentary structure are firstly discussed in this research. Then we analyzed the influence of groove layouts on SCIF of multifilamentary stacks. The relevant results show that grooves in high current density regions can interrupt screening current loop and show superior suppressing effect. However, complex groove layout shows significant impact on the distribution of high current density areas under external magnetic field. In this study, we uncovered a phenomenon that adjacent grooves in multifilamentary HTS stack can exhibit an electromagnetic coupling effect. This effect may affect the optimization of groove layout for suppression effect on SCIF and manufacturing costs.
- 14 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. PP (10518223) , 1-5
Influence of Groove Layout on Screening Current Induced Field in Multifilamentary REBCO Stacks
REBCO magnets generate unavoidable screening currents during operation. The screening current effect causes severe damage to both the structural integrity and electromagnetic performance of the coil. Specifically, the screening current induced field (SCIF) leads to distortion and drift in the central magnetic field of the coil. The multifilamentary REBCO stack is a viable structure for suppressing SCIF. However, its complex internal striated architecture incurs high manufacturing challenges and costs. Based on the finite element models proposed with T-A formulation solving the vector potential of current and magnetic, the effect of stacking process and multifilamentary structure are firstly discussed in this research. Then we analyzed the influence of groove layouts on SCIF of multifilamentary stacks. The relevant results show that grooves in high current density regions can interrupt screening current loop and show superior suppressing effect. However, complex groove layout shows significant impact on the distribution of high current density areas under external magnetic field. In this study, we uncovered a phenomenon that adjacent grooves in multifilamentary HTS stack can exhibit an electromagnetic coupling effect. This effect may affect the optimization of groove layout for suppression effect on SCIF and manufacturing costs.
- 1 October 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (10) , 105016
Combined effects of fiber structure, coating and coupling methods on the fiber-optic quench response in HTS CORC cables
To enhance distributed optical fiber quench detection capabilities in high-temperature superconducting conductor-on-round-core (CORC) cables, the combined influence of fiber structure, coating material and thermal-coupling method is systematically investigated in this paper. A heat-transfer model linking Rayleigh-backscattering spectral shift with response time is established based on optical-frequency-domain reflectometry. Three experimental factors, coating, coupling method and fiber structure, are evaluated on a liquid-nitrogen test platform. An epoxy-impregnated, acrylate-coated bend-insensitive fiber improves the signal-to-noise ratio (SNR) by 38% and shortens the response time by 200 ms relative to a free bare fiber. These results offer practical insights for the selection of optical fiber types and coupling configurations for improving fiber-optic quench detection performance in CORC cables.
- 1 October 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (10) , 105016
Combined effects of fiber structure, coating and coupling methods on the fiber-optic quench response in HTS CORC cables
To enhance distributed optical fiber quench detection capabilities in high-temperature superconducting conductor-on-round-core (CORC) cables, the combined influence of fiber structure, coating material and thermal-coupling method is systematically investigated in this paper. A heat-transfer model linking Rayleigh-backscattering spectral shift with response time is established based on optical-frequency-domain reflectometry. Three experimental factors, coating, coupling method and fiber structure, are evaluated on a liquid-nitrogen test platform. An epoxy-impregnated, acrylate-coated bend-insensitive fiber improves the signal-to-noise ratio (SNR) by 38% and shortens the response time by 200 ms relative to a free bare fiber. These results offer practical insights for the selection of optical fiber types and coupling configurations for improving fiber-optic quench detection performance in CORC cables.
- 1 July 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (7) , 075025
Preliminary tests and numerical modeling of the multistage twisted HTS cables with high-current capacity
The Rare-Earth-Barium-Copper-Oxide (REBCO) tape, characterized by superior current density and irreversible field properties, serves as a prime candidate for high-temperature superconducting (HTS) cable construction. To enhance the current-carrying capacity under intense magnetic fields, researchers have developed various cabling techniques, including the utilization of stacked tapes. Among them, the multistage strategy combined with a twisted structure emerges as a promising approach, since its configuration enables a near-exponential current capacity scaling through incremental stage additions within a compact structure. In the design and evaluation of HTS cables, electromagnetic characteristics assessment is critical for ensuring system-wide stability. While numerical models are widely employed for electromagnetic behavior prediction, conventional approaches often encounter challenges such as mesh distortion and convergence issues in long-span complex cables. This study has successfully fabricated a two-stage twisted prototype cable, validating the structural feasibility of multistage designs and twisted configurations in high-current applications. Through preliminary tests and numerical modelings at frequencies ranging from 60 to 180 Hz, the cable demonstrates high current-carrying capabilities with great electromagnetic performance, where the total loss is only about 46% of the theoretical value. Besides, this research presents an electromagnetic model specifically tailored for multistage twisted cables. By integrating the microelement method, the model accounts for current flow deviations induced by torsion and spatial displacements between cable segments. The simulation results demonstrate robust agreement with experimental measurements and 3D model benchmarks.
- 1 July 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (7) , 075025
Preliminary tests and numerical modeling of the multistage twisted HTS cables with high-current capacity
The Rare-Earth-Barium-Copper-Oxide (REBCO) tape, characterized by superior current density and irreversible field properties, serves as a prime candidate for high-temperature superconducting (HTS) cable construction. To enhance the current-carrying capacity under intense magnetic fields, researchers have developed various cabling techniques, including the utilization of stacked tapes. Among them, the multistage strategy combined with a twisted structure emerges as a promising approach, since its configuration enables a near-exponential current capacity scaling through incremental stage additions within a compact structure. In the design and evaluation of HTS cables, electromagnetic characteristics assessment is critical for ensuring system-wide stability. While numerical models are widely employed for electromagnetic behavior prediction, conventional approaches often encounter challenges such as mesh distortion and convergence issues in long-span complex cables. This study has successfully fabricated a two-stage twisted prototype cable, validating the structural feasibility of multistage designs and twisted configurations in high-current applications. Through preliminary tests and numerical modelings at frequencies ranging from 60 to 180 Hz, the cable demonstrates high current-carrying capabilities with great electromagnetic performance, where the total loss is only about 46% of the theoretical value. Besides, this research presents an electromagnetic model specifically tailored for multistage twisted cables. By integrating the microelement method, the model accounts for current flow deviations induced by torsion and spatial displacements between cable segments. The simulation results demonstrate robust agreement with experimental measurements and 3D model benchmarks.
- Open Access
- 6 March 2025
- Published by Elsevier in Superconductivity
- Vol. 13
An adaptive-extended modeling to accelerate electromagnetic study and data generation in superconducting magnet applications
- 6 March 2025
- Published by Elsevier in Superconductivity
- Vol. 13
Open AccessAn adaptive-extended modeling to accelerate electromagnetic study and data generation in superconducting magnet applications
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Critical Current Optimization for Stacks of REBCO Tapes With Defects
The stack structure of REBCO tapes is an effective way to increase the current carrying capacity. However, under the influence of anisotropy and high aspect ratio, REBCO tape has a low utilization rate in the stack structure. The purpose of this paper is to optimize the stack structure to improve the utilization rate of REBCO tapes. In order to calculate the critical current in the electric network model of stacked structure, the J model is introduced first. Then, based on the electric network model, the influence of different stack structures (including normal REBCO tape and defective REBCO tape) on the critical current is analyzed. The optimized structure can carry more currents, which is conducive to the development of REBCO tape applications.
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Critical Current Optimization for Stacks of REBCO Tapes With Defects
The stack structure of REBCO tapes is an effective way to increase the current carrying capacity. However, under the influence of anisotropy and high aspect ratio, REBCO tape has a low utilization rate in the stack structure. The purpose of this paper is to optimize the stack structure to improve the utilization rate of REBCO tapes. In order to calculate the critical current in the electric network model of stacked structure, the J model is introduced first. Then, based on the electric network model, the influence of different stack structures (including normal REBCO tape and defective REBCO tape) on the critical current is analyzed. The optimized structure can carry more currents, which is conducive to the development of REBCO tape applications.
- 29 August 2024
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 37 (10) , 105007
Electromagnetic and thermal performance study on a canted stack of REBCO tapes
Due to the critical current limitation of a single rare-earth barium copper oxide (REBCO) tape, stacking methods are generally employed to increase the current carrying capacity in practical high-temperature superconducting (HTS) applications. However, the overall critical current is strongly dependent on the self-magnetic field, which is influenced by the geometrical arrangement of conductors in the stack. Due to their brittle ceramic properties, REBCO tapes are conventionally bent along the thickness side of the tape. However, the difference in bending radii of the outer and inner tape surfaces in the stack may lead to fracture deformation, thereby limiting the stacking number of REBCO tapes. To balance the stacking number with the bending issue, a canted stack is proposed as a variant of the normal stack for REBCO tapes. As a potential HTS intermediate component, it is imperative to conduct a comprehensive study on the electromagnetic and thermal performance of the canted stack. The unique geometrical arrangement of the canted stack introduces new factors that affect the critical current and transport AC loss. This paper concludes with the special influencing factors of canted stacks, including canted angle, stacking number, tape width, and spatial structure. The metal interleaving method is introduced for spatial distribution changing and thermal stability. Furthermore, orthogonal analysis is performed to elucidate the comprehensive correlation among these multiple factors. This study provides insights into the overall critical current and transport AC loss for different combinations of canted stack and establishes a predicting function for critical current to support the structural design of canted stacks. Based on the specific case study, the improved capability of the canted stack is confirmed by both experiments and simulations.
- 29 August 2024
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 37 (10) , 105007
Electromagnetic and thermal performance study on a canted stack of REBCO tapes
Due to the critical current limitation of a single rare-earth barium copper oxide (REBCO) tape, stacking methods are generally employed to increase the current carrying capacity in practical high-temperature superconducting (HTS) applications. However, the overall critical current is strongly dependent on the self-magnetic field, which is influenced by the geometrical arrangement of conductors in the stack. Due to their brittle ceramic properties, REBCO tapes are conventionally bent along the thickness side of the tape. However, the difference in bending radii of the outer and inner tape surfaces in the stack may lead to fracture deformation, thereby limiting the stacking number of REBCO tapes. To balance the stacking number with the bending issue, a canted stack is proposed as a variant of the normal stack for REBCO tapes. As a potential HTS intermediate component, it is imperative to conduct a comprehensive study on the electromagnetic and thermal performance of the canted stack. The unique geometrical arrangement of the canted stack introduces new factors that affect the critical current and transport AC loss. This paper concludes with the special influencing factors of canted stacks, including canted angle, stacking number, tape width, and spatial structure. The metal interleaving method is introduced for spatial distribution changing and thermal stability. Furthermore, orthogonal analysis is performed to elucidate the comprehensive correlation among these multiple factors. This study provides insights into the overall critical current and transport AC loss for different combinations of canted stack and establishes a predicting function for critical current to support the structural design of canted stacks. Based on the specific case study, the improved capability of the canted stack is confirmed by both experiments and simulations.