Nachiket Patel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Nachiket Patel has a total of 143 co-authors. Here are the top co-authors by number of shared publications:
- Richard R. Heuser
University of Arizona College of Medicine Phoenix Arizona USA
19 shared publications Krishnaswamy Chandrasekaran
Division of Cardiology, Mayo ClinicRochester Minnesota
10 shared publicationsAjay U. Mhatre
Vascular Heart and Lung Associates, Mesa, AZ, United States of America
8 shared publications- Timothy Edward Paterick
Aurora Health Care, United States
8 shared publications A. Jamil Tajik
Cardiac Specialty Centers, Aurora Health CareMilwaukeeWisconsin
7 shared publicationsAshish Pershad
Department of Cardiology Chandler Regional Medical Center Chandler Arizona USA
7 shared publications
Latest Publications
- 13 January 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 105 (4) , 938-950
Systematic Review and Meta‐Analysis of the Super High‐Pressure Balloon (SIS‐OPN) for Percutaneous Coronary Intervention
Introduction: The super high‐pressure NC balloon (OPN NC; SIS Medical AG, Winterthur, Switzerland) is increasingly used in percutaneous coronary intervention (PCI). We performed a systematic review and meta‐analysis of its efficacy and safety.Methods: A systematic review was conducted using PubMed and the Cochrane Library to identify studies using the OPN NC balloon in PCI. Procedural success, major adverse cardiac events (MACE), coronary perforation, and other complications were pooled using weighted means, confidence intervals (CI), and I² statistics for heterogeneity assessment.Results: Twenty‐nine studies (5 prospective including 2 randomized‐controlled trials, 12 retrospective, and 12 case reports) were included in the systematic review, of which 11 (3 prospective, 8 retrospective) were included in the meta‐analysis. Of the 1015 meta‐analysis patients, 50.7% presented with stable angina and 21.6% with an acute coronary syndrome. Mean lesion length was 22.8 ± 13.7 mm, the prevalence of moderate or severe calcification was 93.7%, and 40.4% of lesions were in‐stent. Procedural success was 95.1% (95% CI 89.3%−98.8% with significant heterogeneity: I² = 84.9%). The incidence of periprocedural MACE was 1.9% (95% CI 1.1%−2.8%, I² 86.9%), and the incidence of coronary perforation was 0.6% (95% CI 0.3%−1.5%, I² 87.2%).Conclusions: Use of the OPN NC balloon is associated with high success and acceptable complication rates. The heterogeneity of outcomes underscores the need for additional studies and standardized definitions.
- 13 January 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 105 (4) , 938-950
Systematic Review and Meta‐Analysis of the Super High‐Pressure Balloon (SIS‐OPN) for Percutaneous Coronary Intervention
Introduction: The super high‐pressure NC balloon (OPN NC; SIS Medical AG, Winterthur, Switzerland) is increasingly used in percutaneous coronary intervention (PCI). We performed a systematic review and meta‐analysis of its efficacy and safety.Methods: A systematic review was conducted using PubMed and the Cochrane Library to identify studies using the OPN NC balloon in PCI. Procedural success, major adverse cardiac events (MACE), coronary perforation, and other complications were pooled using weighted means, confidence intervals (CI), and I² statistics for heterogeneity assessment.Results: Twenty‐nine studies (5 prospective including 2 randomized‐controlled trials, 12 retrospective, and 12 case reports) were included in the systematic review, of which 11 (3 prospective, 8 retrospective) were included in the meta‐analysis. Of the 1015 meta‐analysis patients, 50.7% presented with stable angina and 21.6% with an acute coronary syndrome. Mean lesion length was 22.8 ± 13.7 mm, the prevalence of moderate or severe calcification was 93.7%, and 40.4% of lesions were in‐stent. Procedural success was 95.1% (95% CI 89.3%−98.8% with significant heterogeneity: I² = 84.9%). The incidence of periprocedural MACE was 1.9% (95% CI 1.1%−2.8%, I² 86.9%), and the incidence of coronary perforation was 0.6% (95% CI 0.3%−1.5%, I² 87.2%).Conclusions: Use of the OPN NC balloon is associated with high success and acceptable complication rates. The heterogeneity of outcomes underscores the need for additional studies and standardized definitions.
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 207-212
A Research Paper On The Electrical And Physical Characteristics Of FinFET Using LTspice
The Fin Field-Effect Transistor (FinFET) has emerged as a promising alternative to conventional CMOS (complementary metal-oxide-semiconductor) planar transistors in advanced semiconductor technology nodes. FinFET devices have significantly faster switching times and higher current density than planar CMOS technology. This paper presents a comprehensive study of the electrical and physical characteristics of FinFETs. The unique three-dimensional structure of FinFETs provides several advantages, including improved control over short-channel effects, reduced leakage currents, and enhanced scalability. The paper begins with an overview of the FinFET device architecture and its fabrication process. The electrical characteristics of FinFETs are investigated, focusing on key parameters such as threshold voltage (V th .), sub-threshold slope (S), drain-induced barrier lowering (DIBL), and drain current $(\mathbf{I}_{\mathrm{d}})$ . Special attention is given to the on/off current ratio $(\mathbf{I}_{\mathbf{on}}/\mathbf{I}_{\mathbf{off}})$ and the impact of these parameters on the device's switching efficiency and power consumption. The output I- V characteristics leads to significant production of channels by sub-threshold currents inherently. Effective mobility of charge carriers in the FinFET channel gives significant reviews on consideration of the coulomb, phonon and surface roughness scattering. The shape of the Fin layer in a FinFET can have a significant impact on its performance. The Fin layer refers to the three-dimensional fin structure that serves as the channel through which current flows in a FinFET. Optimizing the Fin layer shape is a critical aspect of FinFET design. It involves striking a balance between short-channel effects, gate control, series resistance, and contact resistance to achieve high-performance, low-power transistors suitable for advanced semiconductor technology nodes. Different FinFET based SRAM different circuits are developed and simulated by using open source L Tspice XVII Version.- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 207-212
A Research Paper On The Electrical And Physical Characteristics Of FinFET Using LTspice
The Fin Field-Effect Transistor (FinFET) has emerged as a promising alternative to conventional CMOS (complementary metal-oxide-semiconductor) planar transistors in advanced semiconductor technology nodes. FinFET devices have significantly faster switching times and higher current density than planar CMOS technology. This paper presents a comprehensive study of the electrical and physical characteristics of FinFETs. The unique three-dimensional structure of FinFETs provides several advantages, including improved control over short-channel effects, reduced leakage currents, and enhanced scalability. The paper begins with an overview of the FinFET device architecture and its fabrication process. The electrical characteristics of FinFETs are investigated, focusing on key parameters such as threshold voltage (V th .), sub-threshold slope (S), drain-induced barrier lowering (DIBL), and drain current $(\mathbf{I}_{\mathrm{d}})$ . Special attention is given to the on/off current ratio $(\mathbf{I}_{\mathbf{on}}/\mathbf{I}_{\mathbf{off}})$ and the impact of these parameters on the device's switching efficiency and power consumption. The output I- V characteristics leads to significant production of channels by sub-threshold currents inherently. Effective mobility of charge carriers in the FinFET channel gives significant reviews on consideration of the coulomb, phonon and surface roughness scattering. The shape of the Fin layer in a FinFET can have a significant impact on its performance. The Fin layer refers to the three-dimensional fin structure that serves as the channel through which current flows in a FinFET. Optimizing the Fin layer shape is a critical aspect of FinFET design. It involves striking a balance between short-channel effects, gate control, series resistance, and contact resistance to achieve high-performance, low-power transistors suitable for advanced semiconductor technology nodes. Different FinFET based SRAM different circuits are developed and simulated by using open source L Tspice XVII Version.- 12 July 2022
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 100 (1) , 113
Those pesky anomalous coronary arteries: The importance of recognition before surgical repair of congenital cardiac disease and those mysterious Q waves
Key Points: Most infants with tetralogy of Fallot have staged surgical repairs of this complex congenital cardiac anomaly. Coronary anomalies occur in a tetralogy about 5% of the time. The most common coronary anomaly in the tetralogy of Fallot is an anomalous takeoff of the left anterior descending coronary artery of the right coronary artery which can be plicated during complete repair of the defect when the obstructed RV outflow tract is surgically opened.
- 12 July 2022
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 100 (1) , 113
Those pesky anomalous coronary arteries: The importance of recognition before surgical repair of congenital cardiac disease and those mysterious Q waves
Key Points: Most infants with tetralogy of Fallot have staged surgical repairs of this complex congenital cardiac anomaly. Coronary anomalies occur in a tetralogy about 5% of the time. The most common coronary anomaly in the tetralogy of Fallot is an anomalous takeoff of the left anterior descending coronary artery of the right coronary artery which can be plicated during complete repair of the defect when the obstructed RV outflow tract is surgically opened.
- 1 March 2022
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 99 (4) , 1074
Physiologic liquid plumber: A novel treatment to facilitate crossing of chronic total occlusions
Key Points: MZ‐004 is a collagenase enzyme formulation that degrades collagen, a key component of CTOs Collagenase administered into the proximal CTO cap is safe and increased the success soft‐tipped guidewire crossing rates in CTOs There was no difference in CTO PCI success with collagenase versus placebo
- 1 March 2022
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 99 (4) , 1074
Physiologic liquid plumber: A novel treatment to facilitate crossing of chronic total occlusions
Key Points: MZ‐004 is a collagenase enzyme formulation that degrades collagen, a key component of CTOs Collagenase administered into the proximal CTO cap is safe and increased the success soft‐tipped guidewire crossing rates in CTOs There was no difference in CTO PCI success with collagenase versus placebo
- 1 December 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 98 (7) , 1240
Everything is outpatient these days: The new economics of sophisticated cardiovascular care
Key Points: Same‐day discharge (SDD) after percutaneous coronary intervention (PCI) is associated with reduced cost and increased patient satisfaction. This study demonstrates the safety of SDD after uncomplicated chronic total occlusion PCI via the forearm approach.
- 1 December 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 98 (7) , 1240
Everything is outpatient these days: The new economics of sophisticated cardiovascular care
Key Points: Same‐day discharge (SDD) after percutaneous coronary intervention (PCI) is associated with reduced cost and increased patient satisfaction. This study demonstrates the safety of SDD after uncomplicated chronic total occlusion PCI via the forearm approach.
- 9 August 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 98 (2) , 317-318
It is all about the beans: How chronic kidney disease can affect outcomes in peripheral intervention
- 9 August 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 98 (2) , 317-318
It is all about the beans: How chronic kidney disease can affect outcomes in peripheral intervention
- 1 August 2021
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 33 (8) , E679
Entrapped Coronary Arteries in Constrictive Pericarditis
Pericardial constriction can be present without pericardial calcium and often without pericardial thickening. This epicardial coronary artery motion abnormality due to entrapment in a thickened, fibrotic pericardium, is characteristic of constrictive pericarditis, and differentiates this entity from other close differential diagnoses, such as restrictive and dilated cardiomyopathy. Clinical Images from Journal of Invasive Cardiology. coronary artery imaging pericarditis
- 1 August 2021
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 33 (8) , E679
Entrapped Coronary Arteries in Constrictive Pericarditis
Pericardial constriction can be present without pericardial calcium and often without pericardial thickening. This epicardial coronary artery motion abnormality due to entrapment in a thickened, fibrotic pericardium, is characteristic of constrictive pericarditis, and differentiates this entity from other close differential diagnoses, such as restrictive and dilated cardiomyopathy. Clinical Images from Journal of Invasive Cardiology. coronary artery imaging pericarditis
- 5 July 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 98 (1) , 55-56
The death knell of bare metal stents: The Cobra stent's encouraging results with short‐term antiplatelet therapy
- 5 July 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 98 (1) , 55-56
The death knell of bare metal stents: The Cobra stent's encouraging results with short‐term antiplatelet therapy
- 11 May 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 97 (6) , 1194-1195
The enigma continues: Obesity in chronic total occlusion patients does not affect success or complications…but Americans are still too fat!
Key Points: Eighty‐five percent of patients undergoing chronic total occlusion (CTO) percutaneous coronary intervention (PCI) in the OPEN‐CTO registry were either overweight or obese. There is no difference in procedure success and outcomes between overweight and obese patients undergoing CTO PCI compared to normal weight. Overweight and obese patients derive similar health status benefits after CTO PCI.
- 11 May 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 97 (6) , 1194-1195
The enigma continues: Obesity in chronic total occlusion patients does not affect success or complications…but Americans are still too fat!
Key Points: Eighty‐five percent of patients undergoing chronic total occlusion (CTO) percutaneous coronary intervention (PCI) in the OPEN‐CTO registry were either overweight or obese. There is no difference in procedure success and outcomes between overweight and obese patients undergoing CTO PCI compared to normal weight. Overweight and obese patients derive similar health status benefits after CTO PCI.
- 14 April 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 97 (5) , 764-765
We can, but should we?
- 14 April 2021
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 97 (5) , 764-765
We can, but should we?