Linghai Kong
Research Subjects
Research Interests
Linghai Kong has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Jing Jin
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
5 shared publications - Chunxi Zhang
School of Instrumentation and Optoelectronic of Engineering, Beihang University, Beijing 100191, China
4 shared publications - Kun Ma
National Institute of Metrology, Beijing, China
4 shared publications - Ningfang Song
Beihang University
4 shared publications - Haoyang Li
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
3 shared publications - Longjie Tian
Beihang University
3 shared publications
Latest Publications
- 19 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 8508410
A Novel Unobservable Subspace Online Estimation Method Based on the Variable-Dimension Kalman Filter
Gyroscope scale factor errors play a critical role in determining the dynamic performance of fiber-optic inertial navigation systems and directly affect measurement accuracy. However, the observability of scale factor errors is highly maneuver-dependent, and unobservable subspaces may arise under insufficient excitation. Conventional approaches typically adopt high-dimensional Kalman filters to enhance estimation stability, which may retain weakly observable scale factor states and adversely affect overall filtering performance. In this study, a novel variable-dimension Kalman filtering algorithm is proposed. A gyroscope confidence factor derived from prior noise characteristics is introduced to assess maneuver sufficiency and autonomously identify unobservable scale factor states in real time. Unlike existing methods that rely on structural modification of system or measurement models, the proposed approach realizes online dimension adaptation solely through covariance initialization and propagation, preserving filter continuity and implementation simplicity. Experimental results demonstrate that the proposed method improves heading accuracy from 0.1° to 0.02° and achieves a horizontal positioning accuracy of 0.89 nmile/h, corresponding to a 55.5% performance enhancement compared with conventional fixed-dimensional filtering approaches.
- 19 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 8508410
A Novel Unobservable Subspace Online Estimation Method Based on the Variable-Dimension Kalman Filter
Gyroscope scale factor errors play a critical role in determining the dynamic performance of fiber-optic inertial navigation systems and directly affect measurement accuracy. However, the observability of scale factor errors is highly maneuver-dependent, and unobservable subspaces may arise under insufficient excitation. Conventional approaches typically adopt high-dimensional Kalman filters to enhance estimation stability, which may retain weakly observable scale factor states and adversely affect overall filtering performance. In this study, a novel variable-dimension Kalman filtering algorithm is proposed. A gyroscope confidence factor derived from prior noise characteristics is introduced to assess maneuver sufficiency and autonomously identify unobservable scale factor states in real time. Unlike existing methods that rely on structural modification of system or measurement models, the proposed approach realizes online dimension adaptation solely through covariance initialization and propagation, preserving filter continuity and implementation simplicity. Experimental results demonstrate that the proposed method improves heading accuracy from 0.1° to 0.02° and achieves a horizontal positioning accuracy of 0.89 nmile/h, corresponding to a 55.5% performance enhancement compared with conventional fixed-dimensional filtering approaches.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-13
Measurement Selection for Drone Swarm Cooperative Positioning Based on Fisher and Mutual Information
This study proposes a measurement selection and optimization method based on the joint evaluation of mutual information and Fisher information to address the problem of global optimal estimation degradation caused by quality differences in measurement information within cooperative positioning (CP) systems. First, an information entropy function for state estimation is constructed through Shannon's theorem, and a conditional entropy constraint model is established by integrating multi-source measurement data from the leader drones. This derivation yields a mutual information expression characterizing measurement contribution. Subsequently, a Fisher information matrix is formulated using second-order partial differential operations to enable dynamic credibility assessment of measurements. Building on this foundation, an optimized objective function is developed by fusing mutual information and Fisher information criteria, effectively mitigating inconsistent positioning accuracy induced by environmental interference and equipment failures. Simulation results demonstrate that when the leader's positioning accuracy or ranging sensor measurement precision degrades, the optimal measurement selection strategy enhances the global optimal estimation of CP algorithms. Experiments with drones equipped with MTI-630R inertial measurement unit (IMU) reveal that the proposed method compensates for the followers' positioning errors. This research establishes a novel information fusion framework for multi-agent cooperative measurement in dynamically uncertain environments, with optimization strategies extendable to distributed sensing systems such as drone swarms and intelligent transportation networks. The framework demonstrates significant potential for enhancing measurement consistency in complex operational scenarios.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-13
Measurement Selection for Drone Swarm Cooperative Positioning Based on Fisher and Mutual Information
This study proposes a measurement selection and optimization method based on the joint evaluation of mutual information and Fisher information to address the problem of global optimal estimation degradation caused by quality differences in measurement information within cooperative positioning (CP) systems. First, an information entropy function for state estimation is constructed through Shannon's theorem, and a conditional entropy constraint model is established by integrating multi-source measurement data from the leader drones. This derivation yields a mutual information expression characterizing measurement contribution. Subsequently, a Fisher information matrix is formulated using second-order partial differential operations to enable dynamic credibility assessment of measurements. Building on this foundation, an optimized objective function is developed by fusing mutual information and Fisher information criteria, effectively mitigating inconsistent positioning accuracy induced by environmental interference and equipment failures. Simulation results demonstrate that when the leader's positioning accuracy or ranging sensor measurement precision degrades, the optimal measurement selection strategy enhances the global optimal estimation of CP algorithms. Experiments with drones equipped with MTI-630R inertial measurement unit (IMU) reveal that the proposed method compensates for the followers' positioning errors. This research establishes a novel information fusion framework for multi-agent cooperative measurement in dynamically uncertain environments, with optimization strategies extendable to distributed sensing systems such as drone swarms and intelligent transportation networks. The framework demonstrates significant potential for enhancing measurement consistency in complex operational scenarios.
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Centroiding Error Compensation of Star Sensor Images for Hypersonic Navigation Based on Angular Distance
A celestial navigation system (CNS) can be integrated in vehicles to suppress the diverging error of the inertial navigation system (INS). However, the CNS is subjected to aero-thermo-optic effects in hypersonic environments that introduce large-scale centroiding errors in star sensor images and greatly reduce the star sample size, limiting the usefulness of the CNS for hypersonic vehicles. In this study, these difficulties were addressed by the development of a statistical model for measurement noise based on the angular distance so that the standard deviation of the measurement noise can be correlated with the star sample size. To compensate for the centroiding error, a variable-dimension pseudo-transient adaptive filter was designed where the initial R matrix is set according to the star sample size. A semi-physical experiment was conducted to evaluate the performance of the proposed method, and the results indicated that stable centroiding error compensation was achieved for extremely small star sample sizes. In particular, the proposed method compensated for up to 66.24% of random positioning error, which is a performance improvement of about 10% compared with conventional compensation methods.
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Centroiding Error Compensation of Star Sensor Images for Hypersonic Navigation Based on Angular Distance
A celestial navigation system (CNS) can be integrated in vehicles to suppress the diverging error of the inertial navigation system (INS). However, the CNS is subjected to aero-thermo-optic effects in hypersonic environments that introduce large-scale centroiding errors in star sensor images and greatly reduce the star sample size, limiting the usefulness of the CNS for hypersonic vehicles. In this study, these difficulties were addressed by the development of a statistical model for measurement noise based on the angular distance so that the standard deviation of the measurement noise can be correlated with the star sample size. To compensate for the centroiding error, a variable-dimension pseudo-transient adaptive filter was designed where the initial R matrix is set according to the star sample size. A semi-physical experiment was conducted to evaluate the performance of the proposed method, and the results indicated that stable centroiding error compensation was achieved for extremely small star sample sizes. In particular, the proposed method compensated for up to 66.24% of random positioning error, which is a performance improvement of about 10% compared with conventional compensation methods.
- Open Access
- 6 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (5) , 1-10
Design of Silicon Nitride Based TE-Pass Polarizer at 850 nm for Integrated Fiber Optic Gyroscope
In recent years, the rapid development of integrated optics provides a novel approach to realize miniaturized and lightweight fiber optic gyroscope (FOG). This paper proposes a TE-pass polarizer based on the silicon nitride on insulator (SNOI) platform operating at 850nm, whose insertion loss is lower than 1.02dB with the polarization extinction ratio (PER) larger than 47dB. The proposed polarizer could directly edge-couple to the thin film lithium niobate (TFLN) modulator with a negligible loss (<0.19dB) to form a combined hybrid modulator, which integrates the function of modulating, splitting, and polarizing. Compared with the traditional bulk lithium niobate modulator, the utilization of the hybrid modulator in FOGs could increase the optical power entering the fiber coil by 68% at 850nm, which greatly facilitates the improvement of FOG precision. Furthermore, the undesired residual intensity modulation effect in the bulk lithium niobate modulator is also theoretically avoided by employing the hybrid modulator.
- 6 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (5) , 1-10
Open AccessDesign of Silicon Nitride Based TE-Pass Polarizer at 850 nm for Integrated Fiber Optic Gyroscope
In recent years, the rapid development of integrated optics provides a novel approach to realize miniaturized and lightweight fiber optic gyroscope (FOG). This paper proposes a TE-pass polarizer based on the silicon nitride on insulator (SNOI) platform operating at 850nm, whose insertion loss is lower than 1.02dB with the polarization extinction ratio (PER) larger than 47dB. The proposed polarizer could directly edge-couple to the thin film lithium niobate (TFLN) modulator with a negligible loss (<0.19dB) to form a combined hybrid modulator, which integrates the function of modulating, splitting, and polarizing. Compared with the traditional bulk lithium niobate modulator, the utilization of the hybrid modulator in FOGs could increase the optical power entering the fiber coil by 68% at 850nm, which greatly facilitates the improvement of FOG precision. Furthermore, the undesired residual intensity modulation effect in the bulk lithium niobate modulator is also theoretically avoided by employing the hybrid modulator.
- 29 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (1) , 353-362
Self-Adaptive Suppression of the Excess Relative-Intensity-Noise in Fiber Optic Gyroscopes
The excess relative intensity noise (RIN) in the fiber optic gyroscope (FOG) can be suppressed by the balanced intensity addition of the interferometer output signal and the RIN reference. In practice, the suppression effect will be ruined by the mismatching of the intensities at addition induced by external environments, resulting in the degradation of the angular-random-walk (ARW) coefficient of the FOG. In this work, we propose a self-adaptive scheme to keep the excess-RIN suppressed at the lowest level. The multiple roles that the modulation depth plays in the loss of the interferometer output signal and the amplitude of each noise component are analyzed, theoretically. Based on this, the modulation depth is designed to be self-adjusted in a closed-loop scheme so as to keep intensity balancing and to maintain the total noise at the lowest level in real time. Experiments show that, under the manually adjusted intensity ratios between the interferometer output signal and the RIN reference from 0.42 to 3.25, the proposed self-adaptive scheme reduces the ARW to 1.24×10 -3 deg/h 1/2 with respect to the conventional case of 2.27×10 -3 deg/h 1/2 . With this technique, the robustness of the excess-RIN suppression is significantly improved without the need of modifying the typical simplest optical configuration or adding any extra device. The lowest ARW for the FOG can be guaranteed in long-term operations and under different environments.
- 29 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (1) , 353-362
Self-Adaptive Suppression of the Excess Relative-Intensity-Noise in Fiber Optic Gyroscopes
The excess relative intensity noise (RIN) in the fiber optic gyroscope (FOG) can be suppressed by the balanced intensity addition of the interferometer output signal and the RIN reference. In practice, the suppression effect will be ruined by the mismatching of the intensities at addition induced by external environments, resulting in the degradation of the angular-random-walk (ARW) coefficient of the FOG. In this work, we propose a self-adaptive scheme to keep the excess-RIN suppressed at the lowest level. The multiple roles that the modulation depth plays in the loss of the interferometer output signal and the amplitude of each noise component are analyzed, theoretically. Based on this, the modulation depth is designed to be self-adjusted in a closed-loop scheme so as to keep intensity balancing and to maintain the total noise at the lowest level in real time. Experiments show that, under the manually adjusted intensity ratios between the interferometer output signal and the RIN reference from 0.42 to 3.25, the proposed self-adaptive scheme reduces the ARW to 1.24×10 -3 deg/h 1/2 with respect to the conventional case of 2.27×10 -3 deg/h 1/2 . With this technique, the robustness of the excess-RIN suppression is significantly improved without the need of modifying the typical simplest optical configuration or adding any extra device. The lowest ARW for the FOG can be guaranteed in long-term operations and under different environments.
- 25 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Radiation-Induced Degradation Analysis and Reliability Modeling of COTS ADCs for Space-Borne Miniature Fiber-Optic Gyroscopes
Respecting the requirements of lightweight, small size, low power consumption and especially low cost, commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are gradually being used to replace specifically designed aerospace -grade ones in space-borne miniature interferometric fiber-optic gyroscopes (IFOGs). However, the total ionizing dose (TID) effect of $\gamma $ -ray radiation in the space environment may cause the damage of COTS ADCs, and lead to performance degradation and even the failure. In order to measure the safety of COTS ADCs in IFOGs under the TID effect, the radiation-induced degradation model and the corresponding reliability model are proposed in this work. First of all, the relationship between the degradation of COTS ADCs and the IFOG's angular random walk (ARW) is deduced. Then, a radiation accelerated test is designed and performed, with a real-time, dynamic data acquisition method based on the first-input-first-output (FIFO) memories to determine the degradation of COTS ADCs. Finally, a degradation path model is established based on the degradation data, and the reliability of COTS ADCs used for space-borne IFOGs is further obtained by using the Monte Carlo method. An engineering application is introduced to show the effectiveness of the proposed model, and the results show that the reliability of the experimental COTS ADCs makes them usable for the space-borne miniature IFOGs in low-earth orbit (LEO) and geostationary earth orbit (GEO) space missions.- 25 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Radiation-Induced Degradation Analysis and Reliability Modeling of COTS ADCs for Space-Borne Miniature Fiber-Optic Gyroscopes
Respecting the requirements of lightweight, small size, low power consumption and especially low cost, commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are gradually being used to replace specifically designed aerospace -grade ones in space-borne miniature interferometric fiber-optic gyroscopes (IFOGs). However, the total ionizing dose (TID) effect of $\gamma $ -ray radiation in the space environment may cause the damage of COTS ADCs, and lead to performance degradation and even the failure. In order to measure the safety of COTS ADCs in IFOGs under the TID effect, the radiation-induced degradation model and the corresponding reliability model are proposed in this work. First of all, the relationship between the degradation of COTS ADCs and the IFOG's angular random walk (ARW) is deduced. Then, a radiation accelerated test is designed and performed, with a real-time, dynamic data acquisition method based on the first-input-first-output (FIFO) memories to determine the degradation of COTS ADCs. Finally, a degradation path model is established based on the degradation data, and the reliability of COTS ADCs used for space-borne IFOGs is further obtained by using the Monte Carlo method. An engineering application is introduced to show the effectiveness of the proposed model, and the results show that the reliability of the experimental COTS ADCs makes them usable for the space-borne miniature IFOGs in low-earth orbit (LEO) and geostationary earth orbit (GEO) space missions.- 11 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 38 (23) , 6655-6663
A Compact Four-Axis Interferometric Fiber Optic Gyroscope Based on Multiplexing for Space Application
A compact quad interferometric fiber optic gyroscope (IFOG) is demonstrated for attitude determination in space application, which combines efficiently multiplexing technology with redundancy technology. Compared with existing typical three-axis and four-axis systems, the IFOG not only reduces greatly the size, weight, power consumption and cost, but also improves dramatically the reliability. Based on the configuration, a multiplexing modulation method and a control method are proposed. A prototype is manufactured, which achieves the angle random walk of less than 0.025 deg/h and the bias instability of less than 0.15 deg/h. The weight and power consumption of the prototype are 3.5 times and 2.6 times less than the existing system with roughly the same performance, respectively. The fault injection experiments are conducted and verify that the control method is available for fault recovery.
- 11 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 38 (23) , 6655-6663
A Compact Four-Axis Interferometric Fiber Optic Gyroscope Based on Multiplexing for Space Application
A compact quad interferometric fiber optic gyroscope (IFOG) is demonstrated for attitude determination in space application, which combines efficiently multiplexing technology with redundancy technology. Compared with existing typical three-axis and four-axis systems, the IFOG not only reduces greatly the size, weight, power consumption and cost, but also improves dramatically the reliability. Based on the configuration, a multiplexing modulation method and a control method are proposed. A prototype is manufactured, which achieves the angle random walk of less than 0.025 deg/h and the bias instability of less than 0.15 deg/h. The weight and power consumption of the prototype are 3.5 times and 2.6 times less than the existing system with roughly the same performance, respectively. The fault injection experiments are conducted and verify that the control method is available for fault recovery.
- 23 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (20) , 8361-8366
Efficient and Reliable Optical Power Monitoring in Miniaturized Interferometric Fiber Optic Gyroscopes for Space Application
As the developing of interferometric fiber optic gyroscopes (IFOGs) in space, optical power monitoring has received considerable attention. However, adding additional measuring units is the main used method for optical power monitoring right now which is inconsistent with the development trend of high reliability, low cost, and miniaturization of IFOGs. This paper presents a novel approach to the optical power monitoring in IFOGs without increasing any devices. The demodulated signals detected by a photodetector to field-programmable gate array are analyzed. The inverse-demodulation method based on the characteristic analysis of the demodulated signals is proposed the first time to realize the optical power monitoring with a linear relationship. A simple and all-digital scheme is designed and implemented in the first closed loops of IFOGs with no effects on the rotation rate sensing. The optical power monitoring strategy is verified by a series of experimental results. The results show that its measuring accuracy is about 0.025 uw. The demonstrated repeatability is less than 0.065 uw. The proposed method is efficient and reliable, which will make it more suitable for space applications.
- 23 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (20) , 8361-8366
Efficient and Reliable Optical Power Monitoring in Miniaturized Interferometric Fiber Optic Gyroscopes for Space Application
As the developing of interferometric fiber optic gyroscopes (IFOGs) in space, optical power monitoring has received considerable attention. However, adding additional measuring units is the main used method for optical power monitoring right now which is inconsistent with the development trend of high reliability, low cost, and miniaturization of IFOGs. This paper presents a novel approach to the optical power monitoring in IFOGs without increasing any devices. The demodulated signals detected by a photodetector to field-programmable gate array are analyzed. The inverse-demodulation method based on the characteristic analysis of the demodulated signals is proposed the first time to realize the optical power monitoring with a linear relationship. A simple and all-digital scheme is designed and implemented in the first closed loops of IFOGs with no effects on the rotation rate sensing. The optical power monitoring strategy is verified by a series of experimental results. The results show that its measuring accuracy is about 0.025 uw. The demonstrated repeatability is less than 0.065 uw. The proposed method is efficient and reliable, which will make it more suitable for space applications.
- Open Access
In-Orbit Performance Evaluation of a Spaceborne High Precision Fiber Optic Gyroscope
An in-orbit experiment was launched to evaluate the performance of the spaceborne high precision fiber optic gyroscopes (FOG). The three-axis in-orbit data of the FOG were analyzed using wavelet analysis method. Features of low frequency period terms and glitch noise were demonstrated. In addition, a method to extract the random noise from the in-orbit data is proposed based on the first-order difference method and the Pauta criterion. In addition, the random walk coefficient (RWC) of the FOG was calculated with the Allan variance method. Compared the ground test results, the in-orbit performance evaluation of Spaceborne High Precision Fiber Optic Gyroscope was verified.
Open AccessIn-Orbit Performance Evaluation of a Spaceborne High Precision Fiber Optic Gyroscope
An in-orbit experiment was launched to evaluate the performance of the spaceborne high precision fiber optic gyroscopes (FOG). The three-axis in-orbit data of the FOG were analyzed using wavelet analysis method. Features of low frequency period terms and glitch noise were demonstrated. In addition, a method to extract the random noise from the in-orbit data is proposed based on the first-order difference method and the Pauta criterion. In addition, the random walk coefficient (RWC) of the FOG was calculated with the Allan variance method. Compared the ground test results, the in-orbit performance evaluation of Spaceborne High Precision Fiber Optic Gyroscope was verified.