Naren Vikram Raj Masna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Naren Vikram Raj Masna has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Swarup Bhunia
University of Florida
8 shared publications - Soumyajit Mandal
Brookhaven National Laboratory
6 shared publications Cheng Chen
Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, Ohio, USA
4 shared publicationsSoumyajit Mandal
Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, Ohio, USA
3 shared publicationsFengchao Zhang
Department of Electrical and Computer Engineering University of Florida Gainesville FL 32611 USA
2 shared publications- Rohan Reddy Kalavakonda
Electrical and Computer Engineering Department, University of Florida, Gainesville, FL, USA
2 shared publications
Latest Publications
- 17 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computers
- Vol. 72 (10) , 2740-2751
A Framework for Automated Exploration of Trojan Attack Space in FPGA Netlists
Field Programmable Gate Arrays (FPGAs) provide a flexible compute platform for quick prototyping or hardware acceleration in diverse application domains. However, similar to the global semiconductor life-cycle in the modern supply chain, FPGA-based product development includes processes and interactions with potentially untrusted parties outside the traditional scrutiny of a completely in-house development cycle. An untrusted party or software can maliciously alter a hardware intellectual property (IP) block mapped to an FPGA device during various stages of the FPGA life-cycle. Such malicious alterations, also known as hardware Trojan attacks, have garnered significant research into their detection and prevention in the context of application-specific integrated circuit (ASIC) design flow. However, Trojan attacks in FPGAs have not enjoyed this same attention. Designers often rely on mapping ASIC-specific solutions and evaluation benchmarks to the FPGA domain, which leaves much of the FPGA-specific Trojan space uncovered. We note that the distinctive business model as well as the architectural configurations of FPGAs present unique opportunities for Trojan attacks to an adversary. To this end, we introduce a framework to automatically explore the hardware Trojan attack space in FPGA netlists. It is capable of inserting different types of FPGA-specific Trojans in a netlist enabling rapid exploration of potential Trojan attacks in an FPGA design: soft-template, monolithic, and distributed dark silicon. Soft template Trojans use behavioral templates with random synthesis constraints to increase Trojan structural diversity. Monolithic and distributed dark silicon Trojans use the under-utilized input space (FPGA dark silicon) in FPGA primitives to realize Trojans with effectively zero area and power footprint. Further optimizations are also presented to remove any potential delay impact. We then generate over 1300 Trojan-inserted benchmarks using each of the introduced FPGA Trojan classes, and compare their impact on utilization, delay, and power. Finally, we evaluate our Trojans against a machine learning-based Trojan detection to highlight their evasiveness.
- 17 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computers
- Vol. 72 (10) , 2740-2751
A Framework for Automated Exploration of Trojan Attack Space in FPGA Netlists
Field Programmable Gate Arrays (FPGAs) provide a flexible compute platform for quick prototyping or hardware acceleration in diverse application domains. However, similar to the global semiconductor life-cycle in the modern supply chain, FPGA-based product development includes processes and interactions with potentially untrusted parties outside the traditional scrutiny of a completely in-house development cycle. An untrusted party or software can maliciously alter a hardware intellectual property (IP) block mapped to an FPGA device during various stages of the FPGA life-cycle. Such malicious alterations, also known as hardware Trojan attacks, have garnered significant research into their detection and prevention in the context of application-specific integrated circuit (ASIC) design flow. However, Trojan attacks in FPGAs have not enjoyed this same attention. Designers often rely on mapping ASIC-specific solutions and evaluation benchmarks to the FPGA domain, which leaves much of the FPGA-specific Trojan space uncovered. We note that the distinctive business model as well as the architectural configurations of FPGAs present unique opportunities for Trojan attacks to an adversary. To this end, we introduce a framework to automatically explore the hardware Trojan attack space in FPGA netlists. It is capable of inserting different types of FPGA-specific Trojans in a netlist enabling rapid exploration of potential Trojan attacks in an FPGA design: soft-template, monolithic, and distributed dark silicon. Soft template Trojans use behavioral templates with random synthesis constraints to increase Trojan structural diversity. Monolithic and distributed dark silicon Trojans use the under-utilized input space (FPGA dark silicon) in FPGA primitives to realize Trojans with effectively zero area and power footprint. Further optimizations are also presented to remove any potential delay impact. We then generate over 1300 Trojan-inserted benchmarks using each of the introduced FPGA Trojan classes, and compare their impact on utilization, delay, and power. Finally, we evaluate our Trojans against a machine learning-based Trojan detection to highlight their evasiveness.
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (23) , 23129-23136
MASI: A Novel Combination of Mask and Shield With Near-N95 Efficiency
Mask wearing has become critical for preventing the aerosolization and inhalation of virus-laden particles during the ongoing COVID-19 global pandemic. However, facial masks with effective filtration are either not readily accessible ( e.g ., N95) or have reduced filtration efficiency due to air gaps between the mask and wearer (e.g., cloth masks). We have developed a novel combination of a mask and shield named Mask And Shield Integrated (MASI) that provides nearly the same levels of protection as an N95 mask by addressing these issues. Magnetic latches reduce gaps between the mask and wearer, while a novel fin structure on the shield provides protection against floating particles. A series of experiments was performed to study MASI’s efficacy in both eliminating mask gaps and also providing N95-like filtration efficiency. MASI was found to solve both problems, thus providing a low-cost mask solution that can be applied to a broad range of environments to prevent inhalation of small air-borne particles.
- 10 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (23) , 23129-23136
MASI: A Novel Combination of Mask and Shield With Near-N95 Efficiency
Mask wearing has become critical for preventing the aerosolization and inhalation of virus-laden particles during the ongoing COVID-19 global pandemic. However, facial masks with effective filtration are either not readily accessible ( e.g ., N95) or have reduced filtration efficiency due to air gaps between the mask and wearer (e.g., cloth masks). We have developed a novel combination of a mask and shield named Mask And Shield Integrated (MASI) that provides nearly the same levels of protection as an N95 mask by addressing these issues. Magnetic latches reduce gaps between the mask and wearer, while a novel fin structure on the shield provides protection against floating particles. A series of experiments was performed to study MASI’s efficacy in both eliminating mask gaps and also providing N95-like filtration efficiency. MASI was found to solve both problems, thus providing a low-cost mask solution that can be applied to a broad range of environments to prevent inhalation of small air-borne particles.
- 30 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (2) , 1670-1679
A Wearable Skin Temperature Monitoring System for Early Detection of Infections
This paper describes a wearable, open-source wrist temperature monitoring system that enables the reliable identification of slowly-varying skin temperature patterns that may be indicative of infections. The hardware platform uses a Bluetooth Low Energy (BLE) wireless interface and includes three skin temperature sensors, a thermally-isolated ambient temperature sensor, an inertial measurement unit (IMU), and a Galvanic skin response (GSR) sensor. A template-matching algorithm is used to detect weak but long-lived anomalous temperature patterns that deviate from the normal circadian rhythm are thus may be driven by infections. Experimental and simulation results confirm that small temperature anomalies (peak value < 0.4°C) extending over 2-3 weeks can be detected with a total error rate < 10%.
- 30 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (2) , 1670-1679
A Wearable Skin Temperature Monitoring System for Early Detection of Infections
This paper describes a wearable, open-source wrist temperature monitoring system that enables the reliable identification of slowly-varying skin temperature patterns that may be indicative of infections. The hardware platform uses a Bluetooth Low Energy (BLE) wireless interface and includes three skin temperature sensors, a thermally-isolated ambient temperature sensor, an inertial measurement unit (IMU), and a Galvanic skin response (GSR) sensor. A template-matching algorithm is used to detect weak but long-lived anomalous temperature patterns that deviate from the normal circadian rhythm are thus may be driven by infections. Experimental and simulation results confirm that small temperature anomalies (peak value < 0.4°C) extending over 2-3 weeks can be detected with a total error rate < 10%.
- Open Access
Detecting Dye-Contaminated Vegetables Using Low-Field NMR Relaxometry
Dyeing vegetables with harmful compounds has become an alarming public health issue over the past few years. Excessive consumption of these dyed vegetables can cause severe health hazards, including cancer. Copper sulfate, malachite green, and Sudan red are some of the non-food-grade dyes widely used on vegetables by untrusted entities in the food supply chain to make them look fresh and vibrant. In this study, the presence and quantity of dye-based adulteration in vegetables are determined by applying 1H-nuclear magnetic resonance (NMR) relaxometry. The proposed technique was validated by treating some vegetables in-house with different dyes and then soaking them in various solvents. The resulting solutions were collected and analyzed using NMR relaxometry. Specifically, the effective transverse relaxation time constant, T2,eff, of each solution was estimated using a Carr–Purcell–Meiboom–Gill (CPMG) pulse sequence. Finally, the estimated time constants (i.e., measured signatures) were compared with a library of existing T2,eff data to detect and quantify the presence of unwanted dyes. The latter consists of data-driven models of transverse decay times for various concentrations of each water-soluble dye. The time required to analyze each sample using the proposed approach is dye-dependent but typically no longer than a few minutes. The analysis results can be used to generate warning flags if the detected dye concentrations violate widely accepted standards for food dyes. The proposed low-cost detection approach can be used in various stages of a produce supply chain, including consumer household.
Open AccessDetecting Dye-Contaminated Vegetables Using Low-Field NMR Relaxometry
Dyeing vegetables with harmful compounds has become an alarming public health issue over the past few years. Excessive consumption of these dyed vegetables can cause severe health hazards, including cancer. Copper sulfate, malachite green, and Sudan red are some of the non-food-grade dyes widely used on vegetables by untrusted entities in the food supply chain to make them look fresh and vibrant. In this study, the presence and quantity of dye-based adulteration in vegetables are determined by applying 1H-nuclear magnetic resonance (NMR) relaxometry. The proposed technique was validated by treating some vegetables in-house with different dyes and then soaking them in various solvents. The resulting solutions were collected and analyzed using NMR relaxometry. Specifically, the effective transverse relaxation time constant, T2,eff, of each solution was estimated using a Carr–Purcell–Meiboom–Gill (CPMG) pulse sequence. Finally, the estimated time constants (i.e., measured signatures) were compared with a library of existing T2,eff data to detect and quantify the presence of unwanted dyes. The latter consists of data-driven models of transverse decay times for various concentrations of each water-soluble dye. The time required to analyze each sample using the proposed approach is dye-dependent but typically no longer than a few minutes. The analysis results can be used to generate warning flags if the detected dye concentrations violate widely accepted standards for food dyes. The proposed low-cost detection approach can be used in various stages of a produce supply chain, including consumer household.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Consumer Electronics Magazine
- Vol. 10 (2) , 72-79
A Smart Mask for Active Defense Against Coronaviruses and Other Airborne Pathogens
Face masks provide effective, easyto-use, and low-cost protection against airborne pathogens or infectious agents, including SARS-CoV-2. Existing masks are all passive in nature, i.e., simply act as air filters for the nasal passage and/or mouth. This paper presents a new “active mask” paradigm, in which the wearable device is equipped with smart sensors and actuators to both detect the presence of airborne pathogens in real time and take appropriate action to mitigate the threat. The proposed approach is based on a closed-loop control system that senses airborne particles of different sizes near the mask and then makes intelligent decisions to reduce their concentrations. In the current implementation, an on-board controller determines ambient air quality via a commercial particulate matter (PM) sensor, and if necessary activates a piezoelectric actuator that generates a mist spray to load these particles, thus causing them to fall to the ground. The system communicates with the user via a smart phone application that provides various alerts, including the need to recharge and/or decontaminate the mask prior to reuse. The application also enables a user to override the on-board control system and manually control the mist generator if necessary. Experimental results from a functional prototype demonstrate significant reduction in airborne PM counts near the mask when the active protection system is enabled.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Consumer Electronics Magazine
- Vol. 10 (2) , 72-79
A Smart Mask for Active Defense Against Coronaviruses and Other Airborne Pathogens
Face masks provide effective, easyto-use, and low-cost protection against airborne pathogens or infectious agents, including SARS-CoV-2. Existing masks are all passive in nature, i.e., simply act as air filters for the nasal passage and/or mouth. This paper presents a new “active mask” paradigm, in which the wearable device is equipped with smart sensors and actuators to both detect the presence of airborne pathogens in real time and take appropriate action to mitigate the threat. The proposed approach is based on a closed-loop control system that senses airborne particles of different sizes near the mask and then makes intelligent decisions to reduce their concentrations. In the current implementation, an on-board controller determines ambient air quality via a commercial particulate matter (PM) sensor, and if necessary activates a piezoelectric actuator that generates a mist spray to load these particles, thus causing them to fall to the ground. The system communicates with the user via a smart phone application that provides various alerts, including the need to recharge and/or decontaminate the mask prior to reuse. The application also enables a user to override the on-board control system and manually control the mist generator if necessary. Experimental results from a functional prototype demonstrate significant reduction in airborne PM counts near the mask when the active protection system is enabled.
- 1 February 2020
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 311, 106660
Single-shot spatially-localized NQR using field-dependent relaxation rates
- 1 February 2020
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 311, 106660
Single-shot spatially-localized NQR using field-dependent relaxation rates
- Open Access
- 18 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 14396-14409
Robust Authentication of Consumables With Extrinsic Tags and Chemical Fingerprinting
Consumables - from food, to pharmaceuticals, and supplements - are becoming increasingly vulnerable to various modes of counterfeiting due to the growing complexity of their supply chain. Mislabeling, re-branding, and false advertising are prevalent in this sector. Existing physical authentication techniques fail to adequately verify integrity of these products and protect the end-users. In this paper, we aim at addressing this critical problem through development of a novel authentication solution. It builds on the chemical analysis properties of a powerful spectroscopy technique, namely, Nuclear Quadrupole Resonance (NQR), that is quantitative, non-invasive, low-cost, and amenable for miniaturization (to hand-held form factors). The method is sensitive to small variations in the solid-state chemical structure of a sample, which change the NQR signal properties. These attributes can be unique for various manufacturers, enabling their use as manufacturer-specific watermarks. However, NQR spectroscopy only works reliably (i.e., provides good sensitivity) on compounds that contain certain nuclear isotopes. We take advantage of the intrinsic properties of NQRsensitive isotopes to use them as extrinsic tags in NQR-insensitive products. The NQR spectra of these extrinsic tags act as unique watermarks that can be analyzed using machine learning methods to authenticate any consumable with high confidence. In particular, we use support vector machines (SVMs) to classify the measured spectra and confirm the identity of items under test. We have assessed this approach on a variety of consumables utilizing semi-custom equipment, and verified that it results in high (> 95%) classification accuracy. In order to prove the unclonability of such extrinsic tags, we have also performed a mathematical analysis that proves the randomness of the extrinsic tag and confirms its robustness to brute-force attacks.
- 18 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 14396-14409
Open AccessRobust Authentication of Consumables With Extrinsic Tags and Chemical Fingerprinting
Consumables - from food, to pharmaceuticals, and supplements - are becoming increasingly vulnerable to various modes of counterfeiting due to the growing complexity of their supply chain. Mislabeling, re-branding, and false advertising are prevalent in this sector. Existing physical authentication techniques fail to adequately verify integrity of these products and protect the end-users. In this paper, we aim at addressing this critical problem through development of a novel authentication solution. It builds on the chemical analysis properties of a powerful spectroscopy technique, namely, Nuclear Quadrupole Resonance (NQR), that is quantitative, non-invasive, low-cost, and amenable for miniaturization (to hand-held form factors). The method is sensitive to small variations in the solid-state chemical structure of a sample, which change the NQR signal properties. These attributes can be unique for various manufacturers, enabling their use as manufacturer-specific watermarks. However, NQR spectroscopy only works reliably (i.e., provides good sensitivity) on compounds that contain certain nuclear isotopes. We take advantage of the intrinsic properties of NQRsensitive isotopes to use them as extrinsic tags in NQR-insensitive products. The NQR spectra of these extrinsic tags act as unique watermarks that can be analyzed using machine learning methods to authenticate any consumable with high confidence. In particular, we use support vector machines (SVMs) to classify the measured spectra and confirm the identity of items under test. We have assessed this approach on a variety of consumables utilizing semi-custom equipment, and verified that it results in high (> 95%) classification accuracy. In order to prove the unclonability of such extrinsic tags, we have also performed a mathematical analysis that proves the randomness of the extrinsic tag and confirms its robustness to brute-force attacks.
- 10 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Consumer Electronics Magazine
- Vol. 8 (1) , 12-18
Eat, but Verify: Low-Cost Portable Devices for Food Safety Analysis
Illness caused by adulterated and counterfeit foods is a very common health issue for consumers. Food fraud also affects manufacturers by damaging their reputation, resulting in a decrease in market share and consumer trust. Thus, food safety has emerged as a critical issue for consumers and manufacturers alike. Fraudulent food products are often the result of opportunities taken by willful offenders who mislabel, falsify, and/or adulterate for economic gains. In some cases, the contents of a packaged food item may not match its label. In other cases, the labeling may be correct while the product itself is counterfeit. Thus, in today's market where most food items are industrially packaged prior to sale, it is important to prioritize the consumers' right to authentic and safe food products. The solution to this challenge is not to use expensive security measures that increase the final price, but to develop economical and portable food safety, quality assurance, and authentication devices for use at all stages of a food product life cycle-from production to consumption. Such devices would be a game-changer in the field of food safety.
- 10 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Consumer Electronics Magazine
- Vol. 8 (1) , 12-18
Eat, but Verify: Low-Cost Portable Devices for Food Safety Analysis
Illness caused by adulterated and counterfeit foods is a very common health issue for consumers. Food fraud also affects manufacturers by damaging their reputation, resulting in a decrease in market share and consumer trust. Thus, food safety has emerged as a critical issue for consumers and manufacturers alike. Fraudulent food products are often the result of opportunities taken by willful offenders who mislabel, falsify, and/or adulterate for economic gains. In some cases, the contents of a packaged food item may not match its label. In other cases, the labeling may be correct while the product itself is counterfeit. Thus, in today's market where most food items are industrially packaged prior to sale, it is important to prioritize the consumers' right to authentic and safe food products. The solution to this challenge is not to use expensive security measures that increase the final price, but to develop economical and portable food safety, quality assurance, and authentication devices for use at all stages of a food product life cycle-from production to consumption. Such devices would be a game-changer in the field of food safety.
- 24 July 2018
- Published by Oxford University Press (OUP) in International Journal of Food Science and Technology
- Vol. 53 (12) , 2796-2809
Authentication of dietary supplements through Nuclear Quadrupole Resonance (NQR) spectroscopy
Summary: As the industry grows, adulteration of many products by mislabelling, re‐branding and false advertising is becoming prevalent practice. Existing solutions for analysis often require extensive sample preparation or are limited in terms of detecting different types of integrity issues. We describe a novel authentication method based on Nuclear Quadrupole Resonance (NQR) spectroscopy which is quantitative, non‐invasive and non‐destructive. It is sensitive to small deviation in the solid‐state chemical structure of a product, which changes the NQR signal properties. These characteristics are unique for different manufacturers, resulting in manufacturer‐specific watermarks. We show that nominally identical dietary supplements from different manufacturers can be accurately classified based on features from NQR spectra. Specifically, we use a machine learning‐based classification called support vector machines (SVMs) to verify the authenticity of products under test. This approach has been evaluated on three products using semi‐custom hardware and shows promising results, with typical classification accuracy of over 95%.
- 24 July 2018
- Published by Oxford University Press (OUP) in International Journal of Food Science and Technology
- Vol. 53 (12) , 2796-2809
Authentication of dietary supplements through Nuclear Quadrupole Resonance (NQR) spectroscopy
Summary: As the industry grows, adulteration of many products by mislabelling, re‐branding and false advertising is becoming prevalent practice. Existing solutions for analysis often require extensive sample preparation or are limited in terms of detecting different types of integrity issues. We describe a novel authentication method based on Nuclear Quadrupole Resonance (NQR) spectroscopy which is quantitative, non‐invasive and non‐destructive. It is sensitive to small deviation in the solid‐state chemical structure of a product, which changes the NQR signal properties. These characteristics are unique for different manufacturers, resulting in manufacturer‐specific watermarks. We show that nominally identical dietary supplements from different manufacturers can be accurately classified based on features from NQR spectra. Specifically, we use a machine learning‐based classification called support vector machines (SVMs) to verify the authenticity of products under test. This approach has been evaluated on three products using semi‐custom hardware and shows promising results, with typical classification accuracy of over 95%.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Authentication and traceability of food products through the supply chain using NQR spectroscopy
Maintaining the security and integrity of our food supply chain has emerged as a critical need. In this paper, we describe a novel authentication approach that can significantly improve the security of the food supply chain. It relies on applying nuclear quadrupole resonance (NQR) spectroscopy to authenticate the contents of packaged food products. NQR is a non-invasive, non-destructive, and quantitative radio frequency (RF) spectroscopic technique. It is sensitive to subtle features of the solid-state chemical environment such that signal properties are influenced by the manufacturing process, thus generating a manufacturer-specific watermark or intrinsic tag for the product. Such tags enable us to uniquely characterize and authenticate products of identical composition but from different manufacturers based on their NQR signal parameters. These intrinsic tags can be used to verify the integrity of a product and trace it through the supply chain. We apply a support vector machine (SVM)-based classification approach that trains the SVM with measured NQR parameters and then authenticates food products by checking their test responses. Measurement on an example substance using semi-custom hardware shows promising results (95% classification accuracy) which can be further improved with improved instrumentation.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Authentication and traceability of food products through the supply chain using NQR spectroscopy
Maintaining the security and integrity of our food supply chain has emerged as a critical need. In this paper, we describe a novel authentication approach that can significantly improve the security of the food supply chain. It relies on applying nuclear quadrupole resonance (NQR) spectroscopy to authenticate the contents of packaged food products. NQR is a non-invasive, non-destructive, and quantitative radio frequency (RF) spectroscopic technique. It is sensitive to subtle features of the solid-state chemical environment such that signal properties are influenced by the manufacturing process, thus generating a manufacturer-specific watermark or intrinsic tag for the product. Such tags enable us to uniquely characterize and authenticate products of identical composition but from different manufacturers based on their NQR signal parameters. These intrinsic tags can be used to verify the integrity of a product and trace it through the supply chain. We apply a support vector machine (SVM)-based classification approach that trains the SVM with measured NQR parameters and then authenticates food products by checking their test responses. Measurement on an example substance using semi-custom hardware shows promising results (95% classification accuracy) which can be further improved with improved instrumentation.