Sang Hyun Cho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sang Hyun Cho has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
Sandun Jayarathna
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
12 shared publicationsNivedh Manohar
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030, USA
9 shared publicationsHem Moktan
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center , 1515 Holcombe Blvd., Houston, Texas 77030 , USA
7 shared publicationsSunil Krishnan
Vivian L. Smith Department of Neurosurgery The University of Texas Health Science Center Houston Texas USA
7 shared publicationsFoiez Ahmed
The University of Texas MD Anderson Cancer Center, Houston, TX, USA
6 shared publicationsFrancisco J. Reynoso
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
6 shared publications
Latest Publications
- Open Access
- 27 May 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Monte carlo study of detection limit for gold nanoparticles within small animal sized object during benchtop X-ray fluorescence computed tomography
This Monte Carlo (MC) study investigated theoretically achievable detection limits of gold nanoparticles (GNPs) present within a small-animal-sized phantom during benchtop x-ray fluorescence (XRF) computed tomography (XFCT) imaging based on the detection of gold K-shell XRF photons emitted from GNPs. The MC model was based on our experimental benchtop cone-beam XFCT system, reflecting an anticipated upgrade adopting a larger field-of-view pixelated cadmium-telluride detector that fully covers a 3 cm-diameter PMMA phantom including three 6 mm-diameter cylindrical holes filled with various concentrations of GNPs. It was validated by comparing the MC results with experimental data acquired under identical conditions using a 1.8 mm-Sn-filtered 125 kVp beam. The MC simulations were then extended to investigate GNP detection limits across a range of x-ray doses, GNP concentrations, and incident x-ray beam spectra. Assuming an ideal detector, the GNP detection limits of 104–140 ppm at 1.775 cGy and 69–88 ppm at 3.55 cGy were achievable with the 1.8 mm Sn-filtered 125 kVp beam. When hypothetical monochromatic beams with their energy above the gold K-edge were employed, the GNP detection limits were improved by up to three-folds at a given dose (e.g., 34–70 ppm at 1.775 cGy with the 85 keV beam).
- 27 May 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessMonte carlo study of detection limit for gold nanoparticles within small animal sized object during benchtop X-ray fluorescence computed tomography
This Monte Carlo (MC) study investigated theoretically achievable detection limits of gold nanoparticles (GNPs) present within a small-animal-sized phantom during benchtop x-ray fluorescence (XRF) computed tomography (XFCT) imaging based on the detection of gold K-shell XRF photons emitted from GNPs. The MC model was based on our experimental benchtop cone-beam XFCT system, reflecting an anticipated upgrade adopting a larger field-of-view pixelated cadmium-telluride detector that fully covers a 3 cm-diameter PMMA phantom including three 6 mm-diameter cylindrical holes filled with various concentrations of GNPs. It was validated by comparing the MC results with experimental data acquired under identical conditions using a 1.8 mm-Sn-filtered 125 kVp beam. The MC simulations were then extended to investigate GNP detection limits across a range of x-ray doses, GNP concentrations, and incident x-ray beam spectra. Assuming an ideal detector, the GNP detection limits of 104–140 ppm at 1.775 cGy and 69–88 ppm at 3.55 cGy were achievable with the 1.8 mm Sn-filtered 125 kVp beam. When hypothetical monochromatic beams with their energy above the gold K-edge were employed, the GNP detection limits were improved by up to three-folds at a given dose (e.g., 34–70 ppm at 1.775 cGy with the 85 keV beam).
- Open Access
- 4 June 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 19588
Deep learning based rapid X-ray fluorescence signal extraction and image reconstruction for preclinical benchtop X-ray fluorescence computed tomography applications
Recent research advances have resulted in an experimental benchtop X-ray fluorescence computed tomography (XFCT) system that likely meets the imaging dose/scan time constraints for benchtop XFCT imaging of live mice injected with gold nanoparticles (GNPs). For routine in vivo benchtop XFCT imaging, however, additional challenges, most notably the need for rapid/near-real-time handling of X-ray fluorescence (XRF) signal extraction and XFCT image reconstruction, must be successfully addressed. Here we propose a novel end-to-end deep learning (DL) framework that integrates a one-dimensional convolutional neural network (1D CNN) for rapid XRF signal extraction with a U-Net model for XFCT image reconstruction. We trained the models using a comprehensive dataset including experimentally-acquired and augmented XRF/scatter photon spectra from various GNP concentrations and imaging scenarios, including phantom and synthetic mouse models. The DL framework demonstrated exceptional performance in both tasks. The 1D CNN achieved a high coefficient-of-determination (R² > 0.9885) and a low mean-absolute-error (MAE < 0.6248) in XRF signal extraction. The U-Net model achieved an average structural-similarity-index-measure (SSIM) of 0.9791 and a peak signal-to-noise ratio (PSNR) of 39.11 in XFCT image reconstruction, closely matching ground truth images. Notably, the DL approach (vs. the conventional approach) reduced the total post-processing time per slice from approximately 6 min to just 1.25 s.
- 4 June 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 19588
Open AccessDeep learning based rapid X-ray fluorescence signal extraction and image reconstruction for preclinical benchtop X-ray fluorescence computed tomography applications
Recent research advances have resulted in an experimental benchtop X-ray fluorescence computed tomography (XFCT) system that likely meets the imaging dose/scan time constraints for benchtop XFCT imaging of live mice injected with gold nanoparticles (GNPs). For routine in vivo benchtop XFCT imaging, however, additional challenges, most notably the need for rapid/near-real-time handling of X-ray fluorescence (XRF) signal extraction and XFCT image reconstruction, must be successfully addressed. Here we propose a novel end-to-end deep learning (DL) framework that integrates a one-dimensional convolutional neural network (1D CNN) for rapid XRF signal extraction with a U-Net model for XFCT image reconstruction. We trained the models using a comprehensive dataset including experimentally-acquired and augmented XRF/scatter photon spectra from various GNP concentrations and imaging scenarios, including phantom and synthetic mouse models. The DL framework demonstrated exceptional performance in both tasks. The 1D CNN achieved a high coefficient-of-determination (R² > 0.9885) and a low mean-absolute-error (MAE < 0.6248) in XRF signal extraction. The U-Net model achieved an average structural-similarity-index-measure (SSIM) of 0.9791 and a peak signal-to-noise ratio (PSNR) of 39.11 in XFCT image reconstruction, closely matching ground truth images. Notably, the DL approach (vs. the conventional approach) reduced the total post-processing time per slice from approximately 6 min to just 1.25 s.
- 10 February 2025
- Published by Wiley in Medical Physics
- Vol. 52 (6) , 4605-4620
Monte Carlo study of gold nanoparticle‐mediated radiosensitization effects using nanoscale cell model combined with fractal‐based DNA model
Background: Gold nanoparticles (GNPs) are promising radiosensitizers in radiation therapy, yet the exact mechanisms behind their effectiveness remain not fully understood. Monte Carlo (MC) simulations have been used to study extra energy deposition and increased DNA damage by the secondary electrons from intracellularly present GNPs, which are believed to be the key physical mechanisms responsible for the radiosensitization effects observed in many radiobiological studies. However, discrepancies between experimental results and computational predictions persist. While often attributed to purely biological effects, such discrepancies, from a physical modeling point of view, can also be due to the use of MC models constructed with simplified cellular/DNA geometries and unrealistic GNP distributions. To address this challenge, higher‐resolution nanoscale models with realistic GNP distributions and detailed cellular/DNA structures are needed. In principle, computational results from such nanoscale models can be not only more accurate but also directly correlated with experimental results for biological outcome modeling. Purpose: The main purpose of this MC study was to investigate the potential increase in radiation‐induced DNA damage due to internalized GNPs by using a nanoscale cell model including realistic GNP distributions and detailed cellular/DNA structures. Methods: Two high‐resolution nanoscale cellular geometry models, featuring the nucleus filled with fractal‐patterned DNA fibers, were constructed from transmission electron microscopy (TEM) images of GNP‐laden human colorectal tumor cells. These models were used to simulate the initial yield of single‐ and double‐strand breaks (SSBs and DSBs) of DNA under orthovoltage (250 kVp) and megavoltage (6 MV) photon beam irradiation. In‐depth Geant4 MC simulations were conducted to assess radiation‐induced effects due to intracellular GNP presence and absence, focusing on the computation of SSBs/DSBs and their causative mechanisms – direct or indirect effects of ionizing radiation. Penelope and Geant4‐DNA for Gold (G4_DNA_Au) physics models were employed for GNPs, and the difference between those two physics models were also evaluated. Results: The simulation results revealed a notable enhancement in the nucleus dose and DNA damage due to intracellular GNP presence, with maximum dose enhancements observed at 4.24% and 4.34% for 250 kVp, and 3.04% and 3.22% for 6 MV irradiation using the Penelope and G4_DNA_Au physics models, respectively. Crucially, this study found that indirect yields of both SSB and DSB were significantly higher than their direct counterparts, emphasizing the dominance of indirect DNA damage mechanisms. SSB enhancements were recorded between 2.36% and 3.46%, while DSB enhancements were more significant, ranging from 7.36% to 10.33%, across various scenarios and photon energies under the G4_DNA_Au physics model. The 250 kVp beam showed more SSB enhancement, whereas the 6 MV beam yielded more DSB enhancement. Conclusion: With a realistic fractal‐based chromatin fiber arrangement of DNA within the nucleus, the currently developed TEM‐based cellular geometry model enabled the unprecedented investigation of radiation‐induced DNA damage in a single GNP‐laden cell using track structure Geant4 MC simulations. The modeling approaches and findings from this study significantly enhance our ability and knowledge to conduct computational investigations of GNP‐mediated radiosensitization, possibly leading to the development of a predictive biological outcome model with minimal empiricism.
- 10 February 2025
- Published by Wiley in Medical Physics
- Vol. 52 (6) , 4605-4620
Monte Carlo study of gold nanoparticle‐mediated radiosensitization effects using nanoscale cell model combined with fractal‐based DNA model
Background: Gold nanoparticles (GNPs) are promising radiosensitizers in radiation therapy, yet the exact mechanisms behind their effectiveness remain not fully understood. Monte Carlo (MC) simulations have been used to study extra energy deposition and increased DNA damage by the secondary electrons from intracellularly present GNPs, which are believed to be the key physical mechanisms responsible for the radiosensitization effects observed in many radiobiological studies. However, discrepancies between experimental results and computational predictions persist. While often attributed to purely biological effects, such discrepancies, from a physical modeling point of view, can also be due to the use of MC models constructed with simplified cellular/DNA geometries and unrealistic GNP distributions. To address this challenge, higher‐resolution nanoscale models with realistic GNP distributions and detailed cellular/DNA structures are needed. In principle, computational results from such nanoscale models can be not only more accurate but also directly correlated with experimental results for biological outcome modeling. Purpose: The main purpose of this MC study was to investigate the potential increase in radiation‐induced DNA damage due to internalized GNPs by using a nanoscale cell model including realistic GNP distributions and detailed cellular/DNA structures. Methods: Two high‐resolution nanoscale cellular geometry models, featuring the nucleus filled with fractal‐patterned DNA fibers, were constructed from transmission electron microscopy (TEM) images of GNP‐laden human colorectal tumor cells. These models were used to simulate the initial yield of single‐ and double‐strand breaks (SSBs and DSBs) of DNA under orthovoltage (250 kVp) and megavoltage (6 MV) photon beam irradiation. In‐depth Geant4 MC simulations were conducted to assess radiation‐induced effects due to intracellular GNP presence and absence, focusing on the computation of SSBs/DSBs and their causative mechanisms – direct or indirect effects of ionizing radiation. Penelope and Geant4‐DNA for Gold (G4_DNA_Au) physics models were employed for GNPs, and the difference between those two physics models were also evaluated. Results: The simulation results revealed a notable enhancement in the nucleus dose and DNA damage due to intracellular GNP presence, with maximum dose enhancements observed at 4.24% and 4.34% for 250 kVp, and 3.04% and 3.22% for 6 MV irradiation using the Penelope and G4_DNA_Au physics models, respectively. Crucially, this study found that indirect yields of both SSB and DSB were significantly higher than their direct counterparts, emphasizing the dominance of indirect DNA damage mechanisms. SSB enhancements were recorded between 2.36% and 3.46%, while DSB enhancements were more significant, ranging from 7.36% to 10.33%, across various scenarios and photon energies under the G4_DNA_Au physics model. The 250 kVp beam showed more SSB enhancement, whereas the 6 MV beam yielded more DSB enhancement. Conclusion: With a realistic fractal‐based chromatin fiber arrangement of DNA within the nucleus, the currently developed TEM‐based cellular geometry model enabled the unprecedented investigation of radiation‐induced DNA damage in a single GNP‐laden cell using track structure Geant4 MC simulations. The modeling approaches and findings from this study significantly enhance our ability and knowledge to conduct computational investigations of GNP‐mediated radiosensitization, possibly leading to the development of a predictive biological outcome model with minimal empiricism.
- 31 December 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1072
Monte Carlo modeling of an experimental benchtop L-shell x-ray fluorescence imaging/CT system adopting two silicon drift detectors
- 31 December 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1072
Monte Carlo modeling of an experimental benchtop L-shell x-ray fluorescence imaging/CT system adopting two silicon drift detectors
- 4 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (4) , 1474-1487
Deep Learning-Based TEM Image Analysis for Fully Automated Detection of Gold Nanoparticles Internalized Within Tumor Cell
Transmission electron microscopy (TEM) imaging can be used for detection/localization of gold nanoparticles (GNPs) within tumor cells. However, quantitative analysis of GNP-containing cellular TEM images typically relies on conventional/thresholding-based methods, which are manual, time-consuming, and prone to human errors. In this study, therefore, deep learning (DL)–based methods were developed for fully automated detection of GNPs from cellular TEM images. Several models of “you only look once (YOLO)” v5 were implemented, with a few adjustments to enhance the model’s performance by applying the transfer learning approach, adjusting the size of the input image, and choosing the best optimization algorithm. Seventy-eight original (12,040 augmented) TEM images of GNP-laden tumor cells were used for model implementation and validation. A maximum F1 score (harmonic mean of the precision and recall) of 0.982 was achieved by the best-trained models, while mean average precision was 0.989 and 0.843 at 0.50 and 0.50–0.95 intersection over union threshold, respectively. These results suggested the developed DL-based approach was capable of precisely estimating the number/position of internalized GNPs from cellular TEM images. A novel DL-based TEM image analysis tool from this study will benefit research/development efforts on GNP-based cancer therapeutics, for example, by enabling the modeling of GNP-laden tumor cells using nanometer-resolution TEM images.
- 4 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (4) , 1474-1487
Deep Learning-Based TEM Image Analysis for Fully Automated Detection of Gold Nanoparticles Internalized Within Tumor Cell
Transmission electron microscopy (TEM) imaging can be used for detection/localization of gold nanoparticles (GNPs) within tumor cells. However, quantitative analysis of GNP-containing cellular TEM images typically relies on conventional/thresholding-based methods, which are manual, time-consuming, and prone to human errors. In this study, therefore, deep learning (DL)–based methods were developed for fully automated detection of GNPs from cellular TEM images. Several models of “you only look once (YOLO)” v5 were implemented, with a few adjustments to enhance the model’s performance by applying the transfer learning approach, adjusting the size of the input image, and choosing the best optimization algorithm. Seventy-eight original (12,040 augmented) TEM images of GNP-laden tumor cells were used for model implementation and validation. A maximum F1 score (harmonic mean of the precision and recall) of 0.982 was achieved by the best-trained models, while mean average precision was 0.989 and 0.843 at 0.50 and 0.50–0.95 intersection over union threshold, respectively. These results suggested the developed DL-based approach was capable of precisely estimating the number/position of internalized GNPs from cellular TEM images. A novel DL-based TEM image analysis tool from this study will benefit research/development efforts on GNP-based cancer therapeutics, for example, by enabling the modeling of GNP-laden tumor cells using nanometer-resolution TEM images.
- Open Access
- 28 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 105074-105083
Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
In this work, we integrated a commercially-available fully-spectroscopic pixelated cadmium telluride (CdTe) detector system as a two-dimensional (2D) array detector into our existing benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system. After integrating this detector, known as High-Energy X-ray Imaging Technology (HEXITEC), we performed quantitative imaging of gold nanoparticle (GNP) distribution in a small animal-sized phantom using our benchtop XFCT system. Owing to the upgraded detector component within our benchtop XFCT system, we were able to conduct this phantom imaging in an unprecedented manner by volumetric XFCT scans followed by XFCT image reconstruction in 3D. The current results showed that adoption of HEXITEC, in conjunction with a custom-made parallel-hole collimator, drastically reduced the XFCT scan time/dose. Compared with the previous work performed with our original benchtop XFCT system adopting a single crystal CdTe detector, the currently observed reduction was up to a factor of 5, while achieving comparable GNP detection limit under similar experimental conditions. Overall, we demonstrated, for the first time to the best our knowledge, the feasibility of benchtop XFCT imaging of small animal-sized objects containing biologically relevant GNP concentrations (on the order of 0.1 mg Au/cm3 or 100 parts-per-million/ppm), with the scan time (on the order of 1 minute)/ x-ray dose (on the order of 10 cGy) that are likely meeting the minimum requirements for routine preclinical imaging applications.
- 28 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 105074-105083
Open AccessUse of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
In this work, we integrated a commercially-available fully-spectroscopic pixelated cadmium telluride (CdTe) detector system as a two-dimensional (2D) array detector into our existing benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system. After integrating this detector, known as High-Energy X-ray Imaging Technology (HEXITEC), we performed quantitative imaging of gold nanoparticle (GNP) distribution in a small animal-sized phantom using our benchtop XFCT system. Owing to the upgraded detector component within our benchtop XFCT system, we were able to conduct this phantom imaging in an unprecedented manner by volumetric XFCT scans followed by XFCT image reconstruction in 3D. The current results showed that adoption of HEXITEC, in conjunction with a custom-made parallel-hole collimator, drastically reduced the XFCT scan time/dose. Compared with the previous work performed with our original benchtop XFCT system adopting a single crystal CdTe detector, the currently observed reduction was up to a factor of 5, while achieving comparable GNP detection limit under similar experimental conditions. Overall, we demonstrated, for the first time to the best our knowledge, the feasibility of benchtop XFCT imaging of small animal-sized objects containing biologically relevant GNP concentrations (on the order of 0.1 mg Au/cm3 or 100 parts-per-million/ppm), with the scan time (on the order of 1 minute)/ x-ray dose (on the order of 10 cGy) that are likely meeting the minimum requirements for routine preclinical imaging applications.
- 13 December 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1025
Sensitivity enhancement of an experimental benchtop X-ray fluorescence imaging system by deploying a single crystal cadmium telluride detector system optimized for high flux X-ray operations
- 13 December 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1025
Sensitivity enhancement of an experimental benchtop X-ray fluorescence imaging system by deploying a single crystal cadmium telluride detector system optimized for high flux X-ray operations
- 7 December 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (1) , 017002
Bias-voltage dependent operational characteristics of a fully spectroscopic pixelated cadmium telluride detector system within an experimental benchtop x-ray fluorescence imaging setup
Commercially available fully spectroscopic pixelated cadmium telluride (CdTe) detector systems have been adopted lately for benchtop x-ray fluorescence (XRF) imaging/computed tomography (XFCT) of objects containing metal nanoprobes such as gold nanoparticles (GNPs). To date, however, some important characteristics of such detector systems under typical operating conditions of benchtop XRF/XFCT imaging systems are not well known. One important but poorly studied characteristic is the effect of detector bias-voltage on photon counting efficiency, energy resolution, and the resulting material detection limit. In this work, therefore, we investigated these characteristics for a commercial pixelated detector system adopting a 1-mm-thick CdTe sensor (0.25-mm pixel-pitch), known as HEXITEC, incorporated into an experimental benchtop cone-beam XFCT system with parallel-hole detector collimation. The detector system, operated at different bias-voltages, was used to acquire the gold XRF/Compton spectra from 1.0 wt% GNP-loaded phantom irradiated with 125 kVp x-rays filtered by 1.8-mm Tin. At each bias-voltage, the gold XRF signal, and the full-width-at-half-maximum at gold K α 2 XRF peak (∼67 keV) provided photon counting efficiency and energy resolution, respectively. Under the current experimental conditions, the detector photon counting efficiency and energy resolution improved with increasing bias-voltage by ∼41 and ∼29% at −300V; ∼54 and ∼35% at −500V, respectively, when compared to those at −100V. Consequently, the GNP detection limit improved by ∼26% at −300V and ∼30% at −500V. Furthermore, the homogeneity of per-pixel energy resolution within the collimated detector area improved by ∼34% at −300V and ∼54% at −500V. These results suggested the gradual improvements in the detector performance with increasing bias-voltage up to −500V. However, at and beyond −550V, there were no discernible improvements in photon counting efficiency and energy resolution. Thus, the bias-voltage range of −500 to −550V was found optimal under the current experimental conditions that are considered typical of benchtop XRF/XFCT imaging tasks.
- 7 December 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (1) , 017002
Bias-voltage dependent operational characteristics of a fully spectroscopic pixelated cadmium telluride detector system within an experimental benchtop x-ray fluorescence imaging setup
Commercially available fully spectroscopic pixelated cadmium telluride (CdTe) detector systems have been adopted lately for benchtop x-ray fluorescence (XRF) imaging/computed tomography (XFCT) of objects containing metal nanoprobes such as gold nanoparticles (GNPs). To date, however, some important characteristics of such detector systems under typical operating conditions of benchtop XRF/XFCT imaging systems are not well known. One important but poorly studied characteristic is the effect of detector bias-voltage on photon counting efficiency, energy resolution, and the resulting material detection limit. In this work, therefore, we investigated these characteristics for a commercial pixelated detector system adopting a 1-mm-thick CdTe sensor (0.25-mm pixel-pitch), known as HEXITEC, incorporated into an experimental benchtop cone-beam XFCT system with parallel-hole detector collimation. The detector system, operated at different bias-voltages, was used to acquire the gold XRF/Compton spectra from 1.0 wt% GNP-loaded phantom irradiated with 125 kVp x-rays filtered by 1.8-mm Tin. At each bias-voltage, the gold XRF signal, and the full-width-at-half-maximum at gold K α 2 XRF peak (∼67 keV) provided photon counting efficiency and energy resolution, respectively. Under the current experimental conditions, the detector photon counting efficiency and energy resolution improved with increasing bias-voltage by ∼41 and ∼29% at −300V; ∼54 and ∼35% at −500V, respectively, when compared to those at −100V. Consequently, the GNP detection limit improved by ∼26% at −300V and ∼30% at −500V. Furthermore, the homogeneity of per-pixel energy resolution within the collimated detector area improved by ∼34% at −300V and ∼54% at −500V. These results suggested the gradual improvements in the detector performance with increasing bias-voltage up to −500V. However, at and beyond −550V, there were no discernible improvements in photon counting efficiency and energy resolution. Thus, the bias-voltage range of −500 to −550V was found optimal under the current experimental conditions that are considered typical of benchtop XRF/XFCT imaging tasks.
- Open Access
- 29 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 49912-49919
Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging
Pixelated semi-conductor detectors providing high energy resolution enable parallel acquisition of x-ray fluorescence (XRF) signals, potentially leading to performance enhancement of benchtop XRF imaging or computed tomography (XFCT) systems utilizing ordinary polychromatic x-ray sources. However, little is currently known about the characteristics of such detectors under typical operating conditions of benchtop XRF imaging/XFCT. In this work, a commercially available pixelated cadmium telluride (CdTe) detector system, HEXITEC (High Energy X-ray Imaging Technology), was characterized to address this issue. Specifically, HEXITEC was deployed into our benchtop cone-beam XFCT system, and used to detect gold$\text{K}\alpha $ XRF photons from gold nanoparticle (GNP)–loaded phantoms. To facilitate the detection of XRF photons, various parallel-hole stainless steel collimators were fabricated and coupled with HEXITEC. A pixel-by-pixel spectrum merging algorithm was introduced to obtain well-defined XRF + scatter spectra with parallel-hole collimators. The effect of charge sharing addition (CSA) and discrimination (CSD) algorithms was also investigated for pixel-level CS correction. Finally, the detector energy resolution, in terms of the full-width at half-maximum (FWHM) values at two gold$\text{K}\alpha $ XRF peaks (~68 keV), was also determined. Under the current experimental conditions, CSD provided the best energy resolution of HEXITEC (~1.05 keV FWHM), compared with CSA and no CS correction. This FWHM value was larger (by up to ~0.35 keV) than those reported previously for HEXITEC (at ~60 keV Am-241 peak) and single-crystal CdTe detectors (at two gold$\text{K}\alpha $ XRF peaks). This investigation highlighted characteristics of HEXITEC as well as the necessity for application-specific detector characterization.- 29 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 49912-49919
Open AccessCharacterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging
Pixelated semi-conductor detectors providing high energy resolution enable parallel acquisition of x-ray fluorescence (XRF) signals, potentially leading to performance enhancement of benchtop XRF imaging or computed tomography (XFCT) systems utilizing ordinary polychromatic x-ray sources. However, little is currently known about the characteristics of such detectors under typical operating conditions of benchtop XRF imaging/XFCT. In this work, a commercially available pixelated cadmium telluride (CdTe) detector system, HEXITEC (High Energy X-ray Imaging Technology), was characterized to address this issue. Specifically, HEXITEC was deployed into our benchtop cone-beam XFCT system, and used to detect gold$\text{K}\alpha $ XRF photons from gold nanoparticle (GNP)–loaded phantoms. To facilitate the detection of XRF photons, various parallel-hole stainless steel collimators were fabricated and coupled with HEXITEC. A pixel-by-pixel spectrum merging algorithm was introduced to obtain well-defined XRF + scatter spectra with parallel-hole collimators. The effect of charge sharing addition (CSA) and discrimination (CSD) algorithms was also investigated for pixel-level CS correction. Finally, the detector energy resolution, in terms of the full-width at half-maximum (FWHM) values at two gold$\text{K}\alpha $ XRF peaks (~68 keV), was also determined. Under the current experimental conditions, CSD provided the best energy resolution of HEXITEC (~1.05 keV FWHM), compared with CSA and no CS correction. This FWHM value was larger (by up to ~0.35 keV) than those reported previously for HEXITEC (at ~60 keV Am-241 peak) and single-crystal CdTe detectors (at two gold$\text{K}\alpha $ XRF peaks). This investigation highlighted characteristics of HEXITEC as well as the necessity for application-specific detector characterization. - 31 August 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (17) , 175010
Monte Carlo study of x-ray detection configurations for benchtop x-ray fluorescence computed tomography of gold nanoparticle-loaded objects
Over the last decade, the performance of benchtop x-ray fluorescence computed tomography (XFCT) systems has been significantly enhanced through hardware and software optimizations. Recent studies have indicated the need of energy-resolving pixelated/array detectors in the x-ray detection component to further improve the sensitivity and image resolution of benchtop XFCT systems while meeting the realistic constraints of dose and scan time. Thus, it is of immediate interest in the research community to conduct the following investigations: (a) delineation of strengths/weaknesses of detection configurations that incorporate pixelated/array detectors in combination with two most frequently used (parallel-hole and pinhole) collimators; (b) one-to-one comparison of their performance under identical imaging conditions of benchtop XFCT. In this study, we developed a Geant4-based Monte Carlo model to investigate the effects of the aforementioned detection configurations on the sensitivity and image resolution of a benchtop XFCT system. Using this model, we simulated the detection of x-ray fluorescence and scattered photons from gold nanoparticle-containing phantoms using energy-resolving pixelated detectors coupled with parallel-hole and pinhole collimators. Simulation results demonstrated that the detector consisting of large pixels (1 mm × 1 mm) combined with a parallel-hole collimator had better sensitivity (i.e. lower detection limit) than the detector made of smaller pixels (0.25 mm × 0.25 mm) coupled with a pinhole collimator. In comparison, although slightly less sensitive, the latter detector configuration achieved better image resolution than did the former. Thus, a detection configuration consisting of a pixelated detector with submillimeter pixels and a pinhole collimator is preferable when image resolution is critical for benchtop XFCT applications. On the other hand, the detector with larger pixels coupled with a parallel-hole collimator is better suited for benchtop XFCT applications in which higher sensitivity and shorter scan time are essential.
- 31 August 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (17) , 175010
Monte Carlo study of x-ray detection configurations for benchtop x-ray fluorescence computed tomography of gold nanoparticle-loaded objects
Over the last decade, the performance of benchtop x-ray fluorescence computed tomography (XFCT) systems has been significantly enhanced through hardware and software optimizations. Recent studies have indicated the need of energy-resolving pixelated/array detectors in the x-ray detection component to further improve the sensitivity and image resolution of benchtop XFCT systems while meeting the realistic constraints of dose and scan time. Thus, it is of immediate interest in the research community to conduct the following investigations: (a) delineation of strengths/weaknesses of detection configurations that incorporate pixelated/array detectors in combination with two most frequently used (parallel-hole and pinhole) collimators; (b) one-to-one comparison of their performance under identical imaging conditions of benchtop XFCT. In this study, we developed a Geant4-based Monte Carlo model to investigate the effects of the aforementioned detection configurations on the sensitivity and image resolution of a benchtop XFCT system. Using this model, we simulated the detection of x-ray fluorescence and scattered photons from gold nanoparticle-containing phantoms using energy-resolving pixelated detectors coupled with parallel-hole and pinhole collimators. Simulation results demonstrated that the detector consisting of large pixels (1 mm × 1 mm) combined with a parallel-hole collimator had better sensitivity (i.e. lower detection limit) than the detector made of smaller pixels (0.25 mm × 0.25 mm) coupled with a pinhole collimator. In comparison, although slightly less sensitive, the latter detector configuration achieved better image resolution than did the former. Thus, a detection configuration consisting of a pixelated detector with submillimeter pixels and a pinhole collimator is preferable when image resolution is critical for benchtop XFCT applications. On the other hand, the detector with larger pixels coupled with a parallel-hole collimator is better suited for benchtop XFCT applications in which higher sensitivity and shorter scan time are essential.