Majid Tayarani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Majid Tayarani has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Adib Abrishamifar
School of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran
5 shared publications - Ali Abdolali
Department of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran
5 shared publications - Ahmad Ghanaatian
School of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran
2 shared publications - Farhad Abbasnezhad
School of Electrical Engineering Iran University of Science and Technology Tehran Iran
2 shared publications Hamid Rajabalipanah
Applied Electromagnetic Laboratory School of Electrical Engineering Iran University of Science and Technology Tehran 13114‐16846 Iran
2 shared publicationsKamran Salehian
Iran University of Science and Technology,School of Electrical Engineering, Tehran, Iran
2 shared publications
Latest Publications
- Open Access
- 3 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Design of a microwave sensor for non-invasive monitoring of blood glucose level with high sensitivity using electromagnetic properties
This paper introduces a novel, portable microwave sensor for rapid, non-invasive blood glucose monitoring. The design features an octagonal array of complementary split ring resonators (CSRRs) on a dielectric substrate, operating safely in the industrial, scientific, and medical (ISM) frequency band. Its key innovation, an engineered 180∘ phase difference between adjacent unit cells, generates a highly concentrated electromagnetic (EM) field at the sample interface. This focused interaction significantly enhances measurement sensitivity and overall detection capability. The sensor accurately detects glucose concentrations across the 50-500 mg/dL clinical range, demonstrating a remarkable sensitivity of 2.3 MHz/(mg/dL) in laboratory settings and 1.78 MHz/(mg/dL) in realistic scenarios, surpassing existing microwave sensors. This superior performance is attributed to the CSRR architecture, which maximizes the sample's EM field interaction, enabling the precise quantification of subtle dielectric changes corresponding to varying glucose levels. Laboratory verification using a vector network analyzer (VNA) confirmed significant frequency shifts with glucose samples from 80 to 340 mg/dL. Beyond its high sensitivity, the sensor's compact size, simple fabrication, affordability, and non-ionizing operation establish it as a promising candidate for developing practical, real-time, non-invasive glucose monitoring systems to advance diabetes management.
- 3 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessDesign of a microwave sensor for non-invasive monitoring of blood glucose level with high sensitivity using electromagnetic properties
This paper introduces a novel, portable microwave sensor for rapid, non-invasive blood glucose monitoring. The design features an octagonal array of complementary split ring resonators (CSRRs) on a dielectric substrate, operating safely in the industrial, scientific, and medical (ISM) frequency band. Its key innovation, an engineered 180∘ phase difference between adjacent unit cells, generates a highly concentrated electromagnetic (EM) field at the sample interface. This focused interaction significantly enhances measurement sensitivity and overall detection capability. The sensor accurately detects glucose concentrations across the 50-500 mg/dL clinical range, demonstrating a remarkable sensitivity of 2.3 MHz/(mg/dL) in laboratory settings and 1.78 MHz/(mg/dL) in realistic scenarios, surpassing existing microwave sensors. This superior performance is attributed to the CSRR architecture, which maximizes the sample's EM field interaction, enabling the precise quantification of subtle dielectric changes corresponding to varying glucose levels. Laboratory verification using a vector network analyzer (VNA) confirmed significant frequency shifts with glucose samples from 80 to 340 mg/dL. Beyond its high sensitivity, the sensor's compact size, simple fabrication, affordability, and non-ionizing operation establish it as a promising candidate for developing practical, real-time, non-invasive glucose monitoring systems to advance diabetes management.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- p. 1
A Compact Wideband 3-Bit Microstrip Phase Shifter Using Resonator-Loaded Switched-Line Cells
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- p. 1
Open AccessA Compact Wideband 3-Bit Microstrip Phase Shifter Using Resonator-Loaded Switched-Line Cells
- Open Access
- 25 November 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
A novel SIGGW dual post band-pass filter for 5G millimeter-wave band applications with a transmission zero
Integration of planar circuits been considered a credible technique for low-cost mass production of microwave and millimeter-wave circuits and systems. For the first time, in this research a dual-post band-pass filter is designed and simulated in a three-layer substrate integrated gap groove waveguide (SIGGW) for 5G millimeter-wave frequency band applications. The filter includes 12 posts ( $$6 \times 2$$ ). Also, the structure facilitates to use resonant posts and so we can design the posts to add a transmission zero in lower rejection band. The design theory algorithm and its limitations are investigated based on the circuit model of filter. The results shows that FBW of 5% and a lower band transmission zero for the proposed 12 posts filter. Also, the results are verified by simulation using CST. According to the results, the proposed filter is a good option for Ka-band applications and can be used as the building block for suppressing the LO leakage that is commonly used for up-converting the 5G signal to Ka band.- 25 November 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Open AccessA novel SIGGW dual post band-pass filter for 5G millimeter-wave band applications with a transmission zero
Integration of planar circuits been considered a credible technique for low-cost mass production of microwave and millimeter-wave circuits and systems. For the first time, in this research a dual-post band-pass filter is designed and simulated in a three-layer substrate integrated gap groove waveguide (SIGGW) for 5G millimeter-wave frequency band applications. The filter includes 12 posts ( $$6 \times 2$$ ). Also, the structure facilitates to use resonant posts and so we can design the posts to add a transmission zero in lower rejection band. The design theory algorithm and its limitations are investigated based on the circuit model of filter. The results shows that FBW of 5% and a lower band transmission zero for the proposed 12 posts filter. Also, the results are verified by simulation using CST. According to the results, the proposed filter is a good option for Ka-band applications and can be used as the building block for suppressing the LO leakage that is commonly used for up-converting the 5G signal to Ka band. - Open Access
- 25 July 2023
- Published by Springer Nature in Research Square
A Novel SIGGW Dual Post Band-Pass Filter for 5G Millimeter-Wave Band Applications with a Transmission Zero
Integration of planar circuits been considered a credible technique for low-cost mass production of microwave and millimeter-wave circuits and systems. For the first time, in this research a dual-post band-pass filter is designed and simulated in a three-layer substrate integrated gap groove waveguide (SIGGW) for 5G millimeter-wave frequency band applications. The filter includes 12 posts (6 × 2). Also, the structure facilitates to use resonant posts and so we can design the posts to add a transmission zero in lower rejection band. The design theory algorithm and its limitations are investigated based on the circuit model of filter. The results shows that FBW of 5% and a lower band transmission zero for the proposed 12 posts filter. Also, the results are verified by simulation using CST. According to the results, the proposed filter is a good option for Ka-band applications and can be used as the building block for suppressing the LO leakage that is commonly used for up-converting the 5G signal to Ka band.
- 25 July 2023
- Published by Springer Nature in Research Square
Open AccessA Novel SIGGW Dual Post Band-Pass Filter for 5G Millimeter-Wave Band Applications with a Transmission Zero
Integration of planar circuits been considered a credible technique for low-cost mass production of microwave and millimeter-wave circuits and systems. For the first time, in this research a dual-post band-pass filter is designed and simulated in a three-layer substrate integrated gap groove waveguide (SIGGW) for 5G millimeter-wave frequency band applications. The filter includes 12 posts (6 × 2). Also, the structure facilitates to use resonant posts and so we can design the posts to add a transmission zero in lower rejection band. The design theory algorithm and its limitations are investigated based on the circuit model of filter. The results shows that FBW of 5% and a lower band transmission zero for the proposed 12 posts filter. Also, the results are verified by simulation using CST. According to the results, the proposed filter is a good option for Ka-band applications and can be used as the building block for suppressing the LO leakage that is commonly used for up-converting the 5G signal to Ka band.
- 6 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 71 (5) , 2055-2068
Reconstruction of Material Inhomogeneity Profile Using Partially Filled Rectangular Waveguide Measurements
This article presents a novel technique to reconstruct the inhomogeneity profiles of the material using partially filled rectangular waveguide (RWG) measurements. Variation in the sample width is developed to obtain the required independent scattering parameters for accurately reconstructing the inhomogeneity profiles. The electromagnetic parameters of the inhomogeneous sample are obtained, minimizing the difference between the measured and the theoretically calculated scattering parameters. For the first time in this article, the scattering parameters of the inhomogeneous material partially loaded in the RWG are theoretically calculated using the hybrid of mode matching and Taylor’s series expansion. A prototype of the measurement system is fabricated for experimental verification. Through comprehensive examples, experimental verifications are performed for the three types of inhomogeneous materials. The validity and accuracy of the proposed method are verified by comparing the results obtained by the RWG methods. The suggested technique is less expensive and more straightforward than the previously developed RWG method, which uses multiple waveguides and requires a single-time calibration.
- 6 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 71 (5) , 2055-2068
Reconstruction of Material Inhomogeneity Profile Using Partially Filled Rectangular Waveguide Measurements
This article presents a novel technique to reconstruct the inhomogeneity profiles of the material using partially filled rectangular waveguide (RWG) measurements. Variation in the sample width is developed to obtain the required independent scattering parameters for accurately reconstructing the inhomogeneity profiles. The electromagnetic parameters of the inhomogeneous sample are obtained, minimizing the difference between the measured and the theoretically calculated scattering parameters. For the first time in this article, the scattering parameters of the inhomogeneous material partially loaded in the RWG are theoretically calculated using the hybrid of mode matching and Taylor’s series expansion. A prototype of the measurement system is fabricated for experimental verification. Through comprehensive examples, experimental verifications are performed for the three types of inhomogeneous materials. The validity and accuracy of the proposed method are verified by comparing the results obtained by the RWG methods. The suggested technique is less expensive and more straightforward than the previously developed RWG method, which uses multiple waveguides and requires a single-time calibration.
- 22 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-15
Rectangular Waveguide Characterization of Biaxial Material Using TM11 Mode
A novel measurement technique is presented to determine the electromagnetic parameters of a biaxial material loaded in the rectangular waveguide. For the first time, in this paper, the TM11 waveguide mode is used as an incident filed for characterization. The electromagnetic parameters of the biaxial sample are obtained, minimizing the difference between the measured and the theoretically calculated scattering parameters. For this purpose, we theoretically calculate the reflection and transmission coefficients. A prototype of the measurement system is fabricated to validate the proposed approach. Subsequently, the proposed technique is used to experimentally characterize two types of biaxial materials. The validity and accuracy of the proposed method are verified by comparing the experimental results with those obtained by the conventional rectangular waveguide method. The suggested technique eliminates the problem of preparing multiple samples and rotating them in the traditional waveguide method.
- 22 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-15
Rectangular Waveguide Characterization of Biaxial Material Using TM11 Mode
A novel measurement technique is presented to determine the electromagnetic parameters of a biaxial material loaded in the rectangular waveguide. For the first time, in this paper, the TM11 waveguide mode is used as an incident filed for characterization. The electromagnetic parameters of the biaxial sample are obtained, minimizing the difference between the measured and the theoretically calculated scattering parameters. For this purpose, we theoretically calculate the reflection and transmission coefficients. A prototype of the measurement system is fabricated to validate the proposed approach. Subsequently, the proposed technique is used to experimentally characterize two types of biaxial materials. The validity and accuracy of the proposed method are verified by comparing the experimental results with those obtained by the conventional rectangular waveguide method. The suggested technique eliminates the problem of preparing multiple samples and rotating them in the traditional waveguide method.
- 11 June 2022
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 64 (10) , 1732-1739
A highly linearized second harmonic injected GaN power amplifier
This article presents an active second harmonic injection technique for linearizing power amplifiers (PAs). In this method, a second harmonic signal with adjustable amplitude and phase, which is generated by a differential pair network, is injected into the input of a PA in a forward path. The tunable input and output matching circuits of the proposed second harmonic generator provide linearization capability in a wide frequency band. To validate the concept, the proposed second harmonic injection technique was implemented to linearize a GaN PA working around 1.5 GHz. It was shown that applying the proposed linearization method increases the output 1‐dB compression point from 33.5 dBm to 39.5 dBm (about 2 dB lower than saturation power) under the CW signal. Furthermore, the backed‐off efficiency at a higher adjacent channel power ratio was improved, and improvement of 16 dB at 200 MHz frequency bandwidth was achieved for an 8 MS/s 64‐quadratic‐amplitude modulation signal.
- 11 June 2022
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 64 (10) , 1732-1739
A highly linearized second harmonic injected GaN power amplifier
This article presents an active second harmonic injection technique for linearizing power amplifiers (PAs). In this method, a second harmonic signal with adjustable amplitude and phase, which is generated by a differential pair network, is injected into the input of a PA in a forward path. The tunable input and output matching circuits of the proposed second harmonic generator provide linearization capability in a wide frequency band. To validate the concept, the proposed second harmonic injection technique was implemented to linearize a GaN PA working around 1.5 GHz. It was shown that applying the proposed linearization method increases the output 1‐dB compression point from 33.5 dBm to 39.5 dBm (about 2 dB lower than saturation power) under the CW signal. Furthermore, the backed‐off efficiency at a higher adjacent channel power ratio was improved, and improvement of 16 dB at 200 MHz frequency bandwidth was achieved for an 8 MS/s 64‐quadratic‐amplitude modulation signal.
- 18 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (21) , 24019-24027
Complex Permittivity Retrieval of Dispersive Liquids Based on Varactor-Loaded Split-Ring Resonator
A novel method has been evaluated to retrieve the dispersive dielectric constant versus frequency using a tunable metamaterial biosensor, which is designed and fabricated in this study. Varactor-loaded metamaterial resonators coupled micro-strip line form the main part of the structure. The presented structure consists of a split-ring resonator (SRR) and diode varactors loaded on SRRs. Diode varactor bias network is attached to the top layer, and the liquid under the test is contained inside the microfluidic channel. To retrieve the dispersive permittivity of the liquid, we considered a tunable sensor. The resonant frequency (fr) is affected by two parameters: sensor equivalent capacitance and inductance. We keep the second parameter constant and tune the first parameter by changing the varactor value from 0.44 pF up to 4.71 pF. The equivalent capacitance is also affected by the liquid permittivity value, which lets us measure the permittivity dispersion versus frequency. Our presented sensor can measure relative permittivity up to 100. As an example, four resonant frequencies, including 1.35, 1.5, 1.7, and 2.2 GHz, were selected to validate the sensor operation. In the experiment, varactor values are changed until resonant frequencies are shifted to the intended frs, then because of the known value of varicap the permittivities are estimated precisely according to the previously simulated results. This idea has been verified by water, oil, and ethanol to validate the sensor.
- 18 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (21) , 24019-24027
Complex Permittivity Retrieval of Dispersive Liquids Based on Varactor-Loaded Split-Ring Resonator
A novel method has been evaluated to retrieve the dispersive dielectric constant versus frequency using a tunable metamaterial biosensor, which is designed and fabricated in this study. Varactor-loaded metamaterial resonators coupled micro-strip line form the main part of the structure. The presented structure consists of a split-ring resonator (SRR) and diode varactors loaded on SRRs. Diode varactor bias network is attached to the top layer, and the liquid under the test is contained inside the microfluidic channel. To retrieve the dispersive permittivity of the liquid, we considered a tunable sensor. The resonant frequency (fr) is affected by two parameters: sensor equivalent capacitance and inductance. We keep the second parameter constant and tune the first parameter by changing the varactor value from 0.44 pF up to 4.71 pF. The equivalent capacitance is also affected by the liquid permittivity value, which lets us measure the permittivity dispersion versus frequency. Our presented sensor can measure relative permittivity up to 100. As an example, four resonant frequencies, including 1.35, 1.5, 1.7, and 2.2 GHz, were selected to validate the sensor operation. In the experiment, varactor values are changed until resonant frequencies are shifted to the intended frs, then because of the known value of varicap the permittivities are estimated precisely according to the previously simulated results. This idea has been verified by water, oil, and ethanol to validate the sensor.
- Open Access
- 2 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 37287-37296
A Simple and Adjustable Technique for Effective Linearization of Power Amplifiers Using Harmonic Injection
A simple and effective method for linearization of power amplifiers (PAs) is proposed. The method is based on the second harmonic injection into the input of the PA. The second harmonic is generated in a feedback path by taking the low-power transistors of a pseudo-differential pair amplifier to their nonlinear regime. The amplitude and phase of the second harmonics are controlled by tunable matching networks of the pseudo-differential pair which include trimmer capacitors. Using a theoretical analysis, we show that the proposed method is capable of canceling the third-order intermodulation signal at the PA output. As a proof of concept, a 10-W PA in a frequency band of 1.4 - 1.6 GHz is designed and linearized. By fabricating both the reference and linearized PAs and performing measurements under several conditions, it is experimentally demonstrated that applying the proposed scheme, thanks to its adjustability, highly linearizes the PA in a wide bandwidth and a wide range of output power.
- 2 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 37287-37296
Open AccessA Simple and Adjustable Technique for Effective Linearization of Power Amplifiers Using Harmonic Injection
A simple and effective method for linearization of power amplifiers (PAs) is proposed. The method is based on the second harmonic injection into the input of the PA. The second harmonic is generated in a feedback path by taking the low-power transistors of a pseudo-differential pair amplifier to their nonlinear regime. The amplitude and phase of the second harmonics are controlled by tunable matching networks of the pseudo-differential pair which include trimmer capacitors. Using a theoretical analysis, we show that the proposed method is capable of canceling the third-order intermodulation signal at the PA output. As a proof of concept, a 10-W PA in a frequency band of 1.4 - 1.6 GHz is designed and linearized. By fabricating both the reference and linearized PAs and performing measurements under several conditions, it is experimentally demonstrated that applying the proposed scheme, thanks to its adjustability, highly linearizes the PA in a wide bandwidth and a wide range of output power.
- 27 January 2021
- Published by Wiley in Advanced Optical Materials
- Vol. 9 (7) , 2001594
Time‐Modulated Metasurface‐Assisted Measurements
This paper explores time‐modulated metasurface‐assisted waveguide setups for the unique and accurate permittivity and permeability extraction of lossy dispersive samples with phase‐less measurements. It is theoretically demonstrated that when the position of the short‐circuit termination is dynamically modulated in a predefined way, the phase information of the reflection S‐parameter manifests itself into the amplitude level of the emerging harmonics. Being insensitive to the calibration plane shifts and phase uncertainties in reflection measurements while bypassing a priori knowledge about the material under test (MUT) and also the transmission information, can be regarded as the main advantages of the proposed time‐modulated material characterization approach. Using a simple post‐processing step, several illustrative examples are presented to numerically verify the validity of the proposed approach for some applicable and practical types of homogeneous materials. Two possible realization schemes based on mechanical actuation and electrical phase control are comprehensively discussed. An uncertainty analysis to examine how realization tolerances can affect the accuracy of results is also performed. The effectiveness of the proposed method is further experimentally demonstrated using a programmable phase‐agile metasurface. By involving the temporal dimension, the proposed strategy takes a great step forward in the phase‐less reconstruction of electromagnetic parameters.
- 27 January 2021
- Published by Wiley in Advanced Optical Materials
- Vol. 9 (7) , 2001594
Time‐Modulated Metasurface‐Assisted Measurements
This paper explores time‐modulated metasurface‐assisted waveguide setups for the unique and accurate permittivity and permeability extraction of lossy dispersive samples with phase‐less measurements. It is theoretically demonstrated that when the position of the short‐circuit termination is dynamically modulated in a predefined way, the phase information of the reflection S‐parameter manifests itself into the amplitude level of the emerging harmonics. Being insensitive to the calibration plane shifts and phase uncertainties in reflection measurements while bypassing a priori knowledge about the material under test (MUT) and also the transmission information, can be regarded as the main advantages of the proposed time‐modulated material characterization approach. Using a simple post‐processing step, several illustrative examples are presented to numerically verify the validity of the proposed approach for some applicable and practical types of homogeneous materials. Two possible realization schemes based on mechanical actuation and electrical phase control are comprehensively discussed. An uncertainty analysis to examine how realization tolerances can affect the accuracy of results is also performed. The effectiveness of the proposed method is further experimentally demonstrated using a programmable phase‐agile metasurface. By involving the temporal dimension, the proposed strategy takes a great step forward in the phase‐less reconstruction of electromagnetic parameters.