PGPengcheng Gan

Pengcheng Gan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pengcheng Gan has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Saturated‐core fault current limiters for AC power systems: Towards reliable, economical and better performance application

    by Jiaxin Yuan, Pengcheng Gan, Zhaoyang Zhang, Hang Zhou, Liangliang Wei, Kazuhiro Muramatsu

    With the continuous expansion of power grid capacity, the problem of short‐circuit current exceeding the standard is becoming increasingly serious. Fault current limiter is a promising solution and is gradually becoming a research hotspot. In this study, fault current limiters are classified into four categories. And saturated‐core fault current limiters are emphatically introduced, including its working principle and comparison with the other three categories. Saturated core fault current limiters are divided into four branches according to the ways leading the core saturated. A comprehensive review of the research activities and emerging technologies of saturated‐core fault current limiters for AC power systems is presented in this study. The working principle and typical structure of DC‐biased‐, permanent‐magnet‐, superconducting‐ and hybrid‐type saturated‐core fault current limiters are introduced. The advantages and disadvantages of four types of saturated core fault current limiters are compared in detail from the aspects of current‐limiting performance, iron core size and DC magnetomotive force. Real grid application examples of some types of devices are presented, as well as new progress in the techniques, are covered and discussed in detail. One may find the content of this study helpful as a detailed literature review or as practical technical guidance.


  • A Novel Six-Leg Three-Phase Fault Current Limiter

    by Jiaxin Yuan, Pengcheng Gan, Zhaoyang Zhang, Hang Zhou, Liangliang Wei, Kazuhiro Muramatsu

    A fault current limiter is an effective mean of limiting fault currents. The simultaneous use of three single-phase current limiters requires significant amounts of ferromagnetic material and space. This article proposes a three-phase saturated-core fault current limiter (T-SCFCL) that employs a common yoke and a permanent magnet to mitigate the restrictions of material and space. T-SCFCL delivers good performance for single-phase, two-phase, and three-phase faults. In this configuration, flux flowing through the permanent magnets is generated by a three-phase unbalanced current, thereby reducing the loss in eddy current and improving stability while significantly reducing the volume of the core. An algorithm is provided for use in the design of the FCL structure. A simulation was conducted based on the finite element method and a prototype manufactured and tested to verify effectiveness. The results prove that the proposed method is efficient.


  • Topology and Performance Optimization of a Novel Hybrid Material-Based Direct Current Fault Current Limiter

    by Hang Zhou, Jiaxin Yuan, Liangliang Wei, Pengcheng Gan, Fan Chen, Yongheng Zhong, Cuihua Tian, Baichao Chen, Yanhui Gao, Kazuhiro Muramatsu, et al.

    A novel direct current system fault current limiter (DCSFCL) based on the principle of nonlinear magnetization was proposed to limit fast rising fault current of the dc system. Different materials were also tested to find the iron core material. However, the existing material is not able to obtain both two necessary indexes, namely, a large saturation point and fast demagnetization speed. Hence, the performance is not satisfactory using a single material. In order to obtain the best performance for the DCSFCL, mixed materials were applied to combine the advantages of different soft magnetic materials. Furthermore, magnetic valves were also added to the original DCSFCL topology, which is an effective method to optimize the clipping performance and reduce the usage of materials. The 2-D models were built and finite-element analyses were carried out to verify these assumptions. Compared with a traditional smoothing reactor, the proposed new model not only limits the fault current by 55.4%, but also reduces the usage of both magnetic material and permanent magnets by over 20%.