Brett Allen Johnson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brett Allen Johnson has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- Jeffrey A. Cadeddu
University of Texas Southwestern Medical Center
5 shared publications - Ryan L. Steinberg
Department of Urology, University of Iowa Healthcare, Iowa City, IA
5 shared publications Margaret S. Pearle
Department of Urology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
4 shared publicationsJodi A. Antonelli
Division of Urology, Dept of Surgery, Duke University Medical Center, Durham, North Carolina, USA
3 shared publicationsAshley Gonzalez
Department of Urology, UT Southwestern Medical Center, Dallas, Texas, USA
2 shared publicationsHal D. Kominsky
Department of Urology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
2 shared publications
Latest Publications
- Open Access
- 10 February 2026
- Published by Elsevier in SSRN Electronic Journal
Ureteroscopic Aspiration Dynamics and Stone Fragment Evacuation: In Vitro Comparison of the Second-Generation CVAC System and Direct In-Scope Suction
Objective: To compare the aspiration efficiency and fragment evacuation performance of the second-generation CVAC aspiration system with direct in-scope suction (DISS) devices.Methods: Synthetic stones (Begostone) were sieved into five size groups (63 µm–3.3 mm). The CVAC catheter (7 Fr lumen) was tested against two DISS ureteroscopes (Pusen 3.6 Fr and 5.1 Fr). Standardized trials were performed using a Thermedx irrigation system (160 mmHg) and Neptune suction (155 mmHg). Endpoints included aspiration efficiency (g/min), clearance success within 180 s, time to clearance (Kaplan–Meier analysis), and clogging incidence.Results: CVAC achieved significantly higher aspiration efficiency than DISS across all fragment sizes (p < 0.01), with rates up to 41× greater (Group 4 vs. Pusen 3.6 Fr). Complete clearance within 180 s was achieved in 100% of CVAC trials for Groups 1–4 and in 25% of Group 5 runs, whereas both Pusen devices failed consistently in Groups 3–5. Kaplan–Meier analysis confirmed faster and more complete clearance with CVAC (median 49 s, 95% CI: 44–90 s), while neither Pusen device reached median clearance. Cox modeling showed the probability of clearance with Pusen devices was <25% that of CVAC. Only CVAC maintained partial or complete clearance when clogs occurred.Conclusions: The CVAC system outperformed DISS in aspiration efficiency, clearance rates, and time to clearance across multiple fragment sizes. These findings highlight the advantages of a dual-channel simultaneous irrigation–aspiration design compared to DISS systems. Further ex vivo and clinical studies are warranted to confirm these results in vivo.
- 10 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessUreteroscopic Aspiration Dynamics and Stone Fragment Evacuation: In Vitro Comparison of the Second-Generation CVAC System and Direct In-Scope Suction
Objective: To compare the aspiration efficiency and fragment evacuation performance of the second-generation CVAC aspiration system with direct in-scope suction (DISS) devices.Methods: Synthetic stones (Begostone) were sieved into five size groups (63 µm–3.3 mm). The CVAC catheter (7 Fr lumen) was tested against two DISS ureteroscopes (Pusen 3.6 Fr and 5.1 Fr). Standardized trials were performed using a Thermedx irrigation system (160 mmHg) and Neptune suction (155 mmHg). Endpoints included aspiration efficiency (g/min), clearance success within 180 s, time to clearance (Kaplan–Meier analysis), and clogging incidence.Results: CVAC achieved significantly higher aspiration efficiency than DISS across all fragment sizes (p < 0.01), with rates up to 41× greater (Group 4 vs. Pusen 3.6 Fr). Complete clearance within 180 s was achieved in 100% of CVAC trials for Groups 1–4 and in 25% of Group 5 runs, whereas both Pusen devices failed consistently in Groups 3–5. Kaplan–Meier analysis confirmed faster and more complete clearance with CVAC (median 49 s, 95% CI: 44–90 s), while neither Pusen device reached median clearance. Cox modeling showed the probability of clearance with Pusen devices was <25% that of CVAC. Only CVAC maintained partial or complete clearance when clogs occurred.Conclusions: The CVAC system outperformed DISS in aspiration efficiency, clearance rates, and time to clearance across multiple fragment sizes. These findings highlight the advantages of a dual-channel simultaneous irrigation–aspiration design compared to DISS systems. Further ex vivo and clinical studies are warranted to confirm these results in vivo.
- 21 August 2025
- Published by SAGE Publications in Journal of Endourology
- Vol. 39 (8) , 788-793
Unplanned Health Care Utilization after Ureteroscopy with Ureteral Stenting: Results from the Study to Enhance Understanding of Stent-Associated Symptoms Cohort
Background: Urinary stone disease (USD) often necessitates ureteroscopy with ureteral stenting. We assessed the frequency and risk factors associated with unplanned health care utilization related to ureteroscopy with ureteral stenting within 30 postoperative days, using data from the STudy to Enhance uNderstanding of sTent-associated Symptoms (STENTS), a prospective multicenter observational cohort study. Methods: Demographic, medical, surgical, and postoperative data were collected prospectively across four clinical centers for participants undergoing ureteroscopy for USD. Any utilization of health care (urgent care/emergency room or in-person clinical encounter) within 30 days was assessed for potential relationship to the stone procedure. We used univariable and multivariable logistic regression models to evaluate the associations between potential prespecified covariates and the primary outcome of unplanned encounter (UE). Results: A total of 484 participants (451 adults) underwent ureteroscopy (424 unilateral and 60 bilateral). Mean age was 49 years, and 47% were female. All postoperative clinical encounters within 30 days were reviewed to determine if they were unplanned and surgery related. Overall, 49 of the participants (10%) had at least one UE within 30 days, and 24/49 (49%) were an emergency room visit and/or hospitalization. Age, race, sex, and previous stone history were not statistically associated with a UE. Participants with a chronic pain condition were three times more likely to have a UE. Surgical duration, use of a ureteral access sheath, stent diameter, or irrigation method did not differ between the groups in a multivariable logistic model. Conclusions: The prevalence of unplanned health care utilization related to ureteroscopy and stenting for USD in our cohort was 10%. The presence of a chronic pain condition was an independent predictor of a UE. These findings may help identify patients at higher risk of utilizing health care resources following USD surgery and could enable proactive targeted interventions.
- 21 August 2025
- Published by SAGE Publications in Journal of Endourology
- Vol. 39 (8) , 788-793
Unplanned Health Care Utilization after Ureteroscopy with Ureteral Stenting: Results from the Study to Enhance Understanding of Stent-Associated Symptoms Cohort
Background: Urinary stone disease (USD) often necessitates ureteroscopy with ureteral stenting. We assessed the frequency and risk factors associated with unplanned health care utilization related to ureteroscopy with ureteral stenting within 30 postoperative days, using data from the STudy to Enhance uNderstanding of sTent-associated Symptoms (STENTS), a prospective multicenter observational cohort study. Methods: Demographic, medical, surgical, and postoperative data were collected prospectively across four clinical centers for participants undergoing ureteroscopy for USD. Any utilization of health care (urgent care/emergency room or in-person clinical encounter) within 30 days was assessed for potential relationship to the stone procedure. We used univariable and multivariable logistic regression models to evaluate the associations between potential prespecified covariates and the primary outcome of unplanned encounter (UE). Results: A total of 484 participants (451 adults) underwent ureteroscopy (424 unilateral and 60 bilateral). Mean age was 49 years, and 47% were female. All postoperative clinical encounters within 30 days were reviewed to determine if they were unplanned and surgery related. Overall, 49 of the participants (10%) had at least one UE within 30 days, and 24/49 (49%) were an emergency room visit and/or hospitalization. Age, race, sex, and previous stone history were not statistically associated with a UE. Participants with a chronic pain condition were three times more likely to have a UE. Surgical duration, use of a ureteral access sheath, stent diameter, or irrigation method did not differ between the groups in a multivariable logistic model. Conclusions: The prevalence of unplanned health care utilization related to ureteroscopy and stenting for USD in our cohort was 10%. The presence of a chronic pain condition was an independent predictor of a UE. These findings may help identify patients at higher risk of utilizing health care resources following USD surgery and could enable proactive targeted interventions.
- 1 March 2025
- Published by SAGE Publications in Journal of Endourology
- Vol. 39 (S1) , S8-S17
New Techniques and Technologies in Flexible Ureteroscopy
This article provides a step-by-step guide to flexible ureteroscopy (URS), with focus on some of the newer techniques and technologies available to facilitate treatment of complex stones. In it we review indications, preoperative evaluation, surgical steps, postoperative care, troubleshooting methods, and complication management. Furthermore, we will explore advances in laser technologies, the integration of suction mechanisms, and the incorporation of intrarenal pressure measurement systems in flexible URS.
- 1 March 2025
- Published by SAGE Publications in Journal of Endourology
- Vol. 39 (S1) , S8-S17
New Techniques and Technologies in Flexible Ureteroscopy
This article provides a step-by-step guide to flexible ureteroscopy (URS), with focus on some of the newer techniques and technologies available to facilitate treatment of complex stones. In it we review indications, preoperative evaluation, surgical steps, postoperative care, troubleshooting methods, and complication management. Furthermore, we will explore advances in laser technologies, the integration of suction mechanisms, and the incorporation of intrarenal pressure measurement systems in flexible URS.
- Top Cited PapersOpen Access
- 1 January 2025
- Published by SAGE Publications in Journal of Endourology
- Vol. 39 (1) , 10-18
A Prospective, Randomized, Noninferiority Study to Evaluate the Safety and Effectiveness of Steerable Ureteroscopic Renal Evacuation Compared with Standard Ureteroscopy: 30-Day Results of the ASPIRE Study
Purpose: We report the first multicenter, prospective, randomized noninferiority controlled trial of steerable ureteroscopic renal evacuation (SURE) for nephrolithiasis treatment. Materials and Methods: Candidates for laser lithotripsy ≥18 years with ≥1 renal stone ≥7 mm and 7–20 mm stone burden were randomized 1:1 SURE vs ureteroscopy (URS). SURE was performed using the CVAC Aspiration System, a novel steerable irrigation–aspiration catheter. The primary efficacy end point was noninferiority in stone-free rate (SFR) based on zero residual fragments (RFs) 30 days postprocedure on noncontrast computed tomography. Secondary end points were superiority tests, stone clearance (percent stone volume reduction), residual stone volume (RSV), SFR (no RF >2 mm), and SFR (no RF >4 mm) 30 days postprocedure. Results: Of the subjects, 123 were randomized and 101 qualified for efficacy analysis (SURE 46 vs URS 55). Despite randomization, baseline URS stone volume was higher (SURE 485.0 ± 432.5 mm 3 vs URS 713.3 ± 558.5 mm 3 ). The primary noninferiority end point was achieved (SURE SFR 48% vs URS SFR 49%, p = 0.027, −1.3% [90% confidence interval; −18%, 15%]). Stone clearance was significantly higher for SURE vs URS subjects (SURE 96.9 ± 5.6% vs URS 92.9 ± 11.6%, p = 0.036); RSV was significantly lower (SURE 14.3 ± 3 0.9 mm 3 vs URS 70.2 ± 144.9 mm 3 , p = 0.012). SURE stone clearance and RSV were independent of baseline stone volume, but for URS degraded with increasing baseline stone volume. Safety was comparable between groups. Conclusions: SFR for SURE subjects was noninferior compared with URS subjects; stone clearance and RSV were significantly better with SURE, independent of baseline stone volume.
- 1 January 2025
- Published by SAGE Publications in Journal of Endourology
- Vol. 39 (1) , 10-18
Top Cited PapersOpen AccessA Prospective, Randomized, Noninferiority Study to Evaluate the Safety and Effectiveness of Steerable Ureteroscopic Renal Evacuation Compared with Standard Ureteroscopy: 30-Day Results of the ASPIRE Study
Purpose: We report the first multicenter, prospective, randomized noninferiority controlled trial of steerable ureteroscopic renal evacuation (SURE) for nephrolithiasis treatment. Materials and Methods: Candidates for laser lithotripsy ≥18 years with ≥1 renal stone ≥7 mm and 7–20 mm stone burden were randomized 1:1 SURE vs ureteroscopy (URS). SURE was performed using the CVAC Aspiration System, a novel steerable irrigation–aspiration catheter. The primary efficacy end point was noninferiority in stone-free rate (SFR) based on zero residual fragments (RFs) 30 days postprocedure on noncontrast computed tomography. Secondary end points were superiority tests, stone clearance (percent stone volume reduction), residual stone volume (RSV), SFR (no RF >2 mm), and SFR (no RF >4 mm) 30 days postprocedure. Results: Of the subjects, 123 were randomized and 101 qualified for efficacy analysis (SURE 46 vs URS 55). Despite randomization, baseline URS stone volume was higher (SURE 485.0 ± 432.5 mm 3 vs URS 713.3 ± 558.5 mm 3 ). The primary noninferiority end point was achieved (SURE SFR 48% vs URS SFR 49%, p = 0.027, −1.3% [90% confidence interval; −18%, 15%]). Stone clearance was significantly higher for SURE vs URS subjects (SURE 96.9 ± 5.6% vs URS 92.9 ± 11.6%, p = 0.036); RSV was significantly lower (SURE 14.3 ± 3 0.9 mm 3 vs URS 70.2 ± 144.9 mm 3 , p = 0.012). SURE stone clearance and RSV were independent of baseline stone volume, but for URS degraded with increasing baseline stone volume. Safety was comparable between groups. Conclusions: SFR for SURE subjects was noninferior compared with URS subjects; stone clearance and RSV were significantly better with SURE, independent of baseline stone volume.
- 1 January 2025
- Published by SAGE Publications in Journal of Endourology
- Vol. 39 (1) , 26-33
Predictors of Persistent Residual Stones After Second Look Percutaneous Nephrolithotomy
Introduction: Second look flexible nephroscopy (SLFN) is often offered after percutaneous nephrolithotomy (PCNL). However, even after SLFN, residual fragments (RFs) occasionally persist. We sought to determine the incidence of persistent RFs in patients who undergo SLFN for RFs after PCNL and to identify parameters predictive of persistent RFs. Methods: We identified all patients at our institution with RFs on post-PCNL computed tomography (CT) that underwent SLFN between 1/2016 and 5/2020. Patient demographics, stone characteristics, and perioperative parameters were analyzed for each study patient. Post-SLFN fragments were identified on either follow-up kidney, ureter, and bladder radiograph or CT imaging obtained within 3 months of PCNL. Multivariable logistic regression analyses (MVA) was performed to identify predictors of persistent fragments. Results: A total of 201 renal units met the inclusion criteria. The median size of the largest RF at the time of SLFN was 5 mm (IQR 2–8) and the median cumulative RF stone size was 8 mm (IQR 5–14). The final stone-free rate of patients with RFs on initial PCNL who then underwent SLFN was 60.7% ( n = 122). The median cumulative RF stone size and the median size of the largest RF post SLFN was 6.5 mm (IQR 4–12) and 5 mm (IQR 3–8), respectively. On MVA, bilateral preoperative stones and greater RF stone burden at time of SLFN were independent predictors of radiographically detected post-SLFN fragments. Conclusions: Among patients who underwent SLFN for RFs after PCNL, 60% were rendered stone-free. Patients with bilateral stones prior to PCNL and greater RF stone burden at time of SLFN are more likely to have persistent fragments, despite attempts at aggressive stone removal during both the initial PCNL and subsequent SLFN. The risk of adverse stone events from such fragments is unknown and may be lower because of their inaccessibility.
- 1 January 2025
- Published by SAGE Publications in Journal of Endourology
- Vol. 39 (1) , 26-33
Predictors of Persistent Residual Stones After Second Look Percutaneous Nephrolithotomy
Introduction: Second look flexible nephroscopy (SLFN) is often offered after percutaneous nephrolithotomy (PCNL). However, even after SLFN, residual fragments (RFs) occasionally persist. We sought to determine the incidence of persistent RFs in patients who undergo SLFN for RFs after PCNL and to identify parameters predictive of persistent RFs. Methods: We identified all patients at our institution with RFs on post-PCNL computed tomography (CT) that underwent SLFN between 1/2016 and 5/2020. Patient demographics, stone characteristics, and perioperative parameters were analyzed for each study patient. Post-SLFN fragments were identified on either follow-up kidney, ureter, and bladder radiograph or CT imaging obtained within 3 months of PCNL. Multivariable logistic regression analyses (MVA) was performed to identify predictors of persistent fragments. Results: A total of 201 renal units met the inclusion criteria. The median size of the largest RF at the time of SLFN was 5 mm (IQR 2–8) and the median cumulative RF stone size was 8 mm (IQR 5–14). The final stone-free rate of patients with RFs on initial PCNL who then underwent SLFN was 60.7% ( n = 122). The median cumulative RF stone size and the median size of the largest RF post SLFN was 6.5 mm (IQR 4–12) and 5 mm (IQR 3–8), respectively. On MVA, bilateral preoperative stones and greater RF stone burden at time of SLFN were independent predictors of radiographically detected post-SLFN fragments. Conclusions: Among patients who underwent SLFN for RFs after PCNL, 60% were rendered stone-free. Patients with bilateral stones prior to PCNL and greater RF stone burden at time of SLFN are more likely to have persistent fragments, despite attempts at aggressive stone removal during both the initial PCNL and subsequent SLFN. The risk of adverse stone events from such fragments is unknown and may be lower because of their inaccessibility.
- Open Access
- 13 August 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (09) , 093506-15
Design and validation of a high-speed hyperspectral laparoscopic imaging system
Laparoscopic and robotic surgery has been increasing in prevalence across all surgical specialties for decades, in fields that include urology,1 neurology,2 and gynecology.3 This has resulted in shorter hospital stays, decreased intraoperative blood loss, and decreased infection rates in patients.4,5 As minimally invasive surgery (MIS) and techniques have evolved and improved, surgical robotics and novel imaging systems have further advanced the field and enhanced surgeon capabilities in various procedures. This includes the development of fluorescence imaging (FI) systems,6 3D stereoscopic visualization technology,7 and narrow-band imaging (NBI) tools,8 all of which have been incorporated into MIS imaging systems with the hope of reducing adverse outcomes such as anastomotic leakage occurrence rates,9 iatrogenic injuries,10 and positive tumor margins.11 As these technologies have been shown to improve surgical outcomes, they have seen increased translation in modern, clinical systems. As such, we will briefly cover each in more depth.
- 13 August 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (09) , 093506-15
Open AccessDesign and validation of a high-speed hyperspectral laparoscopic imaging system
Laparoscopic and robotic surgery has been increasing in prevalence across all surgical specialties for decades, in fields that include urology,1 neurology,2 and gynecology.3 This has resulted in shorter hospital stays, decreased intraoperative blood loss, and decreased infection rates in patients.4,5 As minimally invasive surgery (MIS) and techniques have evolved and improved, surgical robotics and novel imaging systems have further advanced the field and enhanced surgeon capabilities in various procedures. This includes the development of fluorescence imaging (FI) systems,6 3D stereoscopic visualization technology,7 and narrow-band imaging (NBI) tools,8 all of which have been incorporated into MIS imaging systems with the hope of reducing adverse outcomes such as anastomotic leakage occurrence rates,9 iatrogenic injuries,10 and positive tumor margins.11 As these technologies have been shown to improve surgical outcomes, they have seen increased translation in modern, clinical systems. As such, we will briefly cover each in more depth.
- 1 October 2023
- Published by SAGE Publications in Journal of Endourology
- Vol. 37 (10) , 1139-1144
Prospective Randomized Trial of Single-Use vs Reusable Cystoscope for Ureteral Stent Removal
Background Reusable cystoscopes are associated with risks of cross-contamination, need for chemical reprocessing, mechanical breakdown, maintenance costs and labor for cleaning. A sterile, single use cystoscope may reduce or eliminate the source of these infections, while also decreasing exposure to reprocessing chemical agents. In this multicenter, prospective randomized trial, we sought to compare single use to reusable endoscopes for ureteral stent removal. Methods A three-center prospective, randomized, dual-arm post-market clinical trial was performed to compare the single-use cystoscope (Ambu A/S) to standard of care flexible reusable cystoscopes for outpatient ureteral stent removal. 102 patients were randomized and evaluated from baseline through day 10 post-procedure. Primary endpoint was the successful stent removal. Secondary endpoints were time from preparation to disposal/reprocessing, adverse events, and clinician satisfaction. Results 102 subjects were randomized in a 1:1 fashion. The successful stent removal rate was 51/51 (Reusable) and 50/51 (Single use). One patient required the conversion to reusable scope due to grasper passage issue. Median time from prep for the procedure to disposal/prep for reprocessing was 10.2 minutes for the single-use and 18.4 minutes for the reusable (p<0.001). There was no difference in clinician satisfaction between both arms. There was no difference in adverse events between arms and no device causal attribution for any AE reports. There was one serious adverse event requiring hospitalization for infection in the reusable arm. Conclusions The RCT of single-use cystoscopes vs. reusables showed comparable device success with significant time savings for single-use and equivalent clinician satisfaction.
- 1 October 2023
- Published by SAGE Publications in Journal of Endourology
- Vol. 37 (10) , 1139-1144
Prospective Randomized Trial of Single-Use vs Reusable Cystoscope for Ureteral Stent Removal
Background Reusable cystoscopes are associated with risks of cross-contamination, need for chemical reprocessing, mechanical breakdown, maintenance costs and labor for cleaning. A sterile, single use cystoscope may reduce or eliminate the source of these infections, while also decreasing exposure to reprocessing chemical agents. In this multicenter, prospective randomized trial, we sought to compare single use to reusable endoscopes for ureteral stent removal. Methods A three-center prospective, randomized, dual-arm post-market clinical trial was performed to compare the single-use cystoscope (Ambu A/S) to standard of care flexible reusable cystoscopes for outpatient ureteral stent removal. 102 patients were randomized and evaluated from baseline through day 10 post-procedure. Primary endpoint was the successful stent removal. Secondary endpoints were time from preparation to disposal/reprocessing, adverse events, and clinician satisfaction. Results 102 subjects were randomized in a 1:1 fashion. The successful stent removal rate was 51/51 (Reusable) and 50/51 (Single use). One patient required the conversion to reusable scope due to grasper passage issue. Median time from prep for the procedure to disposal/prep for reprocessing was 10.2 minutes for the single-use and 18.4 minutes for the reusable (p<0.001). There was no difference in clinician satisfaction between both arms. There was no difference in adverse events between arms and no device causal attribution for any AE reports. There was one serious adverse event requiring hospitalization for infection in the reusable arm. Conclusions The RCT of single-use cystoscopes vs. reusables showed comparable device success with significant time savings for single-use and equivalent clinician satisfaction.
- 24 May 2023
- Published by SAGE Publications in Journal of Endourology
- Vol. 37 (7) , 828-833
Toll-like receptor 4 induction during renal ischemia correlates with serum creatinine in a pig model
Objectives: To determine whether toll-like receptor 4 (TLR4), a mediator of organ ischemia-reperfusion injury (IRI), is overexpressed during warm ischemia in a porcine solitary kidney model, and whether its expression correlates with creatinine, a surrogate for kidney function. Materials and methods: Eight adult Yorkshire pigs underwent initial laparoscopic nephrectomy. After 1 week, animals were randomized into 2 groups: group 1 underwent laparoscopic renal hilar dissection, renal ischemia by cross-clamping, and reperfusion (ischemia group); group 2 underwent laparoscopic renal hilar dissection alone (sham group). Animals were survived to day 7 post-randomization. Peripheral blood was sampled for serum creatinine (sCr) and TLR4 expression at the following time points or corresponding intervals: pre-nephrectomy, 1-week post-nephrectomy (pre-ischemia), after 90 minutes of ischemia, 30 minutes post-reperfusion and at sacrifice. Intra-group TLR4 expression changes were analyzed using repeated measures ANOVA. Inter-group TLR4 expression was compared using Mann-Whitney’s test. Correlation between sCr and TLR4 was assessed using Spearman’s test. Results: Seven animals successfully completed the experiment (4 ischemia, 3 sham). Relative TLR4 expression significantly increased from baseline levels during ischemia, reperfusion and sacrifice time points only in the ischemia group, and was significantly higher for the ischemia group after 90 minutes of ischemia (p=0.034). sCr was significantly higher for the ischemia group during the reperfusion phase (p=0.048). Relative TLR4 expression level significantly correlated with sCr in the overall cohort (Spearman’s rho = 0.69) and in the ischemia group (Spearman’s rho = 0.82), (p<0.0001 for each). Conclusions: Warm ischemia in a porcine solitary kidney induces acute overexpression of TLR4 in peripheral blood leukocytes which is detectable. Relative TLR4 expression level strongly correlated with sCr, but had an observable change sooner than change in sCr. Pending further investigation, TLR4 overexpression during renal ischemia may represent a sensitive, quantitative marker of unilateral renal injury sustained during nephron-sparing surgery.
- 24 May 2023
- Published by SAGE Publications in Journal of Endourology
- Vol. 37 (7) , 828-833
Toll-like receptor 4 induction during renal ischemia correlates with serum creatinine in a pig model
Objectives: To determine whether toll-like receptor 4 (TLR4), a mediator of organ ischemia-reperfusion injury (IRI), is overexpressed during warm ischemia in a porcine solitary kidney model, and whether its expression correlates with creatinine, a surrogate for kidney function. Materials and methods: Eight adult Yorkshire pigs underwent initial laparoscopic nephrectomy. After 1 week, animals were randomized into 2 groups: group 1 underwent laparoscopic renal hilar dissection, renal ischemia by cross-clamping, and reperfusion (ischemia group); group 2 underwent laparoscopic renal hilar dissection alone (sham group). Animals were survived to day 7 post-randomization. Peripheral blood was sampled for serum creatinine (sCr) and TLR4 expression at the following time points or corresponding intervals: pre-nephrectomy, 1-week post-nephrectomy (pre-ischemia), after 90 minutes of ischemia, 30 minutes post-reperfusion and at sacrifice. Intra-group TLR4 expression changes were analyzed using repeated measures ANOVA. Inter-group TLR4 expression was compared using Mann-Whitney’s test. Correlation between sCr and TLR4 was assessed using Spearman’s test. Results: Seven animals successfully completed the experiment (4 ischemia, 3 sham). Relative TLR4 expression significantly increased from baseline levels during ischemia, reperfusion and sacrifice time points only in the ischemia group, and was significantly higher for the ischemia group after 90 minutes of ischemia (p=0.034). sCr was significantly higher for the ischemia group during the reperfusion phase (p=0.048). Relative TLR4 expression level significantly correlated with sCr in the overall cohort (Spearman’s rho = 0.69) and in the ischemia group (Spearman’s rho = 0.82), (p<0.0001 for each). Conclusions: Warm ischemia in a porcine solitary kidney induces acute overexpression of TLR4 in peripheral blood leukocytes which is detectable. Relative TLR4 expression level strongly correlated with sCr, but had an observable change sooner than change in sCr. Pending further investigation, TLR4 overexpression during renal ischemia may represent a sensitive, quantitative marker of unilateral renal injury sustained during nephron-sparing surgery.
- 29 March 2023
- Published by Wolters Kluwer Health in Current Opinion in Urology
- Vol. 33 (4) , 345-350
Percutaneous management of ureteropelvic junction obstruction
Purpose of review: The development of endoscopic and minimally invasive techniques has revolutionized the treatment of ureteropelvic junction obstruction (UPJO). Patients can now undergo successful UPJO repair without the morbidity and complications associated with open surgery. Laparoscopic and robotic repair has supplanted open surgery as the gold standard, but percutaneous endoscopic treatment remains a relevant alternative to more invasive surgery. This review will focus on the percutaneous approach for the treatment of UPJO. Recent findings: Percutaneous endopyelotomy was popularized during the 1980 s due to advances in the field of endourology, allowing for well tolerated and reliable percutaneous access to the kidney. After percutaneous access to the kidney is achieved, the narrowed ureter at the UPJ is incised in a full thickness fashion in the posterolateral position from the ureteral lumen to the periureteral fat. Success rates for this procedure are nearly 90% at high-volume centres. The ideal patient who has success with percutaneous endopyelotomy has a short segment of narrowing less than 2 cm, no crossing vessel, good ipsilateral renal function and mild hydronephrosis. Summary: Although the development of laparoscopic and robotic approaches to pyeloplasty has produced outcomes that surpass those of percutaneous endopyelotomy, it remains a viable option in the appropriately selected patient, but success rates tend to decrease with longer follow up.
- 29 March 2023
- Published by Wolters Kluwer Health in Current Opinion in Urology
- Vol. 33 (4) , 345-350
Percutaneous management of ureteropelvic junction obstruction
Purpose of review: The development of endoscopic and minimally invasive techniques has revolutionized the treatment of ureteropelvic junction obstruction (UPJO). Patients can now undergo successful UPJO repair without the morbidity and complications associated with open surgery. Laparoscopic and robotic repair has supplanted open surgery as the gold standard, but percutaneous endoscopic treatment remains a relevant alternative to more invasive surgery. This review will focus on the percutaneous approach for the treatment of UPJO. Recent findings: Percutaneous endopyelotomy was popularized during the 1980 s due to advances in the field of endourology, allowing for well tolerated and reliable percutaneous access to the kidney. After percutaneous access to the kidney is achieved, the narrowed ureter at the UPJ is incised in a full thickness fashion in the posterolateral position from the ureteral lumen to the periureteral fat. Success rates for this procedure are nearly 90% at high-volume centres. The ideal patient who has success with percutaneous endopyelotomy has a short segment of narrowing less than 2 cm, no crossing vessel, good ipsilateral renal function and mild hydronephrosis. Summary: Although the development of laparoscopic and robotic approaches to pyeloplasty has produced outcomes that surpass those of percutaneous endopyelotomy, it remains a viable option in the appropriately selected patient, but success rates tend to decrease with longer follow up.