Stanley Normile
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stanley Normile has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Conor Perks
Plasma Science and Fusion Center, Massachusetts Institute of Technology 1 , Cambridge, Massachusetts 02139
5 shared publications - D. Vezinet
Commonwealth Fusion Systems, Devens, MA, United States of America
5 shared publications - John E. Rice
Massachusetts Institute of Technology
5 shared publications - Francesca Bombarda
Department of Industrial Engineering, University of Rome “Tor Vergata” 6 , Rome
3 shared publications - Gianluca Verona Rinati
University of Rome "Tor Vergata
3 shared publications - Iryna V. Zenyuk
University of California
3 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Design of a diamond-based in-vessel soft x-ray camera system for the SPARC tokamak
Soft x-ray tomography has been used in tokamaks for decades to interrogate a wide variety of phenomena; however, the standard silicon diodes coupled with beryllium filters will not be able to survive the high heat and neutron fluxes present in burning plasma devices like SPARC. Presented here is the design for a set of soft x-ray tomography cameras that use chemical vapor deposition (CVD) single-crystal diamonds and graphene filters for photodetection. Four of these cameras will be placed in the port plugs of SPARC with a large enough view of the poloidal cross section to enable tomographic inversion and sufficient time resolution to resolve the dynamics of low-m and -n magnetohydrodynamic modes. CVD diamonds have been used successfully for the detection of both vacuum ultraviolet and soft x-ray photons at the Frascati Tokamak Upgrade and have demonstrated the ability to maintain greater than 50% of their initial responsivity at a neutron fluence of 1016 cm−2. The neutron dose in SPARC will exceed this limit, providing a demonstration of how CVD diamonds fail in place while adding value to the early operation of a new tokamak. Numerical simulations indicate that graphene spectral filters will filter nearly as effectively as traditional beryllium ones and are able to resist significantly higher heat fluxes due to graphene’s unique thermal properties. Simulated plasma emissivity profiles have been used to optimize both the camera placement and detector properties.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Open AccessDesign of a diamond-based in-vessel soft x-ray camera system for the SPARC tokamak
Soft x-ray tomography has been used in tokamaks for decades to interrogate a wide variety of phenomena; however, the standard silicon diodes coupled with beryllium filters will not be able to survive the high heat and neutron fluxes present in burning plasma devices like SPARC. Presented here is the design for a set of soft x-ray tomography cameras that use chemical vapor deposition (CVD) single-crystal diamonds and graphene filters for photodetection. Four of these cameras will be placed in the port plugs of SPARC with a large enough view of the poloidal cross section to enable tomographic inversion and sufficient time resolution to resolve the dynamics of low-m and -n magnetohydrodynamic modes. CVD diamonds have been used successfully for the detection of both vacuum ultraviolet and soft x-ray photons at the Frascati Tokamak Upgrade and have demonstrated the ability to maintain greater than 50% of their initial responsivity at a neutron fluence of 1016 cm−2. The neutron dose in SPARC will exceed this limit, providing a demonstration of how CVD diamonds fail in place while adding value to the early operation of a new tokamak. Numerical simulations indicate that graphene spectral filters will filter nearly as effectively as traditional beryllium ones and are able to resist significantly higher heat fluxes due to graphene’s unique thermal properties. Simulated plasma emissivity profiles have been used to optimize both the camera placement and detector properties.
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
Hard-x-ray diamond sensors for in-flight runaway electron detection on SPARC
This paper presents the design of a pair of in-vessel x-ray cameras for SPARC. These cameras have mirrored tangential toroidal views and aim to measure the anisotropic thin-target bremsstrahlung emitted by runaway electrons interacting with the background plasma in the 10–30 keV range. This diagnostic is planned as one of the safeguards against off-normal current ramp-up scenarios, in particular during early SPARC operation. The motivations behind this diagnostic are presented, and the design is detailed with an emphasis on constraints specific to SPARC.
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
Hard-x-ray diamond sensors for in-flight runaway electron detection on SPARC
This paper presents the design of a pair of in-vessel x-ray cameras for SPARC. These cameras have mirrored tangential toroidal views and aim to measure the anisotropic thin-target bremsstrahlung emitted by runaway electrons interacting with the background plasma in the 10–30 keV range. This diagnostic is planned as one of the safeguards against off-normal current ramp-up scenarios, in particular during early SPARC operation. The motivations behind this diagnostic are presented, and the design is detailed with an emphasis on constraints specific to SPARC.
- Open Access
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Overview of the early campaign diagnostics for the SPARC tokamak (invited)
The SPARC tokamak is a high-field, Bt0 ∼12 T, medium-sized, R0 = 1.85 m, tokamak that is presently under construction in Devens, MA, led by Commonwealth Fusion Systems. It will be used to de-risk the high-field tokamak path to a fusion power plant and demonstrate the commercial viability of fusion energy. SPARC’s first campaign plan is to achieve Qfus > 1 using an ICRF-heated, 15 m from the center of the tokamak, on the other side of a 2.4 m concrete shielding wall. A series of 31 large-scale penetrations have been included in the SPARC Tokamak Hall to facilitate integration of early campaign diagnostics and to provide upgradability.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Open AccessOverview of the early campaign diagnostics for the SPARC tokamak (invited)
The SPARC tokamak is a high-field, Bt0 ∼12 T, medium-sized, R0 = 1.85 m, tokamak that is presently under construction in Devens, MA, led by Commonwealth Fusion Systems. It will be used to de-risk the high-field tokamak path to a fusion power plant and demonstrate the commercial viability of fusion energy. SPARC’s first campaign plan is to achieve Qfus > 1 using an ICRF-heated, 15 m from the center of the tokamak, on the other side of a 2.4 m concrete shielding wall. A series of 31 large-scale penetrations have been included in the SPARC Tokamak Hall to facilitate integration of early campaign diagnostics and to provide upgradability.
- Open Access
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Design of a diamond-based in-vessel soft x-ray detector for the SPARC tokamak
The in-vessel silicon diode arrays that are used for soft x-ray detection in many tokamaks are sensitive to neutron damage, making them unsuitable for burning plasma devices such as SPARC. In such a device, the silicon diodes would need to be placed far from the plasma—limiting their field of view—or an alternative detector could be used. Here, we present the design of a camera containing an array of chemical vapor deposition single-crystal diamonds, which will be placed in the upper and lower port plugs of the SPARC tokamak with a large enough view of the poloidal cross section to enable tomographic inversion. The camera design presented here is optimized to provide a wide field of view of the poloidal cross section. Simulated plasma conditions are used to estimate the x-ray signal that this detector array will receive and to fine-tune the camera placement within the tokamak.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Open AccessDesign of a diamond-based in-vessel soft x-ray detector for the SPARC tokamak
The in-vessel silicon diode arrays that are used for soft x-ray detection in many tokamaks are sensitive to neutron damage, making them unsuitable for burning plasma devices such as SPARC. In such a device, the silicon diodes would need to be placed far from the plasma—limiting their field of view—or an alternative detector could be used. Here, we present the design of a camera containing an array of chemical vapor deposition single-crystal diamonds, which will be placed in the upper and lower port plugs of the SPARC tokamak with a large enough view of the poloidal cross section to enable tomographic inversion. The camera design presented here is optimized to provide a wide field of view of the poloidal cross section. Simulated plasma conditions are used to estimate the x-ray signal that this detector array will receive and to fine-tune the camera placement within the tokamak.
- Open Access
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
SPARC x-ray diagnostics: Technical and functional overview
An overview is given of SPARC’s three main x-ray diagnostics, with a focus on the functions they fulfill with respect to tokamak operation. The first is an in-vessel soft x-ray tomography diagnostic, aimed at providing early campaign information on plasma position, MHD activity, and impurity content. The second is an ex-vessel set of hard x-ray scintillators aimed at detecting the presence of runaway electrons, in particular during plasma startup phases. The third is a set of x-ray Bragg spectrometers, located outside of the tokamak hall, aimed at informing on the ion temperature as an indirect constraint to reduce uncertainties on the fusion power, on providing plasma rotation velocity estimates, and on observing impurity emission. Finally, more technical details are given on the beamlines at the end of which the spectrometers are located. It explains how their design allows us to ensure tritium containment and limit neutron radiation while providing a straight view into the plasma that can also be used for testing new innovative sensors.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Open AccessSPARC x-ray diagnostics: Technical and functional overview
An overview is given of SPARC’s three main x-ray diagnostics, with a focus on the functions they fulfill with respect to tokamak operation. The first is an in-vessel soft x-ray tomography diagnostic, aimed at providing early campaign information on plasma position, MHD activity, and impurity content. The second is an ex-vessel set of hard x-ray scintillators aimed at detecting the presence of runaway electrons, in particular during plasma startup phases. The third is a set of x-ray Bragg spectrometers, located outside of the tokamak hall, aimed at informing on the ion temperature as an indirect constraint to reduce uncertainties on the fusion power, on providing plasma rotation velocity estimates, and on observing impurity emission. Finally, more technical details are given on the beamlines at the end of which the spectrometers are located. It explains how their design allows us to ensure tritium containment and limit neutron radiation while providing a straight view into the plasma that can also be used for testing new innovative sensors.
- 1 July 2019
- Published by Elsevier in Solid State Ionics
- Vol. 335, 38-46
Imaging ionomer in fuel cell catalyst layers with synchrotron nano transmission x-ray microscopy
- 1 July 2019
- Published by Elsevier in Solid State Ionics
- Vol. 335, 38-46
Imaging ionomer in fuel cell catalyst layers with synchrotron nano transmission x-ray microscopy
- 1 September 2018
- Published by Elsevier in Materials Today Energy
- Vol. 9, 187-197
Direct observations of liquid water formation at nano- and micro-scale in platinum group metal-free electrodes by operando X-ray computed tomography
- 1 September 2018
- Published by Elsevier in Materials Today Energy
- Vol. 9, 187-197
Direct observations of liquid water formation at nano- and micro-scale in platinum group metal-free electrodes by operando X-ray computed tomography
- 20 July 2018
- Published by Royal Society of Chemistry (RSC) in Sustainable Energy & Fuels
- Vol. 2 (10) , 2268-2275
Nickel–copper supported on a carbon black hydrogen oxidation catalyst integrated into an anion-exchange membrane fuel cell
This work introduces the first practical platinum group metal-free (PGM-free) electrocatalyst for the hydrogen oxidation reaction (HOR) in alkaline membrane fuel cells (AMFC), based on nickel-rich Ni 95 Cu 5 -alloy nanoparticles.
- 20 July 2018
- Published by Royal Society of Chemistry (RSC) in Sustainable Energy & Fuels
- Vol. 2 (10) , 2268-2275
Nickel–copper supported on a carbon black hydrogen oxidation catalyst integrated into an anion-exchange membrane fuel cell
This work introduces the first practical platinum group metal-free (PGM-free) electrocatalyst for the hydrogen oxidation reaction (HOR) in alkaline membrane fuel cells (AMFC), based on nickel-rich Ni 95 Cu 5 -alloy nanoparticles.
- 1 June 2018
- Published by Elsevier in Electrochimica Acta
- Vol. 276, 424-433
Operando X-ray tomography and sub-second radiography for characterizing transport in polymer electrolyte membrane electrolyzer
- 1 June 2018
- Published by Elsevier in Electrochimica Acta
- Vol. 276, 424-433
Operando X-ray tomography and sub-second radiography for characterizing transport in polymer electrolyte membrane electrolyzer