MCMegan Suzanne Claflin

Megan Suzanne Claflin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Megan Suzanne Claflin has a total of 231 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comment on egusphere-2026-6002

    by Megan S. Claflin, Felipe Lopez-Hilfiker, Urs Rohner, Vasyl Yatsyna, Brian M. Lerner, Joel Thornton, Douglas Worsnop, Manjula Canagaratna, John Jayne

    Volatile organic compounds (VOCs) play important roles in atmospheric chemistry and air quality, but measurements often require a tradeoff between temporal resolution, molecular specificity, and instrument size and complexity. Online chemical-ionization mass spectrometry provides sensitive, rapid measurements but can be affected by isomeric contributions, fragmentation, and other ion-chemistry interferences, whereas gas chromatography (GC) provides molecular separation and specificity at lower temporal resolution. Here, we present a compact, low-power VOC measurement system that combines in-situ gas chromatography and thermal desorption (TD) preconcentration with a newly developed ultracompact proton-transfer-reaction time-of-flight mass spectrometer (PTR-TOF-MS) equipped with a novel vacuum-ultraviolet (VUV) ion source. The complete system occupies a 50 x 65 x 55 cm space, weighs < 70 kg, and consumes < 600 W of power during typical operation. The instrument combines high-time resolution, direct PTR measurements with periodic chromatographic measurements for regular molecular speciation. The system was operated continuously for 30 days in Thun, Switzerland with stable calibrant response (average variation of 3.5 %) during the ambient measurement period, with demonstrated direct-PTR limits of detection (LODs) of 13 – 136 ppt (1-min) and GC-PTR LODs of 0.1 – 4.0 ppt (1 L sample) across 11 calibrants. Together, these results demonstrate a complementary approach to instrument miniaturization in which reduced detector performance can be offset by upstream analytical separation and preconcentration. In this configuration, the direct PTR measurement provides high-time resolution observations, while periodic chromatographic measurements provide molecular specificity, sensitivity enhancement, and information on analyte-specific ion chemistry and interferences. By reducing the size, power requirements, and operational complexity, this system provides a pathway toward broader deployment of chemically specific VOC measurements at long-term monitoring sites, on mobile platforms, and in locations where infrastructure or reliable power is limited, to investigate emission sources, atmospheric processing, and the formation of secondary pollutants.

  • Open Access

    Comment on egusphere-2026-6002

    by Megan S. Claflin, Felipe Lopez-Hilfiker, Urs Rohner, Vasyl Yatsyna, Brian M. Lerner, Joel Thornton, Douglas Worsnop, Manjula Canagaratna, John Jayne

    Volatile organic compounds (VOCs) play important roles in atmospheric chemistry and air quality, but measurements often require a tradeoff between temporal resolution, molecular specificity, and instrument size and complexity. Online chemical-ionization mass spectrometry provides sensitive, rapid measurements but can be affected by isomeric contributions, fragmentation, and other ion-chemistry interferences, whereas gas chromatography (GC) provides molecular separation and specificity at lower temporal resolution. Here, we present a compact, low-power VOC measurement system that combines in-situ gas chromatography and thermal desorption (TD) preconcentration with a newly developed ultracompact proton-transfer-reaction time-of-flight mass spectrometer (PTR-TOF-MS) equipped with a novel vacuum-ultraviolet (VUV) ion source. The complete system occupies a 50 x 65 x 55 cm space, weighs < 70 kg, and consumes < 600 W of power during typical operation. The instrument combines high-time resolution, direct PTR measurements with periodic chromatographic measurements for regular molecular speciation. The system was operated continuously for 30 days in Thun, Switzerland with stable calibrant response (average variation of 3.5 %) during the ambient measurement period, with demonstrated direct-PTR limits of detection (LODs) of 13 – 136 ppt (1-min) and GC-PTR LODs of 0.1 – 4.0 ppt (1 L sample) across 11 calibrants. Together, these results demonstrate a complementary approach to instrument miniaturization in which reduced detector performance can be offset by upstream analytical separation and preconcentration. In this configuration, the direct PTR measurement provides high-time resolution observations, while periodic chromatographic measurements provide molecular specificity, sensitivity enhancement, and information on analyte-specific ion chemistry and interferences. By reducing the size, power requirements, and operational complexity, this system provides a pathway toward broader deployment of chemically specific VOC measurements at long-term monitoring sites, on mobile platforms, and in locations where infrastructure or reliable power is limited, to investigate emission sources, atmospheric processing, and the formation of secondary pollutants.

  • Open Access

    Comment on egusphere-2026-6002

    by Megan S. Claflin, Felipe Lopez-Hilfiker, Urs Rohner, Vasyl Yatsyna, Brian M. Lerner, Joel Thornton, Douglas Worsnop, Manjula Canagaratna, John Jayne

    Volatile organic compounds (VOCs) play important roles in atmospheric chemistry and air quality, but measurements often require a tradeoff between temporal resolution, molecular specificity, and instrument size and complexity. Online chemical-ionization mass spectrometry provides sensitive, rapid measurements but can be affected by isomeric contributions, fragmentation, and other ion-chemistry interferences, whereas gas chromatography (GC) provides molecular separation and specificity at lower temporal resolution. Here, we present a compact, low-power VOC measurement system that combines in-situ gas chromatography and thermal desorption (TD) preconcentration with a newly developed ultracompact proton-transfer-reaction time-of-flight mass spectrometer (PTR-TOF-MS) equipped with a novel vacuum-ultraviolet (VUV) ion source. The complete system occupies a 50 x 65 x 55 cm space, weighs < 70 kg, and consumes < 600 W of power during typical operation. The instrument combines high-time resolution, direct PTR measurements with periodic chromatographic measurements for regular molecular speciation. The system was operated continuously for 30 days in Thun, Switzerland with stable calibrant response (average variation of 3.5 %) during the ambient measurement period, with demonstrated direct-PTR limits of detection (LODs) of 13 – 136 ppt (1-min) and GC-PTR LODs of 0.1 – 4.0 ppt (1 L sample) across 11 calibrants. Together, these results demonstrate a complementary approach to instrument miniaturization in which reduced detector performance can be offset by upstream analytical separation and preconcentration. In this configuration, the direct PTR measurement provides high-time resolution observations, while periodic chromatographic measurements provide molecular specificity, sensitivity enhancement, and information on analyte-specific ion chemistry and interferences. By reducing the size, power requirements, and operational complexity, this system provides a pathway toward broader deployment of chemically specific VOC measurements at long-term monitoring sites, on mobile platforms, and in locations where infrastructure or reliable power is limited, to investigate emission sources, atmospheric processing, and the formation of secondary pollutants.

  • Open Access

    Supplementary material to "Bridging temporal resolution and molecular specificity with a compact GC-PTR for the measurement of volatile organic compounds"

    by Megan S. Claflin, Felipe Lopez-Hilfiker, Urs Rohner, Vasyl Yatsyna, Brian M. Lerner, Joel Thornton, Douglas Worsnop, Manjula Canagaratna, John Jayne

  • Open Access

    Bridging temporal resolution and molecular specificity with a compact GC-PTR for the measurement of volatile organic compounds

    by Megan S. Claflin, Felipe Lopez-Hilfiker, Urs Rohner, Vasyl Yatsyna, Brian M. Lerner, Joel Thornton, Douglas Worsnop, Manjula Canagaratna, John Jayne

    Volatile organic compounds (VOCs) play important roles in atmospheric chemistry and air quality, but measurements often require a tradeoff between temporal resolution, molecular specificity, and instrument size and complexity. Online chemical-ionization mass spectrometry provides sensitive, rapid measurements but can be affected by isomeric contributions, fragmentation, and other ion-chemistry interferences, whereas gas chromatography (GC) provides molecular separation and specificity at lower temporal resolution. Here, we present a compact, low-power VOC measurement system that combines in-situ gas chromatography and thermal desorption (TD) preconcentration with a newly developed ultracompact proton-transfer-reaction time-of-flight mass spectrometer (PTR-TOF-MS) equipped with a novel vacuum-ultraviolet (VUV) ion source. The complete system occupies a 50 x 65 x 55 cm space, weighs < 70 kg, and consumes < 600 W of power during typical operation. The instrument combines high-time resolution, direct PTR measurements with periodic chromatographic measurements for regular molecular speciation. The system was operated continuously for 30 days in Thun, Switzerland with stable calibrant response (average variation of 3.5 %) during the ambient measurement period, with demonstrated direct-PTR limits of detection (LODs) of 13 – 136 ppt (1-min) and GC-PTR LODs of 0.1 – 4.0 ppt (1 L sample) across 11 calibrants. Together, these results demonstrate a complementary approach to instrument miniaturization in which reduced detector performance can be offset by upstream analytical separation and preconcentration. In this configuration, the direct PTR measurement provides high-time resolution observations, while periodic chromatographic measurements provide molecular specificity, sensitivity enhancement, and information on analyte-specific ion chemistry and interferences. By reducing the size, power requirements, and operational complexity, this system provides a pathway toward broader deployment of chemically specific VOC measurements at long-term monitoring sites, on mobile platforms, and in locations where infrastructure or reliable power is limited, to investigate emission sources, atmospheric processing, and the formation of secondary pollutants.

  • Open Access

    Photochemical Impacts from Resolving Isomers and Interference Biases in PTR-ToF-MS Measurements of Atmospheric VOCs

    by Xin Feng, Lirong Hui, Yi Chen, Penggang Zheng, Megan S. Claflin, Brian M. Lerner, Yao Chen, Jiali Zhong, Dasa Gu, Yang Xu, et al.

    While proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS) is widely used for ambient volatile organic compounds (VOCs) quantification, its accuracy is limited by isomeric speciation and ionization byproducts. Here, gas chromatography (GC) coupled with PTR-ToF-MS was deployed at a suburban site in Hong Kong to resolve isomers and quantify interferences for ambient VOCs measurement. We identified 48 compounds using GC-PTR and resolved their isomer profiles in direct-PTR data. Our analysis revealed that direct-PTR measurements substantially underestimated long-chain aldehydes (C5–C8) due to extensive fragmentation, while overestimating isoprene, benzene, styrene, and phenol by ∼14–60% because of interference from other species. The biogenic VOCs’ OH reactivity was overestimated by up to 31% for monoterpenes and 241% for isoprene, depending on the seasonality of biogenic emissions. Propagating these biases into the photochemical model resulted in a 46% overestimation in daytime net O3 production under VOC-limited and low-isoprene conditions, whereas the overestimation decreased to 19% under VOC-saturated, high-isoprene conditions. Correcting isomer distributions and interference effects reduced modeled ozone production rates and altered precursor sensitivities, revealing a larger role for oxygenated VOCs in ozone formation than previously recognized. Our results highlight the necessity for isomer-resolved measurements and interference-aware calibration to improve VOC-based assessments of photochemical air pollution.

  • Open Access

    Impact of the chirality on the formation of organic condensable vapors and particle formation from monoterpenes oxidation

    by Matthieu Riva, Linyu Gao, Sébastien Perrier, Siddharth Iyer, Laurent Vanoye, Fabienne Fache, Megan Claflin, Theo Kurtén

    The majority of atmospheric fine particulate matter (PM₂.₅) by mass is typically organic, predominantly composed of secondary organic aerosol (SOA). SOA forms through the gas-phase oxidation of volatile organic compounds (VOCs), followed by the gas-to-particle conversion of oxidized products. Among these precursors, biogenic VOCs (BVOCs), such as isoprene and monoterpenes, are the most abundant, particularly in regions with dense vegetation. For instance, in boreal forests, α-pinene significantly contributes to SOA formation, primarily through the generation of highly oxygenated molecules (HOMs). These low-volatility compounds play a critical role in atmospheric new particle formation. Chirality, a fundamental molecular property, holds profound implications across chemistry, biology, and environmental sciences. While enantiomers exhibit identical physical and chemical properties under most conditions, they can interact distinctly with biological systems—a phenomenon known as enantioselectivity. In atmospheric chemistry, chirality introduces an additional layer of complexity, influencing VOC emissions, oxidation pathways, and the formation and composition of SOA. Despite the ubiquity of chiral VOCs in the atmosphere, their role in aerosol formation and potential health impacts remains poorly understood. This gap is partly due to the analytical challenges of distinguishing enantiomers in both gas and particle phases. Most monoterpenes have been studied without considering the impact of their specific enantiomeric structures. However, certain sources, such as anthropogenic emissions (e.g., limonene) or drought-stressed vegetation (e.g., α-pinene), release specific enantiomers into the atmosphere. Consequently, the formation of SOA from the oxidation of (+)- and (–)-enantiomers has been largely overlooked in experimental studies and atmospheric models. In this study, we investigated the O₃/OH-initiated oxidation of two common chiral monoterpenes ((+)- and (–)-limonene and (+)- and (–)-α-pinene) using a flow tube reactor and an atmospheric simulation chamber. We characterized gaseous and particle-phase products using online chemical ionization mass spectrometry. Our findings reveal that the chirality of the precursors (+)- vs. (–)-enantiomers significantly influences HOM formation, particle formation, and subsequent SOA aging. Overall, this work highlights the distinct particle formation potentials arising from the oxidation of chiral monoterpenes, offering novel insights into the formation of biogenic SOA.

  • Open Access

    Resolving Isomer and Interference Biases in PTR-ToF-MS Measurements of Atmospheric VOCs and Photochemical Impacts

    by Xin Feng, Lirong Hui, Yi Chen, Penggang Zheng, Yao Chen, Jiali Zhong, Yang Xu, Megan Clafin, Brian Lerner, Zhe Wang

    While proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS) is widely used for ambient volatile organic compounds (VOCs) quantification, its accuracy is limited by isobaric interferences, fragmentation, and ionization byproducts. Here, a thermal desorption preconcentration gas chromatography (GC) coupled with Vocus PTR-ToF-MS was deployed at a suburban site in Hong Kong to resolve isomers and quantify interferences for ambient VOCs measurement. We identified and quantified 48 compounds using GC-PTR measurements and resolved their isomer profiles in real-time PTR data based on GC-derived fractions. Our analysis revealed that real-time (RT) PTR measurements substantially underestimate long-chain aldehydes (e.g., C5–C8 aldehydes) due to extensive fragmentation, while overestimating isoprene, benzene, styrene, and phenol by 14-60% because of interference from other species. These biases propagate into photochemical modeling, leading to overestimation of daytime ozone production by ~40% and of biogenic VOCs’ OH reactivity. Correcting isomer distributions and interference effects reduces modeled ozone production rates and alters precursor sensitivities, revealing a larger role for oxygenated VOCs in ozone formation than previously recognized. Our results highlight the necessity for isomer-resolved measurements and interference-aware calibration to improve VOC-based assessments of photochemical air pollution.

  • Open Access

    Introducing a compact GC-PTR-TOF-MS: A novel method for the long-term monitoring of volatile organic compounds

    by Megan Claflin, Urs Rohner, Vasyl Yatsyna, Brian Lerner, Augie Dobrecevich, Joel Thornton, Manjula Canagarantna, Felipe Lopez-Hilfiker, John Jayne

    Long-term, routine monitoring of volatile organic compounds (VOCs) is needed to provide insight into emission sources and patterns, oxidation processes including photochemistry and radical cycling, and the formation of tropospheric ozone and secondary organic aerosol. However, instrumentation that can provide high quality data both in terms of temporal resolution and molecular speciation has historically been cost-prohibitive, and requires advanced users for field deployment, operation, and data analysis.While the use of proton transfer reaction mass spectrometry, paired with time-of-flight technology (PTR-TOF-MS), has been utilized for the detection of VOCs in a wide variety of environments and measurement platforms; this technique cannot provide molecular structure information and suffers from detection interferences such as fragmentation, cluster formation, and mixed ionization schemes that complicate data analysis and interpretation. Combining in situ gas chromatography (GC) with PTR-TOF-MS is a remedy, offering isomer level resolution and the ability to easily quantify product ion distributions to account for complex detection schemes. The addition of chromatographic pre-separation not only enhances the accuracy of species typically reported by PTR methods, it can also be used to broaden the scope of VOCs quantified using PTR methods, while maintaining low limits of detection (typically 1 ppt) without losing high time resolution data and negating the need for high mass resolving power.Here, we present a new instrument package for the online, long-term detection of VOCs consisting of an in situ GC system equipped with an integrated thermal desorption (TD) system coupled to a compact PTR TOF-MS. The entire instrument is contained in a 50 x 65 x 55 cm footprint, weighs < 70 kg, and consumes < 600 W for typical operation. Coupling the GC system with the PTR-TOF allows the automated acquisition of both direct, high-time resolution data (e.g. 1 s) and pseudo-continuous molecular speciation data for isomer separation and improved quantification of the direct-PTR data.A description of the instrument, including its utilization of a new VUV PTR ion source, will be presented along with > 4 weeks of continuous ambient data acquired in Spring 2025 in Thun, Switzerland. This data demonstrates the stability of the system and the value of continuous VOC detection with regular molecular speciation. This compact, easier to operate and maintain system makes it feasible to deploy this technology in many locations, including those with access limitations, for greater spatial resolution to acquire coinciding datasets to elucidate local, regional, and global VOC trends. The compact chemical ionization time-of-flight mass spectrometer (CI-TOF-MS) described, here utilizing proton transfer reaction (PTR) ionization, was developed with support from the Beckmann Foundation.

  • Open Access

    Total cancer risk estimates from measured concentrations of volatile organic compounds in industrialized southeastern Louisiana

    by Ellis S. Robinson, Amira Yassine, Shivang Agarwal, Mina W. Tehrani, Sara N. Lupolt, Andrea A. Chiger, Carolyn Gigot, Megan S. Claflin, Brian M. Lerner, Tara I. Yacovitch, et al.

    Communities in southeastern Louisiana are subject to disproportionate environmental health burdens, including elevated risk for cancer, from emissions of industrial hazardous air pollutants (HAPs). However, there are few ambient measurements (or none) of various HAPs in the heavily industrialized corridor between Baton Rouge and New Orleans (BR-NO). We measured 17 carcinogenic volatile organic compounds using fast-response in situ instrumentation aboard a mobile laboratory. Using spatially resolved concentrations, we estimate cancer risk in 15 census tracts along an 81 km-long stretch of the BR-NO corridor. In 14 of 15 tracts, our estimates of total cancer risk were higher (range: 0.9 to 11.6 × ; median: 5 × ) than those from the U.S. Environmental Protection Agency’s (USEPA) 2020 Air Toxics Screening Assessment (AirToxScreen). Our maximum estimate for total tract-level cancer risk was 560-in-one million excess cancer cases, far exceeding the upper limit of USEPA’s acceptable risk range (100-in-one million). This discrepancy is largely explained by differences between measured vs. modeled ethylene oxide concentrations, though there are important contributions from a number of additional HAPs. Our risk estimates are dominated by ethylene oxide, which contributes between 39.5 and 92.2% of total cancer risk across all tracts; chloroprene (0.2 to 36.8%); and formaldehyde (4.1 to 14.6%). AirToxScreen also identifies these three compounds as primary drivers of risk in this location. Together, these three compounds account for between 63 and 96.9% of total cancer risk. There is substantial spatial variability in total cancer risk and the relative contribution of each HAP, both between and within tracts. These data substantiate claims that the region has high HAPs-related cancer risk and quantify which individual HAPs are of highest concern.