Klaus Lips
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Klaus Lips has a total of 212 co-authors. Here are the top co-authors by number of shared publications:
- Rowan W. MacQueen
Helmholtz-Zentrum Berlin für Materialien und Energie GmbH Hahn-Meitner-Platz 1 14109 Berlin Germany
7 shared publications - Jens Anders
University of Stuttgart
6 shared publications - Jan Behrends
Fachbereich Physik, Freie Universität Berlin, Berlin, Germany
5 shared publications - Joseph E. McPeak
University of Copenhagen
5 shared publications - Boris Naydenov
Helmholtz-Zentrum Berlin für Materialien und Energie
4 shared publications Clemens Gersmann
Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, 14109 Berlin, Germany
4 shared publications
Latest Publications
- 27 September 2026
- Published by American Chemical Society (ACS) in ACS Energy Letters
- Vol. 11 (10) , 6590-6597
Enhanced Operational Stability in Tin-Based Perovskite Solar Cells via a Natural Antioxidant
In tin-based perovskite solar cells (TPSCs), Sn(II) oxidation and illumination-induced lattice instability are primary drivers of device degradation. In this study, we introduce ellagic acid (EA), a natural antioxidant, into DMSO-free fabricated tin perovskites. Computational simulations show that EA stabilizes formamidinium sites within the perovskite lattice and effectively inhibits Sn(II) oxidation. Besides, this incorporation greatly improves film homogeneity and passivates defect traps, increasing the champion power conversion efficiency from 9.3 to 10.2%. Consequently, unencapsulated EA-incorporated devices exhibit a sixfold increase in T80 lifetime (in a nitrogen atmosphere) and a threefold increase in T60 lifetime (in dry air) at the maximum power point tracking under continuous illumination. Moreover, an EA-incorporated device achieves a 16% increment over 1000 h of day/night cycling, significantly outperforming the 7% rise of the control. These results demonstrate that natural antioxidants are a highly effective and sustainable strategy for enhancing the operational stability of lead-free TPSCs.
- 27 September 2026
- Published by American Chemical Society (ACS) in ACS Energy Letters
- Vol. 11 (10) , 6590-6597
Enhanced Operational Stability in Tin-Based Perovskite Solar Cells via a Natural Antioxidant
In tin-based perovskite solar cells (TPSCs), Sn(II) oxidation and illumination-induced lattice instability are primary drivers of device degradation. In this study, we introduce ellagic acid (EA), a natural antioxidant, into DMSO-free fabricated tin perovskites. Computational simulations show that EA stabilizes formamidinium sites within the perovskite lattice and effectively inhibits Sn(II) oxidation. Besides, this incorporation greatly improves film homogeneity and passivates defect traps, increasing the champion power conversion efficiency from 9.3 to 10.2%. Consequently, unencapsulated EA-incorporated devices exhibit a sixfold increase in T80 lifetime (in a nitrogen atmosphere) and a threefold increase in T60 lifetime (in dry air) at the maximum power point tracking under continuous illumination. Moreover, an EA-incorporated device achieves a 16% increment over 1000 h of day/night cycling, significantly outperforming the 7% rise of the control. These results demonstrate that natural antioxidants are a highly effective and sustainable strategy for enhancing the operational stability of lead-free TPSCs.
- Open Access
- 18 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (38)
Concurrent excitation and detection in magnetic resonance using voltage-controlled oscillators
Dead time following radio frequency excitation limits pulsed magnetic resonance (MR) experiments by obscuring early-time spin dynamics and short-lived signals. We demonstrate continuous concurrent excitation and detection using two oscillator-based MR detectors: a high-frequency (477 megahertz) injection-locked voltage-controlled oscillator (VCO) array enabling a scalable segmented-coil architecture and a low-frequency (17 megahertz) single-coil VCO. Both detectors are embedded in custom-designed phase-locked loops, enabling phase-coherent multipulse operation. Using a planar segmented coil driven by a chip-integrated VCO array operating at 477-megahertz proton frequency, we perform conventional Fourier transform nuclear MR, continuously monitor driven Rabi oscillations throughout the excitation pulse, and observe the immediate onset of free-induction decay, all without dedicated transmit-receive switches or receiver gating. We further demonstrate phase-coherent, phase-cycled multipulse operation, including a Hahn echo sequence realized on a second system operating at 17 megahertz. Together, these results demonstrate the general applicability and versatility of the oscillator-based detection principle across pulse sequences and operating frequencies.
- 18 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (38)
Open AccessConcurrent excitation and detection in magnetic resonance using voltage-controlled oscillators
Dead time following radio frequency excitation limits pulsed magnetic resonance (MR) experiments by obscuring early-time spin dynamics and short-lived signals. We demonstrate continuous concurrent excitation and detection using two oscillator-based MR detectors: a high-frequency (477 megahertz) injection-locked voltage-controlled oscillator (VCO) array enabling a scalable segmented-coil architecture and a low-frequency (17 megahertz) single-coil VCO. Both detectors are embedded in custom-designed phase-locked loops, enabling phase-coherent multipulse operation. Using a planar segmented coil driven by a chip-integrated VCO array operating at 477-megahertz proton frequency, we perform conventional Fourier transform nuclear MR, continuously monitor driven Rabi oscillations throughout the excitation pulse, and observe the immediate onset of free-induction decay, all without dedicated transmit-receive switches or receiver gating. We further demonstrate phase-coherent, phase-cycled multipulse operation, including a Hahn echo sequence realized on a second system operating at 17 megahertz. Together, these results demonstrate the general applicability and versatility of the oscillator-based detection principle across pulse sequences and operating frequencies.
- Open Access
- 26 September 2024
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (10) , 5099-5108
Compact Electron Paramagnetic Resonance on a Chip Spectrometer Using a Single Sided Permanent Magnet
Electron paramagnetic resonance (EPR) spectroscopy provides information about the physical and chemical properties of materials by detecting paramagnetic states. Conventional EPR measurements are performed in high Q resonator using large electromagnets which limits the available space for operando experiments. Here we present a solution toward a portable EPR sensor based on the combination of the EPR-on-a-Chip (EPRoC) and a single-sided permanent magnet. This device can be placed directly into the sample environment (i.e., catalytic reaction vessels, ultrahigh vacuum deposition chambers, aqueous environments, etc.) to conduct in situ and operando measurements. The EPRoC reported herein is comprised of an array of 14 voltage-controlled oscillator (VCO) coils oscillating at 7 GHz. By using a single grain of crystalline BDPA, EPR measurements at different positions of the magnet with respect to the VCO array were performed. It was possible to create a 2D spatial map of a 1.5 mm × 5 mm region of the magnetic field with 50 μm resolution. This allowed for the determination of the magnetic field intensity and homogeneity, which are found to be 254.69 mT and 700 ppm, respectively. The magnetic field was mapped also along the vertical direction using a thin film a-Si layer. The EPRoC and permanent magnet were combined to form a miniaturized EPR spectrometer to perform experiments on tempol (4-hydroxy-2,2,6,6-teramethylpiperidin-1-oxyl) dissolved in an 80% glycerol and 20% water solution. It was possible to determine the molecular tumbling correlation time and to establish a calibration procedure to quantify the number of spins within the sample.
- 26 September 2024
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (10) , 5099-5108
Open AccessCompact Electron Paramagnetic Resonance on a Chip Spectrometer Using a Single Sided Permanent Magnet
Electron paramagnetic resonance (EPR) spectroscopy provides information about the physical and chemical properties of materials by detecting paramagnetic states. Conventional EPR measurements are performed in high Q resonator using large electromagnets which limits the available space for operando experiments. Here we present a solution toward a portable EPR sensor based on the combination of the EPR-on-a-Chip (EPRoC) and a single-sided permanent magnet. This device can be placed directly into the sample environment (i.e., catalytic reaction vessels, ultrahigh vacuum deposition chambers, aqueous environments, etc.) to conduct in situ and operando measurements. The EPRoC reported herein is comprised of an array of 14 voltage-controlled oscillator (VCO) coils oscillating at 7 GHz. By using a single grain of crystalline BDPA, EPR measurements at different positions of the magnet with respect to the VCO array were performed. It was possible to create a 2D spatial map of a 1.5 mm × 5 mm region of the magnetic field with 50 μm resolution. This allowed for the determination of the magnetic field intensity and homogeneity, which are found to be 254.69 mT and 700 ppm, respectively. The magnetic field was mapped also along the vertical direction using a thin film a-Si layer. The EPRoC and permanent magnet were combined to form a miniaturized EPR spectrometer to perform experiments on tempol (4-hydroxy-2,2,6,6-teramethylpiperidin-1-oxyl) dissolved in an 80% glycerol and 20% water solution. It was possible to determine the molecular tumbling correlation time and to establish a calibration procedure to quantify the number of spins within the sample.
- Open Access
- 16 August 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (33) , eado5467
Microwave field mapping for EPR-on-a-chip experiments
Electron paramagnetic resonance–on-a-chip (EPRoC) devices use small voltage-controlled oscillators (VCOs) for both the excitation and detection of the EPR signal, allowing access to unique sample environments by lifting the restrictions imposed by resonator-based EPR techniques. EPRoC devices have been successfully used at multiple frequencies (7 to 360 gigahertz) and have demonstrated their utility in producing high-resolution spectra in a variety of spin centers. To enable quantitative measurements using EPRoC devices, the spatial distribution of the B 1 field produced by the VCOs must be known. As an example, the field distribution of a 12-coil VCO array EPRoC operating at 14 gigahertz is described in this study. The frequency modulation–recorded EPR spectra of a “point”-like and a thin-film sample were investigated while varying the position of both samples in three directions. The results were compared to COMSOL simulations of the B 1 -field intensity. The EPRoC array sensitive volume was determined to be ~19 nanoliters. Implications for possible EPR applications are discussed.
- 16 August 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (33) , eado5467
Open AccessMicrowave field mapping for EPR-on-a-chip experiments
Electron paramagnetic resonance–on-a-chip (EPRoC) devices use small voltage-controlled oscillators (VCOs) for both the excitation and detection of the EPR signal, allowing access to unique sample environments by lifting the restrictions imposed by resonator-based EPR techniques. EPRoC devices have been successfully used at multiple frequencies (7 to 360 gigahertz) and have demonstrated their utility in producing high-resolution spectra in a variety of spin centers. To enable quantitative measurements using EPRoC devices, the spatial distribution of the B 1 field produced by the VCOs must be known. As an example, the field distribution of a 12-coil VCO array EPRoC operating at 14 gigahertz is described in this study. The frequency modulation–recorded EPR spectra of a “point”-like and a thin-film sample were investigated while varying the position of both samples in three directions. The results were compared to COMSOL simulations of the B 1 -field intensity. The EPRoC array sensitive volume was determined to be ~19 nanoliters. Implications for possible EPR applications are discussed.
- Open Access
- 5 June 2024
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 26 (25) , 17785-17795
Monitoring the state of charge of vanadium redox flow batteries with an EPR-on-a-Chip dipstick sensor
The EPRoC dipstick enables the monitoring of the state of charge in corrosive electrolyte-containing solutions of vanadium redox flow batteries.
- 5 June 2024
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 26 (25) , 17785-17795
Open AccessMonitoring the state of charge of vanadium redox flow batteries with an EPR-on-a-Chip dipstick sensor
The EPRoC dipstick enables the monitoring of the state of charge in corrosive electrolyte-containing solutions of vanadium redox flow batteries.
- Open Access
Room Temperature Microsecond Coherence of Silicon Dangling Bonds
Paramagnetic point defects in silicon provide qubits that could open up pathways towards silicon-technology based, low-cost, room-temperature (RT) quantum sensing. The silicon dangling bond (db) is a natural candidate, given its sub-nanometer localization and direct involvement in spin-dependent charge-carrier recombination, allowing for electrical spin readout. In crystalline silicon, however, rapid loss of db spin-coherence at RT due to free-electron trapping, strongly limits quantum applications. In this work, by combining density-functional theory and multifrequency (100 MHz-263 GHz) pulsed electrically detected magnetic resonance spectroscopy, we show that upon electron capture, dbs in a hydrogenated amorphous silicon matrix form metastable spin pairs in a well-defined quasi two-dimensional (2D) configuration. Although highly localized, these entangled spin pairs exhibit nearly vanishing intrinsic dipolar and exchange coupling. The formation of this magic-angle-like configuration involves a >0.3 eV energy relaxation of a trapped electron, stabilizing the pair. This extends RT spin coherence times into the microsecond range in silicon required for a future spin-based quantum sensing technology.
Open AccessRoom Temperature Microsecond Coherence of Silicon Dangling Bonds
Paramagnetic point defects in silicon provide qubits that could open up pathways towards silicon-technology based, low-cost, room-temperature (RT) quantum sensing. The silicon dangling bond (db) is a natural candidate, given its sub-nanometer localization and direct involvement in spin-dependent charge-carrier recombination, allowing for electrical spin readout. In crystalline silicon, however, rapid loss of db spin-coherence at RT due to free-electron trapping, strongly limits quantum applications. In this work, by combining density-functional theory and multifrequency (100 MHz-263 GHz) pulsed electrically detected magnetic resonance spectroscopy, we show that upon electron capture, dbs in a hydrogenated amorphous silicon matrix form metastable spin pairs in a well-defined quasi two-dimensional (2D) configuration. Although highly localized, these entangled spin pairs exhibit nearly vanishing intrinsic dipolar and exchange coupling. The formation of this magic-angle-like configuration involves a >0.3 eV energy relaxation of a trapped electron, stabilizing the pair. This extends RT spin coherence times into the microsecond range in silicon required for a future spin-based quantum sensing technology.
- Open Access
Long-Term Characterization of Oxidation Processes in Graphitic Carbon Nitride Photocatalyst Materials via Electron Paramagnetic Resonance Spectroscopy
Graphitic carbon nitride (gCN) materials have been shown to efficiently perform light-induced water splitting, carbon dioxide reduction, and environmental remediation in a cost-effective way. However, gCN suffers from rapid charge-carrier recombination, inefficient light absorption, and poor long-term stability which greatly hinders photocatalytic performance. To determine the underlying catalytic mechanisms and overall contributions that will improve performance, the electronic structure of gCN materials has been investigated using electron paramagnetic resonance (EPR) spectroscopy. Through lineshape analysis and relaxation behavior, evidence of two independent spin species were determined to be present in catalytically active gCN materials. These two contributions to the total lineshape respond independently to light exposure such that the previously established catalytically active spin system remains responsive while the newly observed, superimposed EPR signal is not increased during exposure to light. The time dependence of these two peaks present in gCN EPR spectra recorded sequentially in air over several months demonstrates a steady change in the electronic structure of the gCN framework over time. This light-independent, slowly evolving additional spin center is demonstrated to be the result of oxidative processes occurring as a result of exposure to the environment and is confirmed by forced oxidation experiments. This oxidized gCN exhibits lower H2 production rates and indicates quenching of the overall gCN catalytic activity over longer reaction times. A general model for the newly generated spin centers is given and strategies for the alleviation of oxidative products within the gCN framework are discussed in the context of improving photocatalytic activity over extended durations as required for future functional photocatalytic device development.
Open AccessLong-Term Characterization of Oxidation Processes in Graphitic Carbon Nitride Photocatalyst Materials via Electron Paramagnetic Resonance Spectroscopy
Graphitic carbon nitride (gCN) materials have been shown to efficiently perform light-induced water splitting, carbon dioxide reduction, and environmental remediation in a cost-effective way. However, gCN suffers from rapid charge-carrier recombination, inefficient light absorption, and poor long-term stability which greatly hinders photocatalytic performance. To determine the underlying catalytic mechanisms and overall contributions that will improve performance, the electronic structure of gCN materials has been investigated using electron paramagnetic resonance (EPR) spectroscopy. Through lineshape analysis and relaxation behavior, evidence of two independent spin species were determined to be present in catalytically active gCN materials. These two contributions to the total lineshape respond independently to light exposure such that the previously established catalytically active spin system remains responsive while the newly observed, superimposed EPR signal is not increased during exposure to light. The time dependence of these two peaks present in gCN EPR spectra recorded sequentially in air over several months demonstrates a steady change in the electronic structure of the gCN framework over time. This light-independent, slowly evolving additional spin center is demonstrated to be the result of oxidative processes occurring as a result of exposure to the environment and is confirmed by forced oxidation experiments. This oxidized gCN exhibits lower H2 production rates and indicates quenching of the overall gCN catalytic activity over longer reaction times. A general model for the newly generated spin centers is given and strategies for the alleviation of oxidative products within the gCN framework are discussed in the context of improving photocatalytic activity over extended durations as required for future functional photocatalytic device development.
- Open Access
- 15 July 2023
- Published by MDPI AG in Magnetochemistry
- Vol. 9 (7) , 183
Electrically Detected Magnetic Resonance on a Chip (EDMRoC) for Analysis of Thin-Film Silicon Photovoltaics
Electrically detected magnetic resonance (EDMR) is a spectroscopic technique that provides information about the physical properties of materials through the detection of variations in conductivity induced by spin-dependent processes. EDMR has been widely applied to investigate thin-film semiconductor materials in which the presence of defects can induce the current limiting processes. Conventional EDMR measurements are performed on samples with a special geometry that allows the use of a typical electron paramagnetic resonance (EPR) resonator. For such measurements, it is of utmost importance that the geometry of the sample under assessment does not influence the results of the experiment. Here, we present a single-board EPR spectrometer using a chip-integrated, voltage-controlled oscillator (VCO) array as a planar microwave source, whose geometry optimally matches that of a standard EDMR sample, and which greatly facilitates electrical interfacing to the device under assessment. The probehead combined an ultrasensitive transimpedance amplifier (TIA) with a twelve-coil array, VCO-based, single-board EPR spectrometer to permit EDMR-on-a-Chip (EDMRoC) investigations. EDMRoC measurements were performed at room temperature on a thin-film hydrogenated amorphous silicon (a-Si:H) pin solar cell under dark and forward bias conditions, and the recombination current driven by the a-Si:H dangling bonds (db) was detected. These experiments serve as a proof of concept for a new generation of small and versatile spectrometers that allow in situ and operando EDMR experiments.
- 15 July 2023
- Published by MDPI AG in Magnetochemistry
- Vol. 9 (7) , 183
Open AccessElectrically Detected Magnetic Resonance on a Chip (EDMRoC) for Analysis of Thin-Film Silicon Photovoltaics
Electrically detected magnetic resonance (EDMR) is a spectroscopic technique that provides information about the physical properties of materials through the detection of variations in conductivity induced by spin-dependent processes. EDMR has been widely applied to investigate thin-film semiconductor materials in which the presence of defects can induce the current limiting processes. Conventional EDMR measurements are performed on samples with a special geometry that allows the use of a typical electron paramagnetic resonance (EPR) resonator. For such measurements, it is of utmost importance that the geometry of the sample under assessment does not influence the results of the experiment. Here, we present a single-board EPR spectrometer using a chip-integrated, voltage-controlled oscillator (VCO) array as a planar microwave source, whose geometry optimally matches that of a standard EDMR sample, and which greatly facilitates electrical interfacing to the device under assessment. The probehead combined an ultrasensitive transimpedance amplifier (TIA) with a twelve-coil array, VCO-based, single-board EPR spectrometer to permit EDMR-on-a-Chip (EDMRoC) investigations. EDMRoC measurements were performed at room temperature on a thin-film hydrogenated amorphous silicon (a-Si:H) pin solar cell under dark and forward bias conditions, and the recombination current driven by the a-Si:H dangling bonds (db) was detected. These experiments serve as a proof of concept for a new generation of small and versatile spectrometers that allow in situ and operando EDMR experiments.
- Open Access
- 27 July 2021
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 2 (19) , 6297-6305
High-field/high-frequency EPR spectroscopy on synthetic melanin: on the origin of carbon-centered radicals
Among all the pigments found in nature, melanin has drawn considerable attention for bioelectronics applications as it contains a set of physicochemical properties such as antioxidant activity, metal chelation, biocompatibility, broad-band absorbance throughout the UV-visible region, hydration-dependent conductivity and intrinsic and extrinsic free radical character. A better understanding of these properties is a matter of significant importance to improve melanin-based organic devices efficiently. Therefore, the origin of melanin free-radicals was studied using continuous-wave electron paramagnetic resonance (EPR) spectroscopy at 263 GHz for standard non-functionalized and sulfonated derivatives. Our results indicated that more than one radical species should be evoked to study the free-radical nature of standard and sulfonated melanin. Additionally, we also confirm that the free-radical system of sulfonated melanin is similar to non-functionalized melanin. Based on the g-anisotropy analysis, we propose which potential units could be responsible for carbon-centered radicals.
- 27 July 2021
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 2 (19) , 6297-6305
Open AccessHigh-field/high-frequency EPR spectroscopy on synthetic melanin: on the origin of carbon-centered radicals
Among all the pigments found in nature, melanin has drawn considerable attention for bioelectronics applications as it contains a set of physicochemical properties such as antioxidant activity, metal chelation, biocompatibility, broad-band absorbance throughout the UV-visible region, hydration-dependent conductivity and intrinsic and extrinsic free radical character. A better understanding of these properties is a matter of significant importance to improve melanin-based organic devices efficiently. Therefore, the origin of melanin free-radicals was studied using continuous-wave electron paramagnetic resonance (EPR) spectroscopy at 263 GHz for standard non-functionalized and sulfonated derivatives. Our results indicated that more than one radical species should be evoked to study the free-radical nature of standard and sulfonated melanin. Additionally, we also confirm that the free-radical system of sulfonated melanin is similar to non-functionalized melanin. Based on the g-anisotropy analysis, we propose which potential units could be responsible for carbon-centered radicals.
- Open Access
- 23 June 2021
- Published by Copernicus GmbH
- p. 1-19
Comment on mr-2021-42
In this paper, we present an in-depth analysis of a voltage-controlled oscillator (VCO) based sensing method for electron spin resonance (ESR) spectroscopy, which greatly simplifies the experimental setup compared to conventional detection schemes. In contrast to our previous oscillator-based ESR detectors, where the ESR signal was encoded in the oscillation frequency, in the amplitude-sensitive method, the ESR signal is sensed as a change of the oscillation amplitude of the VCO. Therefore, using a VCO architecture with a built-in amplitude demodulation scheme, the experimental setup reduces to a single permanent magnet in combination with a few inexpensive electronic components. We present a theoretical analysis of the achievable limit of detection, which uses a perturbation theory based VCO-modeling for the signal and applies a stochastic averaging approach to obtain a closed-form expression for the noise floor. Additionally, the paper also introduces a numerical model suitable for simulating oscillator-based ESR experiments in a conventional circuit simulator environment. This model can, e.g., be used to optimize sensor performance early on in the design phase. Finally, all presented models are verified against measured results from a prototype VCO operating at 14 GHz inside a 0.5 T magnetic field.
- 23 June 2021
- Published by Copernicus GmbH
- p. 1-19
Open AccessComment on mr-2021-42
In this paper, we present an in-depth analysis of a voltage-controlled oscillator (VCO) based sensing method for electron spin resonance (ESR) spectroscopy, which greatly simplifies the experimental setup compared to conventional detection schemes. In contrast to our previous oscillator-based ESR detectors, where the ESR signal was encoded in the oscillation frequency, in the amplitude-sensitive method, the ESR signal is sensed as a change of the oscillation amplitude of the VCO. Therefore, using a VCO architecture with a built-in amplitude demodulation scheme, the experimental setup reduces to a single permanent magnet in combination with a few inexpensive electronic components. We present a theoretical analysis of the achievable limit of detection, which uses a perturbation theory based VCO-modeling for the signal and applies a stochastic averaging approach to obtain a closed-form expression for the noise floor. Additionally, the paper also introduces a numerical model suitable for simulating oscillator-based ESR experiments in a conventional circuit simulator environment. This model can, e.g., be used to optimize sensor performance early on in the design phase. Finally, all presented models are verified against measured results from a prototype VCO operating at 14 GHz inside a 0.5 T magnetic field.