Luiza Braga Ferreira dos Santos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Luiza Braga Ferreira dos Santos has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Carlos Nelson Elias
5 shared publicationsFrancielly Moura de Souza Soares
4 shared publicationsEmília dos Santos Monteiro
3 shared publicationsAna Isabel de Carvalho Santana
2 shared publicationsMaria Elisa Rodrigues Coimbra
2 shared publicationsPaula Anastácia Moraes Cairo Gomes
2 shared publications
Latest Publications
- Open Access
- 16 February 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (2) , 355-362
Grazing-incidence synchrotron radiation diffraction studies on irradiated Ce-doped and pristine Y-stabilized ZrO2 at the Rossendorf beamline
In this work, Ce-doped yttria-stabilized zirconia (YSZ) and pure YSZ phases were subjected to irradiation with 14 MeV Au ions. Irradiation studies were performed to simulate long-term structural and microstructural damage due to self-irradiation in YSZ phases hosting alpha-active radioactive species. It was found that both the Ce-doped YSZ and the YSZ phases had a reasonable tolerance to irradiation at high ion fluences and the bulk crystallinity was well preserved. Nevertheless, local microstrain increased in all compounds under study after irradiation, with the Ce-doped phases being less affected than pure YSZ. Doping with cerium ions increased the microstructural stability of YSZ phases through a possible reduction in the mobility of oxygen atoms, which limits the formation of structural defects. Doping of YSZ with tetravalent actinide elements is expected to have a similar effect. Thus, YSZ phases are promising for the safe long-term storage of radioactive elements. Using synchrotron radiation diffraction, measurements of the thin irradiated layers of the Ce-YSZ and YSZ samples were performed in grazing incidence (GI) mode. A corresponding module for measurements in GI mode was developed at the Rossendorf Beamline and relevant technical details for sample alignment and data collection are also presented.
- 16 February 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (2) , 355-362
Open AccessGrazing-incidence synchrotron radiation diffraction studies on irradiated Ce-doped and pristine Y-stabilized ZrO2 at the Rossendorf beamline
In this work, Ce-doped yttria-stabilized zirconia (YSZ) and pure YSZ phases were subjected to irradiation with 14 MeV Au ions. Irradiation studies were performed to simulate long-term structural and microstructural damage due to self-irradiation in YSZ phases hosting alpha-active radioactive species. It was found that both the Ce-doped YSZ and the YSZ phases had a reasonable tolerance to irradiation at high ion fluences and the bulk crystallinity was well preserved. Nevertheless, local microstrain increased in all compounds under study after irradiation, with the Ce-doped phases being less affected than pure YSZ. Doping with cerium ions increased the microstructural stability of YSZ phases through a possible reduction in the mobility of oxygen atoms, which limits the formation of structural defects. Doping of YSZ with tetravalent actinide elements is expected to have a similar effect. Thus, YSZ phases are promising for the safe long-term storage of radioactive elements. Using synchrotron radiation diffraction, measurements of the thin irradiated layers of the Ce-YSZ and YSZ samples were performed in grazing incidence (GI) mode. A corresponding module for measurements in GI mode was developed at the Rossendorf Beamline and relevant technical details for sample alignment and data collection are also presented.
- Open Access
- 20 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-10
Nanosized hydroxyapatite and β-tricalcium phosphate composite: Physico-chemical, cytotoxicity, morphological properties and in vivo trial
The objective of this work was to characterize the properties of a synthetic biomaterial composite with nanoparticles size (Blue Bone). This biomaterial is a composite recommended for dental and orthopedic grafting surgery, for guided bone regeneration, including maxillary sinus lift, fresh alveolus filling, and treatment of furcation lesions. The nano biomaterials surface area is from 30% to 50% higher than those with micro dimensions. Another advantage is that the alloplastic biomaterial has homogeneous properties due to the complete manufacturing control. The analyzed biomaterial composite was characterized by XRD, cytochemistry, scanning electron microscopy, porosimetry and in vivo experiments (animals). The results showed that the analyzed biomaterial composite has 78.76% hydroxyapatite [Ca5(PO4)3(OH)] with monoclinic structure, 21.03% β-tricalcium phosphate [β -Ca3(PO4)2] with trigonal structure and 0.19% of CaO with cubic structure, nanoparticles with homogeneous shapes, and nanoporosity. The in vivo experiments showed that the composite has null cytotoxicity, and the site of insertion biomaterials has a high level of vascularization and bone formation. The conclusion is that the synthetic biomaterial with Blue Bone designation presents characteristics suitable for use in grafting surgery applications.
- 20 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-10
Open AccessNanosized hydroxyapatite and β-tricalcium phosphate composite: Physico-chemical, cytotoxicity, morphological properties and in vivo trial
The objective of this work was to characterize the properties of a synthetic biomaterial composite with nanoparticles size (Blue Bone). This biomaterial is a composite recommended for dental and orthopedic grafting surgery, for guided bone regeneration, including maxillary sinus lift, fresh alveolus filling, and treatment of furcation lesions. The nano biomaterials surface area is from 30% to 50% higher than those with micro dimensions. Another advantage is that the alloplastic biomaterial has homogeneous properties due to the complete manufacturing control. The analyzed biomaterial composite was characterized by XRD, cytochemistry, scanning electron microscopy, porosimetry and in vivo experiments (animals). The results showed that the analyzed biomaterial composite has 78.76% hydroxyapatite [Ca5(PO4)3(OH)] with monoclinic structure, 21.03% β-tricalcium phosphate [β -Ca3(PO4)2] with trigonal structure and 0.19% of CaO with cubic structure, nanoparticles with homogeneous shapes, and nanoporosity. The in vivo experiments showed that the composite has null cytotoxicity, and the site of insertion biomaterials has a high level of vascularization and bone formation. The conclusion is that the synthetic biomaterial with Blue Bone designation presents characteristics suitable for use in grafting surgery applications.
- 1 February 2019
- Published by Editora Edgard Blucher, Ltda.
ANÁLISE DA MICRODUREZA E MICROESTRUTURA DAS LIGAS TI ULTRA FINE GRAINED E TI-6AL-4V
- 1 February 2019
- Published by Editora Edgard Blucher, Ltda.
ANÁLISE DA MICRODUREZA E MICROESTRUTURA DAS LIGAS TI ULTRA FINE GRAINED E TI-6AL-4V
- 1 February 2019
- Published by Editora Edgard Blucher, Ltda.
- p. 3091-3099
ESTUDO COMPARATIVO DAS TÉCNICAS DE DEGRADAÇÃO DA SUPERFÍCIE DO POLITETRAFLÚORETILENO
- 1 February 2019
- Published by Editora Edgard Blucher, Ltda.
- p. 3091-3099
ESTUDO COMPARATIVO DAS TÉCNICAS DE DEGRADAÇÃO DA SUPERFÍCIE DO POLITETRAFLÚORETILENO
- Open Access
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 22 (suppl 1)
Influence of oral pH Environment in the Corrosion Resistance of Cr-Co-Mo alloy Used for Dentistry Prosthetic Components
The Cr-Co-Mo alloys are commonly used in dentistry for prosthetic components and dental implant supported prosthesis. These alloys present high corrosion resistance owing to a passive oxide film on the surface. However, the oral environment is an aggressive system, due to pH variation, chloride and fluoride ions presence, that can decrease the metal alloy corrosion resistance. Although Cr-Co-Mo alloys have been used for a long time, their electrochemical properties on different pH have not been studied yet. This study aimed to evaluate the electrochemical properties of Cr-Co-Mo alloy in NaCl 0.9% solution in different pH and mouthwash solution. To imitate the oral environment, electrolytes with a pH equal to 2, 3, and 6 were used. Corrosion studies were performed by open circuit potential observation, potentiodynamic polarization curve, chronoamperometry and electrochemical impedance. The results showed that the analyzed alloy has good corrosion resistance under experimental conditions, although the acidified NaCl 0.9% solution increased the corrosion current, particularly in cathodic potentials.
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 22 (suppl 1)
Open AccessInfluence of oral pH Environment in the Corrosion Resistance of Cr-Co-Mo alloy Used for Dentistry Prosthetic Components
The Cr-Co-Mo alloys are commonly used in dentistry for prosthetic components and dental implant supported prosthesis. These alloys present high corrosion resistance owing to a passive oxide film on the surface. However, the oral environment is an aggressive system, due to pH variation, chloride and fluoride ions presence, that can decrease the metal alloy corrosion resistance. Although Cr-Co-Mo alloys have been used for a long time, their electrochemical properties on different pH have not been studied yet. This study aimed to evaluate the electrochemical properties of Cr-Co-Mo alloy in NaCl 0.9% solution in different pH and mouthwash solution. To imitate the oral environment, electrolytes with a pH equal to 2, 3, and 6 were used. Corrosion studies were performed by open circuit potential observation, potentiodynamic polarization curve, chronoamperometry and electrochemical impedance. The results showed that the analyzed alloy has good corrosion resistance under experimental conditions, although the acidified NaCl 0.9% solution increased the corrosion current, particularly in cathodic potentials.
- Open Access
- 1 December 2018
- Published by Elsevier in Biomedicine & Pharmacotherapy
- Vol. 108, 1703-1711
Synthesis, in vitro and in vivo anti-Trypanosoma cruzi and toxicological activities of nitroaromatic Schiff bases
- 1 December 2018
- Published by Elsevier in Biomedicine & Pharmacotherapy
- Vol. 108, 1703-1711
Open AccessSynthesis, in vitro and in vivo anti-Trypanosoma cruzi and toxicological activities of nitroaromatic Schiff bases