LCLinyu Chen

Linyu Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Linyu Chen has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Terahertz computed tomography of high-refractive-index object based on a novel experimental procedure

    by Linyu Chen, Yuye Wang, Degang Xu, Jia Shi, Yuchen Ren, Changzhao Li, Chao Zhang, Longhuang Tang, Yixin He, Jianquan Yao

    Recently, terahertz (THz) computed tomography (CT) has emerged as a possible effective technique for 3D structural information detection. However, THz-CT is difficult to be applied to high refractive index object, due to the severe refraction phenomenon occurred during the acquisition of raw data. We propose a novel experimental procedure to solve this problem. Including the use of a sink filled with liquid whose refractive index is close to the sample, and a correction algorithm to eliminate the noise of liquid. The proposed method is applied to the high-density polyethylene samples of different shapes.

  • Open Access

    Terahertz Computed Tomography of High-Refractive-Index Objects Based on Refractive Index Matching

    by Linyu Chen, Yuye Wang, Degang Xu, Yuchen Ren, Yixin He, Changzhao Li, Chao Zhang, Longhuang Tang, Chao Yan, Jianquan Yao

    Terahertz (THz) computed tomography (CT) is a promising technique to obtain the internal information of objects due to its properties of nonionizing and high penetration of nonpolar objects. However, THz CT is hindered by the strong refractive effect and Fresnel reflection loss when it is applied to high-refractive-index samples. In this paper, the three-dimensional image of the sample is performed in the low absorption liquid, the refractive index of which is close to the sample. This novel experimental procedure can eliminate the refractive effect and Fresnel reflection loss effectively. Together with the data processing to eliminate the liquid absorption and to restrain the artifacts, the THz CT imaging of high-density polyethylene ( n = 1.53) cylinders and cubes is achieved successfully. The internal hole and metallic foreign body are shown accurately. In addition, the defects with different sizes inside the sample are measured with refractive index matching method. It shows that THz CT imaging based on refractive index matching method has high sensitivity to detect the small defect inside the sample as small as 0.5 mm diameter.


  • Interference elimination in terahertz imaging based on inverse image processing

    by Yuye Wang, Linyu Chen, Tunan Chen, Degang Xu, Jia Shi, Yuchen Ren, Changzhao Li, Chao Zhang, Hongxiang Liu, Limin Wu, et al.

    We propose a novel image restoration approach to eliminate the interference fringes in terahertz (THz) imaging. By making use of the information in the background of a THz image, inverse image processing is introduced under a priori knowledge about the degradation mechanism to suppress the interference. Based on a simulated interference image and the original THz image of a piece of paper coated with graphite powder, taken from our continuous THz imaging system, the interference fringes are successfully eliminated. The enhancement of the peak signal-to-noise ratio and structural similarity index is achieved, compared with the frequency domain filtering. Moreover, the inverse image processing is performed on a THz image of fresh rat brain tissue. It presents an excellent result with accurate information for the brain tissue after interference elimination.