Johannes Georg Keller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Johannes Georg Keller has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Robert Landsiedel
BASF SE, Ludwigshafen Am Rhein, Germany
6 shared publications - Wendel Wohlleben
BASF SE, Carl-Bosch-Str. 38, 67056 Ludwigshafen, Germany
6 shared publications - Kai Werle
BASF SE, Department Experimental Toxicology and Ecology, and Department Material Physics, Ludwigshafen 67056, Germany
3 shared publications - Philipp Müller
BASF SE, Solid‐State Microstructures Ludwigshafen am Rhein Germany
3 shared publications - Josje Arts
Nouryon, Zutphenseweg 10, 7418 AJ, Deventer, the Netherlands
2 shared publications Kai Werle
Department of Material Physics and Department of Experimental Toxicology and Ecology, BASF SE, Ludwigshafen, Germany
2 shared publications
Latest Publications
- 16 February 2023
- Published by Elsevier in NanoImpact
- Vol. 29, 100455
Corrigendum to variation in dissolution behavior among different nanoforms and its implication for grouping approaches in inhalation toxicity [NanoImpact 23 (2021) 100341]
- 16 February 2023
- Published by Elsevier in NanoImpact
- Vol. 29, 100455
Corrigendum to variation in dissolution behavior among different nanoforms and its implication for grouping approaches in inhalation toxicity [NanoImpact 23 (2021) 100341]
- Open Access
- 1 July 2021
- Published by Elsevier in NanoImpact
- Vol. 23, 100341
Variation in dissolution behavior among different nanoforms and its implication for grouping approaches in inhalation toxicity
- 1 July 2021
- Published by Elsevier in NanoImpact
- Vol. 23, 100341
Open AccessVariation in dissolution behavior among different nanoforms and its implication for grouping approaches in inhalation toxicity
- Open Access
- 4 June 2021
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 12 (1) , 525-540
The preparation temperature influences the physicochemical nature and activity of nanoceria
Cerium oxide nanoparticles, so-called nanoceria, are engineered nanomaterials prepared by many methods that result in products with varying physicochemical properties and applications. Those used industrially are often calcined, an example is NM-212. Other nanoceria have beneficial pharmaceutical properties and are often prepared by solvothermal synthesis. Solvothermally synthesized nanoceria dissolve in acidic environments, accelerated by carboxylic acids. NM-212 dissolution has been reported to be minimal. To gain insight into the role of high-temperature exposure on nanoceria dissolution, product susceptibility to carboxylic acid-accelerated dissolution, and its effect on biological and catalytic properties of nanoceria, the dissolution of NM-212, a solvothermally synthesized nanoceria material, and a calcined form of the solvothermally synthesized nanoceria material (ca. 40, 4, and 40 nm diameter, respectively) was investigated. Two dissolution methods were employed. Dissolution of NM-212 and the calcined nanoceria was much slower than that of the non-calcined form. The decreased solubility was attributed to an increased amount of surface Ce4+ species induced by the high temperature. Carboxylic acids doubled the very low dissolution rate of NM-212. Nanoceria dissolution releases Ce3+ ions, which, with phosphate, form insoluble cerium phosphate in vivo. The addition of immobilized phosphates did not accelerate nanoceria dissolution, suggesting that the Ce3+ ion release during nanoceria dissolution was phosphate-independent. Smaller particles resulting from partial nanoceria dissolution led to less cellular protein carbonyl formation, attributed to an increased amount of surface Ce3+ species. Surface reactivity was greater for the solvothermally synthesized nanoceria, which had more Ce3+ species at the surface. The results show that temperature treatment of nanoceria can produce significant differences in solubility and surface cerium valence, which affect the biological and catalytic properties of nanoceria.
- 4 June 2021
- Published by Beilstein Institut in Beilstein Journal of Nanotechnology
- Vol. 12 (1) , 525-540
Open AccessThe preparation temperature influences the physicochemical nature and activity of nanoceria
Cerium oxide nanoparticles, so-called nanoceria, are engineered nanomaterials prepared by many methods that result in products with varying physicochemical properties and applications. Those used industrially are often calcined, an example is NM-212. Other nanoceria have beneficial pharmaceutical properties and are often prepared by solvothermal synthesis. Solvothermally synthesized nanoceria dissolve in acidic environments, accelerated by carboxylic acids. NM-212 dissolution has been reported to be minimal. To gain insight into the role of high-temperature exposure on nanoceria dissolution, product susceptibility to carboxylic acid-accelerated dissolution, and its effect on biological and catalytic properties of nanoceria, the dissolution of NM-212, a solvothermally synthesized nanoceria material, and a calcined form of the solvothermally synthesized nanoceria material (ca. 40, 4, and 40 nm diameter, respectively) was investigated. Two dissolution methods were employed. Dissolution of NM-212 and the calcined nanoceria was much slower than that of the non-calcined form. The decreased solubility was attributed to an increased amount of surface Ce4+ species induced by the high temperature. Carboxylic acids doubled the very low dissolution rate of NM-212. Nanoceria dissolution releases Ce3+ ions, which, with phosphate, form insoluble cerium phosphate in vivo. The addition of immobilized phosphates did not accelerate nanoceria dissolution, suggesting that the Ce3+ ion release during nanoceria dissolution was phosphate-independent. Smaller particles resulting from partial nanoceria dissolution led to less cellular protein carbonyl formation, attributed to an increased amount of surface Ce3+ species. Surface reactivity was greater for the solvothermally synthesized nanoceria, which had more Ce3+ species at the surface. The results show that temperature treatment of nanoceria can produce significant differences in solubility and surface cerium valence, which affect the biological and catalytic properties of nanoceria.
- 26 October 2020
- Published by Taylor & Francis in Nanotoxicology
- Vol. 15 (1) , 21-34
Dosimetry in vitro – exploring the sensitivity of deposited dose predictions vs. affinity, polydispersity, freeze-thawing, and analytical methods
Dose-response by in vitro testing is only valid if the fraction of the particle dose that deposits onto adherent cells is known. Modeling tools such as the ‘distorted grid’ (DG) code are common practices to predict that fraction. As another challenge, workflow efficiency depends on parallelized sample preparation, for which freeze-thaw protocols have been explored earlier, but not their implications on dosimetry. Here we assess the sensitivity of the DG code toward freeze-thaw protocols and variations in user-defined parameters, including the estimation of particle-cell affinity and determination of agglomerate size, which we measure by DLS or AUC. We challenge the sensitivity by materials of varying composition, surface functionalization, and size (TiO2, CeO2, BaSO4, 2x Ag, 3x SiO2). We found that the average effective density is robust, but the dose predictions by different approaches varied typically 2-fold and up to 10-fold; this uncertainty translates directly into the uncertainty of no-effect-concentrations. The use of standardized dispersion protocols increases the uncertainty in doses. The choice of a measurement method and minor details of the particle size distribution strongly influence the modeled dosimetry. Uncertainty is high for very well dispersed nanomaterials; since then, the assumed affinity of particles to cells has a decisive influence. Against this background, the modulation of deposited dose by freeze-thaw protocols is a minor factor that can be controlled by aligning the protocols of sample preparation. However, even then, the uncertainty of deposited doses must be considered when comparing the in vitro toxicity of different nanomaterials.
- 26 October 2020
- Published by Taylor & Francis in Nanotoxicology
- Vol. 15 (1) , 21-34
Dosimetry in vitro – exploring the sensitivity of deposited dose predictions vs. affinity, polydispersity, freeze-thawing, and analytical methods
Dose-response by in vitro testing is only valid if the fraction of the particle dose that deposits onto adherent cells is known. Modeling tools such as the ‘distorted grid’ (DG) code are common practices to predict that fraction. As another challenge, workflow efficiency depends on parallelized sample preparation, for which freeze-thaw protocols have been explored earlier, but not their implications on dosimetry. Here we assess the sensitivity of the DG code toward freeze-thaw protocols and variations in user-defined parameters, including the estimation of particle-cell affinity and determination of agglomerate size, which we measure by DLS or AUC. We challenge the sensitivity by materials of varying composition, surface functionalization, and size (TiO2, CeO2, BaSO4, 2x Ag, 3x SiO2). We found that the average effective density is robust, but the dose predictions by different approaches varied typically 2-fold and up to 10-fold; this uncertainty translates directly into the uncertainty of no-effect-concentrations. The use of standardized dispersion protocols increases the uncertainty in doses. The choice of a measurement method and minor details of the particle size distribution strongly influence the modeled dosimetry. Uncertainty is high for very well dispersed nanomaterials; since then, the assumed affinity of particles to cells has a decisive influence. Against this background, the modulation of deposited dose by freeze-thaw protocols is a minor factor that can be controlled by aligning the protocols of sample preparation. However, even then, the uncertainty of deposited doses must be considered when comparing the in vitro toxicity of different nanomaterials.
- Open Access
- 12 February 2020
- Published by MDPI AG in Nanomaterials
- Vol. 10 (2) , 311
Understanding Dissolution Rates via Continuous Flow Systems with Physiologically Relevant Metal Ion Saturation in Lysosome
Dissolution rates of nanomaterials can be decisive for acute in vivo toxicity (via the released ions) and for biopersistence (of the remaining particles). Continuous flow systems (CFSs) can screen for both aspects, but operational parameters need to be adjusted to the specific physiological compartment, including local metal ion saturation. CFSs have two adjustable parameters: the volume flow-rate and the initial particle loading. Here we explore the pulmonary lysosomal dissolution of nanomaterials containing the metals Al, Ba, Zn, Cu over a wide range of volume flow-rates in a single experiment. We identify the ratio of particle surface area (SA) per volume flow-rate (SA/V) as critical parameter that superimposes all dissolution rates of the same material. Three complementary benchmark materials—ZnO (quick dissolution), TiO2 (very slow dissolution), and BaSO4 (partial dissolution)—consistently identify the SA/V range of 0.01 to 0.03 h/μm as predictive for lysosomal pulmonary biodissolution. We then apply the identified method to compare against non-nanoforms of the same substances and test aluminosilicates. For BaSO4 and TiO2, we find high similarity of the dissolution rates of their respective nanoform and non-nanoform, governed by the local ion solubility limit at relevant SA/V ranges. For aluminosilicates, we find high similarity of the dissolution rates of two Kaolin nanoforms but significant dissimilarity against Bentonite despite the similar composition.
- 12 February 2020
- Published by MDPI AG in Nanomaterials
- Vol. 10 (2) , 311
Open AccessUnderstanding Dissolution Rates via Continuous Flow Systems with Physiologically Relevant Metal Ion Saturation in Lysosome
Dissolution rates of nanomaterials can be decisive for acute in vivo toxicity (via the released ions) and for biopersistence (of the remaining particles). Continuous flow systems (CFSs) can screen for both aspects, but operational parameters need to be adjusted to the specific physiological compartment, including local metal ion saturation. CFSs have two adjustable parameters: the volume flow-rate and the initial particle loading. Here we explore the pulmonary lysosomal dissolution of nanomaterials containing the metals Al, Ba, Zn, Cu over a wide range of volume flow-rates in a single experiment. We identify the ratio of particle surface area (SA) per volume flow-rate (SA/V) as critical parameter that superimposes all dissolution rates of the same material. Three complementary benchmark materials—ZnO (quick dissolution), TiO2 (very slow dissolution), and BaSO4 (partial dissolution)—consistently identify the SA/V range of 0.01 to 0.03 h/μm as predictive for lysosomal pulmonary biodissolution. We then apply the identified method to compare against non-nanoforms of the same substances and test aluminosilicates. For BaSO4 and TiO2, we find high similarity of the dissolution rates of their respective nanoform and non-nanoform, governed by the local ion solubility limit at relevant SA/V ranges. For aluminosilicates, we find high similarity of the dissolution rates of two Kaolin nanoforms but significant dissimilarity against Bentonite despite the similar composition.
- Open Access
- 1 October 2018
- Published by Elsevier in NanoImpact
- Vol. 12, 29-41
Abiotic dissolution rates of 24 (nano)forms of 6 substances compared to macrophage-assisted dissolution and in vivo pulmonary clearance: Grouping by biodissolution and transformation
- 1 October 2018
- Published by Elsevier in NanoImpact
- Vol. 12, 29-41
Open AccessAbiotic dissolution rates of 24 (nano)forms of 6 substances compared to macrophage-assisted dissolution and in vivo pulmonary clearance: Grouping by biodissolution and transformation
- Open Access
- 13 March 2018
- Published by MDPI AG in Nanomaterials
- Vol. 8 (3) , 160
In Vitro and In Vivo Short-Term Pulmonary Toxicity of Differently Sized Colloidal Amorphous SiO2
In vitro prediction of inflammatory lung effects of well-dispersed nanomaterials is challenging. Here, the in vitro effects of four colloidal amorphous SiO2 nanomaterials that differed only by their primary particle size (9, 15, 30, and 55 nm) were analyzed using the rat NR8383 alveolar macrophage (AM) assay. Data were compared to effects of single doses of 15 nm and 55 nm SiO2 intratracheally instilled in rat lungs. In vitro, all four elicited the release of concentration-dependent lactate dehydrogenase, β-glucuronidase, and tumor necrosis factor alpha, and the two smaller materials also released H2O2. All effects were size-dependent. Since the colloidal SiO2 remained well-dispersed in serum-free in vitro conditions, effective particle concentrations reaching the cells were estimated using different models. Evaluating the effective concentration–based in vitro effects using the Decision-making framework for the grouping and testing of nanomaterials, all four nanomaterials were assigned as “active.” This assignment and the size dependency of effects were consistent with the outcomes of intratracheal instillation studies and available short-term rat inhalation data for 15 nm SiO2. The study confirms the applicability of the NR8383 AM assay to assessing colloidal SiO2 but underlines the need to estimate and consider the effective concentration of such well-dispersed test materials.
- 13 March 2018
- Published by MDPI AG in Nanomaterials
- Vol. 8 (3) , 160
Open AccessIn Vitro and In Vivo Short-Term Pulmonary Toxicity of Differently Sized Colloidal Amorphous SiO2
In vitro prediction of inflammatory lung effects of well-dispersed nanomaterials is challenging. Here, the in vitro effects of four colloidal amorphous SiO2 nanomaterials that differed only by their primary particle size (9, 15, 30, and 55 nm) were analyzed using the rat NR8383 alveolar macrophage (AM) assay. Data were compared to effects of single doses of 15 nm and 55 nm SiO2 intratracheally instilled in rat lungs. In vitro, all four elicited the release of concentration-dependent lactate dehydrogenase, β-glucuronidase, and tumor necrosis factor alpha, and the two smaller materials also released H2O2. All effects were size-dependent. Since the colloidal SiO2 remained well-dispersed in serum-free in vitro conditions, effective particle concentrations reaching the cells were estimated using different models. Evaluating the effective concentration–based in vitro effects using the Decision-making framework for the grouping and testing of nanomaterials, all four nanomaterials were assigned as “active.” This assignment and the size dependency of effects were consistent with the outcomes of intratracheal instillation studies and available short-term rat inhalation data for 15 nm SiO2. The study confirms the applicability of the NR8383 AM assay to assessing colloidal SiO2 but underlines the need to estimate and consider the effective concentration of such well-dispersed test materials.