Jonathan James Grandy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jonathan James Grandy has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Janusz Pawliszyn
University of Waterloo
7 shared publications Janusz Pawliszyn
4 shared publications- Varoon Singh
Department of Chemistry, University of Waterloo, 200 University Avenue west, Waterloo, Ontario, N2L 3G1, Canada
4 shared publications - Emanuela Gionfriddo
Department of Chemistry and Biochemistry, University of Toledo, Toledo, OH, 43606, USA; Department of Chemistry, University at Buffalo, The State University of New York, Buffalo, NY, 14260-3000, USA
3 shared publications - Germán Augusto Gómez-Ríos
Department of Chemistry, University of Waterloo , Waterloo, Ontario N2L 3G1, Canada
3 shared publications - Barbara Bojko
Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, 85-089 Bydgoszcz, Poland
2 shared publications
Latest Publications
- 25 November 2020
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 54 (24) , 15789-15799
Comprehensive Analysis of Multiresidue Pesticides from Process Water Obtained from Wastewater Treatment Facilities Using Solid-Phase Microextraction
A novel magnetic blade spray–tandem mass spectrometry (MBS-MS/MS) assay was developed and optimized, and its performance was characterized for the analysis of 204 pesticides from wastewater treatment facility (WWTF) process water. These results were compared and experimentally validated with an untargeted, high-resolution MS (HRMS) approach that employed liquid chromatography (LC)-amenable thin-film microextraction (TFME) devices to further elucidate the fate of pesticides through the WWTF process. As a result of our optimizations, we report an optimized workflow with an extraction time of 10 min, 150 μg of magnetic HLB particles, and 5 s of desorption. Excellent linearity was obtained for 168 of the 204 pesticides in deionized water, where 90% of the quantifiable pesticides had a determination coefficient (R2) of 0.99 across 3 orders of magnitude and 80% had limits of quantification below 0.5 ng/mL. We subsequently applied our optimized MBS-MS/MS method for the analysis of samples collected during the various stages of wastewater treatment from two WWTFs in Southern Ontario. This article presents a new streamlined methodology with a fast turnaround time for analyzing a large panel of pesticides, ultimately providing us the opportunity to evaluate the performance of two WWTFs for their efficacy in removing these toxic chemicals.
- 25 November 2020
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 54 (24) , 15789-15799
Comprehensive Analysis of Multiresidue Pesticides from Process Water Obtained from Wastewater Treatment Facilities Using Solid-Phase Microextraction
A novel magnetic blade spray–tandem mass spectrometry (MBS-MS/MS) assay was developed and optimized, and its performance was characterized for the analysis of 204 pesticides from wastewater treatment facility (WWTF) process water. These results were compared and experimentally validated with an untargeted, high-resolution MS (HRMS) approach that employed liquid chromatography (LC)-amenable thin-film microextraction (TFME) devices to further elucidate the fate of pesticides through the WWTF process. As a result of our optimizations, we report an optimized workflow with an extraction time of 10 min, 150 μg of magnetic HLB particles, and 5 s of desorption. Excellent linearity was obtained for 168 of the 204 pesticides in deionized water, where 90% of the quantifiable pesticides had a determination coefficient (R2) of 0.99 across 3 orders of magnitude and 80% had limits of quantification below 0.5 ng/mL. We subsequently applied our optimized MBS-MS/MS method for the analysis of samples collected during the various stages of wastewater treatment from two WWTFs in Southern Ontario. This article presents a new streamlined methodology with a fast turnaround time for analyzing a large panel of pesticides, ultimately providing us the opportunity to evaluate the performance of two WWTFs for their efficacy in removing these toxic chemicals.
- 29 October 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (23) , 14072-14080
Development of a Hydrophilic Lipophilic Balanced Thin Film Solid Phase Microextraction Device for Balanced Determination of Volatile Organic Compounds
A novel hydrophilic-lipophilic balanced (HLB) thin film solid phase microextraction (TF-SPME) device is proposed for polarity-balanced determinations of volatile organic compounds. The proposed HLB particles used in the preparation of these membranes were prepared using a precipitation polymerization technique, and determined to have a specific surface area of 335 m2/g with an average pore diameter of 13 Å. Membranes prepared from these particles were found to extract 1.8, 2.2, 1.9, 1.7, 2.0, and 1.3 times more benzene, 2-pentanone, 1-nitropropane, pyridine, 1-pentanol, and octane, respectively, than the established DVB/PDMS-based membranes. Furthermore, membranes prepared from these lab-made particles were shown to extract significantly (p = 0.00047) larger amounts of these analytes than membranes prepared from comparative commercial HLB particles. The inter-membrane extraction efficiency between 3 membranes was determined to be reproducible at 95% confidence for 4 different coating chemistries tested, including the DVB/PDMS membranes, and those prepared with 3 different HLB compositions. Furthermore, method reliability was established by confirming that, once extracted, modified McReynolds standards were stable on the HLB/PDMS membranes stored in thermal desorption tubes on an autosampler rack for at least 120 hours, for 5 of the 6 standards, but only for 24 hours for pyridine at a 95% level of confidence. Finally, using a TF-SPME enabled, portable GC-MS instrument, an entirely on-site proof of concept application was performed for the determination and quantitation of chlorination by-products in a private hot tub, successfully identifying chloroform, bromodichloromethane, dichloroacetonitrile, chlorobenzene, benzonitrile, and benzyl chloride, while further quantifying chloroform and dichloroacetonitrile at levels of 270 ppb and 79 ppb with %RSD values of 13% and 5%, respectively.
- 29 October 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (23) , 14072-14080
Development of a Hydrophilic Lipophilic Balanced Thin Film Solid Phase Microextraction Device for Balanced Determination of Volatile Organic Compounds
A novel hydrophilic-lipophilic balanced (HLB) thin film solid phase microextraction (TF-SPME) device is proposed for polarity-balanced determinations of volatile organic compounds. The proposed HLB particles used in the preparation of these membranes were prepared using a precipitation polymerization technique, and determined to have a specific surface area of 335 m2/g with an average pore diameter of 13 Å. Membranes prepared from these particles were found to extract 1.8, 2.2, 1.9, 1.7, 2.0, and 1.3 times more benzene, 2-pentanone, 1-nitropropane, pyridine, 1-pentanol, and octane, respectively, than the established DVB/PDMS-based membranes. Furthermore, membranes prepared from these lab-made particles were shown to extract significantly (p = 0.00047) larger amounts of these analytes than membranes prepared from comparative commercial HLB particles. The inter-membrane extraction efficiency between 3 membranes was determined to be reproducible at 95% confidence for 4 different coating chemistries tested, including the DVB/PDMS membranes, and those prepared with 3 different HLB compositions. Furthermore, method reliability was established by confirming that, once extracted, modified McReynolds standards were stable on the HLB/PDMS membranes stored in thermal desorption tubes on an autosampler rack for at least 120 hours, for 5 of the 6 standards, but only for 24 hours for pyridine at a 95% level of confidence. Finally, using a TF-SPME enabled, portable GC-MS instrument, an entirely on-site proof of concept application was performed for the determination and quantitation of chlorination by-products in a private hot tub, successfully identifying chloroform, bromodichloromethane, dichloroacetonitrile, chlorobenzene, benzonitrile, and benzyl chloride, while further quantifying chloroform and dichloroacetonitrile at levels of 270 ppb and 79 ppb with %RSD values of 13% and 5%, respectively.
- Top Cited PapersOpen Access
- 8 November 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (1) , 302-360
Advances in Solid Phase Microextraction and Perspective on Future Directions
- 8 November 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (1) , 302-360
Top Cited PapersOpen AccessAdvances in Solid Phase Microextraction and Perspective on Future Directions
- 12 June 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (15) , 8021-8026
Deposition of a Sorbent into a Recession on a Solid Support To Provide a New, Mechanically Robust Solid-Phase Microextraction Device
To date, solid-phase microextraction (SPME) fibers used for in vivo bioanalysis can be too fragile and flexible, which limits suitability for direct tissue sampling. As a result, these devices often require a sheathing needle to prepuncture robust sample matrixes and protect the extraction phase from mechanical damage. To address this limitation, a new SPME device is herein presented which incorporates an extraction phase recessed into the body of a solid needle. This device requires no additional support or shielding during puncture events through protective tissue. The presented device was thoroughly tested, being fired at 90 m·s–1 through fish scales, forced through vial septa, and employed in a targeted study of polyunsaturated fatty acids in salmon where the protective outer skin was repetitively punctured during sampling. Finally, the recessed SPME device was applied to an on-site application for the tissue analysis of wild muskellunge. With this advancement, rapid, minimally invasive, and easily executed in vivo SPME is now possible opening the door to near endless sampling opportunities.
- 12 June 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (15) , 8021-8026
Deposition of a Sorbent into a Recession on a Solid Support To Provide a New, Mechanically Robust Solid-Phase Microextraction Device
To date, solid-phase microextraction (SPME) fibers used for in vivo bioanalysis can be too fragile and flexible, which limits suitability for direct tissue sampling. As a result, these devices often require a sheathing needle to prepuncture robust sample matrixes and protect the extraction phase from mechanical damage. To address this limitation, a new SPME device is herein presented which incorporates an extraction phase recessed into the body of a solid needle. This device requires no additional support or shielding during puncture events through protective tissue. The presented device was thoroughly tested, being fired at 90 m·s–1 through fish scales, forced through vial septa, and employed in a targeted study of polyunsaturated fatty acids in salmon where the protective outer skin was repetitively punctured during sampling. Finally, the recessed SPME device was applied to an on-site application for the tissue analysis of wild muskellunge. With this advancement, rapid, minimally invasive, and easily executed in vivo SPME is now possible opening the door to near endless sampling opportunities.
- Open Access
- 1 April 2017
- Published by Elsevier in Analytica Chimica Acta
- Vol. 964, 74-84
Inter-laboratory validation of a thin film microextraction technique for determination of pesticides in surface water samples
- 1 April 2017
- Published by Elsevier in Analytica Chimica Acta
- Vol. 964, 74-84
Open AccessInter-laboratory validation of a thin film microextraction technique for determination of pesticides in surface water samples
- 23 June 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (13) , 6859-6866
Solid Phase Microextraction On-Fiber Derivatization Using a Stable, Portable, and Reusable Pentafluorophenyl Hydrazine Standard Gas Generating Vial
Solid phase microextraction (SPME) on-fiber derivatization methods have facilitated the achievement of lower detection limits and targeted analysis of various substances that exhibit poor chromatographic behavior, thermal instability, or high reactivity while limiting the use of organic solvents. However, previously developed on-fiber derivatization methods have been hindered by poor loading reproducibility and standard lifetime due to derivatization reagent reactivity. In addition, this reactivity often results in these reagents demonstrating toxic effects, complicating handling and standard formulation. To address this, a reusable standard gas generating vial containing pentafluorophenyl hydrazine (PFPH) has been developed. With this development SPME fibers can now be reproducibly loaded with derivatization reagent, from an easy to use and safe platform. Validation of the vial using C4-C9 linear aldehyde standards as target analytes demonstrated intra-batch vial reproducibility (2% RSD, n=4), along with PFPH headspace stability over a period of 11 weeks, facilitating reduced reagent consumption due to standard longevity. In addition, reproducibility of the derivatization reaction was observed over 1 week (RSD 0.996, 10-200 ppb v/v). Finally, the PFPH-generating vial was applied to the monitoring of volatile aldehydes generated during meat spoilage, as well as an on-site application where the free and total concentration of formaldehyde was determined in car exhaust using a portable GC-MS. To the best of our knowledge, the standard gas generating vial proposed in this work is the first documented device for the long term storage of a reusable headspace standards for a reactive, toxic and otherwise unstable derivatization reagent standard.
- 23 June 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (13) , 6859-6866
Solid Phase Microextraction On-Fiber Derivatization Using a Stable, Portable, and Reusable Pentafluorophenyl Hydrazine Standard Gas Generating Vial
Solid phase microextraction (SPME) on-fiber derivatization methods have facilitated the achievement of lower detection limits and targeted analysis of various substances that exhibit poor chromatographic behavior, thermal instability, or high reactivity while limiting the use of organic solvents. However, previously developed on-fiber derivatization methods have been hindered by poor loading reproducibility and standard lifetime due to derivatization reagent reactivity. In addition, this reactivity often results in these reagents demonstrating toxic effects, complicating handling and standard formulation. To address this, a reusable standard gas generating vial containing pentafluorophenyl hydrazine (PFPH) has been developed. With this development SPME fibers can now be reproducibly loaded with derivatization reagent, from an easy to use and safe platform. Validation of the vial using C4-C9 linear aldehyde standards as target analytes demonstrated intra-batch vial reproducibility (2% RSD, n=4), along with PFPH headspace stability over a period of 11 weeks, facilitating reduced reagent consumption due to standard longevity. In addition, reproducibility of the derivatization reaction was observed over 1 week (RSD 0.996, 10-200 ppb v/v). Finally, the PFPH-generating vial was applied to the monitoring of volatile aldehydes generated during meat spoilage, as well as an on-site application where the free and total concentration of formaldehyde was determined in car exhaust using a portable GC-MS. To the best of our knowledge, the standard gas generating vial proposed in this work is the first documented device for the long term storage of a reusable headspace standards for a reactive, toxic and otherwise unstable derivatization reagent standard.
- Open Access
- 11 January 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (3) , 1760-1767
Development of a Carbon Mesh Supported Thin Film Microextraction Membrane As a Means to Lower the Detection Limits of Benchtop and Portable GC/MS Instrumentation
In this work, a durable and easy to handle thin film microextraction (TFME) device is reported. The membrane is comprised of poly-divinylbenzene (DVB) resin particles suspended in a high-density polydimethylsiloxane (PDMS) glue, which is spread onto a carbon fiber mesh. The currently presented membrane was shown to exhibit a substantially lesser amount of siloxane bleed during thermal desorption, while providing a statistically similar extraction efficiency towards a broad spectrum of analytes varying in polarity when compared to an unsupported DVB/PDMS membrane of similar shape and size which was prepared with previously published methods. With the use of hand-portable GC-TMS instrumentation, membranes cut with dimensions 40 mm long by 4.85 mm wide and 40+/-5 µm thick (per side) were shown to extract 21.2, 19.8, 18.5, 18,4, 26.8, and 23.7 times the amount of 2,4 dichlorophenol 2,4,6 trichlorophenol, phorate D10, fonofos, chloropyrifos, and parathion, respectively, within 15 minutes from a 10 ppb aqueous solution as compared to a 65 µm DVB/PDMS solid phase microextraction (SPME) fiber. A portable high volume desorption module prototype was also evaluated, and shown to be appropriate for the desorption of analytes with a volatility equal to or lesser than benzene when employed in conjunction with TFME membranes. Indeed, the coupling of these TFME devices to hand-portable GC-MS instrumentation was shown to push detection limits for these pesticides down to the hundreds of ppt levels, nearing that which can be achieved with benchtop instrumentation. Where these membranes can also be coupled to benchtop instrumentation it is reasonable to assume that detection limits could be pushed down even further. As a final proof of the concept, the first ever, entirely on-site TFME/GC/TMS analysis was performed at a construction impacted lake. Results had indicated the presence of contaminants such as toluene, ethylbenzene, xylene, 2,2,4-Trimethyl-1,3-pentanediol diisobutyrate, and Tris(1-chloro-2-propyl)phosphate, which stood out from other naturally occurring compounds detected.
- 11 January 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (3) , 1760-1767
Open AccessDevelopment of a Carbon Mesh Supported Thin Film Microextraction Membrane As a Means to Lower the Detection Limits of Benchtop and Portable GC/MS Instrumentation
In this work, a durable and easy to handle thin film microextraction (TFME) device is reported. The membrane is comprised of poly-divinylbenzene (DVB) resin particles suspended in a high-density polydimethylsiloxane (PDMS) glue, which is spread onto a carbon fiber mesh. The currently presented membrane was shown to exhibit a substantially lesser amount of siloxane bleed during thermal desorption, while providing a statistically similar extraction efficiency towards a broad spectrum of analytes varying in polarity when compared to an unsupported DVB/PDMS membrane of similar shape and size which was prepared with previously published methods. With the use of hand-portable GC-TMS instrumentation, membranes cut with dimensions 40 mm long by 4.85 mm wide and 40+/-5 µm thick (per side) were shown to extract 21.2, 19.8, 18.5, 18,4, 26.8, and 23.7 times the amount of 2,4 dichlorophenol 2,4,6 trichlorophenol, phorate D10, fonofos, chloropyrifos, and parathion, respectively, within 15 minutes from a 10 ppb aqueous solution as compared to a 65 µm DVB/PDMS solid phase microextraction (SPME) fiber. A portable high volume desorption module prototype was also evaluated, and shown to be appropriate for the desorption of analytes with a volatility equal to or lesser than benzene when employed in conjunction with TFME membranes. Indeed, the coupling of these TFME devices to hand-portable GC-MS instrumentation was shown to push detection limits for these pesticides down to the hundreds of ppt levels, nearing that which can be achieved with benchtop instrumentation. Where these membranes can also be coupled to benchtop instrumentation it is reasonable to assume that detection limits could be pushed down even further. As a final proof of the concept, the first ever, entirely on-site TFME/GC/TMS analysis was performed at a construction impacted lake. Results had indicated the presence of contaminants such as toluene, ethylbenzene, xylene, 2,2,4-Trimethyl-1,3-pentanediol diisobutyrate, and Tris(1-chloro-2-propyl)phosphate, which stood out from other naturally occurring compounds detected.
- 1 September 2015
- Published by Elsevier in Journal of Chromatography A
- Vol. 1410, 1-8
Development of a standard gas generating vial comprised of a silicon oil–polystyrene/divinylbenzene composite sorbent
- 1 September 2015
- Published by Elsevier in Journal of Chromatography A
- Vol. 1410, 1-8
Development of a standard gas generating vial comprised of a silicon oil–polystyrene/divinylbenzene composite sorbent