Yusheng Jason He has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Austeja Staneviciute
Department of Biomedical Engineering Illinois Institute of Technology 3255 South Dearborn Street, Suite 314 Chicago IL 60616 USA
2 shared publications- Georgia Papavasiliou
Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, USA
2 shared publications - Narutoshi Hibino
Section of Cardiac Surgery, Department of Surgery, The University of Chicago, Chicago, IL 60637, USA
2 shared publications Chengyue Li
Biomedical Engineering Department, Illinois Institute of Technology, Chicago, Illinois 60616, United States
1 shared publication- Chin Siang Ong
Yale University
1 shared publication Daniel A. Young
Biomedical Engineering Department, Illinois Institute of Technology, Chicago, Illinois 60616, United States
1 shared publication
Latest Publications
- 1 November 2021
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 27 (21-22) , 1368-1375
Fast-Degrading Tissue-Engineered Vascular Grafts Lead to Increased Extracellular Matrix Cross-Linking Enzyme Expression
Tissue-engineered vascular grafts (TEVGs) require adequate extracellular matrix (ECM) to withstand arterial pressure. Tissue transglutaminase (TG2) and lysyl oxidase (LOX) are enzymes that cross-link ECM proteins and play a pivotal role in the development of vascular stiffness associated with aging. The purpose of this study is to investigate the expression of ECM cross-linking enzymes and mechanisms of scaffold degeneration leading to vascular stiffness in TEVG remodeling. Fast- and slow-degrading electrospun TEVGs were fabricated using polydioxanone (PDO) and poly(L-lactide-co-caprolactone) (PLCL) copolymer, with a PDO/PLCL ratio of 9:1 for fast-degrading and 1:1 for slow-degrading graft. These grafts were implanted in rats (n=5/group) as abdominal aortic interposition conduits. The grafts were harvested at one month to evaluate patency, mechanical properties, vascular neotissue formation and the expression of ECM cross-linking enzymes. All TEVGs were patent without any aneurysmal formation at one month. ECM area, TG2 positive area and LOX positive area were significantly greater in fast-degrading TEVGs compared to slow-degrading TEVGs, with significantly less remaining scaffold. The mechanical properties of fast-degrading TEVGs were similar to that of native aorta, as demonstrated by strain-stress curve. In conclusion, at one month, fast-degrading TEVGs had rapid and well-organized ECM with greater TG2 and LOX expression and native-like mechanical properties, compared to slow-degrading TEVGs.
- 1 November 2021
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 27 (21-22) , 1368-1375
Fast-Degrading Tissue-Engineered Vascular Grafts Lead to Increased Extracellular Matrix Cross-Linking Enzyme Expression
Tissue-engineered vascular grafts (TEVGs) require adequate extracellular matrix (ECM) to withstand arterial pressure. Tissue transglutaminase (TG2) and lysyl oxidase (LOX) are enzymes that cross-link ECM proteins and play a pivotal role in the development of vascular stiffness associated with aging. The purpose of this study is to investigate the expression of ECM cross-linking enzymes and mechanisms of scaffold degeneration leading to vascular stiffness in TEVG remodeling. Fast- and slow-degrading electrospun TEVGs were fabricated using polydioxanone (PDO) and poly(L-lactide-co-caprolactone) (PLCL) copolymer, with a PDO/PLCL ratio of 9:1 for fast-degrading and 1:1 for slow-degrading graft. These grafts were implanted in rats (n=5/group) as abdominal aortic interposition conduits. The grafts were harvested at one month to evaluate patency, mechanical properties, vascular neotissue formation and the expression of ECM cross-linking enzymes. All TEVGs were patent without any aneurysmal formation at one month. ECM area, TG2 positive area and LOX positive area were significantly greater in fast-degrading TEVGs compared to slow-degrading TEVGs, with significantly less remaining scaffold. The mechanical properties of fast-degrading TEVGs were similar to that of native aorta, as demonstrated by strain-stress curve. In conclusion, at one month, fast-degrading TEVGs had rapid and well-organized ECM with greater TG2 and LOX expression and native-like mechanical properties, compared to slow-degrading TEVGs.
- 29 January 2021
- Published by Wiley in Advanced Healthcare Materials
- Vol. 10 (7) , 2001706-e2001706
Cell‐Laden Gradient Hydrogel Scaffolds for Neovascularization of Engineered Tissues
Gradients in mechanical properties, physical architecture and biochemical composition exist in a variety of complex tissues, yet 3D in vitro models that enable investigation of these cues on cellular processes, especially those contributing to vascularization of engineered tissues are limited. Here, a photopolymerization approach to create cell‐laden hydrogel biomaterials with decoupled and combined gradients in modulus, immobilized cell adhesive peptide (RGD) concentration, and proteolytic degradation enabling spatial encapsulation of vascular spheroids is reported to elucidate their impact on vascular sprouting in 3D culture. Vascular spheroids encapsulated in these gradient scaffolds exhibit spatial variations in total sprout length. Scaffolds presenting an immobilized RGD gradient promote biased vascular sprouting toward increasing RGD concentration. Importantly, biased sprouting is found to be dependent on immobilized RGD gradient characteristics, including magnitude and slope, with increases in these factors contributing to significant enhancements in biased sprouting responses. Conversely, reduction in biased sprouting responses is observed in combined gradient scaffolds possessing opposing gradients in RGD and modulus. The presented work is the first to demonstrate the use of a cell‐laden biomaterial platform to systematically investigate the role of multiple scaffold gradients as well as gradient slope, magnitude and orientation on vascular sprouting responses in 3D culture.
- 29 January 2021
- Published by Wiley in Advanced Healthcare Materials
- Vol. 10 (7) , 2001706-e2001706
Cell‐Laden Gradient Hydrogel Scaffolds for Neovascularization of Engineered Tissues
Gradients in mechanical properties, physical architecture and biochemical composition exist in a variety of complex tissues, yet 3D in vitro models that enable investigation of these cues on cellular processes, especially those contributing to vascularization of engineered tissues are limited. Here, a photopolymerization approach to create cell‐laden hydrogel biomaterials with decoupled and combined gradients in modulus, immobilized cell adhesive peptide (RGD) concentration, and proteolytic degradation enabling spatial encapsulation of vascular spheroids is reported to elucidate their impact on vascular sprouting in 3D culture. Vascular spheroids encapsulated in these gradient scaffolds exhibit spatial variations in total sprout length. Scaffolds presenting an immobilized RGD gradient promote biased vascular sprouting toward increasing RGD concentration. Importantly, biased sprouting is found to be dependent on immobilized RGD gradient characteristics, including magnitude and slope, with increases in these factors contributing to significant enhancements in biased sprouting responses. Conversely, reduction in biased sprouting responses is observed in combined gradient scaffolds possessing opposing gradients in RGD and modulus. The presented work is the first to demonstrate the use of a cell‐laden biomaterial platform to systematically investigate the role of multiple scaffold gradients as well as gradient slope, magnitude and orientation on vascular sprouting responses in 3D culture.
- 18 February 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 8 (12) , 2454-2465
An in vitro tissue model for screening sustained release of phosphate-based therapeutic attenuation of pathogen-induced proteolytic matrix degradation
Tissue response to intestinal injury or disease releases pro-inflammatory host stress signals triggering microbial shift to pathogenic phenotypes. One such phenotype is increased protease production resulting in collagen degradation and activation of host matrix metalloproteinases contributing to tissue breakdown. We have shown that surgical injury depletes local intestinal phosphate concentration triggering bacterial virulence and that polyphosphate replenishment attenuates virulence and collagenolytic activity. Mechanistic studies of bacterial and host protease expression contributing to tissue breakdown are difficult to achieve in vivo necessitating the development of novel in vitro tissue models. Common techniques for screening in vitro protease activity, including gelatin zymography or fluorogenic protease-sensitive substrate kits, do not readily translate to 3D matrix degradation. Here, we report the application of an in vitro assay in which collagenolytic pathogens are cultured in the presence of a proteolytically degradable poly(ethylene) glycol scaffold and a non-degradable phosphate and/or polyphosphate nanocomposite hydrogel matrix. This in vitro platform enables quantification of pathogen-induced matrix degradation and screening of sustained release of phosphate-based therapeutic efficacy in attenuating protease expression. To evaluate matrix degradation as a function of bacterial enzyme levels secreted, we also present a novel method to quantify hydrogel degradation. This method involves staining protease-sensitive hydrogels with Sirius red dye to correlate absorbance of the degraded gel solution with hydrogel weight. This assay enables continuous monitoring and greater accuracy of hydrogel degradation kinetics compared to gravimetric measurements. Combined, the proposed in vitro platform and the presented degradation assay provide a novel strategy for screening efficacy of therapeutics in attenuating bacterial protease-induced matrix degradation.
- 18 February 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 8 (12) , 2454-2465
An in vitro tissue model for screening sustained release of phosphate-based therapeutic attenuation of pathogen-induced proteolytic matrix degradation
Tissue response to intestinal injury or disease releases pro-inflammatory host stress signals triggering microbial shift to pathogenic phenotypes. One such phenotype is increased protease production resulting in collagen degradation and activation of host matrix metalloproteinases contributing to tissue breakdown. We have shown that surgical injury depletes local intestinal phosphate concentration triggering bacterial virulence and that polyphosphate replenishment attenuates virulence and collagenolytic activity. Mechanistic studies of bacterial and host protease expression contributing to tissue breakdown are difficult to achieve in vivo necessitating the development of novel in vitro tissue models. Common techniques for screening in vitro protease activity, including gelatin zymography or fluorogenic protease-sensitive substrate kits, do not readily translate to 3D matrix degradation. Here, we report the application of an in vitro assay in which collagenolytic pathogens are cultured in the presence of a proteolytically degradable poly(ethylene) glycol scaffold and a non-degradable phosphate and/or polyphosphate nanocomposite hydrogel matrix. This in vitro platform enables quantification of pathogen-induced matrix degradation and screening of sustained release of phosphate-based therapeutic efficacy in attenuating protease expression. To evaluate matrix degradation as a function of bacterial enzyme levels secreted, we also present a novel method to quantify hydrogel degradation. This method involves staining protease-sensitive hydrogels with Sirius red dye to correlate absorbance of the degraded gel solution with hydrogel weight. This assay enables continuous monitoring and greater accuracy of hydrogel degradation kinetics compared to gravimetric measurements. Combined, the proposed in vitro platform and the presented degradation assay provide a novel strategy for screening efficacy of therapeutics in attenuating bacterial protease-induced matrix degradation.
- 25 September 2018
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 19 (11) , 4168-4181
Protease-Sensitive Hydrogel Biomaterials with Tunable Modulus and Adhesion Ligand Gradients for 3D Vascular Sprouting
Biomaterial strategies focused on designing scaffolds with physiologically relevant gradients provide a promising means for elucidating 3D vascular cell responses to spatial and temporal variations in matrix properties. In this study we present a photopolymerization approach, ascending photo-frontal free-radical polymerization, to generate proteolytically degradable hydrogel scaffolds of poly(ethylene) glycol (PEG) with tunable continuous gradients of (1) elastic modulus (slope of 80 Pa/mm) and uniform immobilized RGD concentration (2.06±0.12 mM) and (2) immobilized concentration of the RGD cell-adhesion peptide ligand (slope of 58.8 μM/mm) and uniform elastic modulus (597± 22Pa). Using a co-culture model of vascular sprouting, scaffolds embedded with gradients of elastic modulus induced increases in the number of vascular sprouts in the opposing gradient direction, while RGD gradient scaffolds promoted increases in the length of vascular sprouts towards the gradient. Furthermore, increases in vascular sprout length were found to be prominent in regions containing higher immobilized RGD concentration.
- 25 September 2018
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 19 (11) , 4168-4181
Protease-Sensitive Hydrogel Biomaterials with Tunable Modulus and Adhesion Ligand Gradients for 3D Vascular Sprouting
Biomaterial strategies focused on designing scaffolds with physiologically relevant gradients provide a promising means for elucidating 3D vascular cell responses to spatial and temporal variations in matrix properties. In this study we present a photopolymerization approach, ascending photo-frontal free-radical polymerization, to generate proteolytically degradable hydrogel scaffolds of poly(ethylene) glycol (PEG) with tunable continuous gradients of (1) elastic modulus (slope of 80 Pa/mm) and uniform immobilized RGD concentration (2.06±0.12 mM) and (2) immobilized concentration of the RGD cell-adhesion peptide ligand (slope of 58.8 μM/mm) and uniform elastic modulus (597± 22Pa). Using a co-culture model of vascular sprouting, scaffolds embedded with gradients of elastic modulus induced increases in the number of vascular sprouts in the opposing gradient direction, while RGD gradient scaffolds promoted increases in the length of vascular sprouts towards the gradient. Furthermore, increases in vascular sprout length were found to be prominent in regions containing higher immobilized RGD concentration.