TMThiago Dantas Matos

Thiago Dantas Matos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thiago Dantas Matos has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    ENDOSCOPIC DECOMPRESSION IN PATIENTS WITH ADJACENT SEGMENT STENOSIS AFTER LUMBAR ARTHRODESIS

    by Ricardo Esperidião, Adriano Passaglia Esperidião, Fernando Sepulveda Esperidião, Thiago Dantas Matos, Álvaro Diego Heredia Soarez, Marcelo Botelho Soares de Brito, Sonja Ellen Lobo, João Paulo Machado Bergamaschi

    Introduction and objective: Endoscopic decompression has emerged as an effective and minimally invasive therapeutic alternative for the management of adjacent-level stenosis in patients previously undergoing lumbar fusion. This condition, known as Adjacent Segment Disease (ASD), often manifests years after the surgical procedure, with clinical symptoms such as sciatica, neurogenic claudication, and progressive functional impairment. This study presents a series of clinical cases investigating the results of the endoscopic approach in patients diagnosed with foraminal and central stenosis at a single level adjacent to fusion. Methods: The fully endoscopic technique used allows direct access to the stenosed area with minimal aggression to surrounding tissues, promoting effective neural decompression, reduced perioperative morbidity, and accelerated recovery. Results and conclusion: Preliminary results suggest that endoscopic decompression may represent a viable and advantageous strategy compared to conventional approaches, especially in patients at high surgical risk or seeking less invasive options. Level of Evidence IV; Case Series.

  • Open Access

    MORPHOLOGIC CHANGES OF LUMBAR FORAMEN AND SEGMENTAL LORDOSIS RELATED TO CAGE POSITION IN TRANSFORAMINAL LUMBAR INTERBODY FUSION

    by Thiago Dantas Matos, Luis Fernando Tirapelli, Alexandre Machado Andrade, Vitor Araujo Gonçalves, Matheus Pippa Defino, Helton Luiz Aparecido Defino

    Objectives: To evaluate the influence of the positioning of cages on segmental lumbar lordosis and height of the intervertebral foramen when performing transforaminal interbody fusion. Method: cages of 8, 10 and 12 mm were inserted into the disc spaces of the L3-L4, L4-L5 and L5-S1 segments of three human cadavers. Cages were positioned in the anterior, middle and posterior part of the disc space. The transforaminal interbody fusion technique was performed using: unilateral facetectomy, bilateral facetectomy and facetectomy with resection of the adjacent lamina, spinous process and yellow ligament (posterior column osteotomy). The lordosis of the lumbar segment and the height of the intervertebral foramen were measured before and after placement of the cages. Results: The placement of cages in the anterior and middle portion of the disc space produced an increase in segmental lordosis and placement in the posterior portion reduced segmental lordosis. The height of the intervertebral foramen increased with the placement of cages in the posterior portion and a reduction in height with the placement of the interbody spacer in the anterior and middle portion of the disc space. Conclusion: The positioning of the interbody spacer in transforaminal interbody arthrodesis influences segmental lumbar lordosis and the height of the intervertebral foramen. Level of Evidence III; Experimental study.

  • Open Access

    CHANGES OF VERTEBRAL SEGMENT AND FORAMEN WITH ANTERIOR INTERBODY SPACER

    by Thiago Dantas Matos, Luis Fernando Tirapelli, Alexandre Machado Andrade, Vitor Araujo Gonçalves, Matheus Pippa Defino, Helton Luiz Aparecido Defino

    Objective: To evaluate the influence of intersomatic spacers used in ALIF on segmental lordosis and height of the intervertebral foramen. Methods: Intersomatic spacers with different heights (17, 18, 20 and 24 mm), length (20, 25 and 30 mm), and angulation (30 and 40 degrees) were introduced in segments L4-L5 and L5-S1 of two adult cadavers according to the ALIF technique. The lordosis of the vertebral segment and the height of the intervertebral foramina were evaluated before and after placement of the different intersomatic spacers. Results: An increase in segmental lordosis was observed with the placement of spacers in relation to the initial values. No statistical difference was observed between the different intersomatic spacers. The height of the intervertebral foramen increased with the placement of spacers and a statistical difference was observed between the different intersomatic spacers. Conclusion: Segmental lordosis increased with the placement of spacers compared to the control group. There was no statistical difference between the different heights and angles of the spacers. The height of the intervertebral foramen increased with the introduction of spacers. A statistically significant difference was observed with the increase in height and angle of the spacers. Level of Evidence III; Experimental study.

  • Open Access

    Uso de guia tridimensional personalizado no preparo do orifício do pedículo piloto em deformidades da coluna vertebral

    by Kelsen de Oliveira Teixeira, Thiago Dantas Matos, Rodrigo Barra Caiado Fleury, Herton Rodrigo Tavares Costa, Helton Luiz Aparecido Defino

    Resumo: Objetivo O presente estudo teve como objetivo desenvolver e avaliar a utilização de guias personalizadas em pacientes submetidos a cirurgia para correção de deformidades vertebrais com sistema de fixação pedicular. Métodos Quatro pacientes com deformidade espinhal (três casos de escoliose idiopática e um caso de cifoescoliose congênita) foram submetidos a tratamento cirúrgico corretivo com sistema de fixação pedicular. Protótipos de guias tridimensionais foram desenvolvidos e avaliados quanto à viabilidade técnica, precisão e exposição à radiação. Resultados O presente estudo incluiu 85 pedículos vertebrais submetidos à inserção de parafusos pediculares na coluna torácica (65,8%) e na coluna lombar (34,2%). A viabilidade técnica foi positiva em 46 pedículos vertebrais (54,1%), sendo 25 torácicos (54%) e 21 lombares (46%). A viabilidade técnica foi negativa em 39 pedículos (45,9%), sendo 31 torácicos (79,5%) e 8 lombares (20,5%). Quanto à precisão, 36 parafusos foram centralizados (78,2%), sendo 17 na coluna torácica (36,9%) e 19 na coluna lombar (41,3%). O mau posicionamento foi observado em 10 parafusos (21,7%), sendo 8 na coluna torácica (17,4%) e 2 na coluna lombar (4,3%). A radiação média registrada nos procedimentos cirúrgicos foi de 5,17 ± 0,72 mSv, e o tempo total de uso da fluoroscopia em cada cirurgia variou de 180,3 a 207,2 segundos. Conclusão Os protótipos de guias personalizadas permitiram o preparo seguro do orifício piloto nos pedículos vertebrais em casos de deformidade, com maior precisão e menor exposição intraoperatória à radiação.


  • Open Access

    CERVICAL SPONDYLOTIC MYELOPATHY: IS A COMBINED APPROACH NECESSARY?

    by Kelsen de Oliveira Teixeira, Luis Enrique Moncada Moreno, Thiago Dantas Matos, Rodrigo Barra Caiado Fleury, Herton Rodrigo Tavares Costa, Helton Luiz Aparecido Defino

    Objective: Cervical spondylotic myelopathy (CSM) is the main cause of spinal dysfunction in adults. The type of surgical approach to treatment is not well defined in the literature. The objective is to report the results obtained through isolated posterior decompression in patients with a previous indication of the combined approach for the treatment of cervical spondylotic myelopathy. Methods: This is a therapeutic study with level of evidence II, according to the Oxford classification table. Ten patients who underwent isolated posterior approach surgery for the treatment of cervical spondylotic myelopathy were evaluated through imaging and questionnaires (visual analog scale, mJOA-Br scale – Brazilian Portuguese version of the Modified Japanese Orthopedic Association Scale, and Neck Disability Index (NDI)), comparing pre- and postoperative results. Results: Late evaluation of the 10 patients was performed in the period ranging from 24 to 36 months (mean of 30.3 months ± 7.25) following surgery. The comparison of the clinical and radiological parameters in all patients showed a statistical difference in relation to the preoperative scales applied and to the degree of cervical lordosis (p <0.05), evidencing improvement after decompression and posterior fixation of the cervical spine. Conclusions: The isolated posterior approach (decompression, fixation and arthrodesis) allowed the clinical and radiological improvement of patients with cervical spondylotic myelopathy and who had an indication of the complementary anterior approach. Level of evidence II; Retrospective study.

  • Open Access

    INFLUENCE OF THE CONGRUENCE OF PILOT HOLE TAPPING ON THE ANCHORAGE OF THE PEDICLE SCREW

    by Rodrigo Barra Caiado Fleury, Antônio Carlos Shimano, Thiago Dantas Matos, Kelsen DE Oliveira Teixeira, Valéria Romero, Helton Luiz Aparecido Defino

    Objectives To observe the influence of the congruence of the tapping of the pilot hole on the anchorage of the pedicle screws. Methods 5.5 and 6.5 mm screws from two vertebral fixation systems (Pedicol and Safe) were inserted into polyurethane blocks. Experimental groups were formed according to the pilot hole preparation: A- drilling with a 2.7 mm drill bit, B- Tapping of the pilot hole with a tap of lesser diameter than the diameter of the screw with a congruent thread design, C- Tapping of the pilot hole with a tap of lesser diameter than the diameter of the screw and an incongruous thread design. The polyurethane blocks with the screws were subjected to a tensile strength test to evaluate the pullout resistance of the screws. Results Using congruent pilot hole tapping of a lesser diameter and congruent thread design increased the pullout resistance of the rough-surface screws (Safe). The screws with a smooth surface (Pedicol) presented greater pullout resistance with tapping of a lesser diameter and incongruous thread design. Conclusions The congruence of the tap used to prepare the pilot hole increased the pullout resistance of the rough-surfaced screws. Level of Evidence III; Therapeutic Study.

  • Open Access

    Influência da superfície dos parafusos pediculares no torque de inserção e resistência ao arrancamento

    by Rodrigo Barra Caiado Fleury, Antônio Carlos Shimano, Thiago Dantas Matos, Kelsen de Oliveira Teixeira, Valéria Romero, Helton Luiz Aparecido Defino

    Objetivo Comparar por testes mecânicos a resistência ao arrancamento e o torque de inserção do parafuso pedicularjateado e liso. Métodos Parafusos pediculares de superfície áspera e de superfície lisa com diâmetros de 4,8; 5,5 e 6,5 mm foram inseridos em blocos de poliuretano com densidade de 10 PCF (0,16 g/cm3). O torque de inserção e a força de arrancamento foram avaliados. Resultados A força de arrancamento dos parafusos de superfície áspera e de superfície lisa não diferiu, exceto no grupo de parafusos com 4,8 mm de diâmetro. Nesse grupo, os parafusos de superfície áspera apresentaram maior resistência ao arrancamento. Conclusão Os parafusos pediculares de superfície áspera não apresentaram aumento da resistência ao arrancamento na fase aguda de sua inserção em blocos de poliuretano em relação aos parafusos de superfície lisa. Os parafusos de superfície áspera apresentaram maior torque de inserção que os parafusos de superfície lisa, dependendo do diâmetro do parafuso e da preparação do furo piloto. Cada autor contribuiu individual e significativamente para o desenvolvimento deste artigo. Fleury R. B. C.(0000–0001–7643–6466) *: Contribuições substanciais para a concepção e desenho do trabalho, aquisição e interpretação de dados para o trabalho e aprovação final da versão a ser publicada; Shimano A. C.(0000–0002–3119–2362) *: contribuição para a coleta, análise e aprovação final dos dados; Matos T. D. (0000–0003–3853–502X) *: contribuição para a coleta e análise de dados; Teixeira K. O. (0000–0002–8165–2427) *: contribuição para a coleta e análise de dados; Romero V. (0000–0002–3278–5223) *: revisão para conteúdo intelectual importante; Defino H. L. A. (0000–0003–4274–0130) *: Contribuições substanciais para a concepção e desenho do trabalho, contribuições para a análise e interpretação dos dados para o trabalho e aprovação final da versão a ser publicada. ∗ Trabalho desenvolvido no Departamento de Biomecânica, Medicina e Reabilitação do Aparelho Locomotor, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brasil.


  • Open Access

    Mielopatia cervical secundária a gota: Relato de caso

    by Thiago Dantas Matos, Kelsen de Oliveira Teixeira, Rodrigo Barra Caiado Fleury, Herton Rodrigo Tavares Costa, Joel Del Bel Pádua, Helton Luiz Aparecido Defino

    A gota é uma artropatia cristalina frequente na população; entretanto, a espondiloartropatia gotosa, também chamada de gota axial, é incomum. O presente relato de caso apresenta um caso raro de mielopatia cervical secundária a gota axial. Uma paciente de 50 anos de idade, sem patologias prévias, apresentou quadro de perda de força, alteração de sensibilidade e liberação piramidal há 2 anos. A tomografia computadorizada evidenciou imagem lítica no processo espinhoso de C7, e sinais de mielopatia com mielomalácia foram observados na ressonância magnética da coluna cervical. Após o procedimento cirúrgico e biópsia do material, o diagnóstico foi de gota, e o tratamento para a patologia foi iniciado, com melhora completa do quadro. O diagnóstico de gota axial deve ser incluído no espectro do diagnóstico diferencial das doenças que acometem a coluna vertebral. Apesar de a espondiloartrite gotosa ser incomum, há uma ocorrência subestimada devido a não investigação dos casos. O diagnóstico precoce e tratamento da patologia pode evitar que pacientes apresentem complicações da doença, como a relatada no presente estudo. * Trabalho desenvolvido no Departamento de Ortopedia e Traumatologia da Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brasil.


  • Open Access

    CHANGES IN THE LUMBAR VERTEBRAL SEGMENT RELATED TO THE CAGE POSITION IN TLIF TECHNIQUE

    by Thiago Dantas Matos, Rodrigo Barra Caiado Fleury, Kelsen DE Oliveira Teixeira, Valéria Romero, Helton Luiz Aparecido Defino

    Objective: To evaluate the morphological changes on the intervertebral foramen and segmental lordosis related to the transforaminal lumbar interbody fusion (TLIF) positioning. Methods: PEEK cages were placed in the disc space (L1-S1) of a polyurethane anatomical model. Cages of different heights (8 mm, 10 mm, 12 mm and 14 mm) were positioned in the posterior, medial or anterior part of the vertebral body surface, and the intervertebral foramen and segmental lordosis heights were measured after their insertion. Results: The vertebral foramen height decreased in all positions and heights of the cages in relation to the control. The cage posterior positioning induced a smaller reduction in the vertebral foramen height. Vertebral lordosis tended to increase in relation to the control, and the greatest increase occurred with the cage posterior positioning. Conclusion: Cage positioning induces changes in the intervertebral foramen height and in the vertebral segment lordosis. Cage posterior positioning induces a smaller reduction of the intervertebral foramen height and increases the vertebral segment lordosis. Level of evidence III, Therapeutic study.


  • Open Access

    Rotational dislocation C1–C2 after otoplasty under local anesthesia

    by Thiago Dantas Matos, Romulo Pedroza Pinheiro, Herton Rodrigo Tavares Costa, Helton Luiz Aparecido Defino

    Non-traumatic rotational atlantoaxial subluxation (NTARS) is rare and mostly reported after infection of the upper respiratory tract and named Grisel's syndrome. NTARS has also been reported after head-and-neck surgery, but it is extremely rare after otoplasty. A case of NTARS after bilateral otoplasty is reported under local anesthesia, a 15-year-old female being presented with painful torticollis. The diagnosis of atlantoaxial rotatory subluxation was performed using radiographs and computed tomography 2 weeks after the surgery. Closed reduction was performed by traction of the head and transoral direct pressure over an anterior dislocated C1 mass. The reposition of the joint was achieved, but it was very unstable, and it was not possible to keep the reduction. Open posterior reduction and posterior C1–C2 arthrodesis were performed followed by the use of a soft collar during 3 months.