AOAlexander P. Osipov

Alexander P. Osipov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexander P. Osipov has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Multiplex gradient immunochip for detection of post-vaccinal antibodies in poultry

    by Nikolay Yu. Saushkin, Jeanne V. Samsonova, Galina V. Presnova, Maya Yu. Rubtsova, Alexander P. Osipov

    Multiplex analysis as an immunochip-in-a well format for simultaneous detection of post-vaccinal antibodies to three poultry infections (Newcastle disease, infectious bronchitis and bursal disease) in one chicken sera was developed. The immunochip had a microarray format printed on the bottom of a standard microtiter plate well and consisted of 36 microspots (d = 400 μm each) with three lines of viral antigens absorbed in a gradient of five decreasing concentrations. Optimization of assay conditions revealed the necessity of careful choice of the reaction buffer due to the high tendency of chicken IgY to exhibit unspecific binding. The best results were obtained for PBS buffer (pH 6.0) supplied with 0.1% Tween 20. Assay results were visualized by a number of coloured microspots that were correlated with the specific antibody titre in the analysed serum. High (> 8000), medium (3000–8000) or low (1000–3000) antibody titre level for each of three infections could be quickly assessed in one probe visually or with the help of smartphone. ELISA results (antibody titres) and visual gradient immunochip results interpretation (high, medium, low antibody level/titre) for 63 chicken sera with multiple levels of post-vaccinal antibodies against Newcastle disease, infectious bronchitis and bursal disease were in good correlation.

  • Comparative characteristics of immune-enzymatic systems for post vaccinal antibodies determination to three infection diseases

    by Zhanna V. Samsonova, Nikolay Yu. Saushkin, Alexander P. Osipov, Anna V. Ruzina, Alexey V. Frolov, Tatyana N. Rozhdestvenskaya

    Comparative investigation has been carried out of three immune-enzymatic systems from three producers for detection of post vaccinal antibodies to chicken infection bronchitis viruses, infection bursitis and Newcastle disease viruses. Parallel testing has been carried out for liquid blood serum samples and dry whole blood samples at membrane carrier. High results convergence has been received in dry and liquid parallel measuring for all test systems. The results correlation coefficients for antibodies determination to three diseases in “dry sample – liquid sample” system have been 0.88 to 0.92 for IDEXX set (USA); 0.76 to 0.8 for OOO “CVO” set (Russia) and 0.69 to 0.81 for FSBSI “FCAHP” set. Long- term stability of dry blood samples (5 years) has been proved at the example of antibodies determination to IBD and IВ.

  • Open Access

    Modern Systems of Train Traffic Interval Control on World Railways

    by A. P. Baturin, A. P. Osipov

    The review study is devoted to the analysis of the modern systems aimed at enhancing or replacing existing systems of rail automatics and refers to ERTMS (European Union), CTCS (PRC), ATACS (Japan), PTC (Unites States) and ABTS-MSH (Russian Federation). The review study discusses the main approaches and principles applied during the research and development of train traffic interval control systems, modern trends in their developments on public railways in Russia and other countries with the account for the scale of their adoption, offers tentative identification of problems that have arisen at the stages of implementation and operation and evaluation of the outlook for their further improvements.While each system merits detailed study, the prevailed approach focused on comparative system analysis and revealing differences and common tendencies regarding their further evolution.


  • Dried Blood Spots technology for veterinary applications and biological investigations: technical aspects, retrospective analysis, ongoing status and future perspectives

    by Jeanne V. Samsonova, Nikolay Yu. Saushkin, Alexander P. Osipov

    Dried Blood Spots (DBS) technology has become a valuable tool in medical studies, however, in veterinary and biological research DBS technology applications are still limited. Up-to-date no review has comprehensively integrated all the evidence existing across the fields, technologies and animal species. In this paper we summarize the current applications of DBS technology in the mentioned areas, and provide a scope of different types of dried sample carriers (cellulose and non-cellulose), sampling devices, applicable methods for analyte extraction and detection. Mammals, birds, insects and other species are represented as the study objects. Besides the blood, the review considers a variety of specimens, such as milk, saliva, tissue samples and others. The main applications of dried samples highlighted in the review include epidemiological surveys and monitoring for infections agents or specific antibodies for disease/vaccination control in households and wildlife. Besides the genetic investigations, the paper describes detection of environmental contaminants, pregnancy diagnosis and many other useful applications of animal dried samples. The paper also analyses dried sample stability and storage conditions for antibodies, viruses and other substances. Finally, recent developments and future research for DBS technology in veterinary medicine and biological sciences are discussed.


  • Dried Samples of Biological Fluids on Porous Membranes as a Promising Sample Preparation Method for Biomedical and Veterinary Diagnostics

    by J. V. Samsonova, N. Yu. Saushkin, A. P. Osipov

    The sample preparation method for liquid biosamples dried on a carrier (dried blood spot technology) has been increasingly used in various fields of bioanalysis, pharmacokinetics, therapeutic drug monitoring, toxicokinetics, metabolomics, and disease diagnostics over the past 20 years. The dried blood spot technology involves the application of a sample directly to the carrier; after drying, the sample is analyzed using modern analytical, immunochemical, and genetic methods. The advantages of this sample preparation method include minimal invasiveness; small sample volumes; ease and cost-effectiveness of sampling, transportation, and storage of samples; and high stability of analytes. The review considers the main aspects of the application of the sample preparation of biological fluids, suspensions, tissues, and organs in the form of dried spots on porous membrane carriers in analytical practice. The principles of using membrane carriers in order to obtain biological samples in the form of dried spots, approaches to their analytical application, interfering factors and limitations associated with the rheological properties of blood, types of devices for taking blood and other samples, and the current state and prospects for the development of dried spot technology are described.


  • Dried blood samples for transportation and analysis during poultry post-vaccination control

    by Lomonosov Moscow State University, J.V. Samsonova, N.YU. Saushkin, A.P. Osipov, S.S. Yakovlev, Moscow Spe Avivac Ltd., T.N. Rozhdestvenskaya


  • Strip-dried blood sampling: applicability for bovine leukemia virus detection with ELISA and real-time PCR

    by Nikolay Yu. Saushkin, Jeanne V. Samsonova, Alexander P. Osipov, Sergey E. Kondakov


  • Open Access

    Comparative research of effectiveness of cellulose and fiberglass porous membrane carriers for bio sampling in veterinary and food industry monitoring

    by Alexander Gusev, Inna Vasyukova, Olga Zakharova, Yuliya Altabaeva, Nikolai Saushkin, Jeanne Samsonova, Sergey Kondakov, Alexander Osipov, Eduard Snegin

    The aim of proposed research is to study the applicability of fiberglass porous membrane materials in a new strip format for dried blood storage in food industry monitoring. A comparative analysis of cellulosic and fiberglass porous membrane materials was carried out to obtain dried samples of serum or blood and the possibility of further species-specific analysis. Blood samples of Sus scrofa were used to study the comparative effectiveness of cellulose and fiberglass porous membrane carriers for long-term biomaterial storage allowing for further DNA detection by real-time polymerase chain reaction (PCR) method. Scanning electron microscopy of various membranes - native and with blood samples - indicate a fundamental difference in the form of dried samples. Membranes based on cellulosic materials sorb the components of the biological fluid on the surface of the fibers of their structure, partially penetrating the cellulose fibers, while in the case of glass fiber membranes the components of the biological fluid dry out as films in the pores of the membrane between the structural filaments. This fundamental difference in the retention mechanisms affects the rate of dissolution of the components of dry samples and contributes to an increase in the efficiency of the desorption process of the sample before subsequent analysis. Detecting of pig DNA in every analyzed sample under the performed Real-time PCR as well as good state of the biomaterial preservation on the glass fiber membranes was clearly demonstrated. Good biomaterials preservation has been revealed on the test cards for 4 days as well as for 1 hour.

  • Open Access

    Membrane materials for storing biological samples intended for comparative nanotoxicological testing

    by A Metelkin, D Kuznetsov, E Kolesnikov, K Chuprunov, S Kondakov, A Osipov, J Samsonova

    The study is aimed at identifying the samples of most promising membrane materials for storing dry specimens of biological fluids (Dried Blood Spots, DBS technology). Existing sampling systems using cellulose fiber filter paper have a number of drawbacks such as uneven distribution of the sample spot, dependence of the spot spreading area on the individual biosample properties, incomplete washing-off of the sample due to partially inconvertible sorption of blood components on cellulose fibers, etc. Samples of membrane materials based on cellulose, polymers and glass fiber with applied biosamples were studied using methods of scanning electron microscopy, FT-IR spectroscopy and surface-wetting measurement. It was discovered that cellulose-based membrane materials sorb components of biological fluids inside their structure, while membranes based on glass fiber display almost no interaction with the samples and biological fluid components dry to films in the membrane pores between the structural fibers. This characteristic, together with the fact that membrane materials based on glass fiber possess sufficient strength, high wetting properties and good storage capacity, attests them as promising material for dry samples of biological fluids storage systems.