DRDamaris Patricia Rojas

Damaris Patricia Rojas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Damaris Patricia Rojas has a total of 135 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Plan Quality Comparison at Five Years in Two Cohorts of Breast Cancer Patients Treated with Helical Tomotherapy

    by Samantha Dicuonzo, Maria Alessia Zerella, Mattia Zaffaroni, Maria Giulia Vincini, Karl Amin, Giuseppe Ronci, Micol D’arcangelo, Damaris Patricia Rojas, Anna Morra, Marianna Alessandra Gerardi, et al.

    Objectives: this study aimed to evaluate the evolution of planned dose distribution quality in two groups of breast cancer patients treated with hypofractionated intensity-modulated radiotherapy (IMRT) using Helical TomoTherapy® at our institute 5 years apart. Methods: the analysis included two cohorts of patients who underwent implant-based immediate breast reconstruction (IBR) and received post-mastectomy IMRT to the chest wall and infra/supraclavicular lymph nodes, following a 15-fraction regimen (2.67 Gy per fraction). The first group was treated between 2012 and 2015, while the second received treatment between 2019 and 2020. Dosimetric indices derived from dose–volume histograms used in clinical practice were analyzed to assess dose distribution quality. A quantitative scoring system was applied retrospectively to compare the two groups in terms of target coverage and organ-at-risk (OAR) sparing. Additionally, capsular contracture (CC) incidence was examined in both cohorts. Results: A total of 240 patients were included in the study. The percentage of optimal treatment plans increased from 70.8% in the 2012–2015 cohort to 77.5% in the 2019–2020 cohort, while compromised plans decreased from 10.8% to 7.5%. Furthermore, the incidence of moderate-to-severe CC dropped from 54.8% in the earlier cohort to 43.5% in the later one. Conclusions: Helical Tomotherapy® has demonstrated the ability to achieve a high rate of optimal treatment plans concerning both PTV coverage and OAR sparing in a challenging population of postmastectomy patients with IBR. The learning curve showed that, after 5 years, the rate of optimal plans was increased, accompanied by a reduction in compromised plans and treatment-related toxicity.

  • Salvage Breast-Conserving Surgery and Reirradiation With Intraoperative Electrons for Recurrent Breast Cancer: A Multicentric Study on Behalf of Italian Association of Radiotherapy and Clinical Oncology (AIRO)

    by Maria Cristina Leonardi, Alexandru David Fodor, Samuele Frassoni, Damaris Patricia Rojas, Alessandra Fozza, Gladys Blandino, Antonella Ciabattoni, Marina Alessandro, Gianpiero Catalano, Giovanni Battista Ivaldi, et al.


  • Open Access

    Tools to Guide Radiation Oncologists in the Management of DCIS

    by Maria Cristina Leonardi, Maria Alessia Zerella, Matteo Lazzeroni, Nicola Fusco, Paolo Veronesi, Viviana Enrica Galimberti, Giovanni Corso, Samantha Dicuonzo, Damaris Patricia Rojas, Anna Morra, et al.

    Similar to invasive breast cancer, ductal carcinoma in situ is also going through a phase of changes not only from a technical but also a conceptual standpoint. From prescribing radiotherapy to everyone to personalized approaches, including radiotherapy omission, there is still a lack of a comprehensive framework to guide radiation oncologists in decision making. Many pieces of the puzzle are finding their place as high-quality data mature and are disseminated, but very often, the interpretation of risk factors and the perception of risk remain very highly subjective. Sharing the therapeutic choice with patients requires effective communication for an understanding of risks and benefits, facilitating an informed decision that does not increase anxiety and concerns about prognosis. The purpose of this narrative review is to summarize the current state of knowledge to highlight the tools available to radiation oncologists for managing DCIS, with an outlook on future developments.


  • The POLO (Partially Omitted Lobe) approach to safely treat in-breast recurrence after intraoperative radiotherapy with electrons

    by Maria Cristina Leonardi, Andriana Kouloura, Damaris Patricia Rojas, Mattia Zaffaroni, Mattia Intra, Paolo Veronesi, Anna Morra, Marianna Alessandra Gerardi, Cristiana Iuliana Fodor, Maria Alessia Zerella, et al.

    Objectives: The aim of this study is to evaluate feasibility of salvage 4-week hypofractionated whole breast radiotherapy (WBRT) in patients with in-breast recurrence after receiving intraoperative radiotherapy with electrons (IOERT) for primary breast cancer (BC). Methods: BC patients who had repeated quadrantectomy underwent modified WBRT with intensity-modulated radiotherapy using Helical Tomotherapy to underdose the IOERT region. This approach, called POLO (Partially Omitted Lobe), excluded the IOERT volume from receiving the full prescription dose. Results: Nine patients were treated with this approach, receiving 45 Gy in 20 fractions. A simultaneous integrated boost of 2.5 Gy in 20 fractions was delivered in 6/9 patients. Dose constraints and planning objectives were reported. No severe toxicity was reported while local control and overall survival were 100%. Conclusion: The POLO approach is technically feasible and capable to achieve a significant reduction of radiation dose delivered to the previous treated IOERT area. Advances in knowledge: The study demonstrates the technical and dosimetric feasibility of conservative salvage whole breast radiotherapy, while sparing the area already treated with IORT, in patients with in-breast recurrence.


  • Geometric contour variation in clinical target volume of axillary lymph nodes in breast cancer radiotherapy: an AIRO multi-institutional study

    by Maria Cristina Leonardi, Matteo Pepa, Simone Giovanni Gugliandolo, Rosa Luraschi, Sabrina Vigorito, Anna Morra, Damaris Patricia Rojas, Maria Alessia Zerella, Johannes Lars Isaksson, Maria Rosa La Porta, et al.

    Objectives: To determine interobserver variability in axillary nodal contouring in breast cancer (BC) radiotherapy (RT) by comparing the clinical target volume of participating single centres (SC-CTV) with a gold-standard CTV (GS-CTV). Methods: The GS-CTV of three patients (P1, P2, P3) with increasing complexity was created in DICOM format from the median contour of axillary CTVs drawn by BC experts, validated using the simultaneous truth and performance-level estimation and peer-reviewed. GS-CTVs were compared with the correspondent SC-CTVs drawn by radiation oncologists, using validated metrics and a total score (TS) integrating all of them. Results: Eighteen RT centres participated in the study. Comparative analyses revealed that, on average, the SC-CTVs were smaller than GS-CTV for P1 and P2 (by −29.25% and −27.83%, respectively) and larger for P3 (by +12.53%). The mean Jaccard index was greater for P1 and P2 compared to P3, but the overlap extent value was around 0.50 or less. Regarding nodal levels, L4 showed the highest concordance with the GS. In the intra-patient comparison, L2 and L3 achieved lower TS than L4. Nodal levels showed discrepancy with GS, which was not statistically significant for P1, and negligible for P2, while P3 had the worst agreement. DICE similarity coefficient did not exceed the minimum threshold for agreement of 0.70 in all the measurements. Conclusions: Substantial differences were observed between SC- and GS-CTV, especially for P3 with altered arm setup. L2 and L3 were the most critical levels. The study highlighted these key points to address. Advances in knowledge: The present study compares, by means of validated geometric indexes, manual segmentations of axillary lymph nodes in breast cancer from different observers and different institutions made on radiotherapy planning CT images. Assessing such variability is of paramount importance, as geometric uncertainties might lead to incorrect dosimetry and compromise oncological outcome.


  • Breast Adjuvant Radiotherapy Amid the COVID-19 Crisis in a Hub Cancer Center, Lombardy, Italy

    by Maria Cristina Leonardi, Emilia Montagna, Viviana Enrica Galimberti, Mattia Zaffaroni, Damaris Patricia Rojas, Samantha Dicuonzo, Maria Alessia Zerella, Anna Morra, Claudia Sangalli, Sara Gandini, et al.

    Introduction: During the COVID-19 pandemic, Lombardy (Northern Italy) Regional Health Council created hubs for cancer care, meant to be SARS-CoV-2-free pathways for cancer patients. The workflow of breast cancer (BC) radiotherapy (RT) in one of the hubs is presented here. Methods: Candidates to adjuvant RT during the pandemic peak of March-April 2020 were compared to those treated in the same period of 2019, and patient volume, deferral rate, and type of RT were analyzed. Statistics were calculated with χ2 or Fisher exact tests for categorical variables, and the Wilcoxon rank test for continuous variables. Results: In March-April 2020 the BC patient volume increased by 28% compared to the same period in 2019 (scheduled patients: 175 vs. 137) and amid travel restrictions it was kept high (treated patients: 136 vs. 133), mainly due to an influx from across Lombardy. RT schemes basically did not change, being already centered on hypofractionation. The increase of median time (67 vs. 74.5 days in 2019 and 2020, respectively) to the commencement of RT for low-risk patients was clinically negligible yet statistically significant (p = 0.03), and in line with the pertinent recommendations. No significant difference was found in the time interval between treatments and RT for high-risk patients. Concomitant chemoradiotherapy was avoided throughout the pandemic peak. Twenty-one women (13.6%) delayed either computed tomography simulation or RT commencement mainly because of COVID-19-related concerns and mobility restrictions. Conclusion: The workload for BC was high during the pandemic peak. Hubs allowed the continuation of oncologic treatments, while mitigating the strain on frontline COVID-19 hospitals.


  • Reirradiation for isolated local recurrence of prostate cancer: Mono-institutional series of 64 patients treated with salvage stereotactic body radiotherapy (SBRT)

    by Barbara Alicja Jereczek-Fossa, Damaris Patricia Rojas, Dario Zerini, Cristiana Fodor, Anna Viola, Giuseppe Fanetti, Stefania Volpe, Rosa Luraschi, Alessia Bazani, Elena Rondi, et al.

    To evaluate high-precision external beam reirradiation (re-EBRT) for local relapse of prostate cancer (PCa) after radiotherapy. This retrospective study included patients with biochemical failure and evidence of isolated local recurrence of PCa after radical/salvage EBRT or brachytherapy that received salvage stereotactic body radiation therapy (SBRT, re-EBRT). Biopsy was not mandatory if all diagnostic elements were univocal (prostate specific antigen evolution, choline-positron emission tomography or magnetic resonance imaging). Salvage SBRT (re-EBRT) was delivered with image-guided radiation therapy (RapidArc®, VERO® and CyberKnife®). Data of 64 patients were included, median age at salvage SBRT was 73.2 years, median pre-salvage SBRT prostate specific antigen was 3.89 ng ml-1 . Median total dose was 30 Gy in five fractions, biologically effective dose (BED) of 150 Gy. One acute G3 genitourinary event and one late G3 genitourinary event were observed. No G ≥ 3 bowel toxicity was registered. At the median follow-up of 26.1 months, tumor progression was observed in 41 patients (64%). 18 patients (28%) experienced local relapse. 2-year local control, biochemical and clinical relapse free survival rates were 75, 40 and 53%, respectively. With BED ≥130 Gy 1-year biochemical and clinical progression-free survival rate were 85 and 90%, respectively. Salvage SBRT (re-EBRT) for isolated local PCa recurrence is a safe, feasible and noninvasive salvage treatment. Further investigation is warranted to define the optimal patient selection, dose and volume parameters. Salvage SBRT reirradiation for the locally recurrent PCa offer a satisfactory tumor control and excellent toxicity profile, if BED ≥130 Gy is administered.