Ravi Sankar Arunagirinathan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ravi Sankar Arunagirinathan has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Ribu Mathew
Manipal Academy of Higher Education
9 shared publications - Jothi Lavanya
Department of Physics, School of Advanced Sciences (SAS), Vellore Institute of Technology (VIT), Chennai Campus, Chennai, Tamil Nadu, India
7 shared publications - Srinivasan Raman
School of Electronics Engineering (SENSE), Vellore Institute of Technology (VIT), Chennai Campus, Chennai, Tamil Nadu, India
7 shared publications Ribu Mathew
School of Electrical and Electronics Engineering (SEEE), VIT Bhopal University, Bhopal, India
5 shared publicationsS. Das
5 shared publications- Saranya Sambathkumar
Centre for Innovation and Product Development (CIPD), Vellore Institute of Technology (VIT), Chennai Campus, Chennai 600 127, India
5 shared publications
Latest Publications
- Open Access
- 15 September 2026
- Published by Springer Nature in Scientific Reports
Interface-driven electrocatalytic activity of NiFe-LDH on MnO2-modified SWCNT hierarchical nanostructures for overall water splitting
- 15 September 2026
- Published by Springer Nature in Scientific Reports
Open AccessInterface-driven electrocatalytic activity of NiFe-LDH on MnO2-modified SWCNT hierarchical nanostructures for overall water splitting
- 28 February 2026
- Published by Springer Nature in Journal of Materials Science
- Vol. 61 (13) , 8685-8701
MWCNT-coated hemp fabric as a wide-range flexible piezoresistive pressure sensor for human motion monitoring and gesture recognition
- 28 February 2026
- Published by Springer Nature in Journal of Materials Science
- Vol. 61 (13) , 8685-8701
MWCNT-coated hemp fabric as a wide-range flexible piezoresistive pressure sensor for human motion monitoring and gesture recognition
- Open Access
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 215094-215109
A Highly Sensitive and Durable Flexible Pressure Sensor With a Multilayered Fabric Structure for IoT-Enabled Activity Tracking
Wearable sensors integrated with the Internet of Things (IoT) are continually researched and developed due to their ever-expanding applications in various fields, including personalized healthcare, human-machine interfaces, and soft robotics. Flexible pressure sensors (FPSs) stand out for their critical role in capturing motions using various mechanisms. Piezoresistive-type FPSs, which employ single-layer fabrics as substrates, rarely achieve significant sensitivity beyond the very low-pressure range, thereby failing to cover a wide range of motion signals with appreciable sensitivity. Despite several reports utilizing novel configurations, sensing material combinations, and fabrication steps, a strong demand remains for low-cost, high-performance FPSs integrated with IoT. In this work, we present a three-layer fabric-based piezoresistive FPS, with a substrate consisting of medical gauze sandwiched between two layers of silk-blend fabric. Acid-treated carbon black (CB) and multiwalled carbon nanotubes (MWCNTs) are used to coat the fabric blend in a simple dip-and-dry process. The biodegradable silk/cotton blend-based pressure sensor demonstrated notable sensitivities of 0.471 kPa-1, 0.0134 kPa-1, and 0.0012 kPa-1 across the pressure ranges of 0-1 kPa, 1-11 kPa, and 11-62 kPa, featuring a response time of 126 ms, a relaxation time of 46 ms, and excellent cycle stability, enduring 20,000 cycles. Capable of monitoring various bending motions and other signals, this MWCNT/CB/silk blend-based FPS, along with a wireless transmission system to send signals to a cloud accessible by authorized healthcare professionals, significantly advances next-generation devices in healthcare and diagnostics.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 215094-215109
Open AccessA Highly Sensitive and Durable Flexible Pressure Sensor With a Multilayered Fabric Structure for IoT-Enabled Activity Tracking
Wearable sensors integrated with the Internet of Things (IoT) are continually researched and developed due to their ever-expanding applications in various fields, including personalized healthcare, human-machine interfaces, and soft robotics. Flexible pressure sensors (FPSs) stand out for their critical role in capturing motions using various mechanisms. Piezoresistive-type FPSs, which employ single-layer fabrics as substrates, rarely achieve significant sensitivity beyond the very low-pressure range, thereby failing to cover a wide range of motion signals with appreciable sensitivity. Despite several reports utilizing novel configurations, sensing material combinations, and fabrication steps, a strong demand remains for low-cost, high-performance FPSs integrated with IoT. In this work, we present a three-layer fabric-based piezoresistive FPS, with a substrate consisting of medical gauze sandwiched between two layers of silk-blend fabric. Acid-treated carbon black (CB) and multiwalled carbon nanotubes (MWCNTs) are used to coat the fabric blend in a simple dip-and-dry process. The biodegradable silk/cotton blend-based pressure sensor demonstrated notable sensitivities of 0.471 kPa-1, 0.0134 kPa-1, and 0.0012 kPa-1 across the pressure ranges of 0-1 kPa, 1-11 kPa, and 11-62 kPa, featuring a response time of 126 ms, a relaxation time of 46 ms, and excellent cycle stability, enduring 20,000 cycles. Capable of monitoring various bending motions and other signals, this MWCNT/CB/silk blend-based FPS, along with a wireless transmission system to send signals to a cloud accessible by authorized healthcare professionals, significantly advances next-generation devices in healthcare and diagnostics.
- Open Access
- 4 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 191485-191500
Development of a Highly Stable and Selective Non-Enzymatic Electrochemical Glucose Sensor Using Nitrogen-Doped Graphene Nanoribbons/NiCu-Metal-Organic Frameworks Composite
Bimetallic metal-organic frameworks (MOFs) show promise for electrochemical applications despite challenges posed by their low electrical conductivity and stability. Here, we introduce bimetallic (NiCu)-MOFs anchored on nitrogen-doped graphene nanoribbons (NGNRs) to enhance conductivity and stability. Experimental investigations on a (NiCu)-MOFs/NGNRs-modified glassy carbon electrode revealed a maximum oxidation current of 148 μA and a minimum charge transfer resistance of 4.01 kΩ, indicating excellent electrocatalytic activity. We further evaluated the modified electrode’s performance for glucose sensing using cyclic voltammetry and chronoamperometry techniques, achieving a notable oxidation peak current of 519 μA, which confirms its superior electrochemical activity. The developed enzyme-free glucose sensor exhibits a wide dynamic range (1.16 μM – 4.5 mM), high sensitivity (181.67 μA mM-1 cm-2), short response time (3 s), and low detection limit (825 nM). Moreover, the proposed sensor exhibits better long-term stability, with a 96% amperometric response after seven days, and excellent selectivity in the presence of other interferents, such as ascorbic acid, dopamine, uric acid, and sucrose. This demonstrates its efficacy in human serum and non-alcoholic beverages.
- 4 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 191485-191500
Open AccessDevelopment of a Highly Stable and Selective Non-Enzymatic Electrochemical Glucose Sensor Using Nitrogen-Doped Graphene Nanoribbons/NiCu-Metal-Organic Frameworks Composite
Bimetallic metal-organic frameworks (MOFs) show promise for electrochemical applications despite challenges posed by their low electrical conductivity and stability. Here, we introduce bimetallic (NiCu)-MOFs anchored on nitrogen-doped graphene nanoribbons (NGNRs) to enhance conductivity and stability. Experimental investigations on a (NiCu)-MOFs/NGNRs-modified glassy carbon electrode revealed a maximum oxidation current of 148 μA and a minimum charge transfer resistance of 4.01 kΩ, indicating excellent electrocatalytic activity. We further evaluated the modified electrode’s performance for glucose sensing using cyclic voltammetry and chronoamperometry techniques, achieving a notable oxidation peak current of 519 μA, which confirms its superior electrochemical activity. The developed enzyme-free glucose sensor exhibits a wide dynamic range (1.16 μM – 4.5 mM), high sensitivity (181.67 μA mM-1 cm-2), short response time (3 s), and low detection limit (825 nM). Moreover, the proposed sensor exhibits better long-term stability, with a 96% amperometric response after seven days, and excellent selectivity in the presence of other interferents, such as ascorbic acid, dopamine, uric acid, and sucrose. This demonstrates its efficacy in human serum and non-alcoholic beverages.
- Open Access
- 11 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 124234-124249
Carbon Black-Coated Fabric Blend as Piezoresistive Flexible Pressure Sensor for Motion Monitoring Applications
Flexible pressure sensors (FPSs) have garnered significant interest among researchers focusing on wearable electronics for motion recognition, health care, rehabilitation therapy, athletic performance monitoring, and more applications. Recently, fabrics known for their flexibility and comfort have become popular substrates for fabricating various flexible sensors. Of these flexible sensors, piezoresistive devices are favored for their simplicity and notable sensitivity to physical movements. This study presents a fabric composite created by coating a viscose staple fiber/linen blend with functionalized conductive carbon black (CB) using a simple drop-coating method and evaluates its pressure-sensing performance. The FPS with optimum CB content exhibited sensitivities of 41.1 kPa-1 and 1.4 kPa-1 in the pressure ranges of 0-1 kPa and 1-20 kPa, respectively. With a low detection limit of 10 Pa, a response time of 16 ms, a relaxation time of 63 ms, durability exceeding 5,400 cycles, and stable performance in various ambient conditions, the FPS has exhibited potential for applications in bending motion monitoring and information transmission.
- 11 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 124234-124249
Open AccessCarbon Black-Coated Fabric Blend as Piezoresistive Flexible Pressure Sensor for Motion Monitoring Applications
Flexible pressure sensors (FPSs) have garnered significant interest among researchers focusing on wearable electronics for motion recognition, health care, rehabilitation therapy, athletic performance monitoring, and more applications. Recently, fabrics known for their flexibility and comfort have become popular substrates for fabricating various flexible sensors. Of these flexible sensors, piezoresistive devices are favored for their simplicity and notable sensitivity to physical movements. This study presents a fabric composite created by coating a viscose staple fiber/linen blend with functionalized conductive carbon black (CB) using a simple drop-coating method and evaluates its pressure-sensing performance. The FPS with optimum CB content exhibited sensitivities of 41.1 kPa-1 and 1.4 kPa-1 in the pressure ranges of 0-1 kPa and 1-20 kPa, respectively. With a low detection limit of 10 Pa, a response time of 16 ms, a relaxation time of 63 ms, durability exceeding 5,400 cycles, and stable performance in various ambient conditions, the FPS has exhibited potential for applications in bending motion monitoring and information transmission.
- 1 January 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (1) , 017508
Nitrogen-Enriched Sulfur-Functionalized Reduced Graphene Oxide Nanosheets for Non-Enzymatic Uric Acid Sensing and Supercapacitor Application
Reduced graphene oxide (RGO) was functionalized with nitrogen-enriched sulfur-containing groups via a facile and cost-effective hydrothermal approach to enhance the electrochemical performance of RGO nanosheets. The crystallinity, morphology, and chemical composition of obtained nitrogen-enriched sulfur-functionalized reduced graphene oxide (NESRGO) was investigated using X-ray diffraction, Raman spectroscopy, field-emission scanning electron microscopy, and X-ray photoelectron spectroscopy. The electrochemical investigation of NESRGO with higher electronegativity and improved electrical conductivity yielded a superior oxidation current of 52 μA towards uric acid (UA) than nitrogen sulfur-functionalized reduced graphene oxide (NSRGO) (30 μA) and RGO (21 μA). The NESRGO-modified electrode showed high sensitivity (826.25 μA mM−1 cm−2), a detection limit of 4 μM, and good stability (relative standard deviation of 3.69%). Moreover, the high selectivity of the developed UA sensor in the presence of other electroactive interferents and excellent recovery rates between 99.29% and 110.40% in human serum demonstrated the applicability of the sensor in clinical diagnosis. Finally, the NESRGO-modified carbon cloth electrode applied as a supercapacitor exhibited a specific capacitance of 70.23 F g−1 and excellent cycle stability, with 109.7% retention over 2,500 cycles. The results highlight the NESRGO’s potential in UA sensing and energy storage devices.
- 1 January 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (1) , 017508
Nitrogen-Enriched Sulfur-Functionalized Reduced Graphene Oxide Nanosheets for Non-Enzymatic Uric Acid Sensing and Supercapacitor Application
Reduced graphene oxide (RGO) was functionalized with nitrogen-enriched sulfur-containing groups via a facile and cost-effective hydrothermal approach to enhance the electrochemical performance of RGO nanosheets. The crystallinity, morphology, and chemical composition of obtained nitrogen-enriched sulfur-functionalized reduced graphene oxide (NESRGO) was investigated using X-ray diffraction, Raman spectroscopy, field-emission scanning electron microscopy, and X-ray photoelectron spectroscopy. The electrochemical investigation of NESRGO with higher electronegativity and improved electrical conductivity yielded a superior oxidation current of 52 μA towards uric acid (UA) than nitrogen sulfur-functionalized reduced graphene oxide (NSRGO) (30 μA) and RGO (21 μA). The NESRGO-modified electrode showed high sensitivity (826.25 μA mM−1 cm−2), a detection limit of 4 μM, and good stability (relative standard deviation of 3.69%). Moreover, the high selectivity of the developed UA sensor in the presence of other electroactive interferents and excellent recovery rates between 99.29% and 110.40% in human serum demonstrated the applicability of the sensor in clinical diagnosis. Finally, the NESRGO-modified carbon cloth electrode applied as a supercapacitor exhibited a specific capacitance of 70.23 F g−1 and excellent cycle stability, with 109.7% retention over 2,500 cycles. The results highlight the NESRGO’s potential in UA sensing and energy storage devices.
- Open Access
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 194566-194579
Wearable Flexible Pressure Sensor Based on Nitrogen-Functionalized CNT in Melamine Foam for Human Motion Monitoring
Flexible pressure sensors, with prominent applications in healthcare, human-computer interface, and motion monitoring, have garnered significant interest among researchers in recent times. Melamine foam (MF), valued for its porous structure and accessibility, is a preferred material for flexible pressure sensors. Various electrically conducting nanomaterials are incorporated into these foams to realize piezoresistive flexible sensors. Carbon nanotubes (CNTs), one of the filler materials used in these sensors, suffer from the issues of agglomeration and uneven dispersion when used as a single filler, which significantly affects the sensing properties of the piezoresistive foam-based sensors. Covalent functionalization, such as nitrogen doping, effectively addresses these issues and modifies the properties of carbon nanotubes (CNTs) to enhance their performance in various applications. In the present work, we have prepared a nitrogen-doped CNT (N-CNT) using a simple hydrothermal method and fabricated piezoresistive flexible pressure sensors using N-CNT/MF by facile dip coating method. The 4wt% N-CNT/MF pressure sensor worked in the 0-35 kPa range and showed a sensitivity of 0.172 kPa -1 in the 0-4 kPa range. With a low detection limit of 18 Pa, a response time of 0.4 s, and a relaxation time of 0.46 s, the sensor’s performance was stable for more than 1800 cycles. The sensor was tested for monitoring wrist, elbow, finger, and knee bendings and finger pressing, demonstrating its applicability in human motion monitoring applications.
- 16 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 194566-194579
Open AccessWearable Flexible Pressure Sensor Based on Nitrogen-Functionalized CNT in Melamine Foam for Human Motion Monitoring
Flexible pressure sensors, with prominent applications in healthcare, human-computer interface, and motion monitoring, have garnered significant interest among researchers in recent times. Melamine foam (MF), valued for its porous structure and accessibility, is a preferred material for flexible pressure sensors. Various electrically conducting nanomaterials are incorporated into these foams to realize piezoresistive flexible sensors. Carbon nanotubes (CNTs), one of the filler materials used in these sensors, suffer from the issues of agglomeration and uneven dispersion when used as a single filler, which significantly affects the sensing properties of the piezoresistive foam-based sensors. Covalent functionalization, such as nitrogen doping, effectively addresses these issues and modifies the properties of carbon nanotubes (CNTs) to enhance their performance in various applications. In the present work, we have prepared a nitrogen-doped CNT (N-CNT) using a simple hydrothermal method and fabricated piezoresistive flexible pressure sensors using N-CNT/MF by facile dip coating method. The 4wt% N-CNT/MF pressure sensor worked in the 0-35 kPa range and showed a sensitivity of 0.172 kPa -1 in the 0-4 kPa range. With a low detection limit of 18 Pa, a response time of 0.4 s, and a relaxation time of 0.46 s, the sensor’s performance was stable for more than 1800 cycles. The sensor was tested for monitoring wrist, elbow, finger, and knee bendings and finger pressing, demonstrating its applicability in human motion monitoring applications.
- 4 October 2024
- Published by IOP Publishing in Nanotechnology
- Vol. 35 (50) , 502002
A review on recent advances in g-C3N4-MXene nanocomposites for photocatalytic applications
The solutions for environmental remediation and renewable energy generation have intensified the exploration of efficient photocatalytic materials. Recently, the composites of g-C3N4 and MXene have gained considerable interest for their potential applications in photocatalysis. In the g-C3N4-MXene composite, the g-C3N4 possesses unique physical, chemical, and optical properties to increase visible light absorption. At the same time, MXene improves conductivity, adsorption of reactant molecules or the active sites, and charge transfer properties. Combining the unique physico-chemical properties of MXene and g-C3N4, the resulting composite exhibits superior photo-responsive behavior and is critical in photocatalytic reactions. Furthermore, the g-C3N4-MXene composite exhibits stability and recyclability, making it a promising candidate for sustainable and scalable photocatalytic material in environmental remediation. This review offers an in-depth analysis of the development and design of g-C3N4-MXene composites through diverse synthesis procedures and a comprehensive analysis of their application in carbon dioxide (CO2) reduction, photocatalytic degradation, water splitting processes, mainly hydrogen (H2) generation, H2O2 production, N2 fixation, and NO x removal. The charge transfer mechanism of g-C3N4-MXene composite for photocatalytic application has also been discussed. This review provides insights into the photocatalytic capabilities of g-C3N4-MXene composites, showing their potential to address current environmental challenges and establish a robust foundation for sustainable energy conversion technologies.
- 4 October 2024
- Published by IOP Publishing in Nanotechnology
- Vol. 35 (50) , 502002
A review on recent advances in g-C3N4-MXene nanocomposites for photocatalytic applications
The solutions for environmental remediation and renewable energy generation have intensified the exploration of efficient photocatalytic materials. Recently, the composites of g-C3N4 and MXene have gained considerable interest for their potential applications in photocatalysis. In the g-C3N4-MXene composite, the g-C3N4 possesses unique physical, chemical, and optical properties to increase visible light absorption. At the same time, MXene improves conductivity, adsorption of reactant molecules or the active sites, and charge transfer properties. Combining the unique physico-chemical properties of MXene and g-C3N4, the resulting composite exhibits superior photo-responsive behavior and is critical in photocatalytic reactions. Furthermore, the g-C3N4-MXene composite exhibits stability and recyclability, making it a promising candidate for sustainable and scalable photocatalytic material in environmental remediation. This review offers an in-depth analysis of the development and design of g-C3N4-MXene composites through diverse synthesis procedures and a comprehensive analysis of their application in carbon dioxide (CO2) reduction, photocatalytic degradation, water splitting processes, mainly hydrogen (H2) generation, H2O2 production, N2 fixation, and NO x removal. The charge transfer mechanism of g-C3N4-MXene composite for photocatalytic application has also been discussed. This review provides insights into the photocatalytic capabilities of g-C3N4-MXene composites, showing their potential to address current environmental challenges and establish a robust foundation for sustainable energy conversion technologies.
- 26 August 2024
- Published by Springer Nature in Journal of Materials Science
- Vol. 59 (34) , 15992-16019
Recent advances in ovarian cancer diagnosis using 2D nanomaterials-based electrochemical biosensors: a review
- 26 August 2024
- Published by Springer Nature in Journal of Materials Science
- Vol. 59 (34) , 15992-16019
Recent advances in ovarian cancer diagnosis using 2D nanomaterials-based electrochemical biosensors: a review