Witold Byrski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Witold Byrski has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jędrzej Byrski
AGH Akademia Górniczo-Hutnicza
6 shared publications - Michał Drapała
AGH University of Science and Technology
3 shared publications - Adam Kowalewski
AGH University of Science and Technology
1 shared publication - Andrzej Latocha
AGH University of Science and Technology
1 shared publication - Jozef Duda
AGH University of Science and Technology, Krakow, Poland
1 shared publication - Krzysztof Oprzędkiewicz
AGH University of Krakow
1 shared publication
Latest Publications
- Open Access
- 28 September 2022
- Published by Polish Academy of Sciences Chancellery in Archives of Control Sciences
- Vol. 32 (3) , 535-555
On-line process identification using the Modulating Functions Method and non-asymptotic state estimation
The paper presents an iterative identification method dedicated for industrial processes. The method consists of two steps. In the first step, a MISO system is identified with the Modulating Functions Method to obtain sub-models with a common denominator. In the second step, the obtained subsystems are re-identified. This procedure enables to obtain the set of models with different denominators of the transfer functions. The algorithmwas used for on-line identification of a glass conditioning process. Identification window is divided into intervals, in which the models can be updated based on recent process data, with the use of the integral state observer. Results of the performed simulations for the identified models are compared with the historical process data.
- 28 September 2022
- Published by Polish Academy of Sciences Chancellery in Archives of Control Sciences
- Vol. 32 (3) , 535-555
Open AccessOn-line process identification using the Modulating Functions Method and non-asymptotic state estimation
The paper presents an iterative identification method dedicated for industrial processes. The method consists of two steps. In the first step, a MISO system is identified with the Modulating Functions Method to obtain sub-models with a common denominator. In the second step, the obtained subsystems are re-identified. This procedure enables to obtain the set of models with different denominators of the transfer functions. The algorithmwas used for on-line identification of a glass conditioning process. Identification window is divided into intervals, in which the models can be updated based on recent process data, with the use of the integral state observer. Results of the performed simulations for the identified models are compared with the historical process data.
- 1 September 2022
- Published by Springer Nature
- p. 423-436
A New Version of the On-Line Adaptive Non-standard Identification Procedure for Continuous-Time MISO Physical Processes
- 1 September 2022
- Published by Springer Nature
- p. 423-436
A New Version of the On-Line Adaptive Non-standard Identification Procedure for Continuous-Time MISO Physical Processes
- 1 January 2022
- Published by AGH University Press
- p. 69-79
Wybrane metody modelowania, identyfikacji i sterowania systemów dynamicznych
- 1 January 2022
- Published by AGH University Press
- p. 69-79
Wybrane metody modelowania, identyfikacji i sterowania systemów dynamicznych
- Open Access
- 1 December 2019
- Published by University of Zielona Góra, Poland in International Journal of Applied Mathematics and Computer Science
- Vol. 29 (4) , 739-757
An Adaptive Identification Method Based on the Modulating Functions Technique and Exact State Observers for Modeling and Simulation of a Nonlinear Miso Glass Melting Process
The paper presents new concepts of the identification method based on modulating functions and exact state observers with its application for identification of a real continuous-time industrial process. The method enables transformation of a system of differential equations into an algebraic one with the same parameters. Then, these parameters can be estimated using the least-squares approach. The main problem is the nonlinearity of the MISO process and its noticeable transport delays. It requires specific modifications to be introduced into the basic identification algorithm. The main goal of the method is to obtain on-line a temporary linear model of the process around the selected operating point, because fast methods for tuning PID controller parameters for such a model are well known. Hence, a special adaptive identification approach with a moving window is proposed, which involves using on-line registered input and output process data. An optimal identification method for a MISO model assuming decomposition to many inner SISO systems is presented. Additionally, a special version of the modulating functions method, in which both model parameters and unknown delays are identified, is tested on real data sets collected from a glass melting installation.
- 1 December 2019
- Published by University of Zielona Góra, Poland in International Journal of Applied Mathematics and Computer Science
- Vol. 29 (4) , 739-757
Open AccessAn Adaptive Identification Method Based on the Modulating Functions Technique and Exact State Observers for Modeling and Simulation of a Nonlinear Miso Glass Melting Process
The paper presents new concepts of the identification method based on modulating functions and exact state observers with its application for identification of a real continuous-time industrial process. The method enables transformation of a system of differential equations into an algebraic one with the same parameters. Then, these parameters can be estimated using the least-squares approach. The main problem is the nonlinearity of the MISO process and its noticeable transport delays. It requires specific modifications to be introduced into the basic identification algorithm. The main goal of the method is to obtain on-line a temporary linear model of the process around the selected operating point, because fast methods for tuning PID controller parameters for such a model are well known. Hence, a special adaptive identification approach with a moving window is proposed, which involves using on-line registered input and output process data. An optimal identification method for a MISO model assuming decomposition to many inner SISO systems is presented. Additionally, a special version of the modulating functions method, in which both model parameters and unknown delays are identified, is tested on real data sets collected from a glass melting installation.
- Open Access
- 8 November 2018
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2018, 1-15
An Optimal Identification of the Input-Output Disturbances in Linear Dynamic Systems by the Use of the Exact Observation of the State
A new methodology for the identification of the values of unknown disturbance signals acting in the input and output measurements of the dynamic linear system is presented. For the solution of this problem, the new idea of the use of two different state observers, which are coworking simultaneously in parallel, was elaborated. Special integral type observers are operating on the same finite time window of the width T and both can reconstruct the exact value of the vector state x(T) on the basis of input-output measurements in this interval [0, T]. If in the input-output signals the disturbances are absent (measurements of I/O signals are perfect) then both observers (although they are different) reconstruct the exact and the same state x(T). However, if in the measurement signals the disturbances are present then these observers will reconstruct the different values of the final states x1(T)=x(T)+e1(T) and x2(T)=x(T)+e2(T). It is because they have different norms and hence they generate different errors in both estimated states. Because of the disturbances, the real state x(T) is unknown, but it is easy to calculate the state difference: x1(T)-x2(T)=e1(T)-e2(T). It occurs that, based on this difference, the values of all the disturbances acting during the control process can be identified. In the paper, the theory of the exact state observation and application of such observers in online mode is recalled. The new methodology for disturbances identification is presented.
- 8 November 2018
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2018, 1-15
Open AccessAn Optimal Identification of the Input-Output Disturbances in Linear Dynamic Systems by the Use of the Exact Observation of the State
A new methodology for the identification of the values of unknown disturbance signals acting in the input and output measurements of the dynamic linear system is presented. For the solution of this problem, the new idea of the use of two different state observers, which are coworking simultaneously in parallel, was elaborated. Special integral type observers are operating on the same finite time window of the width T and both can reconstruct the exact value of the vector state x(T) on the basis of input-output measurements in this interval [0, T]. If in the input-output signals the disturbances are absent (measurements of I/O signals are perfect) then both observers (although they are different) reconstruct the exact and the same state x(T). However, if in the measurement signals the disturbances are present then these observers will reconstruct the different values of the final states x1(T)=x(T)+e1(T) and x2(T)=x(T)+e2(T). It is because they have different norms and hence they generate different errors in both estimated states. Because of the disturbances, the real state x(T) is unknown, but it is easy to calculate the state difference: x1(T)-x2(T)=e1(T)-e2(T). It occurs that, based on this difference, the values of all the disturbances acting during the control process can be identified. In the paper, the theory of the exact state observation and application of such observers in online mode is recalled. The new methodology for disturbances identification is presented.
- 7 June 2017
- Published by Springer Nature in Advances in Intelligent Systems and Computing
- p. 536-549
A new method of multi-inertial systems identification by the Strejc model
- 7 June 2017
- Published by Springer Nature in Advances in Intelligent Systems and Computing
- p. 536-549
A new method of multi-inertial systems identification by the Strejc model
- Open Access
- 1 September 2016
- Published by University of Zielona Góra, Poland in International Journal of Applied Mathematics and Computer Science
- Vol. 26 (3) , 585-602
A double window state observer for detection and isolation of abrupt changes in parameters
The paper presents a new method for diagnosis of a process fault which takes the form of an abrupt change in some real parameter of a time-continuous linear system. The abrupt fault in the process real parameter is reflected in step changes in many parameters of the input/output model as well as in step changes in canonical state variables of the system. Detection of these state changes will enable localization of the faulty parameter in the system. For detecting state changes, a special type of exact state observer will be used. The canonical state will be represented by the derivatives of the measured output signal. Hence the exact state observer will play the role of virtual sensors for reconstruction of the derivatives of the output signal. For designing the exact state observer, the model parameters before and after the moment of fault occurrence must be known. To this end, a special identification method with modulating functions will be used. A novel concept presented in this paper concerns the structure of the observer. It will take the form of a double moving window observer which consists of two signal processing windows, each of width T. These windows are coupled to each other with a common edge. The right-hand side edge of the left-side moving window in the interval [t − 2T, t − T ] is connected to the left-hand side edge of the right-side window which operates in the interval [t − T, t]. The double observer uses different measurements of input/output signals in both the windows, and for each current time t simultaneously reconstructs two values of the state—the final value of the state in the left-side window zT (t − T) and the initial value of the state z 0(t − T) in the right-side window. If the process parameters are constant, the values of both the states on the common joint edge are the same. If an abrupt change (fault) in some parameter at the moment tA = t − T occurs in the system, then step changes in some variables of the canonical state vector will also occur and the difference between the states will be detected. This will enable localization of the faulty parameter in the system.
- 1 September 2016
- Published by University of Zielona Góra, Poland in International Journal of Applied Mathematics and Computer Science
- Vol. 26 (3) , 585-602
Open AccessA double window state observer for detection and isolation of abrupt changes in parameters
The paper presents a new method for diagnosis of a process fault which takes the form of an abrupt change in some real parameter of a time-continuous linear system. The abrupt fault in the process real parameter is reflected in step changes in many parameters of the input/output model as well as in step changes in canonical state variables of the system. Detection of these state changes will enable localization of the faulty parameter in the system. For detecting state changes, a special type of exact state observer will be used. The canonical state will be represented by the derivatives of the measured output signal. Hence the exact state observer will play the role of virtual sensors for reconstruction of the derivatives of the output signal. For designing the exact state observer, the model parameters before and after the moment of fault occurrence must be known. To this end, a special identification method with modulating functions will be used. A novel concept presented in this paper concerns the structure of the observer. It will take the form of a double moving window observer which consists of two signal processing windows, each of width T. These windows are coupled to each other with a common edge. The right-hand side edge of the left-side moving window in the interval [t − 2T, t − T ] is connected to the left-hand side edge of the right-side window which operates in the interval [t − T, t]. The double observer uses different measurements of input/output signals in both the windows, and for each current time t simultaneously reconstructs two values of the state—the final value of the state in the left-side window zT (t − T) and the initial value of the state z 0(t − T) in the right-side window. If the process parameters are constant, the values of both the states on the common joint edge are the same. If an abrupt change (fault) in some parameter at the moment tA = t − T occurs in the system, then step changes in some variables of the canonical state vector will also occur and the difference between the states will be detected. This will enable localization of the faulty parameter in the system.
- 1 January 2006
- Published by INSTICC
- p. 201-204
THE USE OF MODULATING FUNCTIONS FOR IDENTIFICATION OF CONTINUOUS SYSTEMS WITH TIME-VARYING PARAMETERS
- 1 January 2006
- Published by INSTICC
- p. 201-204
THE USE OF MODULATING FUNCTIONS FOR IDENTIFICATION OF CONTINUOUS SYSTEMS WITH TIME-VARYING PARAMETERS