NANora. A. Abdallah

Nora. A. Abdallah

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nora. A. Abdallah has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Fawzia A. Ibrahim

    Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy Mansoura University Mansoura Egypt

    9 shared publications
  • Amina M. El-Brashy

    Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt

    8 shared publications
  • Manar M. Tolba

    Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt

    6 shared publications
  • Mona E. Fathy

    Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt

    6 shared publications
  • Mohamed I. El-Awady

    Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura 35516, Egypt

    4 shared publications
  • Fawzia A. Ibrahim

    Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, Egypt

    3 shared publications

Latest Publications

  • Open Access

    Green spectrophotometric methods for the determination of metformin–curcumin combination: ICH validation and preliminary bioanalytical applications

    by Amal A. El-Masry, Dina T. El-Sherbiny, Nora A. Abdallah

    The combined therapeutic use of Metformin and Curcumin has attracted growing interest in diabetes management, owing to metformin’s glucose-lowering effect and curcumin’s antioxidant and anti-inflammatory activities. This clinical relevance necessitates reliable analytical methods for their simultaneous determination. In this study, three simple, selective, and cost-effective complementary spectrophotometric methods were developed and validated for the analysis of metformin and curcumin in dosage forms and human plasma. A zero-order spectrophotometric method enabled the selective determination of curcumin, while a first-derivative method allowed simultaneous quantification of both analytes with improved spectral resolution. A ratio subtraction method was also established for selective metformin determination in the presence of curcumin, effectively resolving spectral overlap without prior separation. All methods exhibited excellent linearity over the concentration range of 0.5–20.0 µg mL − 1 ( r ≥ 0.999). The methods also demonstrated high analytical sensitivity, with limits of detection and quantitation ranging from 0.08 to 0.15 µg mL − 1 and 0.23 to 0.45 µg mL − 1 , respectively. Validation following ICH guidelines confirmed satisfactory accuracy, precision, and selectivity. Statistical comparison with reference methods using Student’s t-test and F-test showed no significant differences at the 95% confidence level. The proposed methods were successfully applied to the determination of both drugs in raw materials, metformin pharmaceutical formulations spiked with curcumin, and spiked human plasma, demonstrating excellent accuracy and precision, with recoveries ranging from 98.73% to 101.06% and RSD values not exceeding 1.50%. Greenness assessment demonstrated environmental compatibility, supporting their use as sustainable analytical tools for routine quality control and bioanalytical applications.

  • Nature‐Driven N,S‐Highly Fluorescent Carbon Dots as Turn‐Off Fluorescent Nanosensors for Determination of Tinidazole in Pharmaceutical Dosage Form and in Biological Fluid

    by Ahmed A. Shokeer, Fawzia A. Ibrahim, Nora A. Abdallah

    This work represents a highly sensitive, low‐cost, and eco‐friendly method that relies on using onion and lemon juices, which are easily available materials. It depends on the synthesis of highly fluorescent carbon dots (λex/em 350.0–430.0 nm) using a one‐step microwave‐assisted carbonization method. Characterization of the formed carbon dots was performed using transmission electron microscopy (TEM), Fourier transform infrared (FTIR), Zeta potential analysis, fluorescence spectroscopy UV–Visible spectroscopy, and X‐ray photoelectron spectroscopy (XPS). The formed carbon dots appeared to be spherical in shape, with a 2.0‐ to 3.5‐nm average particle size. The synthesized carbon dots were used for the determination of tinidazole by static fluorescence quenching mechanism and inner filter effect. The quenching effect on the synthesized carbon dots' fluorescence signal was utilized for the determination of tinidazole in pure form in concentration samples (2.0–30 μM) with a %recovery of 99.86 ± 1.38 in pure form, 100.0 ± 1.67 in tablet and 99.56 ± 4.18 in urine. The validity of the method was assessed according to the recommendations of the International Conference on Harmonization. The greenness of the method was evaluated using different greenness assessment tools. The proposed probe is eco‐friendly due to using water as the only solvent in the absence of other organic solvents.


  • Probing the Drug–Protein Interactions Using Multi‐Spectroscopic Approaches: Characterizing the Interactions of Chromium Picolinate With Bovine Serum Albumin

    by Nora A. Abdallah, Heba Elmansi, Shahenda M. El‐Messery, Fathalla Belal

    The binding behavior of the antioxidant supplement chromium picolinate (CPN) with bovine serum albumin (BSA) was examined under simulated physiological conditions using a variety of spectroscopic techniques, including Fourier transform infrared (FTIR), fluorescence, and UV–visible absorption spectroscopy, complemented by molecular docking analyses. Fluorescence quenching studies revealed that the formation of the BSA–CPN complex resulted in the quenching of HSA's intrinsic fluorescence. A portion of the quenching arises from the inner filter effect (IFE), while the remainder occurs through a dynamic mechanism, with a binding affinity of 3.47 × 10 7 L mol −1 at 298 K. Thermodynamic analysis via the van't Hoff equation provided key parameters, with an enthalpy change (ΔH°) of −238.89 kJ mol −1 and an entropy change (ΔS°) of −671.146 J mol −1 K −1 . These values, along with spectral data, suggested that the stability of the BSA–CPN complex was primarily governed by hydrogen bonding and van der Waals forces. Further structural analysis using FTIR and UV–vis spectroscopy pointed out that CPN binding made conformational changes in BSA, particularly altering its secondary structure due to interactions with hydrophobic pocket residues. Competitive binding assays with site‐specific probes suggested that CPN is likely binding to BSA at a location analogous to Site I.


  • Open Access

    Greenness, blueness, and whiteness evaluation of a quantitative nuclear magnetic resonance procedure for concurrent assay of aspirin and omeprazole in their single and fixed-dose combined tablets

    by Amal A. El-Masry, Abdallah M. Zeid, Nora A. Abdallah

    The Food and Drug Administration recently approved a fixed dose combination of aspirin and omeprazole that has been introduced for the treatment of gastrointestinal disorders, as it reduces the risk of upper gastrointestinal and cardiovascular adverse events in aspirin-treated patients. Therefore, an optimized eco-friendly, simple, fast, and precise quantitative nuclear magnetic resonance spectroscopy technique was presented for the concurrent estimation of that mixture in their single and combined dosage forms. The quantitative nuclear magnetic resonance spectroscopy concurrent estimation of both drugs was achieved using phloroglucinol as the internal standard and dimethyl sulfoxide as a deuterated solvent. An ideal set of acquisition parameters was determined to be 128 scans, 10 s relaxation latency, and 90° pulse angle. The selected quantitative signal of aspirin was the doublet of doublet signal appeared at 7.945 ppm, while that of omeprazole was the singlet signal at 8.18 ppm. The singlet signal at 5.69 ppm was selected for the internal standard. The spectra were subjected to integration, baseline correction, and auto phase correction. The developed quantitative proton nuclear magnetic resonance spectroscopy method was found to be rectilinear over the range of 0.05–4.0 mg mL−1 for both drugs. The detecting and quantifying limits for both drugs were approximately 0.01 and 0.03 mg mL−1, respectively. Neither labelling nor pretreatment steps were needed to assay the studied drugs using our developed quantitative nuclear magnetic resonance spectroscopy method. The proposed nuclear magnetic resonance spectroscopy approach was effectively evaluated in terms of linearity (r = 0.9999), accuracy, and precision (%RSD < 1.08). Furthermore, the suggested technique was investigated to analyze the studied drugs in their single and combined dosages. This work enables clinicians to simultaneously monitor aspirin and omeprazole levels in both single and fixed-dose combination tablets, ensuring precise dosing and effective treatment management. For patients, it supports safer therapy by reducing the risks associated with improper dosing or drug interactions in combination therapies. After evaluating the method's greenness, whiteness and blueness, it was determined that the suggested approach was environmentally friendly. The suggested approach was compared with the previously reported methods from both an analytical and eco-friendly perspective.


  • Open Access

    Hydro-organic mobile phase and factorial design application to attain green HPLC method for simultaneous assay of paracetamol and dantrolene sodium in combined capsules

    by Nora A. Abdallah, Manar M. Tolba, Amina M. El-Brashy, Fawzia A. Ibrahim, Mona E. Fathy

    The greenness of any analytical method has become a very important aspect of a good analytical method. However, most chromatographic methods depend on the usage of relatively large amounts of lethal and un-decaying chemicals and solvents. So, a green approach based on the full factorial design was employed to develop a simple and rapid HPLC technique for concurrent determination of paracetamol and dantrolene sodium in their combined capsules. Both drugs are highly recommended to be administered together in patients with severe musculoskeletal disorders. Avoiding the routine methodology and resorting to the modern technology represented in the usage of experimental design allows rapid determination of the studied drugs using the optimum quantity of chemicals to avoid any waste of resources. Simultaneous separation of a binary mixture of paracetamol and dantrolene sodium was accomplished using a reversed phase Hypersil C18 column using an eco-friendly isocratic eluent. The used mobile phase consisted simply of ethanol: water (40:60, v/v). Orthophosphoric acid was used to adjust the pH of the mobile phase to 4.5. Triethanolamine (0.2%) was added aiming to reduce the peak tailing. The assay was completed within less than 6 min adopting 0.8 mL/min as a flow rate. The detection was carried out using a UV-detector at 290 nm. The suggested technique shows a linear correlation over concentration ranges of 1.0–200 and 1.0–40 µg/mL for paracetamol and dantrolene sodium, respectively. The suggested technique allowed the simultaneous analysis of the two co-formulated drugs in their synthetic mixture and combined capsule. The suggested technique is considered a greener substitute for the other reported HPLC techniques through the usage of safer solvents and chemicals, along with decreasing both waste output and analysis time. The method is accurate with recoveries between 97.85 and 101.27%, precise, as %RSD for the intraday and interday precision were between 0.39 and 1.72% and very sensitive with limits of detection (LOD)’s 0.15 and 0.18 µg/ml and limits of quantification (LOQ)’s 0.48 and 0.61 µg/ml for paracetamol and dantrolene sodium, respectively. The method greenness was ensured through its assessment by four greenness metrics. It is also validated following the International Conference on Harmonization Guidelines. The recommended technique could be a good alternative to traditional methods in the routine quality control analysis of the studied drugs due to its minimum harm to the planet or human beings.


  • Open Access

    Micellar eco-friendly HPLC method for simultaneous analysis of ternary combination of aspirin, atorvastatin and ramipril: application to content uniformity testing

    by Nora A. Abdallah, Amina M. El-Brashy, Fawzia A. Ibrahim, Mohamed I. El-Awady

    Background: Cardiovascular disease medications such as aspirin (ASP), statins like atorvastatin (ATR), and blood pressure-lowering drugs including ACE inhibitors like ramipril (RAM) have been included in the World Health Organization (WHO) Essential Medicines List (EML) for many years. Therefore, there is a strong demand to develop a simple, rapid, and sensitive analytical method that can detect and quantitate the ternary mixture of these analytes in pharmaceutical preparations in a short run time. Lately, the analytical community focused on eliminating or reducing hazardous chemicals and solvents usage. Results: A green, fast, selective, and cost-effective micellar HPLC method was established and validated for the concurrent determination of ternary combination of ASP, ATR, and RAM in the pure form and pharmaceutical preparations. Resolution of the three drugs was achieved by using a monolithic column and a micellar mobile phase consists of 0.3% triethylamine (TEA) in 90: 10 an aqueous solution of 0.12 M sodium dodecyl sulfate (SDS): n-propanol, (v/v). The pH was adjusted to 2.5 using orthophosphoric acid and a flow rate of 1.5 mL/min. was applied. To ensure method reproducibility, Valsartan (VAL) was utilized as an internal standard (IS). The UV detection of the studied drugs was performed at 210 nm. Good linearity for the three drugs was obtained over the concentration ranges of 1.0-200.0 mg/mL, 0.5-200.0 mg/mL, and 5.0-100.0 mg/mL with correlation coefficients of 0.9998,0.9999 and 0.9999 for ASP, ATR, and RAM respectively. The method sensitivity was revealed by the relatively small values of limits of detection (LOD) (0.19, 0.13 and 0.30 mg/mL) and limits of quantitation (LOQ) (0.63, 0.44 and 0.99 mg/mL) for ASP, ATR, and RAM, respectively. The retention times of ASP, ATR and RAM were 1.50, 2.3 and 4.3 min., respectively. Conclusions: The suggested technique was employed for the analysis of the three drugs in their prepared tablets maintaining the recommended pharmaceutical ratio without any interference from excipients. The method was further extended to content uniformity testing of RAM. The results were validated according to international council for harmonisation (ICH) guidelines.


  • Open Access

    Green Constant-wavelength Concurrent Selective Fluorescence Method for Assay of Ibuprofen and Chlorzoxazone in Presence of Chlorzoxazone Degradation Product

    by Nora A. Abdallah, Mona E. Fathy, Manar M. Tolba, Amina M. El-Brashy, Fawzia A. Ibrahim

    Lower back pain is a universal dilemma leaving a negative effect on both health and life quality. It was found that a fixed dose combination of chlorzoxazone and ibuprofen gave a higher efficiency than analgesic alone in treatment of acute lower back pain. Based on the significant benefit of that combination, a green, sensitive, rapid, direct, and cost-effective method is created for concurrent determination of ibuprofen and chlorzoxazone in presence of 2-amino para chlorophenol (a synthetic precursor and potential impurity of chlorzoxazone) adopting the synchronous spectrofluorimetric technique. Synchronous spectrofluorimetric technique is adopted to avoid the highly overlapped native spectra of both drugs. The synchronous spectrofluorometric method was applied at Δλ = 50 nm, ibuprofen was measured at 227 nm while chlorzoxazone was measured at 282 nm with no hindering from one to another. The various experimental variables affecting the performance of the suggested technique were explored and adjusted. The suggested technique showed good linearity from 0.02 to 0.6 and 0.1 to 5.0 µg/mL for ibuprofen and chlorzoxazone, respectively. The produced detection limits were 0.27 × 10–3and 0.03, while the quantitation limits were 0.82 × 10–3and 0.09 µg/mL for ibuprofen and chlorzoxazone, respectively. The suggested approach was successfully applied for the analysis of the studied drugs in the synthetic mixture, different pharmaceutical preparations, and spiked human plasma. The suggested technique was validated with respect to the International Council of Harmonization (ICH) recommendations. The suggested technique was found to be simpler and greener with lower cost compared to the earlier reported methods which required complicated techniques, longer time of analysis, and less safe solvents and reagents. Green profile assessment for the developed method compared with the reported spectrofluorometric method was performed using four assessment tools. These tools confirmed that the recommended technique attained the most possible green parameters, so it could be used as a greener option in routine quality control for analyzing the two drugs in genuine form and pharmaceutical preparations.