Magdalena Bodnar-Broniarczyk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Magdalena Bodnar-Broniarczyk has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Dorota Marszałek
Department of Drug Chemistry, Medical University of Warsaw, Banacha 1, 02-097 Warsaw, Poland
1 shared publication - Karola Warzyszyńska
Department of General and Transplantation Surgery, Medical University of Warsaw, Warsaw, Poland
1 shared publication - Katarzyna Czerwinska
Department of Transplantation Medicine, Nephrology and Internal Diseases, Medical University of Warsaw, Nowogrodzka 59, 02-006 Warsaw, Poland
1 shared publication - Maciej Kosieradzki
Department of General and Transplantation Surgery, Medical University of Warsaw, Warsaw, Poland
1 shared publication - Natalia Dziewa
Department of General and Transplant Surgery, Medical University of Warsaw
1 shared publication - Tomasz Pawiński
Department of Drug Chemistry, Pharmaceutical and Biomedical Analysis, Medical University of Warsaw, Banacha 1, 02-097 Warsaw, Poland
1 shared publication
Latest Publications
- Open Access
- 12 March 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (3) , 632
Development and Validation of the New Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Unbound Tacrolimus in the Plasma Ultrafiltrate of Transplant Recipients
(1) Background: Only unbound tacrolimus particles are considered to be active and capable of crossing cellular membranes. Thus, the free-drug concentration might be better associated with clinical effects than the total drug concentration used for dosage adjustment. We propose a new, fully validated online liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for unbound tacrolimus concentration measurement. (2) Methods: The determination of the unbound tacrolimus concentration in plasma ultrafiltrate was performed with the Nexera LC system with LCMS-8050 triple quadrupole MS using ascomycin as an internal standard. Chromatographic separation was made using a HypurityC18 analytical column. MS/MS with electrospray ionization and positive-ion multiple-reaction monitoring was used. The unbound tacrolimus level was determined in 36 patients after solid organ transplantation (n = 140). (3) Results: A lower limit of quantification 0.1 pg/mL was achieved, and the assay was linear between 0.1 and 20 pg/mL (R2 = 0.991). No carry-over was detected. The within-run and between-run accuracies ranged between 97.8–109.7% and 98.3–107.1%, while the greatest imprecision was 10.6% and 10.7%, respectively. Free tacrolimus in patients’ plasma ultrafiltrate varied between 0.06 and 18.25 pg/mL (median: 0.98 pg/mL). (4) Conclusions: The proposed method can be easily implemented. The significance of the unbound tacrolimus concentration needs to be investigated. This may facilitate the individualization and optimization of immunosuppressive treatment.
- 12 March 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (3) , 632
Open AccessDevelopment and Validation of the New Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Unbound Tacrolimus in the Plasma Ultrafiltrate of Transplant Recipients
(1) Background: Only unbound tacrolimus particles are considered to be active and capable of crossing cellular membranes. Thus, the free-drug concentration might be better associated with clinical effects than the total drug concentration used for dosage adjustment. We propose a new, fully validated online liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for unbound tacrolimus concentration measurement. (2) Methods: The determination of the unbound tacrolimus concentration in plasma ultrafiltrate was performed with the Nexera LC system with LCMS-8050 triple quadrupole MS using ascomycin as an internal standard. Chromatographic separation was made using a HypurityC18 analytical column. MS/MS with electrospray ionization and positive-ion multiple-reaction monitoring was used. The unbound tacrolimus level was determined in 36 patients after solid organ transplantation (n = 140). (3) Results: A lower limit of quantification 0.1 pg/mL was achieved, and the assay was linear between 0.1 and 20 pg/mL (R2 = 0.991). No carry-over was detected. The within-run and between-run accuracies ranged between 97.8–109.7% and 98.3–107.1%, while the greatest imprecision was 10.6% and 10.7%, respectively. Free tacrolimus in patients’ plasma ultrafiltrate varied between 0.06 and 18.25 pg/mL (median: 0.98 pg/mL). (4) Conclusions: The proposed method can be easily implemented. The significance of the unbound tacrolimus concentration needs to be investigated. This may facilitate the individualization and optimization of immunosuppressive treatment.