Hui Min Tay
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hui Min Tay has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Han Wei Hou
Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore 308232, Singapore
11 shared publications Hong Boon Ong
School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798
4 shared publicationsMegha Upadya
School of Biological Sciences, Nanyang Technological University, Singapore 637551
3 shared publications- Rinkoo Dalan
Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, Singapore
3 shared publications Sheng Yuan Leong
School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Blk N3, Level 2, Room 86 (N3-02c-86), 639798, Singapore
3 shared publicationsChayakorn Petchakup
School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore 639798, Singapore
2 shared publications
Latest Publications
- 16 September 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (18) , 4951-4969
Label-free microfluidic small-volume blood processing for analysis of platelet activation and neutrophil–platelet aggregates
A label-free Dean Flow Fractionation (DFF) platform enables gentle dual isolation of platelets and leukocytes from 100 μL whole blood to accelerate clinical and in vivo studies of platelet dysfunction.
- 16 September 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (18) , 4951-4969
Label-free microfluidic small-volume blood processing for analysis of platelet activation and neutrophil–platelet aggregates
A label-free Dean Flow Fractionation (DFF) platform enables gentle dual isolation of platelets and leukocytes from 100 μL whole blood to accelerate clinical and in vivo studies of platelet dysfunction.
- Open Access
- 28 November 2025
- Published by Wiley in Advanced Science
- Vol. 13 (9) , e16021
Label‐Free Leukocyte Biophysical Profiling Using Impedance‐Deformability Cytometry for Rapid Cardiovascular Risk Stratification
Type 2 diabetes mellitus (T2DM) presents a global health burden with cardiovascular disease (CVD) as its leading cause of mortality. A rapid clinical‐adaptable microfluidic workflow for label‐free CVD risk profiling based on neutrophil biophysical abnormalities is developed. This high‐throughput single cell (>1,000 cells min −1 ) “electro‐mechano‐phenotyping” method integrates Uniform Manifold Approximation and Projection analysis to assess leukocyte biophysical changes (size, deformability, and impedance properties) linked to inflammation, thrombosis, and hyperglycemia in vitro, and in diabetic and diabetic atherosclerosis‐prone mouse models. In a clinical study of healthy, pre‐diabetes, diabetes, and diabetic patients with CVD (DM‐CVD) subjects ( n = 10–11 per group), DM‐CVD neutrophils exhibited a distinct impedance signature and pro‐inflammatory transcriptomic profile marked by cytoskeletal dysregulation and altered RhoA signaling. Principal component analysis (area under the curve = 0.971) identifies individuals with vascular dysfunction exhibiting increased carotid intima‐media thickness and reduced reactive hyperemia index. These findings support impedance‐based neutrophil profiling as a promising, cost‐effective strategy for cardiovascular risk stratification in T2DM.
- 28 November 2025
- Published by Wiley in Advanced Science
- Vol. 13 (9) , e16021
Open AccessLabel‐Free Leukocyte Biophysical Profiling Using Impedance‐Deformability Cytometry for Rapid Cardiovascular Risk Stratification
Type 2 diabetes mellitus (T2DM) presents a global health burden with cardiovascular disease (CVD) as its leading cause of mortality. A rapid clinical‐adaptable microfluidic workflow for label‐free CVD risk profiling based on neutrophil biophysical abnormalities is developed. This high‐throughput single cell (>1,000 cells min −1 ) “electro‐mechano‐phenotyping” method integrates Uniform Manifold Approximation and Projection analysis to assess leukocyte biophysical changes (size, deformability, and impedance properties) linked to inflammation, thrombosis, and hyperglycemia in vitro, and in diabetic and diabetic atherosclerosis‐prone mouse models. In a clinical study of healthy, pre‐diabetes, diabetes, and diabetic patients with CVD (DM‐CVD) subjects ( n = 10–11 per group), DM‐CVD neutrophils exhibited a distinct impedance signature and pro‐inflammatory transcriptomic profile marked by cytoskeletal dysregulation and altered RhoA signaling. Principal component analysis (area under the curve = 0.971) identifies individuals with vascular dysfunction exhibiting increased carotid intima‐media thickness and reduced reactive hyperemia index. These findings support impedance‐based neutrophil profiling as a promising, cost‐effective strategy for cardiovascular risk stratification in T2DM.
- 13 February 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (8) , 6623-6637
High-Throughput Microfluidic Extraction of Platelet-free Plasma for MicroRNA and Extracellular Vesicle Analysis
Cell-free RNAs and extracellular vesicles (EVs) are valuable biomarkers in liquid biopsies, but they are prone to preanalytical variabilities such as nonstandardized centrifugation or ex vivo blood degradation. Herein, we report a high-throughput and label-free inertial microfluidic device (ExoArc) for isolation of platelet-free plasma from blood for RNA and EV analysis. Unlike conventional inertial microfluidic devices widely used for cell sorting, a submicrometer size cutoff (500 nm) was achieved which completely removed all leukocytes, RBCs, platelets, and cellular debris based on differential lateral migration induced by Dean vortices. The single-step operation also reduced platelet-associated miRNAs (∼2-fold) compared to centrifugation. We clinically validated ExoArc for plasma miRNA profiling (39 samples) and identified a 7-miRNA panel that detects non-small cell lung cancer with ∼90% sensitivity. ExoArc was also coupled with size exclusion chromatography (SEC) to isolate EVs within 50 min with ∼10-fold higher yield than ultracentrifugation. As a proof-of-concept for EV-based transcriptomics analysis, we performed miRNA analysis in healthy and type 2 diabetes mellitus (T2DM) subjects (n = 3 per group) by coupling ExoArc and ExoArc+SEC with quantitative polymerase chain reaction (RT-qPCR) assay. Among 293 miRNAs detected, plasmas and EVs showed distinct differentially expressed miRNAs in T2DM subjects. We further demonstrated automated in-line EV sorting from low volume culture media for continuous EV monitoring. Overall, the developed ExoArc offers a convenient centrifugation-free workflow to automate plasma and EV isolation for point-of-care diagnostics and quality control in EV manufacturing.
- 13 February 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (8) , 6623-6637
High-Throughput Microfluidic Extraction of Platelet-free Plasma for MicroRNA and Extracellular Vesicle Analysis
Cell-free RNAs and extracellular vesicles (EVs) are valuable biomarkers in liquid biopsies, but they are prone to preanalytical variabilities such as nonstandardized centrifugation or ex vivo blood degradation. Herein, we report a high-throughput and label-free inertial microfluidic device (ExoArc) for isolation of platelet-free plasma from blood for RNA and EV analysis. Unlike conventional inertial microfluidic devices widely used for cell sorting, a submicrometer size cutoff (500 nm) was achieved which completely removed all leukocytes, RBCs, platelets, and cellular debris based on differential lateral migration induced by Dean vortices. The single-step operation also reduced platelet-associated miRNAs (∼2-fold) compared to centrifugation. We clinically validated ExoArc for plasma miRNA profiling (39 samples) and identified a 7-miRNA panel that detects non-small cell lung cancer with ∼90% sensitivity. ExoArc was also coupled with size exclusion chromatography (SEC) to isolate EVs within 50 min with ∼10-fold higher yield than ultracentrifugation. As a proof-of-concept for EV-based transcriptomics analysis, we performed miRNA analysis in healthy and type 2 diabetes mellitus (T2DM) subjects (n = 3 per group) by coupling ExoArc and ExoArc+SEC with quantitative polymerase chain reaction (RT-qPCR) assay. Among 293 miRNAs detected, plasmas and EVs showed distinct differentially expressed miRNAs in T2DM subjects. We further demonstrated automated in-line EV sorting from low volume culture media for continuous EV monitoring. Overall, the developed ExoArc offers a convenient centrifugation-free workflow to automate plasma and EV isolation for point-of-care diagnostics and quality control in EV manufacturing.
- 21 July 2023
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (8) , 3136-3145
Rapid Screening of Urinary Tract Infection Using Microfluidic Inertial-Impedance Cytometry
Urinary tract infection (UTI) diagnosis based on urine culture for bacteriuria analysis is time-consuming and often leads to wastage of hospital resources due to false-positive UTI cases. Direct cellular phenotyping (e.g., RBCs, neutrophils, epithelial cells) of urine samples remains a technical challenge as low cell concentrations, and urine characteristics (conductivities, pH, microbes) can affect the accuracy of cell measurements. In this work, we report a microfluidic inertial-impedance cytometry technique for label-free rapid (n = 20) and UTI patients (n = 20). A significant increase in cell count was observed in UTI samples, and biophysical parameters were used to develop a UTI classifier with an area under the receiver operating characteristic curve of 0.84. Overall, the developed platform facilitates rapid culture-free urine screening which can be further developed to assess disease severity in UTI and other urologic diseases based on neutrophil electrical signatures.
- 21 July 2023
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 8 (8) , 3136-3145
Rapid Screening of Urinary Tract Infection Using Microfluidic Inertial-Impedance Cytometry
Urinary tract infection (UTI) diagnosis based on urine culture for bacteriuria analysis is time-consuming and often leads to wastage of hospital resources due to false-positive UTI cases. Direct cellular phenotyping (e.g., RBCs, neutrophils, epithelial cells) of urine samples remains a technical challenge as low cell concentrations, and urine characteristics (conductivities, pH, microbes) can affect the accuracy of cell measurements. In this work, we report a microfluidic inertial-impedance cytometry technique for label-free rapid (n = 20) and UTI patients (n = 20). A significant increase in cell count was observed in UTI samples, and biophysical parameters were used to develop a UTI classifier with an area under the receiver operating characteristic curve of 0.84. Overall, the developed platform facilitates rapid culture-free urine screening which can be further developed to assess disease severity in UTI and other urologic diseases based on neutrophil electrical signatures.
- Top Cited PapersOpen Access
- 19 January 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (5) , 1226-1257
Label-free microfluidic cell sorting and detection for rapid blood analysis
This review focuses on recent microfluidic technologies for label-free blood cell separation, detection and coupling with machine learning approaches.
- 19 January 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (5) , 1226-1257
Top Cited PapersOpen AccessLabel-free microfluidic cell sorting and detection for rapid blood analysis
This review focuses on recent microfluidic technologies for label-free blood cell separation, detection and coupling with machine learning approaches.
- 8 December 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (3) , 410-420
Studying the efficacy of antiplatelet drugs on atherosclerosis by optofluidic imaging on a chip
Vascular stenosis caused by atherosclerosis instigates activation and aggregation of platelets, eventually resulting in thrombus formation. Although antiplatelet drugs are commonly used to inhibit platelet activation and aggregation, they unfortunately cannot prevent recurrent thrombotic events in patients with atherosclerosis. This is partially due to the limited understanding of the efficacy of antiplatelet drugs in the complex hemodynamic environment of vascular stenosis. Conventional methods for evaluating the efficacy of antiplatelet drugs under stenosis either fail to simulate the hemodynamic environment of vascular stenosis characterized by high shear stress and recirculatory flow or lack spatial resolution in their analytical techniques to statistically identify and characterize platelet aggregates. Here we propose and experimentally demonstrate a method comprising an in vitro 3D stenosis microfluidic chip and an optical time-stretch quantitative phase imaging system for studying the efficacy of antiplatelet drugs under stenosis. Our method simulates the atherogenic flow environment of vascular stenosis while enabling high-resolution and statistical analysis of platelet aggregates. Using our method, we distinguished the efficacy of three antiplatelet drugs, acetylsalicylic acid (ASA), cangrelor, and eptifibatide, for inhibiting platelet aggregation induced by stenosis. Specifically, ASA failed to inhibit stenosis-induced platelet aggregation, while eptifibatide and cangrelor showed high and moderate efficacy, respectively. Furthermore, we demonstrated that the drugs tested also differed in their efficacy for inhibiting platelet aggregation synergistically induced by stenosis and agonists (e.g., adenosine diphosphate, and collagen). Taken together, our method is an effective tool for investigating the efficacy of antiplatelet drugs under vascular stenosis, which could assist the development of optimal pharmacologic strategies for patients with atherosclerosis.
- 8 December 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (3) , 410-420
Studying the efficacy of antiplatelet drugs on atherosclerosis by optofluidic imaging on a chip
Vascular stenosis caused by atherosclerosis instigates activation and aggregation of platelets, eventually resulting in thrombus formation. Although antiplatelet drugs are commonly used to inhibit platelet activation and aggregation, they unfortunately cannot prevent recurrent thrombotic events in patients with atherosclerosis. This is partially due to the limited understanding of the efficacy of antiplatelet drugs in the complex hemodynamic environment of vascular stenosis. Conventional methods for evaluating the efficacy of antiplatelet drugs under stenosis either fail to simulate the hemodynamic environment of vascular stenosis characterized by high shear stress and recirculatory flow or lack spatial resolution in their analytical techniques to statistically identify and characterize platelet aggregates. Here we propose and experimentally demonstrate a method comprising an in vitro 3D stenosis microfluidic chip and an optical time-stretch quantitative phase imaging system for studying the efficacy of antiplatelet drugs under stenosis. Our method simulates the atherogenic flow environment of vascular stenosis while enabling high-resolution and statistical analysis of platelet aggregates. Using our method, we distinguished the efficacy of three antiplatelet drugs, acetylsalicylic acid (ASA), cangrelor, and eptifibatide, for inhibiting platelet aggregation induced by stenosis. Specifically, ASA failed to inhibit stenosis-induced platelet aggregation, while eptifibatide and cangrelor showed high and moderate efficacy, respectively. Furthermore, we demonstrated that the drugs tested also differed in their efficacy for inhibiting platelet aggregation synergistically induced by stenosis and agonists (e.g., adenosine diphosphate, and collagen). Taken together, our method is an effective tool for investigating the efficacy of antiplatelet drugs under vascular stenosis, which could assist the development of optimal pharmacologic strategies for patients with atherosclerosis.
- 1 July 2021
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 339
Label-free quantitative lymphocyte activation profiling using microfluidic impedance cytometry
- 1 July 2021
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 339
Label-free quantitative lymphocyte activation profiling using microfluidic impedance cytometry
- 24 May 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (13) , 2511-2523
Direct isolation of circulating extracellular vesicles from blood for vascular risk profiling in type 2 diabetes mellitus
Extracellular vesicles (EVs) are key mediators of communication among cells, and clinical utilities of EVs-based biomarkers remain limited due to difficulties in isolating EVs from whole blood reliably. We report a novel inertial-based microfluidic platform for direct isolation of nanoscale EVs (exosomes, 50 to 200 nm) and medium-sized EVs (microvesicles, 200 nm to 1 μm) from blood with high efficiency (three-fold increase in EV yield compared to ultracentrifugation). In a pilot clinical study of healthy (n = 5) and type 2 diabetes mellitus (T2DM, n = 9) subjects, we detected higher EV levels in T2DM patients (P < 0.05), and identified a subset of “high-risk” T2DM subjects with abnormally high (∼10-fold to 50-fold) amounts of platelet (CD41a+) or leukocyte-derived (CD45+) EVs. Our in vitro endothelial cell assay further revealed that EVs from “high-risk” T2DM subjects induced significantly higher vascular inflammation (ICAM-1 expression) (P < 0.05) as compared to healthy and non-“high-risk” T2DM subjects, reflecting a pro-inflammatory phenotype. Overall, the EV isolation tool is scalable, and requires less manual labour, cost and processing time. This enables further development of EV-based diagnostics, whereby a combined immunological and functional phenotyping strategy can potentially be used for rapid vascular risk stratification in T2DM.
- 24 May 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (13) , 2511-2523
Direct isolation of circulating extracellular vesicles from blood for vascular risk profiling in type 2 diabetes mellitus
Extracellular vesicles (EVs) are key mediators of communication among cells, and clinical utilities of EVs-based biomarkers remain limited due to difficulties in isolating EVs from whole blood reliably. We report a novel inertial-based microfluidic platform for direct isolation of nanoscale EVs (exosomes, 50 to 200 nm) and medium-sized EVs (microvesicles, 200 nm to 1 μm) from blood with high efficiency (three-fold increase in EV yield compared to ultracentrifugation). In a pilot clinical study of healthy (n = 5) and type 2 diabetes mellitus (T2DM, n = 9) subjects, we detected higher EV levels in T2DM patients (P < 0.05), and identified a subset of “high-risk” T2DM subjects with abnormally high (∼10-fold to 50-fold) amounts of platelet (CD41a+) or leukocyte-derived (CD45+) EVs. Our in vitro endothelial cell assay further revealed that EVs from “high-risk” T2DM subjects induced significantly higher vascular inflammation (ICAM-1 expression) (P < 0.05) as compared to healthy and non-“high-risk” T2DM subjects, reflecting a pro-inflammatory phenotype. Overall, the EV isolation tool is scalable, and requires less manual labour, cost and processing time. This enables further development of EV-based diagnostics, whereby a combined immunological and functional phenotyping strategy can potentially be used for rapid vascular risk stratification in T2DM.
- 14 November 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (24) , 14535-14542
Multiplexed Label-Free Fractionation of Peripheral Blood Mononuclear Cells for Identification of Monocyte–Platelet Aggregates
Monocytes and platelets play key roles in atherosclerosis and thrombosis, and circulating monocyte-platelet aggregates (MPA) in blood have been widely proposed as surrogate biomarkers for cardiovascular risk stratification and monitoring anti-platelet therapies. However, conventional MPA characterization is based on whole blood fixation and flow cytometry analysis which adversely affect cell viability and detection accuracy due to significant leukocyte and platelet contamination. Herein, we introduce a rapid and label-free microfluidic approach for complete size-based fractionation of peripheral blood mononuclear cells (PBMCs) into monocytes, lymphocytes and platelets. The developed biochip enables gentle sorting of intact MPA in the enriched monocytes with efficient depletion of lymphocytes and platelets for accurate MPA quantification. We first compared the developed microfluidic technology (Dean Flow Fractionation, DFF) with standard magnetic negative isolation (MACS), and observed that DFF-sorted monocytes had similar viability, purity and key immune functions (phagocytosis, macrophage differentiation) as MACS-sorted monocytes. As proof-of-concept for diabetes testing, we isolated and characterized monocytes/MPA from a cohort of healthy (n=5) and type 2 diabetes mellitus (T2DM) subjects (n=8) in PBMCs and DFF-sorted monocytes. High speed imaging, immunofluorescence and flow cytometry analysis clearly indicated higher levels of MPA in T2DM patients (P-1) label-free isolation of monocyte/MPA from PBMCs, and can be further developed into a clinical tool for point-of-care cardiovascular risk stratification in metabolic disorders including T2DM.
- 14 November 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (24) , 14535-14542
Multiplexed Label-Free Fractionation of Peripheral Blood Mononuclear Cells for Identification of Monocyte–Platelet Aggregates
Monocytes and platelets play key roles in atherosclerosis and thrombosis, and circulating monocyte-platelet aggregates (MPA) in blood have been widely proposed as surrogate biomarkers for cardiovascular risk stratification and monitoring anti-platelet therapies. However, conventional MPA characterization is based on whole blood fixation and flow cytometry analysis which adversely affect cell viability and detection accuracy due to significant leukocyte and platelet contamination. Herein, we introduce a rapid and label-free microfluidic approach for complete size-based fractionation of peripheral blood mononuclear cells (PBMCs) into monocytes, lymphocytes and platelets. The developed biochip enables gentle sorting of intact MPA in the enriched monocytes with efficient depletion of lymphocytes and platelets for accurate MPA quantification. We first compared the developed microfluidic technology (Dean Flow Fractionation, DFF) with standard magnetic negative isolation (MACS), and observed that DFF-sorted monocytes had similar viability, purity and key immune functions (phagocytosis, macrophage differentiation) as MACS-sorted monocytes. As proof-of-concept for diabetes testing, we isolated and characterized monocytes/MPA from a cohort of healthy (n=5) and type 2 diabetes mellitus (T2DM) subjects (n=8) in PBMCs and DFF-sorted monocytes. High speed imaging, immunofluorescence and flow cytometry analysis clearly indicated higher levels of MPA in T2DM patients (P-1) label-free isolation of monocyte/MPA from PBMCs, and can be further developed into a clinical tool for point-of-care cardiovascular risk stratification in metabolic disorders including T2DM.