Tamás Tóth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tamás Tóth has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Adrienne Németh
Department of Otorhinolaryngology and Head Neck Surgery, Medical School, University of Pécs, Pécs, Hungary
2 shared publicationsImre Gerlinger
Department of Otorhinolaryngology and Head Neck Surgery, Medical School, University of Pécs, Pécs, Hungary
2 shared publications- Imre Gerlinger
Department of Otorhinolaryngology, University of Pecs Medical School, Pecs, Hungary
2 shared publications István Szanyi
Department of Otorhinolaryngology and Head Neck Surgery, Medical School, University of Pécs, Pécs, Hungary
2 shared publications- István Szanyi
Department of Otorhinolaryngology and Head and Neck Surgery, Clinical Center, University of Pécs Medical School, Pécs, Hungary
2 shared publications - Kálmán Rígler
Department of Otorhinolaryngology, University of Pecs Medical School, Pecs, Hungary
2 shared publications
Latest Publications
- Open Access
- 11 July 2026
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 22 (3) , 1-5
Long-Term Hearing Outcomes of NiTiBOND versus SMart Nitinol Prostheses in Stapes Surgery—A Retrospective Cohort Study
BACKGROUND: Perform a statistical analysis of the long-term hearing results for 2 groups after stapedotomy using different heat-memory stapes prostheses. METHODS: A retrospective study of 42 patients who underwent stapedotomy using either NiTiBOND (n=25) or SMart Nitinol (n=17) thermal shape memory prostheses. Statistical differences were assessed with univariate and multivariate analysis. Success was defined as a postoperative air-bone gap (ABG) ≤ 10 dB. A Pvalue < .05 was considered statistically significant. RESULTS: The audiological outcomes were measured at an average of 7.3 and 13.4 years postoperatively for NiTiBOND and Nitinol, respectively. The postoperative ABG was a mean of 5.18 ± 5.59 dB and 4.71 ± 5.02 dB; no statistically significant difference was observed between the groups. Three patients achieving >10 dB postoperative ABG underwent high-resolution computed tomography, but none showed noticeable pathological changes. CONCLUSION: The study demonstrated excellent audiological outcomes with both prostheses and appears to be stable in the long term.
- 11 July 2026
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 22 (3) , 1-5
Open AccessLong-Term Hearing Outcomes of NiTiBOND versus SMart Nitinol Prostheses in Stapes Surgery—A Retrospective Cohort Study
BACKGROUND: Perform a statistical analysis of the long-term hearing results for 2 groups after stapedotomy using different heat-memory stapes prostheses. METHODS: A retrospective study of 42 patients who underwent stapedotomy using either NiTiBOND (n=25) or SMart Nitinol (n=17) thermal shape memory prostheses. Statistical differences were assessed with univariate and multivariate analysis. Success was defined as a postoperative air-bone gap (ABG) ≤ 10 dB. A Pvalue < .05 was considered statistically significant. RESULTS: The audiological outcomes were measured at an average of 7.3 and 13.4 years postoperatively for NiTiBOND and Nitinol, respectively. The postoperative ABG was a mean of 5.18 ± 5.59 dB and 4.71 ± 5.02 dB; no statistically significant difference was observed between the groups. Three patients achieving >10 dB postoperative ABG underwent high-resolution computed tomography, but none showed noticeable pathological changes. CONCLUSION: The study demonstrated excellent audiological outcomes with both prostheses and appears to be stable in the long term.
- 11 July 2026
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 22 (3) , 1-5
Long-Term Hearing Outcomes of NiTiBOND versus SMart Nitinol Prostheses in Stapes Surgery—A Retrospective Cohort Study
BACKGROUND: Perform a statistical analysis of the long-term hearing results for 2 groups after stapedotomy using different heat-memory stapes prostheses. METHODS: A retrospective study of 42 patients who underwent stapedotomy using either NiTiBOND (n=25) or SMart Nitinol (n=17) thermal shape memory prostheses. Statistical differences were assessed with univariate and multivariate analysis. Success was defined as a postoperative air-bone gap (ABG) ≤ 10 dB. A Pvalue < .05 was considered statistically significant. RESULTS: The audiological outcomes were measured at an average of 7.3 and 13.4 years postoperatively for NiTiBOND and Nitinol, respectively. The postoperative ABG was a mean of 5.18 ± 5.59 dB and 4.71 ± 5.02 dB; no statistically significant difference was observed between the groups. Three patients achieving >10 dB postoperative ABG underwent high-resolution computed tomography, but none showed noticeable pathological changes. CONCLUSION: The study demonstrated excellent audiological outcomes with both prostheses and appears to be stable in the long term.
- 11 July 2026
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 22 (3) , 1-5
Long-Term Hearing Outcomes of NiTiBOND versus SMart Nitinol Prostheses in Stapes Surgery—A Retrospective Cohort Study
BACKGROUND: Perform a statistical analysis of the long-term hearing results for 2 groups after stapedotomy using different heat-memory stapes prostheses. METHODS: A retrospective study of 42 patients who underwent stapedotomy using either NiTiBOND (n=25) or SMart Nitinol (n=17) thermal shape memory prostheses. Statistical differences were assessed with univariate and multivariate analysis. Success was defined as a postoperative air-bone gap (ABG) ≤ 10 dB. A Pvalue < .05 was considered statistically significant. RESULTS: The audiological outcomes were measured at an average of 7.3 and 13.4 years postoperatively for NiTiBOND and Nitinol, respectively. The postoperative ABG was a mean of 5.18 ± 5.59 dB and 4.71 ± 5.02 dB; no statistically significant difference was observed between the groups. Three patients achieving >10 dB postoperative ABG underwent high-resolution computed tomography, but none showed noticeable pathological changes. CONCLUSION: The study demonstrated excellent audiological outcomes with both prostheses and appears to be stable in the long term.
- Open Access
- 3 May 2023
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 280 (11) , 4851-4859
Matching the pitch perception of the cochlear implanted ear with the contralateral ear in patients with single-sided deafness: a novel approach
Purpose: Single-sided deaf patients following cochlear implantation often compare the sound quality of their implanted ear with normal hearing. The interaural differences can result in dissatisfaction with speech comprehension and reduced time of usage of the speech processor; hence, prolonging auditory adaptation time. The proposed calibration method presented in this study demonstrates how the frequency distribution of the cochlear implant can be set to adequately approximate the pitch perception of the contralateral normal hearing ear towards improving speech intelligibility in a noisy environment. Methods: In 12 postlingual single-sided deaf patients, subjective interaural pitch-matching was carried out to determine new central frequencies for the reallocation of the frequency bands of their speech processor (CP910, CP950 or CP1000, Cochlear, Australia). The patients were asked to compare the pitch of the tones presented to their normal hearing ear to the pitch of individual channels of their cochlear implant (CI522 or CI622, Cochlear, Australia). A third-degree polynomial curve was fit to the acquired matching frequencies to create the new frequency allocation table. Audiological measurements (free-field aided thresholds, speech reception thresholds, and monosyllabic word recognition score) in noise, together with a Speech, Spatial and Qualities of Hearing Scale (SSQ12) questionnaire (short version of the original SSQ) results were evaluated prior to the pitch-matching procedure, and again, 2 weeks later. Results: The free-field aided thresholds of the patients showed no greater shift than ± 5 dB following the procedure; however, their monosyllabic word recognition score in noise improved significantly (mean − 9.58%, SD 4.98%, matched pairs t test comparison: p < 0.001). The results of the SSQ12 questionnaire also showed significant improvement in speech intelligibility, sound localization, and sound quality (mean 0.96 points, SD 0.45 points, matched pairs t test comparison: p < 0.001). Conclusions: Matching the pitch perception of the implanted cochlea with the sensation of the normal hearing contralateral ear, resulted in significant changes in the quality of hearing in patients with single-sided deafness. It is plausible the procedure can usher positive results in bimodal patients or following sequential bilateral cochlear implantation.
- 3 May 2023
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 280 (11) , 4851-4859
Open AccessMatching the pitch perception of the cochlear implanted ear with the contralateral ear in patients with single-sided deafness: a novel approach
Purpose: Single-sided deaf patients following cochlear implantation often compare the sound quality of their implanted ear with normal hearing. The interaural differences can result in dissatisfaction with speech comprehension and reduced time of usage of the speech processor; hence, prolonging auditory adaptation time. The proposed calibration method presented in this study demonstrates how the frequency distribution of the cochlear implant can be set to adequately approximate the pitch perception of the contralateral normal hearing ear towards improving speech intelligibility in a noisy environment. Methods: In 12 postlingual single-sided deaf patients, subjective interaural pitch-matching was carried out to determine new central frequencies for the reallocation of the frequency bands of their speech processor (CP910, CP950 or CP1000, Cochlear, Australia). The patients were asked to compare the pitch of the tones presented to their normal hearing ear to the pitch of individual channels of their cochlear implant (CI522 or CI622, Cochlear, Australia). A third-degree polynomial curve was fit to the acquired matching frequencies to create the new frequency allocation table. Audiological measurements (free-field aided thresholds, speech reception thresholds, and monosyllabic word recognition score) in noise, together with a Speech, Spatial and Qualities of Hearing Scale (SSQ12) questionnaire (short version of the original SSQ) results were evaluated prior to the pitch-matching procedure, and again, 2 weeks later. Results: The free-field aided thresholds of the patients showed no greater shift than ± 5 dB following the procedure; however, their monosyllabic word recognition score in noise improved significantly (mean − 9.58%, SD 4.98%, matched pairs t test comparison: p < 0.001). The results of the SSQ12 questionnaire also showed significant improvement in speech intelligibility, sound localization, and sound quality (mean 0.96 points, SD 0.45 points, matched pairs t test comparison: p < 0.001). Conclusions: Matching the pitch perception of the implanted cochlea with the sensation of the normal hearing contralateral ear, resulted in significant changes in the quality of hearing in patients with single-sided deafness. It is plausible the procedure can usher positive results in bimodal patients or following sequential bilateral cochlear implantation.
- Open Access
- 1 October 2021
- Published by Akademiai Kiado Zrt. in Orvosi Hetilap
- Vol. 162 (40) , 1619-1626
Historical overview and surgical applications of the Vibrant Soundbridge active middle ear implant
The Vibrant Soundbridge active middle ear implant can provide a reliable solution for hearing rehabilitation of patients with conductive, sensorineural or mixed hearing loss. For sensorineural hearing loss, the air conduction threshold of the patient should not be more increased than 80-85 dBHL at the range of 3-4 kHz, and for conductive and mixed hearing loss, the bone conduction threshold should not be more increased than 45-65 dBHL between 0.5 and 4 kHz. The standard surgical procedure was originally designed for purely sensorineural hearing loss, and the fixation clip of the vibrating transducer needed to be crimped onto the long process of the incus. In many cases, it is impossible to crimp the vibrator onto the incus. In order to solve such circumstances, fixation clips (couplers) have been developed. There are two options to crimp the device on the incus: applying a long process coupler or a short process coupler. For conductive or mixed hearing loss, a round window soft coupler has been introduced. In advanced otosclerotic cases, a special combined technique of Soundbridge implantation with simultaneous stapedotomy can result in sufficient hearing rehabilitation. These techniques significantly broadened the scale of possibilities for the implantation, therefore, it became a widely utilized, reliable procedure. At the Department of Otorhino-laryngology, Clinical Center, University of Pecs, in addition to a noteworthy amount of incus vibroplasty, several cases of round window vibroplasty have also been performed. The aim of the present study is to summarize the history of development of the Vibrant Soundbridge and to present an overview of the applicable surgical techniques.
- 1 October 2021
- Published by Akademiai Kiado Zrt. in Orvosi Hetilap
- Vol. 162 (40) , 1619-1626
Open AccessHistorical overview and surgical applications of the Vibrant Soundbridge active middle ear implant
The Vibrant Soundbridge active middle ear implant can provide a reliable solution for hearing rehabilitation of patients with conductive, sensorineural or mixed hearing loss. For sensorineural hearing loss, the air conduction threshold of the patient should not be more increased than 80-85 dBHL at the range of 3-4 kHz, and for conductive and mixed hearing loss, the bone conduction threshold should not be more increased than 45-65 dBHL between 0.5 and 4 kHz. The standard surgical procedure was originally designed for purely sensorineural hearing loss, and the fixation clip of the vibrating transducer needed to be crimped onto the long process of the incus. In many cases, it is impossible to crimp the vibrator onto the incus. In order to solve such circumstances, fixation clips (couplers) have been developed. There are two options to crimp the device on the incus: applying a long process coupler or a short process coupler. For conductive or mixed hearing loss, a round window soft coupler has been introduced. In advanced otosclerotic cases, a special combined technique of Soundbridge implantation with simultaneous stapedotomy can result in sufficient hearing rehabilitation. These techniques significantly broadened the scale of possibilities for the implantation, therefore, it became a widely utilized, reliable procedure. At the Department of Otorhino-laryngology, Clinical Center, University of Pecs, in addition to a noteworthy amount of incus vibroplasty, several cases of round window vibroplasty have also been performed. The aim of the present study is to summarize the history of development of the Vibrant Soundbridge and to present an overview of the applicable surgical techniques.
- 28 November 2018
- Published by Wolters Kluwer Health in Hearing Balance and Communication
- Vol. 16 (4) , 232-237
Cochlear implantation in patients afflicted with inner ear malformations – the Pécs experience
Purpose: To successfully analyze the surgical and audiological results of cochlear implantation in patients afflicted with inner ear malformations. This study briefly presents our surgical strategies, the selected implants and the audiological results. Method: Objective hearing threshold was measured using an auditory brainstem response and middle latency response audiometry. Structural imaging of high resolution temporal bone computer tomography and inner ear MR scan was performed in support of all patients. Images revealed bilateral cochlear malformation in seven patients. Three ears with common cavity deformity, two ears with incomplete partition type I and three ears suffering from cochlear hypoplasia were all rehabilitated using cochlear implantation. The type of the electrode and the surgical technique were individually determined reflective of the type of malformation. The success of the surgery and potential postoperative complications were duly noted and fully registered. Postoperative audiological measurements were performed and the results were analyzed. Results: The average audiological follow-up was 40.3 months. The average free field, pure-tone threshold of speech frequencies (0.5–3 kHz) gained postoperatively were within the range of 32.5–41.6 dB. In two of the procedures, a cerebrospinal fluid gusher did occur and was successfully managed intraoperatively, all without any postoperative complications. Conclusion: Temporal bone high resolution CT and inner ear MRI imaging are mandatory to detect and characterize the inner ear malformation. Early implantation of malformed cochlea is crucial towards achieving ideal postoperative audiological results. Notably, an intraoperative gusher is not regarded as a contraindication of the cochlear implantation.
- 28 November 2018
- Published by Wolters Kluwer Health in Hearing Balance and Communication
- Vol. 16 (4) , 232-237
Cochlear implantation in patients afflicted with inner ear malformations – the Pécs experience
Purpose: To successfully analyze the surgical and audiological results of cochlear implantation in patients afflicted with inner ear malformations. This study briefly presents our surgical strategies, the selected implants and the audiological results. Method: Objective hearing threshold was measured using an auditory brainstem response and middle latency response audiometry. Structural imaging of high resolution temporal bone computer tomography and inner ear MR scan was performed in support of all patients. Images revealed bilateral cochlear malformation in seven patients. Three ears with common cavity deformity, two ears with incomplete partition type I and three ears suffering from cochlear hypoplasia were all rehabilitated using cochlear implantation. The type of the electrode and the surgical technique were individually determined reflective of the type of malformation. The success of the surgery and potential postoperative complications were duly noted and fully registered. Postoperative audiological measurements were performed and the results were analyzed. Results: The average audiological follow-up was 40.3 months. The average free field, pure-tone threshold of speech frequencies (0.5–3 kHz) gained postoperatively were within the range of 32.5–41.6 dB. In two of the procedures, a cerebrospinal fluid gusher did occur and was successfully managed intraoperatively, all without any postoperative complications. Conclusion: Temporal bone high resolution CT and inner ear MRI imaging are mandatory to detect and characterize the inner ear malformation. Early implantation of malformed cochlea is crucial towards achieving ideal postoperative audiological results. Notably, an intraoperative gusher is not regarded as a contraindication of the cochlear implantation.