WWWei Wang

Wei Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wei Wang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In vivo Assessment of Supra-Cervical Fetal Membrane by MRI 3D CISS: A Preliminary Study

    by Wenxu Qi, Peinan Zhao, Wei Wang, Zhexian Sun, Xiao Ma, Hui Wang, Wenjie Wu, Zichao Wen, Zulfia Kisrieva-Ware, Pamela K. Woodard, et al.

    In approximately 8% of term births and 33% of pre-term births, the fetal membrane (FM) ruptures before delivery. In vitro studies of FMs after delivery have suggested the series of events leading to rupture, but no in vivo studies have confirmed this model. In this study, we used a three-dimensional constructive interference in steady state (3D-CISS) sequence to examine the FM at the cervical internal os zone during pregnancy; 18 pregnant women with one to three longitudinal MRI scans were included in this study. In 14 women, the FM appeared normal and completely intact. In four women, we noted several FM abnormalities including cervical funneling, chorioamniotic separation, and chorion rupture. Our data support the in vitro model that the FM ruptures according to a sequence starting with the stretch of chorion and amnion, then the separation of amnion from chorion, next the rupture of chorion, and finally the rupture of amnion ruptures. These findings hold great promise to help to develop an in vivo magnetic resonance imaging marker that improves examination of the FMs.


  • Assessing method agreement for paired repeated binary measurements administered by multiple raters

    by Wei Wang, Nan Lin, Jordan D. Oberhaus, Michael S. Avidan

    Method comparison studies are essential for development in medical and clinical fields. These studies often compare a cheaper, faster, or less invasive measuring method with a widely used one to see if they have sufficient agreement for interchangeable use. Moreover, unlike simply reading measurements from devices, eg, reading body temperature from a thermometer, the response measurement in many clinical and medical assessments is impacted not only by the measuring device but also by the rater. For example, widespread inconsistencies are commonly observed among raters in psychological or cognitive assessment studies due to different characteristics such as rater training and experience, especially in large‐scale assessment studies when many raters are employed. This paper proposes a model‐based approach to assess agreement of two measuring methods for paired repeated binary measurements under the scenario where the agreement between two measuring methods and the agreement among raters are required to be studied simultaneously. Based upon the generalized linear mixed models (GLMMs), the decision on the adequacy of interchangeable use is made by testing the equality of fixed effects of methods. Approaches for assessing method agreement, such as the Bland‐Altman diagram and Cohen's kappa, are also developed for repeated binary measurements based upon the latent variables in GLMMs. We assess our novel model‐based approach by simulation studies and a real clinical application, in which patients are evaluated repeatedly for delirium with two validated screening methods. Both the simulation studies and the real data analyses demonstrate that our proposed approach can effectively assess method agreement.