Isabel Cristina Sales Fontes Jardim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Isabel Cristina Sales Fontes Jardim has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Carol H. Collins
Universidade Estadual de Campinas, Campinas, Brazil
4 shared publicationsKenneth E Collins
Universidade Estadual de Campinas, Campinas, Brazil
3 shared publicationsLiane Maldaner
University of Campinas
3 shared publications- Márcia Cristina Breitkreitz
Institute of Chemistry, University of Campinas (UNICAMP), 13083-970 Campinas, SP, Brazil
3 shared publications - Anízio Márcio Faria
Universidade Federal de Uberlândia
2 shared publications Daniele Oshita
Institute of Chemistry, University of Campinas, São Paulo, Brazil
2 shared publications
Latest Publications
- 1 November 2020
- Published by Wiley in Journal of Separation Science
- Vol. 43 (22) , 4234-4242
Sequential design of experiments approach for the multiproduct analysis of cholesterol-lowering drugs by ultra-high-performance supercritical fluid chromatography
A multiproduct approach toward method development is presented for a fast and reliable analysis of the eight most important cholesterol-lowering drugs via ultra-high-performance supercritical fluid chromatography. A two-step approach based on design of experiments was applied: (1) selection of the stationary phase, organic modifier, and diluent in the mobile phase through a multilevel categorical design and (2) optimization of the elution strength by varying the pressure, temperature, and gradient using a central composite design. Finally, the flow rate was adjusted. The first design selected UPC(2)Torus 1-AA as the column, ethanol:water as the organic modifier, and acetonitrile:ethanol 3:2 v/v as the diluent. The results led to a pressure, column temperature, and gradient elution of 14.83 MPa, 42 degrees C, and 5-15.5% of ethanol:water in CO2, respectively. The flow rate was set at 1.8 mL/min, providing a total analysis time of 4 min. This multiproduct method was validated and applied to 11 different commercial products available in the Brazilian market, and it was found to be accurate, withr> 0.990, recoveries between 95 and 105%, and precision not higher than 5.4%. Therefore, this method was shown to be a greener alternative for the analysis of these pharmaceuticals.
- 1 November 2020
- Published by Wiley in Journal of Separation Science
- Vol. 43 (22) , 4234-4242
Sequential design of experiments approach for the multiproduct analysis of cholesterol-lowering drugs by ultra-high-performance supercritical fluid chromatography
A multiproduct approach toward method development is presented for a fast and reliable analysis of the eight most important cholesterol-lowering drugs via ultra-high-performance supercritical fluid chromatography. A two-step approach based on design of experiments was applied: (1) selection of the stationary phase, organic modifier, and diluent in the mobile phase through a multilevel categorical design and (2) optimization of the elution strength by varying the pressure, temperature, and gradient using a central composite design. Finally, the flow rate was adjusted. The first design selected UPC(2)Torus 1-AA as the column, ethanol:water as the organic modifier, and acetonitrile:ethanol 3:2 v/v as the diluent. The results led to a pressure, column temperature, and gradient elution of 14.83 MPa, 42 degrees C, and 5-15.5% of ethanol:water in CO2, respectively. The flow rate was set at 1.8 mL/min, providing a total analysis time of 4 min. This multiproduct method was validated and applied to 11 different commercial products available in the Brazilian market, and it was found to be accurate, withr> 0.990, recoveries between 95 and 105%, and precision not higher than 5.4%. Therefore, this method was shown to be a greener alternative for the analysis of these pharmaceuticals.
- 23 August 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (20) , 3855-3862
Synthesis and evaluation of a pentafluorobenzamide stationary phase for HPLC separations in the reversed phase and hydrophilic interaction modes
A pentafluorobenzamide stationary phase was synthesized by an easy method with no intermediate purification steps. Physicochemical characterization (elemental analysis, fourier transform infrared spectroscopy, 29Si and 13C nuclear magnetic resonance spectroscopy) confirmed the presence of pentafluorobenzamide functionalization on the surface of the silica particles. The pentafluorobenzamide stationary phase proved to be quite versatile as it can be used in two different modes in liquid chromatography: reversed phase and hydrophilic interaction liquid chromatography. Chromatographic characterizations in both modes confirmed the multiple interactions established by the new stationary phase, such as hydrogen bonding and π‐π and ion‐exchange interactions. The pentafluorobenzamide stationary phase was successfully employed for the separation of nucleosides and antihypertensive drugs under hydrophilic interaction liquid chromatography conditions, as well as pesticides and benzodiazepine using reversed phase conditions. The stationary phase showed significant potential when compared with commercial columns.
- 23 August 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (20) , 3855-3862
Synthesis and evaluation of a pentafluorobenzamide stationary phase for HPLC separations in the reversed phase and hydrophilic interaction modes
A pentafluorobenzamide stationary phase was synthesized by an easy method with no intermediate purification steps. Physicochemical characterization (elemental analysis, fourier transform infrared spectroscopy, 29Si and 13C nuclear magnetic resonance spectroscopy) confirmed the presence of pentafluorobenzamide functionalization on the surface of the silica particles. The pentafluorobenzamide stationary phase proved to be quite versatile as it can be used in two different modes in liquid chromatography: reversed phase and hydrophilic interaction liquid chromatography. Chromatographic characterizations in both modes confirmed the multiple interactions established by the new stationary phase, such as hydrogen bonding and π‐π and ion‐exchange interactions. The pentafluorobenzamide stationary phase was successfully employed for the separation of nucleosides and antihypertensive drugs under hydrophilic interaction liquid chromatography conditions, as well as pesticides and benzodiazepine using reversed phase conditions. The stationary phase showed significant potential when compared with commercial columns.
- 25 July 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (16) , 3339-3345
Study of the chromatographic parameters of ultra‐high‐performance supercritical fluid chromatography and method development using a design of experiments approach for the quantification of pesticides in lettuce
We examine the potential of ultra‐high‐performance supercritical fluid chromatography for multiresidue quantification of ten pesticides commonly applied to lettuce and compares it to ultra‐high‐performance liquid chromatography. Initially, a thorough study of the stationary and mobile phase composition and injection solvent was carried out. In a second step, a chemometric approach based on design of experiments was used to simultaneously study the influence of temperature, pressure, and percentage of ethanol on the retention, resolution and symmetry of the peaks. Using this approach, it was possible to obtain the Design Space, a robust region where complete separation of the analytes was achieved, with acceptable peak shape. Both methods were validated according to the figures of merit: selectivity, linearity, quantification limit, accuracy (in terms of recovery), and precision (repeatability and intermediate precision) and used to quantify the pesticides in lettuce samples. Comparing both techniques, it was concluded that the limits of quantification, accuracy, and precision were similar. However, in supercritical fluid chromatography, a reduced volume of organic solvent was used, the method was faster and generated lower amounts of residues.
- 25 July 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (16) , 3339-3345
Study of the chromatographic parameters of ultra‐high‐performance supercritical fluid chromatography and method development using a design of experiments approach for the quantification of pesticides in lettuce
We examine the potential of ultra‐high‐performance supercritical fluid chromatography for multiresidue quantification of ten pesticides commonly applied to lettuce and compares it to ultra‐high‐performance liquid chromatography. Initially, a thorough study of the stationary and mobile phase composition and injection solvent was carried out. In a second step, a chemometric approach based on design of experiments was used to simultaneously study the influence of temperature, pressure, and percentage of ethanol on the retention, resolution and symmetry of the peaks. Using this approach, it was possible to obtain the Design Space, a robust region where complete separation of the analytes was achieved, with acceptable peak shape. Both methods were validated according to the figures of merit: selectivity, linearity, quantification limit, accuracy (in terms of recovery), and precision (repeatability and intermediate precision) and used to quantify the pesticides in lettuce samples. Comparing both techniques, it was concluded that the limits of quantification, accuracy, and precision were similar. However, in supercritical fluid chromatography, a reduced volume of organic solvent was used, the method was faster and generated lower amounts of residues.
- 7 February 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (8) , 1726-1733
Development and validation of an analytical method for multiresidue determination of pesticides in lettuce using QuEChERS–UHPLC–MS/MS
A new analytical method for multi-residue determination of 16 multiclass pesticides in lettuce was developed using ultra high performance liquid chromatography with tandem mass spectrometry with a triple quadrupole mass analyzer and positive mode electrospray ionization, using a previously optimized quick, easy, cheap, effective, rugged, and safe method for sample preparation. Validation studies, according to Document SANTE/11945/2015, demonstrated that the developed method is selective, accurate and precise, providing recoveries of 70–120%, relative standard deviations ≤ 20% and quantification limits from 3 μg kg−1. The method was compared with one based on high-performance liquid chromatography with tandem mass spectrometry, in terms of chromatographic performance, detectability and matrix effect for five varieties of lettuce. The new method provided a reduction in the time for the chromatographic analysis of 50%, from 30 to 15 min, using a lower mobile phase flow-rate (0.147 mL min−1), which reduced the consumption of mobile phase by 25%, and injection of smaller amounts of sample (1.7 μL). Lower limits of quantification were obtained for almost all pesticides studied for green-leaf lettuce. However, in relation to the matrix effect, four of the five types of lettuce studied presented higher matrix effects. This article is protected by copyright. All rights reserved
- 7 February 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (8) , 1726-1733
Development and validation of an analytical method for multiresidue determination of pesticides in lettuce using QuEChERS–UHPLC–MS/MS
A new analytical method for multi-residue determination of 16 multiclass pesticides in lettuce was developed using ultra high performance liquid chromatography with tandem mass spectrometry with a triple quadrupole mass analyzer and positive mode electrospray ionization, using a previously optimized quick, easy, cheap, effective, rugged, and safe method for sample preparation. Validation studies, according to Document SANTE/11945/2015, demonstrated that the developed method is selective, accurate and precise, providing recoveries of 70–120%, relative standard deviations ≤ 20% and quantification limits from 3 μg kg−1. The method was compared with one based on high-performance liquid chromatography with tandem mass spectrometry, in terms of chromatographic performance, detectability and matrix effect for five varieties of lettuce. The new method provided a reduction in the time for the chromatographic analysis of 50%, from 30 to 15 min, using a lower mobile phase flow-rate (0.147 mL min−1), which reduced the consumption of mobile phase by 25%, and injection of smaller amounts of sample (1.7 μL). Lower limits of quantification were obtained for almost all pesticides studied for green-leaf lettuce. However, in relation to the matrix effect, four of the five types of lettuce studied presented higher matrix effects. This article is protected by copyright. All rights reserved
- 18 November 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (3) , 982-989
Evaluation of dispersive and cartridge SPE clean-up procedures using the modified QuEChERS method for the analysis of pesticides in strawberries
This manuscript describes a detailed evaluation of the different procedures of the modified QuEChERS method for pesticide residues in strawberries using UHPLC-DAD.
- 18 November 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (3) , 982-989
Evaluation of dispersive and cartridge SPE clean-up procedures using the modified QuEChERS method for the analysis of pesticides in strawberries
This manuscript describes a detailed evaluation of the different procedures of the modified QuEChERS method for pesticide residues in strawberries using UHPLC-DAD.
- 18 July 2014
- Published by Springer Nature in Chromatographia
- Vol. 77 (19-20) , 1291-1298
Comparison of Different Sorbents in the QuEChERS Method for the Determination of Pesticide Residues in Strawberries by LC–MS/MS
- 18 July 2014
- Published by Springer Nature in Chromatographia
- Vol. 77 (19-20) , 1291-1298
Comparison of Different Sorbents in the QuEChERS Method for the Determination of Pesticide Residues in Strawberries by LC–MS/MS
- 24 August 2010
- Published by Springer Nature in Chromatographia
- Vol. 72 (7-8) , 617-626
Preparation and Characterization of a Microwave-Immobilized Fluorinated Stationary Phase for RP-LC
- 24 August 2010
- Published by Springer Nature in Chromatographia
- Vol. 72 (7-8) , 617-626
Preparation and Characterization of a Microwave-Immobilized Fluorinated Stationary Phase for RP-LC
- Open Access
- 1 January 2009
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 32 (2) , 431-440
Eletrocromatografia capilar: contextualização, estado da arte e perspectivas
Capillary electrochromatography (CEC) is a separation technique in which the mobile phase flow is based on the application of a voltage across a packed capillary, which generates an electroosmotic flow that transports the analytes along the capillary toward the detector. As it combines the separation mechanisms of high-performance liquid chromatography (HPLC) and of capillary electrophoresis (CE), CEC can be considered a hybrid of HPLC and CE. This review presents some fundamental aspects of CEC and is focused on the instrumental advances of the technique, such as column technology, operation modes and detection systems, presenting recent papers on these topics and some applications and perspectives about CEC
- 1 January 2009
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 32 (2) , 431-440
Open AccessEletrocromatografia capilar: contextualização, estado da arte e perspectivas
Capillary electrochromatography (CEC) is a separation technique in which the mobile phase flow is based on the application of a voltage across a packed capillary, which generates an electroosmotic flow that transports the analytes along the capillary toward the detector. As it combines the separation mechanisms of high-performance liquid chromatography (HPLC) and of capillary electrophoresis (CE), CEC can be considered a hybrid of HPLC and CE. This review presents some fundamental aspects of CEC and is focused on the instrumental advances of the technique, such as column technology, operation modes and detection systems, presenting recent papers on these topics and some applications and perspectives about CEC