Jianfeng Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jianfeng Wang has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
Shuyu Chen
Beijing Institute of Technology
6 shared publicationsMarina Marjanovic
Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, United States of America
5 shared publicationsSisi Guo
5 shared publications- Stephen A. Boppart
University of Illinois Urbana-Champaign
5 shared publications Hao Wang
Beijing Institute of Technology
4 shared publicationsRuoyu Zhang
Beijing Institute of Technology
4 shared publications
Latest Publications
- 30 June 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (13) , 3745
Position-tracked handheld optical coherence tomography guided by projected wide-field near-infrared autofluorescence imaging for breast tumor margin assessment
Breast tumor margin assessment requires rapid identification of regions of interest (ROIs) and detailed visualization of their microstructural alterations. Here, we report position-tracked handheld optical coherence tomography (PH-OCT) guided by projected wide-field near-infrared autofluorescence (PW-NIRAF) imaging to meet these requirements. The PW-NIRAF system comprises a near-infrared (NIR) imaging camera and a projector with calibrated fields of view, enabling ROI identification and projection of the corresponding ROI map over a 10 × 10 cm 2 field of view (FOV). The PH-OCT system consists of a handheld gradient-index-rod-lens-based OCT probe for volumetric visualization of ROI microstructure, with each OCT volume covering 4 × 4 × 1 mm 3 at 9.66 μm axial and 17.54 μm lateral resolution. Blue and green tapes used as color markers on the OCT-probe housing, together with a color camera and a deep-learning-based YOLOv11-pose model, enable real-time probe-tip localization for OCT volume acquisition across PW-NIRAF-projected ROIs, providing depth-resolved microstructural information beyond wide-field NIRAF contrast. Color-camera/projector calibration further enables back-projection of OCT-derived tumor-region maps onto the tissue surface. Validation on ex vivo breast tissue lays the foundation for future intraoperative breast tumor margin assessment using PW-NIRAF-guided PH-OCT.
- 30 June 2026
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (13) , 3745
Position-tracked handheld optical coherence tomography guided by projected wide-field near-infrared autofluorescence imaging for breast tumor margin assessment
Breast tumor margin assessment requires rapid identification of regions of interest (ROIs) and detailed visualization of their microstructural alterations. Here, we report position-tracked handheld optical coherence tomography (PH-OCT) guided by projected wide-field near-infrared autofluorescence (PW-NIRAF) imaging to meet these requirements. The PW-NIRAF system comprises a near-infrared (NIR) imaging camera and a projector with calibrated fields of view, enabling ROI identification and projection of the corresponding ROI map over a 10 × 10 cm 2 field of view (FOV). The PH-OCT system consists of a handheld gradient-index-rod-lens-based OCT probe for volumetric visualization of ROI microstructure, with each OCT volume covering 4 × 4 × 1 mm 3 at 9.66 μm axial and 17.54 μm lateral resolution. Blue and green tapes used as color markers on the OCT-probe housing, together with a color camera and a deep-learning-based YOLOv11-pose model, enable real-time probe-tip localization for OCT volume acquisition across PW-NIRAF-projected ROIs, providing depth-resolved microstructural information beyond wide-field NIRAF contrast. Color-camera/projector calibration further enables back-projection of OCT-derived tumor-region maps onto the tissue surface. Validation on ex vivo breast tissue lays the foundation for future intraoperative breast tumor margin assessment using PW-NIRAF-guided PH-OCT.
- 6 May 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (14) , 3980-3987
Feasibility study of deep-learning-based models for automated macular hole segmentation using optical coherence tomography B-scans
We aim to evaluate the feasibility of deep-learning (DL)-based models for automated macular hole (MH) segmentation using optical coherence tomography (OCT) B-scans. Four DL-based OCT B-scan segmentation models with different architectures, including ResNet-50 or EfficientNet backbones, feature pyramid network (FPN) or weighted bi-directional FPN (BiFPN) necks, and FPN head, namely Model 1 (ResNet-50, FPN, FPN), Model 2 (ResNet-50, BiFPN, FPN), Model 3 (EfficientNet, FPN, FPN), and Model 4 (EfficientNet, BiFPN, FPN), were developed, followed by their implementations on 3295 paired OCT B-scans and labels belonging to MH and non-MH. The mean intersection over union (IOU) values (0.969, 0.968, 0.975, and 0.977 for Models 1–4) indicate the best performance of Model 4. The percentage proportion of OCT B-scans with IOU values between 0.8 and 1 reached 94.33%, 95.32%, 100%, and 100% for MH, choroid, retina, and intraretinal cysts (IRCs), respectively, demonstrating the potential of the four DL-based models developed for automated MH segmentation from OCT B-scans.
- 6 May 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (14) , 3980-3987
Feasibility study of deep-learning-based models for automated macular hole segmentation using optical coherence tomography B-scans
We aim to evaluate the feasibility of deep-learning (DL)-based models for automated macular hole (MH) segmentation using optical coherence tomography (OCT) B-scans. Four DL-based OCT B-scan segmentation models with different architectures, including ResNet-50 or EfficientNet backbones, feature pyramid network (FPN) or weighted bi-directional FPN (BiFPN) necks, and FPN head, namely Model 1 (ResNet-50, FPN, FPN), Model 2 (ResNet-50, BiFPN, FPN), Model 3 (EfficientNet, FPN, FPN), and Model 4 (EfficientNet, BiFPN, FPN), were developed, followed by their implementations on 3295 paired OCT B-scans and labels belonging to MH and non-MH. The mean intersection over union (IOU) values (0.969, 0.968, 0.975, and 0.977 for Models 1–4) indicate the best performance of Model 4. The percentage proportion of OCT B-scans with IOU values between 0.8 and 1 reached 94.33%, 95.32%, 100%, and 100% for MH, choroid, retina, and intraretinal cysts (IRCs), respectively, demonstrating the potential of the four DL-based models developed for automated MH segmentation from OCT B-scans.
- 10 April 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (12) , 3158-3166
Development of a smartphone-based multi-spectral imaging system and its performance validation through radiodermatitis assessment
Cancerous skin lesions (i.e., skin cancers) are the most common types of cancer. Currently, there exists an unmet clinical need to develop advanced imaging tools for skin diagnosis and associated treatment monitoring. In this work, we reported the development of a smartphone-based multi-spectral imaging (MSI) system to fulfill the need and validated its performance through radiodermatitis assessment: one of the severe side effects of skin cancer radiotherapy (RT) treatment that needs to be objectively graded to avoid the possible RT treatment cessation thereof. In combination with a graphics processing unit (GPU)-accelerated Monte Carlo simulations code, Monte Carlo look-up table (MCLUT)-based skin-layer-resolved physiological parameters [i.e., the blood volume fraction (BVF) and the oxygen saturation of hemoglobin in blood] were derived from the multi-spectra measured. The mean square error (MSE) between the MCLUT-derived spectra and the experimentally acquired multi-spectra was found to be less than 0.0031, confirming the robustness of the physiological parameters derived. Further analysis of variance (ANOVA) conducted on the BVF and the oxygen saturation of hemoglobin in blood revealed a significant (P<0.001, ANOVA) increase in erythema. Additionally, partial least square discriminant analysis (PLS-DA) implemented on the multi-spectra leads to an overall classification accuracy of 85.9% for the separation between normal skin and erythema, confirming the potential of the smartphone-based MSI system developed for radiodermatitis assessment.
- 10 April 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (12) , 3158-3166
Development of a smartphone-based multi-spectral imaging system and its performance validation through radiodermatitis assessment
Cancerous skin lesions (i.e., skin cancers) are the most common types of cancer. Currently, there exists an unmet clinical need to develop advanced imaging tools for skin diagnosis and associated treatment monitoring. In this work, we reported the development of a smartphone-based multi-spectral imaging (MSI) system to fulfill the need and validated its performance through radiodermatitis assessment: one of the severe side effects of skin cancer radiotherapy (RT) treatment that needs to be objectively graded to avoid the possible RT treatment cessation thereof. In combination with a graphics processing unit (GPU)-accelerated Monte Carlo simulations code, Monte Carlo look-up table (MCLUT)-based skin-layer-resolved physiological parameters [i.e., the blood volume fraction (BVF) and the oxygen saturation of hemoglobin in blood] were derived from the multi-spectra measured. The mean square error (MSE) between the MCLUT-derived spectra and the experimentally acquired multi-spectra was found to be less than 0.0031, confirming the robustness of the physiological parameters derived. Further analysis of variance (ANOVA) conducted on the BVF and the oxygen saturation of hemoglobin in blood revealed a significant (P<0.001, ANOVA) increase in erythema. Additionally, partial least square discriminant analysis (PLS-DA) implemented on the multi-spectra leads to an overall classification accuracy of 85.9% for the separation between normal skin and erythema, confirming the potential of the smartphone-based MSI system developed for radiodermatitis assessment.
- 23 December 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (1) , 320-333
Development and performance validation of an affordable and portable high-resolution darkfield polarization-sensitive multispectral imaging microscope for the assessment of radiation dermatitis and fibrosis
Radiation therapy (RT) is widely used for cancer treatment but is found with side effects of radiation dermatitis and fibrosis thereby calling for timely assessment. Nevertheless, current clinical assessment methods are found to be subjective, prone to bias, and accompanied by variability. There is, therefore, an unmet clinical need to explore a new assessment technique, ideally portable and affordable, making it accessible to less developed regions too. We developed an affordable (16764 CNY) and portable high-resolution ((3.91 μm) darkfield polarization-sensitive multispectral imaging (PS-MSI) microscope. The implementation of the Monte Carlo simulation on the PS multi spectra allows the quantitative analysis of physiological parameters (i.e., blood volume fraction (BVF) and oxygen saturation of hemoglobin) at different skin layers for the dermatitis assessment. Further derivation of the degree of linear polarization (DOLP) reflects randomly distributed collagen fibers associated with fibrosis for the fibrosis assessment. PS-MSI microscope developed revealed a significant decrease (p < 0.001, analysis of variance, ANOVA) in the DOLP associated with fibrosis like scar tissue, and significant (p < 0.001, ANOVA) increases in BVF and oxygen saturation of hemoglobin accompanying artificially induced dermatitis. One-dimensional convolutional neural network implemented on the DOLP and multiple spectra achieved accuracies of 96% and 92.2%, respectively, for the classification of the artificially induced skin dermatitis and fibrosis like scar, demonstrating the potential of the affordable PS-MSI microscope developed for objective, unbiased and consistent assessment of radiation dermatitis and fibrosis in the clinics.
- 23 December 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (1) , 320-333
Development and performance validation of an affordable and portable high-resolution darkfield polarization-sensitive multispectral imaging microscope for the assessment of radiation dermatitis and fibrosis
Radiation therapy (RT) is widely used for cancer treatment but is found with side effects of radiation dermatitis and fibrosis thereby calling for timely assessment. Nevertheless, current clinical assessment methods are found to be subjective, prone to bias, and accompanied by variability. There is, therefore, an unmet clinical need to explore a new assessment technique, ideally portable and affordable, making it accessible to less developed regions too. We developed an affordable (16764 CNY) and portable high-resolution ((3.91 μm) darkfield polarization-sensitive multispectral imaging (PS-MSI) microscope. The implementation of the Monte Carlo simulation on the PS multi spectra allows the quantitative analysis of physiological parameters (i.e., blood volume fraction (BVF) and oxygen saturation of hemoglobin) at different skin layers for the dermatitis assessment. Further derivation of the degree of linear polarization (DOLP) reflects randomly distributed collagen fibers associated with fibrosis for the fibrosis assessment. PS-MSI microscope developed revealed a significant decrease (p < 0.001, analysis of variance, ANOVA) in the DOLP associated with fibrosis like scar tissue, and significant (p < 0.001, ANOVA) increases in BVF and oxygen saturation of hemoglobin accompanying artificially induced dermatitis. One-dimensional convolutional neural network implemented on the DOLP and multiple spectra achieved accuracies of 96% and 92.2%, respectively, for the classification of the artificially induced skin dermatitis and fibrosis like scar, demonstrating the potential of the affordable PS-MSI microscope developed for objective, unbiased and consistent assessment of radiation dermatitis and fibrosis in the clinics.
- 22 November 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (23) , 6733-6736
Autofluorescence imaging guided needle-type Raman spectroscopy system for breast tumor margin assessment
A trajectory-tracked, near-infrared autofluorescence imaging guided, biochemical signature-projected needle-type Raman spectroscopy (TNBN-RS) system integrated on a medical cart was developed for rapid wide-field breast tissue stratification. A wide-field (10 × 10 cm2) near-infrared autofluorescence (NIRAF) imaging subsystem was developed for gross stratification of breast tissue types based on higher NIRAF intensity associated with breast cancer, followed by projection of NIRAF-identified breast tumor margins onto the tissue of interest with a compact projector. Raman spectra were further acquired from the NIRAF projected regions for confirmed margin assessment using a needle-type Raman probe equipped with color camera-based probe trajectory tracking. The trajectory of the Raman probe and the accompanying RS biochemical signature-based margin assessment were instantly projected. A unique field of view (FOV) calibration method was proposed to calibrate the TNBN-RS FOVs, resulting in a projection accuracy of ex vivo breast tissue, demonstrating its potential for rapid intraoperative breast tumor margin assessment.
- 22 November 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (23) , 6733-6736
Autofluorescence imaging guided needle-type Raman spectroscopy system for breast tumor margin assessment
A trajectory-tracked, near-infrared autofluorescence imaging guided, biochemical signature-projected needle-type Raman spectroscopy (TNBN-RS) system integrated on a medical cart was developed for rapid wide-field breast tissue stratification. A wide-field (10 × 10 cm2) near-infrared autofluorescence (NIRAF) imaging subsystem was developed for gross stratification of breast tissue types based on higher NIRAF intensity associated with breast cancer, followed by projection of NIRAF-identified breast tumor margins onto the tissue of interest with a compact projector. Raman spectra were further acquired from the NIRAF projected regions for confirmed margin assessment using a needle-type Raman probe equipped with color camera-based probe trajectory tracking. The trajectory of the Raman probe and the accompanying RS biochemical signature-based margin assessment were instantly projected. A unique field of view (FOV) calibration method was proposed to calibrate the TNBN-RS FOVs, resulting in a projection accuracy of ex vivo breast tissue, demonstrating its potential for rapid intraoperative breast tumor margin assessment.
- 11 November 2024
- Published by Wiley in Journal of Biophotonics
- Vol. 18 (1) , e202400220
Feasibility Study of Label‐Free Raman Spectroscopy for Parathyroid Gland Identification
We aim to evaluate the feasibility of Raman spectroscopy for parathyroid gland (PG) identification during thyroidectomy. Using a novel side‐viewing handheld Raman probe, a total of 324 Raman spectra of four tissue types (i.e., thyroid, lymph node, PG, and lipid) commonly encountered during thyroidectomy were rapidly (< 3 s) acquired from 80 tissue sites (thyroid [n = 10], lymph node [n = 10], PG [n = 40], lipid [n = 20]) of 10 euthanized Wistar rats. Two partial least‐squares (PLS)‐discriminant analysis (DA) detection models were developed, differentiating the lipid and nonlipid (i.e., thyroid, lymph node, and PG) tissues with an accuracy of 100%, and PG, lymph node, and thyroid could be detected with an accuracy of 98.4%, 93.9%, and 95.4% respectively. This work demonstrates the feasibility of Raman spectroscopy technique for PG identification and protection during thyroidectomy at the molecular level.
- 11 November 2024
- Published by Wiley in Journal of Biophotonics
- Vol. 18 (1) , e202400220
Feasibility Study of Label‐Free Raman Spectroscopy for Parathyroid Gland Identification
We aim to evaluate the feasibility of Raman spectroscopy for parathyroid gland (PG) identification during thyroidectomy. Using a novel side‐viewing handheld Raman probe, a total of 324 Raman spectra of four tissue types (i.e., thyroid, lymph node, PG, and lipid) commonly encountered during thyroidectomy were rapidly (< 3 s) acquired from 80 tissue sites (thyroid [n = 10], lymph node [n = 10], PG [n = 40], lipid [n = 20]) of 10 euthanized Wistar rats. Two partial least‐squares (PLS)‐discriminant analysis (DA) detection models were developed, differentiating the lipid and nonlipid (i.e., thyroid, lymph node, and PG) tissues with an accuracy of 100%, and PG, lymph node, and thyroid could be detected with an accuracy of 98.4%, 93.9%, and 95.4% respectively. This work demonstrates the feasibility of Raman spectroscopy technique for PG identification and protection during thyroidectomy at the molecular level.
- 29 August 2024
- Published by Springer Nature in Analytical Sciences
- Vol. 40 (12) , 2101-2109
Comparative study of machine-and deep-learning based classification algorithms for biomedical Raman spectroscopy (RS): case study of RS based pathogenic microbe identification
One key aspect pushing the frontiers of biomedical RS is dedicated machine- or deep- learning (ML or DL) algorithms. Yet, systematic comparative study between ML and DL algorithms has not been conducted for biomedical RS, largely due to the limited availability of open-source and large Raman spectra dataset. Therefore we compared typical ML partial least square-discriminant analysis (PLS-DA) and DL one dimensional convolution neural network (1D-CNN) based pathogenic microbe identification on 12,000 Raman spectra from six species of microbe (i.e., K. aerogenes (Klebsiella aerogenes), C. albicans (Candida albicans), C. glabrata (Candida glabrata), Group A Strep. (Group A Streptococcus), E. coli1 (Escherichia coli1), E. coli2 (Escherichia coli2)) when 100%, 75%, 50% and 25% of the 12,000 Raman spectra were retained. The total Raman dataset was analyzed with 80% split for training and 20% for testing. The 100% retained testing dataset accuracy, area under curve (AUC) of the receiver operating characteristic (ROC) curve were 95.25% and 0.997 for 1D-CNN, which are higher than those (89.42% and 0.979) of PLS-DA. Yet, PLS-DA outperforms 1D-CNN for 75%, 50% and 25% retained testing dataset. The resultant accuracies and AUCs demonstrated the performance reliance of PLS-DA and 1D-CNN on Raman spectra number. Besides, both loadings on the latent variables of PLS-DA and the saliency maps of 1D-CNN largely captured Raman peaks arising from DNA and proteins with comparable interpretability. The results of the current work indicated that both ML and DL algorithms should be explored for application-wise Raman spectra identification to select whichever with higher accuracies and AUCs. Graphical abstract
- 29 August 2024
- Published by Springer Nature in Analytical Sciences
- Vol. 40 (12) , 2101-2109
Comparative study of machine-and deep-learning based classification algorithms for biomedical Raman spectroscopy (RS): case study of RS based pathogenic microbe identification
One key aspect pushing the frontiers of biomedical RS is dedicated machine- or deep- learning (ML or DL) algorithms. Yet, systematic comparative study between ML and DL algorithms has not been conducted for biomedical RS, largely due to the limited availability of open-source and large Raman spectra dataset. Therefore we compared typical ML partial least square-discriminant analysis (PLS-DA) and DL one dimensional convolution neural network (1D-CNN) based pathogenic microbe identification on 12,000 Raman spectra from six species of microbe (i.e., K. aerogenes (Klebsiella aerogenes), C. albicans (Candida albicans), C. glabrata (Candida glabrata), Group A Strep. (Group A Streptococcus), E. coli1 (Escherichia coli1), E. coli2 (Escherichia coli2)) when 100%, 75%, 50% and 25% of the 12,000 Raman spectra were retained. The total Raman dataset was analyzed with 80% split for training and 20% for testing. The 100% retained testing dataset accuracy, area under curve (AUC) of the receiver operating characteristic (ROC) curve were 95.25% and 0.997 for 1D-CNN, which are higher than those (89.42% and 0.979) of PLS-DA. Yet, PLS-DA outperforms 1D-CNN for 75%, 50% and 25% retained testing dataset. The resultant accuracies and AUCs demonstrated the performance reliance of PLS-DA and 1D-CNN on Raman spectra number. Besides, both loadings on the latent variables of PLS-DA and the saliency maps of 1D-CNN largely captured Raman peaks arising from DNA and proteins with comparable interpretability. The results of the current work indicated that both ML and DL algorithms should be explored for application-wise Raman spectra identification to select whichever with higher accuracies and AUCs. Graphical abstract
- 11 May 2024
- Published by Elsevier in Measurement
- Vol. 235, 114889
A noise-robust vibration signal extraction method utilizing intensity optical flow
- 11 May 2024
- Published by Elsevier in Measurement
- Vol. 235, 114889
A noise-robust vibration signal extraction method utilizing intensity optical flow
- 13 September 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (18) , 4885-4888
Development of a two-beveled-fiber polarized fiber-optic Raman probe coupled with a ball lens for in vivo superficial epithelial Raman measurements in endoscopy
We report on the development of a two-beveled-fiber polarized (TBFP) fiber-optic Raman probe coupled with a ball lens for in vivo superficial epithelial Raman measurements in endoscopy. The two-beveled fibers positioned symmetrically along a ball lens, in synergy with paired parallel-polarized polarizers integrated between the fibers and the ball lens, maximize the Raman signal excitation and collection from the superficial epithelium where gastrointestinal (GI) precancer arises. Monte Carlo (MC) simulations and two-layer tissue phantom experiments show that the probe developed detects ∼90% of the Raman signal from the superficial epithelium. The suitability of the probe developed for rapid (in vivo superficial epithelial Raman measurements in endoscopy.
- 13 September 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (18) , 4885-4888
Development of a two-beveled-fiber polarized fiber-optic Raman probe coupled with a ball lens for in vivo superficial epithelial Raman measurements in endoscopy
We report on the development of a two-beveled-fiber polarized (TBFP) fiber-optic Raman probe coupled with a ball lens for in vivo superficial epithelial Raman measurements in endoscopy. The two-beveled fibers positioned symmetrically along a ball lens, in synergy with paired parallel-polarized polarizers integrated between the fibers and the ball lens, maximize the Raman signal excitation and collection from the superficial epithelium where gastrointestinal (GI) precancer arises. Monte Carlo (MC) simulations and two-layer tissue phantom experiments show that the probe developed detects ∼90% of the Raman signal from the superficial epithelium. The suitability of the probe developed for rapid (in vivo superficial epithelial Raman measurements in endoscopy.
- 29 August 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (9) , 4990-5004
Development and performance validation of a low-cost algorithms-based hyperspectral imaging system for radiodermatitis assessment
Whilst radiotherapy (RT) is widely used for cancer treatment, radiodermatitis caused by RT is one most common severe side effect affecting 95% cancer patients. Accurate radiodermatitis assessment and classification is essential to adopt timely treatment, management and monitoring, which all depend on reliable and objective tools for radiodermatitis grading. We therefore, in this work, reported the development and grading performance validation of a low-cost (∼2318.2 CNY) algorithms-based hyperspectral imaging (aHSI) system for radiodermatitis assessment. The low-cost aHSI system was enabled through Monte Carlo (MC) simulations conducted on multi-spectra acquired from a custom built low-cost multispectral imaging (MSI) system, deriving algorithms-based hyper-spectra with spectral resolution of 1 nm. The MSI system was based on sequentially illuminated narrow-band light-emitting diodes (LEDs) and a CMOS camera. Erythema induced artificially on healthy volunteers was measured by the aHSI system developed, with algorithms-based hyper-spectra and skin layer resolved physiological parameters (i.e., the blood volume fraction (BVF) and the oxygen saturation of hemoglobin in blood, et. al.) derivation using MC simulations. The MC simulations derived BVF and the oxygen saturation of hemoglobin in blood showed significant (P < 0.001, analysis of variance: ANOVA) increase with erythema. Further 1D-convolution neural network (CNN) implemented on the algorithms-based hyper-spectra leads to an overall classification accuracy of 93.1%, suggesting the great potential of low-cost aHSI system developed for radiodermatitis assessment.
- 29 August 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (9) , 4990-5004
Development and performance validation of a low-cost algorithms-based hyperspectral imaging system for radiodermatitis assessment
Whilst radiotherapy (RT) is widely used for cancer treatment, radiodermatitis caused by RT is one most common severe side effect affecting 95% cancer patients. Accurate radiodermatitis assessment and classification is essential to adopt timely treatment, management and monitoring, which all depend on reliable and objective tools for radiodermatitis grading. We therefore, in this work, reported the development and grading performance validation of a low-cost (∼2318.2 CNY) algorithms-based hyperspectral imaging (aHSI) system for radiodermatitis assessment. The low-cost aHSI system was enabled through Monte Carlo (MC) simulations conducted on multi-spectra acquired from a custom built low-cost multispectral imaging (MSI) system, deriving algorithms-based hyper-spectra with spectral resolution of 1 nm. The MSI system was based on sequentially illuminated narrow-band light-emitting diodes (LEDs) and a CMOS camera. Erythema induced artificially on healthy volunteers was measured by the aHSI system developed, with algorithms-based hyper-spectra and skin layer resolved physiological parameters (i.e., the blood volume fraction (BVF) and the oxygen saturation of hemoglobin in blood, et. al.) derivation using MC simulations. The MC simulations derived BVF and the oxygen saturation of hemoglobin in blood showed significant (P < 0.001, analysis of variance: ANOVA) increase with erythema. Further 1D-convolution neural network (CNN) implemented on the algorithms-based hyper-spectra leads to an overall classification accuracy of 93.1%, suggesting the great potential of low-cost aHSI system developed for radiodermatitis assessment.