Wen Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wen Zhang has a total of 207 co-authors. Here are the top co-authors by number of shared publications:
- Zhaochu Hu
State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan, 430074, PR China
53 shared publications - Yongsheng Liu
State Key Laboratory of Geological Processes and Mineral Resources, School of Earth Sciences, China University of Geosciences, Wuhan 430074, China
22 shared publications Tao Luo
China University of Geosciences
20 shared publicationsZaicong Wang
State Key Laboratory of Geological Processes and Mineral Resources
14 shared publications- Tao Luo
State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan, 430074, PR China
13 shared publications Keqing Zong
State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan, 430074, PR China
10 shared publications
Latest Publications
- 8 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
Sub-20 μm Non-Matrix-Matched U−Pb Dating by LA-Q-ICP-MS Using Pre-Cell Water-Vapor-Assisted Laser Ablation and Quadratic Polynomial Regression Intercept Correction
Accessory-mineral U−Pb geochronology by laser ablation quadrupole inductively coupled plasma mass spectrometry (LA-Q-ICP-MS) provides valuable temporal constraints on Earth and planetary processes. However, its application at sub-20 μm spatial resolution is hindered by matrix-dependent Pb/U downhole fractionation, which compromises the accuracy of non-matrix-matched calibration. Here, xenotime BS-1, allanite AMK, and titanite MKED1 were analyzed at spot sizes of 16 and 10 μm using Tanz zircon as the external calibration reference material. Under dry-ablation, the conventional mean-of-ratios approach produced relative 206Pb/238U ratio biases of 14.2−21.8%, reflecting pronounced matrix-dependent differences in downhole Pb/U fractionation between zircon calibrant and the other accessory minerals. To overcome this limitation, we developed a quadratic polynomial regression intercept method that extrapolates the time-resolved Pb/U fractionation profile to the onset of ablation. The absolute bias reduced to 2.19−11.1% using the quadratic polynomial regression correction under dry ablation conditions. When combined with pre-cell water-vapor-assisted laser ablation, the method enables accurate non-matrix-matched U−Pb dating of xenotime, allanite, and titanite using spot sizes as small as 10 μm, with bias of only 0.05−0.74%. These results establish a practical strategy for routine sub-20 μm multimineral U−Pb geochronology by LA-Q-ICP-MS.
- 8 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
Sub-20 μm Non-Matrix-Matched U−Pb Dating by LA-Q-ICP-MS Using Pre-Cell Water-Vapor-Assisted Laser Ablation and Quadratic Polynomial Regression Intercept Correction
Accessory-mineral U−Pb geochronology by laser ablation quadrupole inductively coupled plasma mass spectrometry (LA-Q-ICP-MS) provides valuable temporal constraints on Earth and planetary processes. However, its application at sub-20 μm spatial resolution is hindered by matrix-dependent Pb/U downhole fractionation, which compromises the accuracy of non-matrix-matched calibration. Here, xenotime BS-1, allanite AMK, and titanite MKED1 were analyzed at spot sizes of 16 and 10 μm using Tanz zircon as the external calibration reference material. Under dry-ablation, the conventional mean-of-ratios approach produced relative 206Pb/238U ratio biases of 14.2−21.8%, reflecting pronounced matrix-dependent differences in downhole Pb/U fractionation between zircon calibrant and the other accessory minerals. To overcome this limitation, we developed a quadratic polynomial regression intercept method that extrapolates the time-resolved Pb/U fractionation profile to the onset of ablation. The absolute bias reduced to 2.19−11.1% using the quadratic polynomial regression correction under dry ablation conditions. When combined with pre-cell water-vapor-assisted laser ablation, the method enables accurate non-matrix-matched U−Pb dating of xenotime, allanite, and titanite using spot sizes as small as 10 μm, with bias of only 0.05−0.74%. These results establish a practical strategy for routine sub-20 μm multimineral U−Pb geochronology by LA-Q-ICP-MS.
- 7 October 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (10) , 3600-3607
In situ Lu–Hf dating of euxenite-(Y) by laser ablation inductively coupled plasma tandem mass spectrometry
We developed a new LA-ICP-MS/MS method for in situ Lu–Hf geochronology of euxenite-(Y).
- 7 October 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (10) , 3600-3607
In situ Lu–Hf dating of euxenite-(Y) by laser ablation inductively coupled plasma tandem mass spectrometry
We developed a new LA-ICP-MS/MS method for in situ Lu–Hf geochronology of euxenite-(Y).
- 2 September 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (9) , 3181-3191
Three natural gypsum and anhydrite reference materials for LA-MC-ICP-MS sulfur isotope analysis
Two natural gypsum (HZC-LX and YS-JC) and one natural anhydrite (14JSD) are presented as reference materials for in situ S isotope analysis.
- 2 September 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (9) , 3181-3191
Three natural gypsum and anhydrite reference materials for LA-MC-ICP-MS sulfur isotope analysis
Two natural gypsum (HZC-LX and YS-JC) and one natural anhydrite (14JSD) are presented as reference materials for in situ S isotope analysis.
- 17 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
High Spatial Resolution In Situ Fe Isotope Analysis by Laser Ablation Collision/Reaction Cell MC-ICP–MS: Application to Chang’e-6 Lunar Samples
Iron (Fe) isotopes act as a powerful tracer in geological processes for analyzing terrestrial and extraterrestrial materials. Laser ablation multicollector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) is widely used for in situ Fe isotope analysis. However, its application is limited by argon (Ar)-based polyatomic isobaric interference and reduced sensitivity under high mass resolution, restricting investigations of intragrain variability and fine-grained extraterrestrial samples. Herein, the first femtosecond LA collision/reaction cell (CRC) MC-ICP-MS analysis for high spatial resolution of Fe isotope is reported. A hydrogen (H2)-helium (He) gas mixture in the CRC effectively suppressed Ar-based interferences, enabling accurate analysis of Fe isotopes in a low-resolution mode. Substitution of the conventional ultraviolet laser with a 1028 nm infrared laser significantly enhanced ablation rates, without compromising the stability of Fe isotope ratios. Optimization of the analytical conditions increased Fe isotope sensitivity by >50-fold than conventional LA-MC-ICP-MS, providing a strong foundation for high spatial resolution analysis. Replicated analyses were performed on six Fe-bearing materials (magnetite, ilmenite, pyrite, chalcopyrite, olivine and basalt glass) using the as-developed method with small beam spots of 8-15 μm in a single-spot mode. The measured δ56FeIRMM-014 values are consistent with reference values, with an external reproducibility of 0.09‰-0.15‰ (2SD). Compared with traditional Fe isotope microanalysis techniques, the proposed method improves spatial resolution of the analytical area by 1-2 orders of magnitude. The method was further applied to impact glass, ilmenite, and olivine samples collected by China's Chang'e-6 lunar missions, revealing significant intraparticle Fe isotope variability at micrometer scales, indicating the capability of LA-CRC-MC-ICP-MS to resolve Fe isotope heterogeneity in fine-grained samples with complex compositions. Thus, our method highlights its potential for high spatial resolution of isotopes in planetary samples.
- 17 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
High Spatial Resolution In Situ Fe Isotope Analysis by Laser Ablation Collision/Reaction Cell MC-ICP–MS: Application to Chang’e-6 Lunar Samples
Iron (Fe) isotopes act as a powerful tracer in geological processes for analyzing terrestrial and extraterrestrial materials. Laser ablation multicollector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) is widely used for in situ Fe isotope analysis. However, its application is limited by argon (Ar)-based polyatomic isobaric interference and reduced sensitivity under high mass resolution, restricting investigations of intragrain variability and fine-grained extraterrestrial samples. Herein, the first femtosecond LA collision/reaction cell (CRC) MC-ICP-MS analysis for high spatial resolution of Fe isotope is reported. A hydrogen (H2)-helium (He) gas mixture in the CRC effectively suppressed Ar-based interferences, enabling accurate analysis of Fe isotopes in a low-resolution mode. Substitution of the conventional ultraviolet laser with a 1028 nm infrared laser significantly enhanced ablation rates, without compromising the stability of Fe isotope ratios. Optimization of the analytical conditions increased Fe isotope sensitivity by >50-fold than conventional LA-MC-ICP-MS, providing a strong foundation for high spatial resolution analysis. Replicated analyses were performed on six Fe-bearing materials (magnetite, ilmenite, pyrite, chalcopyrite, olivine and basalt glass) using the as-developed method with small beam spots of 8-15 μm in a single-spot mode. The measured δ56FeIRMM-014 values are consistent with reference values, with an external reproducibility of 0.09‰-0.15‰ (2SD). Compared with traditional Fe isotope microanalysis techniques, the proposed method improves spatial resolution of the analytical area by 1-2 orders of magnitude. The method was further applied to impact glass, ilmenite, and olivine samples collected by China's Chang'e-6 lunar missions, revealing significant intraparticle Fe isotope variability at micrometer scales, indicating the capability of LA-CRC-MC-ICP-MS to resolve Fe isotope heterogeneity in fine-grained samples with complex compositions. Thus, our method highlights its potential for high spatial resolution of isotopes in planetary samples.
- 28 May 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (7) , 2443-2454
SP-IM and SP-SP: two potential natural sphalerite reference materials for in situ Zn and S isotope analysis by LA-MC-ICP-MS
SP-IM and SP-SP are natural sphalerite candidate reference materials for in situ Zn and S isotope analysis by fs-LA-MC-ICP-MS, exhibiting stable ablation behaviour, good isotopic homogeneity, and reproducible Zn and S isotope compositions.
- 28 May 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (7) , 2443-2454
SP-IM and SP-SP: two potential natural sphalerite reference materials for in situ Zn and S isotope analysis by LA-MC-ICP-MS
SP-IM and SP-SP are natural sphalerite candidate reference materials for in situ Zn and S isotope analysis by fs-LA-MC-ICP-MS, exhibiting stable ablation behaviour, good isotopic homogeneity, and reproducible Zn and S isotope compositions.
- 10 April 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (5) , 1641-1650
Preparation of rutile reference materials for in situ elemental and Hf–Ti isotopic microanalysis using spark plasma sintering
The use of ultrafine powders combined with SPS techniques is proposed as an ideal protocol for preparing rutile reference materials for in situ elemental and isotopic analysis.
- 10 April 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (5) , 1641-1650
Preparation of rutile reference materials for in situ elemental and Hf–Ti isotopic microanalysis using spark plasma sintering
The use of ultrafine powders combined with SPS techniques is proposed as an ideal protocol for preparing rutile reference materials for in situ elemental and isotopic analysis.
- 30 March 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (14) , 10738-10749
LA-TReQNet: Improving Multielement Quantification Model for Laser Ablation Inductively Coupled Plasma Mass Spectrometry Based on Deep Learning Network
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP–MS) is a widely used quantitative technique. However, conventional calibration approaches that depend on internal standards, external reference materials, and linear regression are subject to practical limitations. To address these challenges, we present LA-TReQNet, an end-to-end deep learning framework, that enables fully automated quantitative calibration in LA-ICP–MS. A CNN-LSTM architecture was trained on a data set of 221,364 labeled mass spectra from 5676 samples. We demonstrate that preprocessing of mass spectrometry data substantially impacts model performance and propose an optimized strategy incorporating power transformer-based standardization and data set grouping. By training on extensive multielement data sets, the deep learning model captures complex empirical relationships, thus establishing for the first time a standard-free calibration approach. The optimized LA-TReQNet model accurately quantified 39 elements in three RMs (BCR-2G, BHVO-2G, and BIR-1G) from independent laboratories, confirming its robustness to data source variations. When applied to a broader set of RMs, LA-TReQNet achieved deviations of 0.2% ± 5.8% (SD, n = 198) for major elements and −0.9% ± 9.2% (SD, n = 898) for trace elements relative to certified reference values. The results confirm that deep learning-based elemental quantification achieves accuracy on par with conventional approaches while eliminating the reliance on internal or external standards, thus significantly expanding the applicability of LA-ICP–MS to complex and diverse samples. Moreover, LA-TReQNet eliminates data quality fluctuations from researcher experience differences in traditional handling, improving both processing efficiency and result stability.
- 30 March 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (14) , 10738-10749
LA-TReQNet: Improving Multielement Quantification Model for Laser Ablation Inductively Coupled Plasma Mass Spectrometry Based on Deep Learning Network
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP–MS) is a widely used quantitative technique. However, conventional calibration approaches that depend on internal standards, external reference materials, and linear regression are subject to practical limitations. To address these challenges, we present LA-TReQNet, an end-to-end deep learning framework, that enables fully automated quantitative calibration in LA-ICP–MS. A CNN-LSTM architecture was trained on a data set of 221,364 labeled mass spectra from 5676 samples. We demonstrate that preprocessing of mass spectrometry data substantially impacts model performance and propose an optimized strategy incorporating power transformer-based standardization and data set grouping. By training on extensive multielement data sets, the deep learning model captures complex empirical relationships, thus establishing for the first time a standard-free calibration approach. The optimized LA-TReQNet model accurately quantified 39 elements in three RMs (BCR-2G, BHVO-2G, and BIR-1G) from independent laboratories, confirming its robustness to data source variations. When applied to a broader set of RMs, LA-TReQNet achieved deviations of 0.2% ± 5.8% (SD, n = 198) for major elements and −0.9% ± 9.2% (SD, n = 898) for trace elements relative to certified reference values. The results confirm that deep learning-based elemental quantification achieves accuracy on par with conventional approaches while eliminating the reliance on internal or external standards, thus significantly expanding the applicability of LA-ICP–MS to complex and diverse samples. Moreover, LA-TReQNet eliminates data quality fluctuations from researcher experience differences in traditional handling, improving both processing efficiency and result stability.
- 4 March 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (4) , 1517-1527
Characterization of a new zircon reference material (TGZ) with substantial reserve for in situ U-Pb and Hf-O isotope analysis
A new zircon reference material (TGZ) with substantial reserves and ready availability is proposed for in situ U-Pb dating and Hf-O isotope analysis.
- 4 March 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (4) , 1517-1527
Characterization of a new zircon reference material (TGZ) with substantial reserve for in situ U-Pb and Hf-O isotope analysis
A new zircon reference material (TGZ) with substantial reserves and ready availability is proposed for in situ U-Pb dating and Hf-O isotope analysis.
- 4 February 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (4) , 1305-1315
Three natural zircon reference materials for in situ Hf isotope analysis covering a wide range of 176 Yb/ 177 Hf ratios
Three potential natural zircon reference materials span a wide 176 Yb/ 177 Hf range for high precision in situ Hf isotope analysis.
- 4 February 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (4) , 1305-1315
Three natural zircon reference materials for in situ Hf isotope analysis covering a wide range of 176 Yb/ 177 Hf ratios
Three potential natural zircon reference materials span a wide 176 Yb/ 177 Hf range for high precision in situ Hf isotope analysis.
- 4 February 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (4) , 1298-1304
Rapid in situ laser digestion for high-precision barium isotope analysis of barite using double spike MC-ICP-MS
A rapid in situ laser digestion technique combined with double spike MC-ICP-MS for a high-precision and high-spatial-resolution isotopic analysis method in insoluble geological minerals.
- 4 February 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (4) , 1298-1304
Rapid in situ laser digestion for high-precision barium isotope analysis of barite using double spike MC-ICP-MS
A rapid in situ laser digestion technique combined with double spike MC-ICP-MS for a high-precision and high-spatial-resolution isotopic analysis method in insoluble geological minerals.