Bogdan Milićević
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bogdan Milićević has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Miljan Milosevic
Institute for Information Technologies, University of Kragujevac, Jovana Cvijica bb, 34000 Kragujevac, Serbia
19 shared publications - Nenad Filipovic
Faculty of Engineering, University of Kragujevac, Sestre Janjić 6, 34000 Kragujevac, Serbia
17 shared publications - Vladimir Simic
Faculty of Transport and Traffic Engineering, University of Belgrade, Vojvode Stepe 305, 11010 Belgrade, Serbia
15 shared publications - Milos Kojic
Bioengineering Research and Development Center BioIRC Kragujevac, Kragujevac, Serbia
9 shared publications - Carly Sue Filgueira
Center for BioNanoengineering, Houston Methodist Research Institute, 6670 Bertner Ave, Houston, TX 77030, USA
4 shared publications Miloš Kojić
Bioengineering Research and Development Center (BioIRC)
4 shared publications
Latest Publications
- 14 November 2026
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 48 (17) , 699
Factors associated with radon occurrence in drinking water in Montenegro: a statistical and machine learning approach
- 14 November 2026
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 48 (17) , 699
Factors associated with radon occurrence in drinking water in Montenegro: a statistical and machine learning approach
- Open Access
- 27 October 2026
- Published by MDPI AG in Computation
- Vol. 14 (11) , 264
Reconstruction of Left Ventricle Geometry for Finite Element Analysis Using 2D Echocardiography
Patient-specific finite element (FE) analysis of left ventricular (LV) mechanics requires a geometric model that is discretized for computation, a step that in current practice still involves considerable manual work. Because two-dimensional (2D) echocardiography is the most widely used modality for assessing LV function, we present an algorithm that converts segmented apical 2D views (one to three imaging planes) directly into a structured, layered hexahedral FE mesh controlled by three LV-specific parameters: the axial and circular divisions and the number of transmural element layers. All models generated with the same parameters share one mesh topology, so node-to-node correspondence across cardiac phases is obtained by construction and tracked endocardial motion can be imposed directly as a boundary condition. On analytical phantoms with known 3D geometry, reconstruction from three apical views reproduced the cavity volume to within 2.1% (biplane Simpson method: up to 10.8%), with a mean surface distance of 0.6–0.9 mm at a pixel size of 0.8 mm and a Dice coefficient of 0.95–0.98; reconstruction from a single view underestimated the volume by 5–20%, depending on the ellipticity of the cross-section. Applied to 36 segmented EchoNet-Dynamic images, the pipeline produced valid meshes (all elements with a positive Jacobian) in every case and at every resolution, in less than 0.2 s per model. A generic marching-cubes/TetGen route applied to the same geometry produced different node counts at end-diastole and end-systole and contained sliver elements. In a passive-filling problem (human Holzapfel–Ogden myocardium with rule-based fibers, end-diastolic pressure 8 mmHg), cavity volume, wall thickness, apex displacement, fiber strain and fiber stress changed by at most 0.8% between the 24 × 48 and the 36 × 72 surface divisions. The method therefore provides fast, controllable and FE-ready LV geometries from routine echocardiography, with an accuracy that is limited mainly by the number of available views and by the segmentation.
- 27 October 2026
- Published by MDPI AG in Computation
- Vol. 14 (11) , 264
Open AccessReconstruction of Left Ventricle Geometry for Finite Element Analysis Using 2D Echocardiography
Patient-specific finite element (FE) analysis of left ventricular (LV) mechanics requires a geometric model that is discretized for computation, a step that in current practice still involves considerable manual work. Because two-dimensional (2D) echocardiography is the most widely used modality for assessing LV function, we present an algorithm that converts segmented apical 2D views (one to three imaging planes) directly into a structured, layered hexahedral FE mesh controlled by three LV-specific parameters: the axial and circular divisions and the number of transmural element layers. All models generated with the same parameters share one mesh topology, so node-to-node correspondence across cardiac phases is obtained by construction and tracked endocardial motion can be imposed directly as a boundary condition. On analytical phantoms with known 3D geometry, reconstruction from three apical views reproduced the cavity volume to within 2.1% (biplane Simpson method: up to 10.8%), with a mean surface distance of 0.6–0.9 mm at a pixel size of 0.8 mm and a Dice coefficient of 0.95–0.98; reconstruction from a single view underestimated the volume by 5–20%, depending on the ellipticity of the cross-section. Applied to 36 segmented EchoNet-Dynamic images, the pipeline produced valid meshes (all elements with a positive Jacobian) in every case and at every resolution, in less than 0.2 s per model. A generic marching-cubes/TetGen route applied to the same geometry produced different node counts at end-diastole and end-systole and contained sliver elements. In a passive-filling problem (human Holzapfel–Ogden myocardium with rule-based fibers, end-diastolic pressure 8 mmHg), cavity volume, wall thickness, apex displacement, fiber strain and fiber stress changed by at most 0.8% between the 24 × 48 and the 36 × 72 surface divisions. The method therefore provides fast, controllable and FE-ready LV geometries from routine echocardiography, with an accuracy that is limited mainly by the number of available views and by the segmentation.
- Open Access
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Tehnika
- Vol. 81 (4) , 373-380
Solar incident angles for flat surfaces equipped with different single-axis sun tracking strategies
This paper presents theoretical models for determining solar incidence angles for flat surfaces (flat solar devices) equipped with the following single-axis tracking strategies for the position of the Sun: horizontal (1) E-W and (2) N-S rotation axes, (3) inclined N-S rotation axes, (4) polar (the angle of inclination of flat surfaces to the horizontal plane corresponds to the value of the local latitude) N-S rotation axes, as well as vertical rotation axes when flat surfaces are (5) orthogonal and (6) inclined to the horizontal plane. Although the above strategies are widespread, they do not have the same performance, so it is necessary to highlight their advantages and disadvantages through mutual comparison. This provides the necessary information to properly dimension solar devices for given location parameters, available space for installation, time of day and tracking step.
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Tehnika
- Vol. 81 (4) , 373-380
Open AccessSolar incident angles for flat surfaces equipped with different single-axis sun tracking strategies
This paper presents theoretical models for determining solar incidence angles for flat surfaces (flat solar devices) equipped with the following single-axis tracking strategies for the position of the Sun: horizontal (1) E-W and (2) N-S rotation axes, (3) inclined N-S rotation axes, (4) polar (the angle of inclination of flat surfaces to the horizontal plane corresponds to the value of the local latitude) N-S rotation axes, as well as vertical rotation axes when flat surfaces are (5) orthogonal and (6) inclined to the horizontal plane. Although the above strategies are widespread, they do not have the same performance, so it is necessary to highlight their advantages and disadvantages through mutual comparison. This provides the necessary information to properly dimension solar devices for given location parameters, available space for installation, time of day and tracking step.
- Open Access
- 1 October 2025
- Published by Faculty of Engineering, University of Kragujevac in Journal of the Serbian Society for Computational Mechanics
- Vol. 19 (1) , 451-462
COMPUTATIONAL MODELING OF DRUG TRANSPORT AND PERFUSION WITHIN COMPLEX BIOLOGICAL SYSTEMS AND GROWING TUMORS
Journal sscm, jsscm, journal of the serbia society for computational mechanics, mechanics, serbia mechanics, journal
- 1 October 2025
- Published by Faculty of Engineering, University of Kragujevac in Journal of the Serbian Society for Computational Mechanics
- Vol. 19 (1) , 451-462
Open AccessCOMPUTATIONAL MODELING OF DRUG TRANSPORT AND PERFUSION WITHIN COMPLEX BIOLOGICAL SYSTEMS AND GROWING TUMORS
Journal sscm, jsscm, journal of the serbia society for computational mechanics, mechanics, serbia mechanics, journal
- Open Access
- 27 August 2025
- Published by National and University Library of the Republic of Srpska in Contemporary Materials
- Vol. 16 (1) , 12-19
OVERVIEW OF THE ELECTROPHYSIOLOGICAL MODELS FOR THE LEFT VENTRICLE SIMULATIONS
Electrophysiological models play a crucial role in understanding the complex dynamics of the heart, particularly the left ventricle. These models provide insights into the mechanisms underlying cardiac function and are essential for developing treatments for cardiac diseases. This paper presents an overview of various electrophysiological models used for simulating the left ventricle, including the van der Pol oscillator, the FitzHugh-Nagumo model, the Luo-Rudy model, and the O’Hara-Rudy model. By exploring the historical development, applications, and future directions of these models, this paper aims to highlight their significance and potential in advancing cardiac research and clinical practice.
- 27 August 2025
- Published by National and University Library of the Republic of Srpska in Contemporary Materials
- Vol. 16 (1) , 12-19
Open AccessOVERVIEW OF THE ELECTROPHYSIOLOGICAL MODELS FOR THE LEFT VENTRICLE SIMULATIONS
Electrophysiological models play a crucial role in understanding the complex dynamics of the heart, particularly the left ventricle. These models provide insights into the mechanisms underlying cardiac function and are essential for developing treatments for cardiac diseases. This paper presents an overview of various electrophysiological models used for simulating the left ventricle, including the van der Pol oscillator, the FitzHugh-Nagumo model, the Luo-Rudy model, and the O’Hara-Rudy model. By exploring the historical development, applications, and future directions of these models, this paper aims to highlight their significance and potential in advancing cardiac research and clinical practice.
- 18 July 2025
- Published by Springer Nature
- p. 74-80
Overview of the Integration of Genetic Algorithms and Reinforcement Learning Techniques
- 18 July 2025
- Published by Springer Nature
- p. 74-80
Overview of the Integration of Genetic Algorithms and Reinforcement Learning Techniques
- Open Access
- 12 October 2024
- Published by MDPI AG in Pharmaceuticals
- Vol. 17 (10) , 1364
A Machine Learning Approach to Gene Expression in Hypertrophic Cardiomyopathy
Background/Objectives: Hypertrophic cardiomyopathy (HCM) is a common heart disorder characterized by the thickening of the heart muscle, particularly in the left ventricle, which increases the risk of cardiac complications. This study aims to analyze the expression of apoptosis-regulating genes (CASP8, CASP9, CASP3, BAX, and BCL2) in blood samples from HCM patients, to better understand their potential as biomarkers for disease progression. Methods: Quantitative real-time PCR (qPCR) was used to evaluate gene expression in blood samples from 93 HCM patients. The correlation between apoptosis-regulating genes was conducted and clinical parameters were integrated for feature importance and clustering analysis. Results: Most patients exhibited significant downregulation of CASP8, CASP9, and CASP3. In contrast, BAX expression was elevated in 71 out of 93 patients, while BCL2 was increased in 55 out of 93 patients. Correlation analysis revealed weak negative correlations between the BAX/BCL2 ratio and CASP gene expression. Conclusions: These findings suggest that reduced expression of apoptotic genes may indicate a protective cellular mechanism, which could serve as a biomarker for disease progression. Further studies are needed to investigate the potential for therapeutic modulation of these pathways to improve patient outcomes.
- 12 October 2024
- Published by MDPI AG in Pharmaceuticals
- Vol. 17 (10) , 1364
Open AccessA Machine Learning Approach to Gene Expression in Hypertrophic Cardiomyopathy
Background/Objectives: Hypertrophic cardiomyopathy (HCM) is a common heart disorder characterized by the thickening of the heart muscle, particularly in the left ventricle, which increases the risk of cardiac complications. This study aims to analyze the expression of apoptosis-regulating genes (CASP8, CASP9, CASP3, BAX, and BCL2) in blood samples from HCM patients, to better understand their potential as biomarkers for disease progression. Methods: Quantitative real-time PCR (qPCR) was used to evaluate gene expression in blood samples from 93 HCM patients. The correlation between apoptosis-regulating genes was conducted and clinical parameters were integrated for feature importance and clustering analysis. Results: Most patients exhibited significant downregulation of CASP8, CASP9, and CASP3. In contrast, BAX expression was elevated in 71 out of 93 patients, while BCL2 was increased in 55 out of 93 patients. Correlation analysis revealed weak negative correlations between the BAX/BCL2 ratio and CASP gene expression. Conclusions: These findings suggest that reduced expression of apoptotic genes may indicate a protective cellular mechanism, which could serve as a biomarker for disease progression. Further studies are needed to investigate the potential for therapeutic modulation of these pathways to improve patient outcomes.
- Open Access
- 30 July 2024
- Published by MDPI AG in Pharmaceutics
- Vol. 16 (8) , 1009
An Insight into Perfusion Anisotropy within Solid Murine Lung Cancer Tumors
Blood vessels are essential for maintaining tumor growth, progression, and metastasis, yet the tumor vasculature is under a constant state of remodeling. Since the tumor vasculature is an attractive therapeutic target, there is a need to predict the dynamic changes in intratumoral fluid pressure and velocity that occur across the tumor microenvironment (TME). The goal of this study was to obtain insight into perfusion anisotropy within lung tumors. To achieve this goal, we used the perfusion marker Hoechst 33342 and vascular endothelial marker CD31 to stain tumor sections from C57BL/6 mice harboring Lewis lung carcinoma tumors on their flank. Vasculature, capillary diameter, and permeability distribution were extracted at different time points along the tumor growth curve. A computational model was generated by applying a unique modeling approach based on the smeared physical fields (Kojic Transport Model, KTM). KTM predicts spatial and temporal changes in intratumoral pressure and fluid velocity within the growing tumor. Anisotropic perfusion occurs within two domains: capillary and extracellular space. Anisotropy in tumor structure causes the nonuniform distribution of pressure and fluid velocity. These results provide insights regarding local vascular distribution for optimal drug dosing and delivery to better predict distribution and duration of retention within the TME.
- 30 July 2024
- Published by MDPI AG in Pharmaceutics
- Vol. 16 (8) , 1009
Open AccessAn Insight into Perfusion Anisotropy within Solid Murine Lung Cancer Tumors
Blood vessels are essential for maintaining tumor growth, progression, and metastasis, yet the tumor vasculature is under a constant state of remodeling. Since the tumor vasculature is an attractive therapeutic target, there is a need to predict the dynamic changes in intratumoral fluid pressure and velocity that occur across the tumor microenvironment (TME). The goal of this study was to obtain insight into perfusion anisotropy within lung tumors. To achieve this goal, we used the perfusion marker Hoechst 33342 and vascular endothelial marker CD31 to stain tumor sections from C57BL/6 mice harboring Lewis lung carcinoma tumors on their flank. Vasculature, capillary diameter, and permeability distribution were extracted at different time points along the tumor growth curve. A computational model was generated by applying a unique modeling approach based on the smeared physical fields (Kojic Transport Model, KTM). KTM predicts spatial and temporal changes in intratumoral pressure and fluid velocity within the growing tumor. Anisotropic perfusion occurs within two domains: capillary and extracellular space. Anisotropy in tumor structure causes the nonuniform distribution of pressure and fluid velocity. These results provide insights regarding local vascular distribution for optimal drug dosing and delivery to better predict distribution and duration of retention within the TME.
- 28 July 2024
- Published by Springer Nature
- p. 363-398
Use Case: AI-Based Surrogate Muscle Models for Cardiac Cycle Simulations of the Left Ventricle
- 28 July 2024
- Published by Springer Nature
- p. 363-398
Use Case: AI-Based Surrogate Muscle Models for Cardiac Cycle Simulations of the Left Ventricle
- Open Access
- 26 June 2024
- Published by MDPI AG in Preprints.org
An Insight into Perfusion Anisotropy within Solid Murine Lung Cancer Tumors
Blood vessels are essential for maintaining tumor growth, progression, and metastasis, yet the tumor vasculature is under a constant state of remodeling. Since the tumor vasculature is an attractive therapeutic target, there is a need to predict the dynamic changes in intratumoral fluid pressure and velocity which occur across the tumor microenvironment (TME). The goal of this study is to get insight into perfusion anisotropy within lung tumors. To achieve this goal, we used the perfusion marker Hoechst 33342 and vascular endothelial marker CD31 to stain tumor sections from C57BL/6 mice harboring Lewis Lung Carcinoma tumors on their flank. Vasculature, capillary diameter, and permeability distribution were extracted at different time points along the tumor growth curve. A computational model was generated applying a unique modeling approach based on the smeared physical fields (Kojic Transport Model, KTM). KTM predicts spatial and temporal changes in intratumoral pressure and fluid velocity within the growing tumor. Anisotropic perfusion occurs within two domains - capillary and extracellular space. Anisotropy in tumor structure causes nonuniform distribution of pressure and fluid velocity. These results provide insights regarding local vascular distribution for optimal drug dosing and delivery to better predict distribution and duration of retention within the TME.
- 26 June 2024
- Published by MDPI AG in Preprints.org
Open AccessAn Insight into Perfusion Anisotropy within Solid Murine Lung Cancer Tumors
Blood vessels are essential for maintaining tumor growth, progression, and metastasis, yet the tumor vasculature is under a constant state of remodeling. Since the tumor vasculature is an attractive therapeutic target, there is a need to predict the dynamic changes in intratumoral fluid pressure and velocity which occur across the tumor microenvironment (TME). The goal of this study is to get insight into perfusion anisotropy within lung tumors. To achieve this goal, we used the perfusion marker Hoechst 33342 and vascular endothelial marker CD31 to stain tumor sections from C57BL/6 mice harboring Lewis Lung Carcinoma tumors on their flank. Vasculature, capillary diameter, and permeability distribution were extracted at different time points along the tumor growth curve. A computational model was generated applying a unique modeling approach based on the smeared physical fields (Kojic Transport Model, KTM). KTM predicts spatial and temporal changes in intratumoral pressure and fluid velocity within the growing tumor. Anisotropic perfusion occurs within two domains - capillary and extracellular space. Anisotropy in tumor structure causes nonuniform distribution of pressure and fluid velocity. These results provide insights regarding local vascular distribution for optimal drug dosing and delivery to better predict distribution and duration of retention within the TME.