Robert Scharf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Robert Scharf has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Christopher Reiche
Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, United States
2 shared publicationsEnyuan Xie
Institute of Photonics, Dept. of Physics, SUPA, University of Strathclyde, Glasgow G4 0NW, UK
2 shared publications- Keith Mathieson
University of Strathclyde
2 shared publications - Niall McAlinden
Institute of Photonics, Dept. of Physics, University of Strathclyde, Glasgow, UK
2 shared publications Rohit Sharma
Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, United States
2 shared publications- Yunzhou Cheng
Institute of Photonics, Dept. of Physics, SUPA, University of Strathclyde, Glasgow G4 0NW, UK
2 shared publications
Latest Publications
- Open Access
A multi-site MicroLED Optrode Array for Neural Interfacing
We present an electrically addressable optrode array capable of delivering light to 181 sites in the brain, each providing sufficient light to optogenetically excite hundreds of neurons in vivo , developed with the aim to allow behavioural studies in large mammals. The device is a glass microneedle array directly integrated with a custom fabricated microLED device, which delivers light to 100 needle tips and 81 interstitial surface sites, giving 2-level optogenetic excitation of neurons in vivo . Light delivery and thermal properties are evaluated, with the device capable of peak irradiances > 80 mW/mm 2 per needle at 50 ms pulse widths with tissue temperature increase less than 1 ° C. Future designs are explored through optical and thermal modelling and benchmarked against the current device.
Open AccessA multi-site MicroLED Optrode Array for Neural Interfacing
We present an electrically addressable optrode array capable of delivering light to 181 sites in the brain, each providing sufficient light to optogenetically excite hundreds of neurons in vivo , developed with the aim to allow behavioural studies in large mammals. The device is a glass microneedle array directly integrated with a custom fabricated microLED device, which delivers light to 100 needle tips and 81 interstitial surface sites, giving 2-level optogenetic excitation of neurons in vivo . Light delivery and thermal properties are evaluated, with the device capable of peak irradiances > 80 mW/mm 2 per needle at 50 ms pulse widths with tissue temperature increase less than 1 ° C. Future designs are explored through optical and thermal modelling and benchmarked against the current device.
- 1 January 2018
- Published by Optica Publishing Group
- p. JW3A.57
Refined Utah Optrode Array and µLED Array for Deep Cortical Optogenetic Stimulation in Primates
We fabricated a deep optogenetic cortical stimulation device (10×10 glass waveguide array) using wafer dicing, etching and annealing. A µLED array delivers light through individual shanks. A silicon interposer layer with optical vias prevents crosstalk.
- 1 January 2018
- Published by Optica Publishing Group
- p. JW3A.57
Refined Utah Optrode Array and µLED Array for Deep Cortical Optogenetic Stimulation in Primates
We fabricated a deep optogenetic cortical stimulation device (10×10 glass waveguide array) using wafer dicing, etching and annealing. A µLED array delivers light through individual shanks. A silicon interposer layer with optical vias prevents crosstalk.