DWDaodang Wang

Daodang Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daodang Wang has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dual-mode on-machine metrology for SPDT tool alignment

    by Wenjun Kang, Yihan Wang, Hongzhang Ma, Daodang Wang, Rongguang Liang


  • Low-coherence snapshot phase-shifting diffraction phase microscope

    by Yuanyuan Sun, Yihan Wang, Daodang Wang, Stanley Pau, Rongguang Liang


  • On-axis deflectometric system for freeform surface measurement

    by Shengtai Zhu, Daodang Wang, Wenjun Kang, Rongguang Liang

    We propose an on-axis deflectometric system for the accurate measurement of freeform surfaces with large slope ranges. A miniature plane mirror is attached on the illumination screen to fold the optical path and achieve the on-axis deflectometric testing. Due to the existence of the miniature folding mirror, the deep-learning method is applied to recover the missing surface data in a single measurement. Low sensitivity to the calibration error of system geometry and high testing accuracy can be achieved with the proposed system. The feasibility and accuracy of the proposed system have been validated. The system is low in cost and simple in configuration, and it provides a feasible way for the flexible and general testing of freeform surfaces, with a significant potential of the application in on-machine testing.


  • Open Access

    Experimental Studies on Fabricating Lenslet Array with Slow Tool Servo

    by Wenjun Kang, Masafumi Seigo, Huapan Xiao, Daodang Wang, Rongguang Liang

    On the demand of low-cost, lightweight, miniaturized, and integrated optical systems, precision lenslet arrays are widely used. Diamond turning is often used to fabricate lenslet arrays directly or molds that are used to mold lenslet arrays. In this paper, mainly by real-time monitoring position following error for slow tool servo, different fabrication parameters are quantitatively studied and optimized for actual fabrication, then by actual fabrication validation, uniform and high-fidelity surface topography across the actual whole lenslet array is achieved. The evaluated fabrication parameters include sampling strategy, inverse time feed, arc-length, etc. The study provides a quick, effective, and detailed reference for both convex and concave lenslet array cutting parameter selection. At the end, a smooth zonal machining strategy toolpath is demonstrated for fabricating concave lenslet arrays.


  • Design and error calibration of an on-axis deflectometric microscope system

    by Zhixiong Gu, Daodang Wang, Yang Ruan, Ming Kong, Xinke Xu, Rongguang Liang

    An on-axis deflectometric microscope system (ODMS) is proposed for the microscopic surface measurement with high accuracy and a large slope dynamic range. To reduce the geometry sensitivity, a beam splitter is employed to build the coaxial configuration among the illumination screen, camera, and tested sample, which facilitates the calibration of system geometrical parameters. Due to the small working distance, the system model miscalibration in the model-ray-tracing-based “null” testing could cause obvious geometrical aberrations. In this paper, the geometrical aberrations due to the system model miscalibration are analyzed, and the corresponding calibration method based on computer-aided reverse optimization is applied to achieve accurate measurement. In addition, the systematic error introduced by the system components in the ODMS are also discussed. Both the simulation and experiment have been carried out to demonstrate the feasibility and high accuracy of the proposed measurement method. The proposed system is compact in structure, large in measurable slope range, and high in spatial resolution, providing a viable metrological tool for the microscopic testing of various freeform surfaces, microstructural elements, and micro-devices.


  • Deep-learning-based deflectometry for freeform surface measurement

    by Jinchao Dou, Daodang Wang, Qiuye Yu, Ming Kong, Lu Liu, Xinke Xu, Rongguang Liang

    We propose a deep-learning based deflectometric method for freeform surface measurement, in which a deep neural network is devised for freeform surface reconstruction. Full-scale skip connections are adopted in the network architecture to extract and incorporate multi-scale feature maps from different layers, enabling the accuracy and robustness of the testing system to be greatly enhanced. The feasibility of the proposed method is numerically and experimentally validated, and its excellent performance in terms of accuracy and robustness is also demonstrated. The proposed method provides a feasible way to achieve the general measurement of freeform surfaces while minimizing the measurement errors due to noise and system geometry calibration.


  • Open Access

    Error Analysis of the Combined-Scan High-Speed Atomic Force Microscopy

    by Lu Liu, Ming Kong, Sen Wu, Xinke Xu, Daodang Wang

    A combined tip-sample scanning architecture can improve the imaging speed of atomic force microscopy (AFM). However, the nonorthogonality between the three scanners and the nonideal response of each scanner cause measurement errors. In this article, the authors systematically analyze the influence of the installation and response errors of the combined scanning architecture. The experimental results show that when the probe in the homemade high-speed AFM moves with the Z-scanner, the spot position on the four-quadrant detector changes, thus introducing measurement error. Comparing the experimental results with the numerical and theoretical results shows that the undesired motion of the Z-scanner introduces a large error. The authors believe that this significant error occurs because the piezoelectric actuator not only stretches along the polarization direction but also swings under nonuniform multifield coupling. This article proposes a direction for further optimizing the instrument and provides design ideas for similar high-speed atomic force microscopes.


  • High-accuracy deflectometric microscope system with a large slope range

    by Hanting Gu, Daodang Wang, Zhixiong Gu, Ming Kong, Lu Liu, Lihua Lei, Rongguang Liang

    We propose an off-axis deflectometric microscope system for microscopic surface testing with both high measurement accuracy and a large slope dynamic range. A high-luminance liquid crystal display directly illuminates the tested sample with coded fringes, and then the reflected fringes passing through a microscope objective are captured by a pinhole camera, from which the deflectometric microscopic testing with a large slope range can be achieved. The accuracy of the proposed system is validated numerically and experimentally, and a large measurable slope dynamic range is also demonstrated. The proposed system provides a feasible way with the slope range in the order of sub-radians and sag resolution better than 0.05 nm.


  • Calibration of geometrical aberration in transmitted wavefront testing of refractive optics with deflectometry

    by Daodang Wang, Yamei Yin, Jinchao Dou, Ming Kong, Xinke Xu, Lihua Lei, Rongguang Liang

    Deflectometry, with its noticeable advantages such as simple structure, large dynamic range, and high accuracy comparable to interferometry, has been one of the powerful metrological techniques for optical surfaces in recent years. In the “null” deflectometric transmitted wavefront testing of refractive optics, ray tracing of the test system model is required, in which both the miscalibration of system geometrical parameters and optical tolerances on tested optics could introduce significant geometrical aberrations in the testing results. In this paper, the geometrical aberration introduced by a system modeling error in the transmitted wavefront testing is discussed. Besides, a calibration method based on polynomial optimization of geometrical aberration is presented for the geometrical aberration calibration. Both simulation and experiment have been performed to validate the feasibility of the proposed calibration method. The proposed method can calibrate the optical tolerances on tested optics effectively, and it is feasible even with a large geometric error, providing a viable way to address the uncertainty in system modeling in transmitted wavefront testing of freeform refractive optics with large dynamic range.


  • Compact snapshot dual-mode interferometric system for on-machine measurement

    by Daodang Wang, Xiangyu Fu, Ping Xu, Xiaobo Tian, Oliver Spires, Jian Liang, Heng Wu, Rongguang Liang