IKInnokenty Kantor

Innokenty Kantor

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Innokenty Kantor has a total of 491 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effective source size measurement at the 3 GeV storage ring of the MAX IV synchrotron with a grating interferometer

    by Benjamin van Dijk, Robin Krüger, Innokenty Kantor, Martin Bech

    The transverse spatial coherence of synchrotron X-ray beams is a key parameter for many modern imaging and diffraction techniques. In this work, a Talbot grating interferometer was used to characterize the effective transverse coherence at the DanMAX beamline at the MAX IV synchrotron. Interference patterns were recorded at multiple propagation distances using an array of π/2-phase-shifting circular structures, and the visibility of the interference fringes was extracted through Fourier analysis. The measured visibility decay was compared with a theoretical model based on the Van Cittert–Zernike theorem and the Talbot effect in order to estimate the effective source size and coherence properties of the beamline. The horizontal coherence measurements were found to be consistent with the expected source size of the synchrotron source. In contrast, the vertical visibility exhibited significant fluctuations that prevented reliable fitting of the effective source size. These fluctuations suggest that the interferometer is sensitive to temporal variations in beam stability and coherence. The results demonstrate that grating interferometry provides a simple and robust method for coherence characterization at fourth-generation synchrotron facilities and may additionally serve as a diagnostic tool for monitoring beam stability over time.

  • Open Access

    DanMAX – a beamline for materials science using powder X-ray diffraction, total scattering, and full-field tomographic imaging

    by Mads Ry Vogel Jørgensen, Innokenty Kantor, Frederik Holm Gjørup, Daniel Riskov Sørensen, Thorbjørn Erik Køppen Christensen, Hari Narayanan Vasavan, Arash Panahifar, Silvia Forcat, Erik Bergbäck Knudsen, Marcelo J. P. Alcocer, et al.

    DanMAX is a hard X-ray materials science beamline at the ultra-low emittance 3 GeV storage ring at the MAX IV laboratory. It is designed for performing in situ and in operando studies using powder X-ray diffraction and full-field imaging. The beamline is equipped with an in-vacuum undulator source providing photons in the energy range 15–35 keV. The beam can be focused using compound refractive lenses, thus providing a variable beam size range from approximately 15 µm to 1.2 mm (FWHM) that can be changed in seconds. This paper presents the X-ray optics, discusses its performance, and shows the first endstation instrument for powder X-ray diffraction, available sample environments, and the surrounding infrastructure. The powder diffraction instrument is equipped with a CdTe hybrid pixel detector for powder X-ray diffraction and total scattering, as well as an energy-resolved silicon drift detector for X-ray fluorescence experiments. The instrument and infrastructure are designed to be highly flexible to accommodate various sample environments for in situ and in operando experiments.

  • Open Access

    Faster and targeted raster imaging through non-rectangular scanning

    by Frederik H. Gjørup, Thorbjørn E. K. Christensen, Yimeng Li, Marcelo J. P. Alcocer, Henrik Birkedal, Innokenty Kantor, Mads R. V. Jørgensen

    Many materials are spatially heterogenous and it is important to characterize this heterogeneity, which can be done by scanning microbeam X-ray diffraction (µXRD) or X-ray fluorescence (µXRF) microscopy. A modified approach to raster scanning is presented, where each line in a raster scan is of varying length, allowing for efficient scanning of non-rectangular areas. This shortens the measurement time significantly and similarly reduces the large amount of data generated from the area outside the sample that is normally produced for non-rectangular samples. The scanning procedure has been implemented for µ-X-ray diffraction and fluorescence mapping at the DanMAX diffraction beamline at MAX IV, Sweden. It was found that the reduction in required measurement time was nearly proportional to the reduction in scanned area, a significant reduction for non-rectangular samples. As an example, a section of the dactyl club of a stomatopod specimen ( Odontodactylus scyllarus ) was scanned.


  • Open Access

    Flow Through Fibre Networks - Effect of Fluid Rheology

    by Mats Stading, Camilla Öhgren, Sandra Barman, Torben Nilsson Pingel, Innokenty Kantor, Niklas Lorén

    Fluid flow in fibrous networks is crucial for many technical applications, such as wound care and hygiene products, as well as for tissue paper. The flow of Newtonian, low-viscous fluids like water is well studied, whereas the flow of viscoelastic fluids is less so. It is nevertheless highly important for the applications. Model fluids could be used to determine the influence of important rheological properties such as viscosity, elasticity, and shear thinning on the flow. Fluids containing the same components can be tuned to have constant viscosity (Newtonian), constant viscosity but elastic (Boger), and shear thinning to determine the influence of each property on the flow. Initially, flow was determined in real time for Newtonian and shear-thinning fluids using light microscopy and X-ray radiography. The results showed a large influence of the fluid rheology on the flow through the fibre networks.

  • Open Access

    Direct Detection of Hydrogen Reveals a New Macroscopic Crustal Water Reservoir on Early Mars

    by Estrid Buhl Naver, Katrine Wulff Nikolajsen, Martin Sæbye Carøe, Domenico Battaglia, Jens Frydenvang, Martin Bizzarro, Jakob Sauer Jørgensen, Kim Lefmann, Anders Kaestner, David Christian Mannes, et al.

    The next great leap in Martian exploration is the return of samples to Earth. Maximizing their scientific value requires non‐destructive analytical techniques for early three‐dimensional characterization. Neutron computed tomography (CT), highly sensitive to hydrogen, complements conventional X‐ray CT and enables the detection of hydrous phases. The distribution and nature of hydrous phases are central to understanding the habitability, climatic and geological evolution, and potential biosignatures of Mars. Using the only Martian crustal material available on Earth, the NWA 7034 meteorite and its pairs, we demonstrate that combined neutron, X‐ray, and X‐ray diffraction CT enables non‐destructive, sample‐wide hydrogen mapping, revealing the distribution and petrographic contexts of hydrous phases. We identify hydrogen‐rich iron oxyhydroxides within ancient igneous clasts, representing a macroscopic mineralogical water reservoir. These alteration assemblages closely resemble those observed by the Perseverance rover in Jezero crater, indicating that such hydrated phases may constitute a widespread near‐surface water reservoir on early Mars.

  • Open Access

    Distributed computing for the reconstruction of multi-terabyte tomographic X-ray imaging datasets

    by Thorbjørn Erik Køppen Christensen, Frederik Holm Gjørup, Mads Ry Vogel Jørgensen, Adrian Rodriguez-Palomo, Anders Bjorholm Dahl, Innokenty Kantor

    Tomographic datasets have continued to grow in size and volume along with camera technology and synchrotron brilliance. These larger datasets require new methods of distributing the reconstruction process on high-performance computing systems. Here we present a program for reconstructing large datasets, allowing the usage of either CPU- or GPU-powered clusters, and show the successful reconstruction of a 24000 pixel-wide dataset. This program is currently in use at the DanMAX beamline at the MAX IV synchrotron and is used as the default reconstruction method for all tomographic experiments at the beamline. Scans reconstructed with the presented pipeline have been published in multiple journals.


  • Open Access

    Sample environment for operando solid-state battery characterization

    by Therese S. S. Faurskov, Lasse N. Skov, Jakob B. Grinderslev, Lasse R. Kristensen, Jens Magnus Horsted Bendtsen, Mads Kofod Dahl, Tommy Kessler, Bettina Pilgaard Andersen, Innokenty Kantor, Mads R. V. Jørgensen, et al.

    All-solid-state batteries provide new hope for developing electrical energy storage far beyond the current state of the art. Here, we present a new sample environment developed for operando and in situ investigations of solid-state batteries, allowing for simultaneous collection of X-ray diffraction and electrochemical data along with temperature control and stack pressure monitoring. The Aarhus pressure temperature operando X-ray, APTOX, cell has a 35° 2θ opening, allowing for measurement of high-quality powder X-ray diffraction data to obtain valuable information on structural changes during battery cycling. We present two different variants of the APTOX cell: APTOX-Pmon with the ability to monitor the applied stack pressure for advanced applications and APTOX-Spring with a spring system to apply constant mechanical pressure. The APTOX cell is compatible with different X-ray window configurations, allowing for tailoring of the X-ray background and attenuation, as well as different physical properties depending on the optimal conditions for the system of interest. Finally, we demonstrate the applicability by presenting operando powder X-ray diffraction data obtained using both an in-house diffractometer equipped with an Ag K α 1 X-ray source and a synchrotron source at MAX IV, Lund, Sweden.


  • Open Access

    Micro and Nanostructural Diversity of Lizard Osteoderm Capping Tissue in Relation to Mechanical Performance

    by Adrian Rodriguez‐Palomo, Marius Didziokas, Malene Siri Berg Jacobsen, Thorbjørn Erik Køppen Christensen, Innokenty Kantor, Mads Ry Vogel Jørgensen, Klaus Pagh Almtoft, Jesper Skovhus Thomsen, Anthony Herrel, Catherine J.A. Williams, et al.

    Hard tissues in biology are typically hierarchical composites. Osteoderms are mineralized dermal structures, widespread in lizards, in which a hyper‐mineralized superficial layer, the capping tissue, has recently attracted attention for its unusual structural and mechanical features, with, e.g., moduli reaching those of enamel. Here, a comparative study of osteoderms from six lizard species whose osteoderms bear capping tissue ( Heloderma horridum , Pseudopus apodus , Broadleysaurus major , Corucia zebrata , Tiliqua scincoides , and Tiliqua rugosa ) are presented using X‐ray computed tomography, nanoindentation mapping, synchrotron X‐ray diffraction/fluorescence imaging, and finite element modeling. The capping tissue is consistently more mineralized than the underlying bone across all species. Mechanical testing shows that the capping tissue is stiffer and harder than bone, but its mechanical properties range widely, from values only slightly exceeding those of bone to enamel‐like levels. Two extreme architectures are observed: H. horridum and B. major exhibit unusually large, near‐isotropically arranged crystals and exceptional stiffness, while the other species display smaller crystals, are more textured than bone, and have less extreme stiffness. This demonstrates that capping tissue is a morphologically and functionally diverse specialization, highlighting its potential role in the evolutionary adaptation of osteoderms.


  • Open Access

    Electromechanical coupling in polaronic ceria

    by Victor Buratto Tinti, Milica Vasiljevic, Mathias Grønborg, Huaiyu Chen, Valdemar Frederiksen, Innokenty Kantor, Jesper Wallentin, Henrik Bruus, Vincenzo Esposito

    Oxygen-defective metal oxides like cerium oxides exhibit giant electrostriction and field-induced piezoelectricity due to a dynamic electrosteric interplay between oxygen defects, V O ⋅ ⋅ , and the fluorite lattice. While such mechanisms are generally attributed to oxygen vacancies, recent results also highlight that trapped cationic defects, Ce Ce ′ , i.e. small polarons, can contribute to the electromechanical properties of ceria. Here, we study nanocrystalline 5% Ca- and 10% Gd-doped ceria thin films with a high density of point defects and a constant oxygen vacancy concentration at 5% molar. We deposit thin films at low temperatures to promote microstructure disorder, i.e. nano-crystallinity, where the oxygen vacancies have low mobility due to high grain boundary interface densities. Still, the Ca2+ and Gd3+ dopants’ sizes and valence differences modulate trapping effects toward the defects in the lattice, giving an insight into the electromechanical nature of the defects in the material dominating the electrostriction. We find that electrosteric dopant-oxygen vacancy interactions only slightly affect the electromechanical properties, which mainly depend on the frequency and intensity of the applied electric field. On the other hand, n-type polaron, Ce Ce ′ , transport can emerge below the breakdown limit. These effects lead to an electromechanical coupling with a longitudinal electrostriction coefficient, M 33 , above 10−16 V2 m−2. Our results suggest that polaronic mechanisms substantially contribute to the electromechanical coupling in ceria. Also, the large ionic radius difference between Ce3+ and Ce4+ induces a large electro-strain upon polaron hopping, coupling electric stimuli to the observed electrostriction. This analysis provides new insights into the electromechanical effect of small polaronic semiconductive materials, opening new designing criteria for efficient electromechanical energy conversion.


  • Open Access

    Oxygen-defective electrostrictors for soft electromechanics

    by Victor Buratto Tinti, Jin Kyu Han, Valdemar Frederiksen, Huaiyu Chen, Jesper Wallentin, Innokenty Kantor, Anton Lyksborg-Andersen, Thomas Willum Hansen, Garam Bae, Wooseok Song, et al.

    Electromechanical metal oxides, such as piezoceramics, are often incompatible with soft polymers due to their crystallinity requirements, leading to high processing temperatures. This study explores the potential of ceria-based thin films as electromechanical actuators for flexible electronics. Oxygen-deficient fluorites, like cerium oxide, are centrosymmetric nonpiezoelectric crystalline metal oxides that demonstrate giant electrostriction. These films, deposited at low temperatures, integrate seamlessly with various soft substrates like polyimide and PET. Ceria thin films exhibit remarkable electrostriction ( M 33 > 10 −16 m 2 V −2 ) and inverse pseudo-piezo coefficients ( e 33 > 500 pmV −1 ), enabling large displacements in soft electromechanical systems. Our study explores resonant and off-resonant configurations in the low-frequency regime (<1 kHz), demonstrating versatility for three-dimensional and transparent electronics. This work advances the understanding of oxygen-defective metal oxide electromechanical properties and paves the way for developing versatile and efficient electromechanical systems for applications in biomedical devices, optical devices, and beyond.