Wataru Kamei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wataru Kamei has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Hajime Matsumine
From the Department of Plastic and Reconstructive Surgery, School of Medicine, Tokyo Women’s Medical University, Tokyo, Japan
2 shared publications Hiroyuki Sakurai
Department of Plastic and Reconstructive Surgery, School of Medicine, Tokyo Women's Medical University, Tokyo, Japan
2 shared publicationsMari Shimizu
Department of Plastic and Reconstructive Surgery, School of Medicine, Tokyo Women's Medical University, Tokyo, Japan
2 shared publications- Yosuke Niimi
Department of Plastic and Reconstructive Surgery, School of Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo, 162-8666, Japan
2 shared publications Atsuyoshi Osada
Department of Plastic and Reconstructive Surgery, School of Medicine, Tokyo Women's Medical University, Tokyo, Japan
1 shared publicationHironobu Osaki
Department of Physiology, Division of Neurophysiology, Tokyo Women's Medical University, Tokyo, Japan
1 shared publication
Latest Publications
- Open Access
- 18 October 2021
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 9 (10) , e3877
A Three-dimensionally Printed Acrylonitrile Butadiene Styrene Model for the Reduction of Nasomaxillary Fracture
Summary: The successful reduction of a nasomaxillary fracture was performed using a three-dimensional printed model. A 16-year-old boy was struck in the left orbit by a baseball; subsequently, he was diagnosed with the nasal bone fracture at a hospital, and was referred to the authors’ department. A left nasomaxillary fracture and nasal bone fracture were diagnosed by computed tomography. Standard triangulated language data for the mirror image of the frontal process of the right maxilla were obtained from digital imaging and communications in medicine data for preparing a three-dimensional printed acrylonitrile butadiene styrene model. On postinjury day 13, the frontal process fracture was reduced via transconjunctival and intraoral approaches. After the reduction of the fracture, an absorbable plate fitting to the shape of three-dimensional printed acrylonitrile butadiene styrene model was molded, and the maxillary frontal process and infraorbital rim were reduced and fixed with an absorbable plate and screws. Postoperative computed tomography demonstrated a favorable reduction. The intraoperative use of the 3D printed acrylonitrile butadiene styrene model was helpful in the nasomaxillary fracture reduction and fixation.
- 18 October 2021
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 9 (10) , e3877
Open AccessA Three-dimensionally Printed Acrylonitrile Butadiene Styrene Model for the Reduction of Nasomaxillary Fracture
Summary: The successful reduction of a nasomaxillary fracture was performed using a three-dimensional printed model. A 16-year-old boy was struck in the left orbit by a baseball; subsequently, he was diagnosed with the nasal bone fracture at a hospital, and was referred to the authors’ department. A left nasomaxillary fracture and nasal bone fracture were diagnosed by computed tomography. Standard triangulated language data for the mirror image of the frontal process of the right maxilla were obtained from digital imaging and communications in medicine data for preparing a three-dimensional printed acrylonitrile butadiene styrene model. On postinjury day 13, the frontal process fracture was reduced via transconjunctival and intraoral approaches. After the reduction of the fracture, an absorbable plate fitting to the shape of three-dimensional printed acrylonitrile butadiene styrene model was molded, and the maxillary frontal process and infraorbital rim were reduced and fixed with an absorbable plate and screws. Postoperative computed tomography demonstrated a favorable reduction. The intraoperative use of the 3D printed acrylonitrile butadiene styrene model was helpful in the nasomaxillary fracture reduction and fixation.
- 4 December 2018
- Published by Wiley in Microsurgery
- Vol. 39 (5) , 457-462
One‐stage reconstruction by dual‐innervated double muscle flap transplantation with the neural interconnection between the ipsilateral masseter and contralateral facial nerve for reanimating established facial paralysis: A report of 2 cases
The authors developed a one‐stage double‐muscle reconstruction technique for facial paralysis using a latissimus dorsi (LD) flap and a serratus anterior (SA) flap, which were dually reinnervated by the contralateral facial nerve (FN) and ipsilateral masseter nerve (MN). The procedure was performed for 61‐year‐old man 3‐years after resection of a malignant tumor and a 24‐year‐old woman 10‐years after temporal fracture with facial paralysis. A double‐muscle flap comprising left LD and SA flaps was harvested, a 15‐cm thoracodorsal nerve (TN) section was attached to the LD flap, and 5‐cm and 1‐cm sections of the long thoracic nerve (LTN) were attached to the proximal and distal sides of SA flap. The LD flap and SA flap were sutured along the direction of motion of the zygomaticus major and risorius muscles, respectively. The contralateral FN and ipsilateral MN were interconnected by nerve suturing: the medial branch of TN to the distal end of LTN, the proximal end of LTN to the ipsilateral MN, and the buccal branch of contralateral FN to the main trunk of TN. After surgery, good contraction of the transferred flaps resulted in reanimation of a natural symmetrical smile; no complications were observed during the 12‐month follow‐up period.
- 4 December 2018
- Published by Wiley in Microsurgery
- Vol. 39 (5) , 457-462
One‐stage reconstruction by dual‐innervated double muscle flap transplantation with the neural interconnection between the ipsilateral masseter and contralateral facial nerve for reanimating established facial paralysis: A report of 2 cases
The authors developed a one‐stage double‐muscle reconstruction technique for facial paralysis using a latissimus dorsi (LD) flap and a serratus anterior (SA) flap, which were dually reinnervated by the contralateral facial nerve (FN) and ipsilateral masseter nerve (MN). The procedure was performed for 61‐year‐old man 3‐years after resection of a malignant tumor and a 24‐year‐old woman 10‐years after temporal fracture with facial paralysis. A double‐muscle flap comprising left LD and SA flaps was harvested, a 15‐cm thoracodorsal nerve (TN) section was attached to the LD flap, and 5‐cm and 1‐cm sections of the long thoracic nerve (LTN) were attached to the proximal and distal sides of SA flap. The LD flap and SA flap were sutured along the direction of motion of the zygomaticus major and risorius muscles, respectively. The contralateral FN and ipsilateral MN were interconnected by nerve suturing: the medial branch of TN to the distal end of LTN, the proximal end of LTN to the ipsilateral MN, and the buccal branch of contralateral FN to the main trunk of TN. After surgery, good contraction of the transferred flaps resulted in reanimation of a natural symmetrical smile; no complications were observed during the 12‐month follow‐up period.
- 31 October 2018
- Published by Wiley in Microsurgery
- Vol. 38 (8) , 889-898
Axonal supercharged interpositional jump‐graft with a hybrid artificial nerve conduit containing adipose‐derived stem cells in facial nerve paresis rat model
Purpose: Interpositional jump‐graft (IPJG) technique with the hypoglossal nerve for supercharging can be applied in a facial nerve paresis case. In IPJG, an autologous nerve is required, and the donor site morbidity is unavoidable. Biodegradable nerve conduits are made from polyglycolic acid (PGA) and used recently without donor site complications after providing autologous grafts. Hybrid artificial nerve conduits with adipose‐derived stem cells (ASCs) also attract attention as a nerve‐regeneration enhancing agent. This study examined the effect of hybrid artificial nerve conduit on IPJG.Materials and methods: A total of 34 Lewis rats were used and divided into 4 groups by the bridge materials: autograft (n = 8), PGA nerve conduit (n = 8), hybrid PGA nerve conduit with ASCs (n = 8), and the nontreated control groups (n = 8). ASCs were collected from 2 rats and cultured. The animals were assessed physiologically and histopathologically at 13 weeks after surgery.Results: In compound muscle action potential, the amplitude of hybrid PGA group (3,222 ± 1,779 μV) was significantly higher than that of PGA group (1,961 ± 445 μV, P < .05), and no significant difference between hybrid PGA and autograft group. All treated groups showed a myelinated nerve regeneration with double innervation in hypoglossal and facial nerve nuclei for vibrissal muscle.Conclusion: This study showed the effectiveness of IPJG with a hybrid PGA conduit especially in physiological examination.
- 31 October 2018
- Published by Wiley in Microsurgery
- Vol. 38 (8) , 889-898
Axonal supercharged interpositional jump‐graft with a hybrid artificial nerve conduit containing adipose‐derived stem cells in facial nerve paresis rat model
Purpose: Interpositional jump‐graft (IPJG) technique with the hypoglossal nerve for supercharging can be applied in a facial nerve paresis case. In IPJG, an autologous nerve is required, and the donor site morbidity is unavoidable. Biodegradable nerve conduits are made from polyglycolic acid (PGA) and used recently without donor site complications after providing autologous grafts. Hybrid artificial nerve conduits with adipose‐derived stem cells (ASCs) also attract attention as a nerve‐regeneration enhancing agent. This study examined the effect of hybrid artificial nerve conduit on IPJG.Materials and methods: A total of 34 Lewis rats were used and divided into 4 groups by the bridge materials: autograft (n = 8), PGA nerve conduit (n = 8), hybrid PGA nerve conduit with ASCs (n = 8), and the nontreated control groups (n = 8). ASCs were collected from 2 rats and cultured. The animals were assessed physiologically and histopathologically at 13 weeks after surgery.Results: In compound muscle action potential, the amplitude of hybrid PGA group (3,222 ± 1,779 μV) was significantly higher than that of PGA group (1,961 ± 445 μV, P < .05), and no significant difference between hybrid PGA and autograft group. All treated groups showed a myelinated nerve regeneration with double innervation in hypoglossal and facial nerve nuclei for vibrissal muscle.Conclusion: This study showed the effectiveness of IPJG with a hybrid PGA conduit especially in physiological examination.