Saba Rafieian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Saba Rafieian has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Azin Mirzajavadkhan
Faculty of Engineering, Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
2 shared publications - Muhammad Hasibul Hasan
Toronto Metropolitan University
2 shared publications - Stephen D. Waldman
Department of Chemical Engineering, Toronto Metropolitan University, Toronto, Canada
2 shared publications - Cari Marisa Whyne
Faculty of Engineering, Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
1 shared publication Chahat Soi
Ryerson University, Toronto, Canada
1 shared publication- Jeffrey A. Fialkov
Division of Plastic Surgery, Department of Surgery, Sunnybrook Health Sciences Centre, University of Toronto, ON, Canada
1 shared publication
Latest Publications
- Open Access
- 9 March 2026
- Published by SAGE Publications in CARTILAGE
- Vol. 17 (4) , 928-938
Protective Effects of Spirulina Supplementation on Chondrocytes Under Moderate Acute Dynamic Compression
Objective: To determine the influence of Spirulina supplementation on the response of bovine chondrocytes to mechanical compression with respect to extracellular matrix dynamics (proteoglycan and collagen) and inflammation [nitric oxide (NO)]. Methods: Bovine chondrocytes were embedded in agarose constructs and cultured for 14 days in basal media or media supplemented with Spirulina (30 or 90 µg/mL). Constructs were exposed to 10% dynamic compression. DNA content, NO levels, proteoglycan content and release, and collagen synthesis were measured to assess extracellular matrix (ECM) responses. Results: DNA content did not differ among groups. Spirulina supplementation increased NO levels in constructs and media, with the highest effect observed at 90 µg/mL. Proteoglycan content decreased in Spirulina-treated constructs and declined further after compression, while proteoglycan release increased across all groups. Collagen synthesis and content were elevated by Spirulina, particularly at 90 µg/mL, and further increased following dynamic compression. Conclusions: Spirulina supplementation, particularly at higher concentrations, enhances ECM turnover and increases NO production in chondrocytes under mechanical loading, indicating potential modulation of matrix dynamics that may be beneficial. However, these results are derived from an in vitro model and may not fully represent in vivo physiological conditions.
- 9 March 2026
- Published by SAGE Publications in CARTILAGE
- Vol. 17 (4) , 928-938
Open AccessProtective Effects of Spirulina Supplementation on Chondrocytes Under Moderate Acute Dynamic Compression
Objective: To determine the influence of Spirulina supplementation on the response of bovine chondrocytes to mechanical compression with respect to extracellular matrix dynamics (proteoglycan and collagen) and inflammation [nitric oxide (NO)]. Methods: Bovine chondrocytes were embedded in agarose constructs and cultured for 14 days in basal media or media supplemented with Spirulina (30 or 90 µg/mL). Constructs were exposed to 10% dynamic compression. DNA content, NO levels, proteoglycan content and release, and collagen synthesis were measured to assess extracellular matrix (ECM) responses. Results: DNA content did not differ among groups. Spirulina supplementation increased NO levels in constructs and media, with the highest effect observed at 90 µg/mL. Proteoglycan content decreased in Spirulina-treated constructs and declined further after compression, while proteoglycan release increased across all groups. Collagen synthesis and content were elevated by Spirulina, particularly at 90 µg/mL, and further increased following dynamic compression. Conclusions: Spirulina supplementation, particularly at higher concentrations, enhances ECM turnover and increases NO production in chondrocytes under mechanical loading, indicating potential modulation of matrix dynamics that may be beneficial. However, these results are derived from an in vitro model and may not fully represent in vivo physiological conditions.
- 24 November 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (2) , 381-392
Tissue-Engineered Cartilage for Nasal Reconstruction: Mechanical Stimulation Through Bidirectional Bending
Purpose In nasal reconstruction, cartilage struts are used to create the structural foundation of the nose. These struts, carved from autologous or allogeneic grafts of costal cartilage, are often limited by availability, warping, or resorption. This study aimed to investigate the mechanical and biochemical outcomes of applying dynamic bidirectional bending to tissue-engineered constructs, hypothesizing that such stimulation would improve matrix synthesis and mechanical properties. Methods Chondrocyte-seeded agarose struts were subjected to two weeks of dynamic bidirectional four-point bending at peak-to-peak strain amplitudes of 0, 2.5, 5, and 7.5%, for 1200 cycles at 1 Hz starting after a two-week pre-culture. Constructs were analyzed for DNA, proteoglycan, and collagen content, and evaluated via histology, polarized light microscopy, and four-point bending tests. Outcomes were compared to unstimulated controls, unidirectionally stimulated constructs, and native septal cartilage. Results Bidirectional bending at a 2.5% strain amplitude increased collagen content by 74% and bending modulus by 72% relative to controls. Under 5% strain amplitudes, proteoglycan accumulation peaked with a 51% increase. Constructs stimulated unidirectionally showed reduced matrix deposition. Histological analysis demonstrated enhanced ECM deposition with region-specific proteoglycan and collagen distribution, partially resembling zonal patterns in native cartilage, although engineered constructs remained mechanically inferior to native septal cartilage. Conclusion Dynamic bidirectional bending enhances the biochemical and mechanical properties of tissue-engineered constructs. Lower strain amplitudes were most effective, supporting its consideration in developing mechanically robust grafts for nasal reconstruction. Further optimization of loading protocols and culture duration is needed to bridge the gap with native tissue performance.
- 24 November 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (2) , 381-392
Tissue-Engineered Cartilage for Nasal Reconstruction: Mechanical Stimulation Through Bidirectional Bending
Purpose In nasal reconstruction, cartilage struts are used to create the structural foundation of the nose. These struts, carved from autologous or allogeneic grafts of costal cartilage, are often limited by availability, warping, or resorption. This study aimed to investigate the mechanical and biochemical outcomes of applying dynamic bidirectional bending to tissue-engineered constructs, hypothesizing that such stimulation would improve matrix synthesis and mechanical properties. Methods Chondrocyte-seeded agarose struts were subjected to two weeks of dynamic bidirectional four-point bending at peak-to-peak strain amplitudes of 0, 2.5, 5, and 7.5%, for 1200 cycles at 1 Hz starting after a two-week pre-culture. Constructs were analyzed for DNA, proteoglycan, and collagen content, and evaluated via histology, polarized light microscopy, and four-point bending tests. Outcomes were compared to unstimulated controls, unidirectionally stimulated constructs, and native septal cartilage. Results Bidirectional bending at a 2.5% strain amplitude increased collagen content by 74% and bending modulus by 72% relative to controls. Under 5% strain amplitudes, proteoglycan accumulation peaked with a 51% increase. Constructs stimulated unidirectionally showed reduced matrix deposition. Histological analysis demonstrated enhanced ECM deposition with region-specific proteoglycan and collagen distribution, partially resembling zonal patterns in native cartilage, although engineered constructs remained mechanically inferior to native septal cartilage. Conclusion Dynamic bidirectional bending enhances the biochemical and mechanical properties of tissue-engineered constructs. Lower strain amplitudes were most effective, supporting its consideration in developing mechanically robust grafts for nasal reconstruction. Further optimization of loading protocols and culture duration is needed to bridge the gap with native tissue performance.
- Open Access
- 26 March 2020
- Published by Deer Hill Publications in International Journal of Engineering Materials and Manufacture
- Vol. 5 (1) , 2-11
Toxicity of Metal Implants and Their Interactions with Stem Cells: A Review
The development of biomaterials has increased rapidly in order to alter the fate of stem cells and use them in therapeutic applications. Currently, many biomaterials are used in the biomedical industry. Biomaterials act as a “nitch” which is an environment regulating the development and self-renewal behaviour of stem cells. The stem cells receive signals from the “nitch” and proceeds accordingly. In order to control the behaviour of stem cells, the chemical and physical properties of the biomaterial should be taken into consideration. This review paper focuses on the different type of metals used in biomaterials, identifying their current issues and challenges including fatigue, corrosion resistance, and the toxicity caused by metal ions released in the body. It also provides detailed explanations about the impact of various metal implants such as stainless steel, cobalt-chromium, and titanium on stem cells and the toxicity caused by the interaction of biomaterials and various trace elements with the hostile body environment.
- 26 March 2020
- Published by Deer Hill Publications in International Journal of Engineering Materials and Manufacture
- Vol. 5 (1) , 2-11
Open AccessToxicity of Metal Implants and Their Interactions with Stem Cells: A Review
The development of biomaterials has increased rapidly in order to alter the fate of stem cells and use them in therapeutic applications. Currently, many biomaterials are used in the biomedical industry. Biomaterials act as a “nitch” which is an environment regulating the development and self-renewal behaviour of stem cells. The stem cells receive signals from the “nitch” and proceeds accordingly. In order to control the behaviour of stem cells, the chemical and physical properties of the biomaterial should be taken into consideration. This review paper focuses on the different type of metals used in biomaterials, identifying their current issues and challenges including fatigue, corrosion resistance, and the toxicity caused by metal ions released in the body. It also provides detailed explanations about the impact of various metal implants such as stainless steel, cobalt-chromium, and titanium on stem cells and the toxicity caused by the interaction of biomaterials and various trace elements with the hostile body environment.
- Open Access
- 1 December 2018
- Published by Deer Hill Publications in International Journal of Engineering Materials and Manufacture
- Vol. 3 (4) , 224-236
Experimental Study and Computer Simulation of Fracture Toughness of Ni Base Superalloy using CT Specimen
Due to superior mechanical and metallurgical performance, Nickel-base Alloys 617 and 276 have been considered as structural material for used in complex and stochastic applications. Surface irregularities such as cracks in the material may be vulnerable to the structural integrity of an engineering component. Void growth behavior is however analyzed using crystal plasticity theory in nickel-based super alloys. Elastic-plastic fracture mechanics base single compact tension specimen has been used to determine the J1C value as a function of temperature of austenitic Alloy 617 and 276 for ductile crack growth behavior. Crack formation is appropriately explained through crack nucleation based on the microstructural heterogeneity properties of the alloys. Alloy 617 showed a fair increased resistance to fracture as temperature increased from ambient to 5000C for duplicate testing, satisfying the EPFM criteria. Whereas the J1C values of Alloy 276 increased gradually with temperature up to 300° C and due to enhanced plasticity in the vicinity of 4000 C this alloy shows inconsistent value. Two-dimensional simulation of J-integral model of these nickel base super alloys at temperature range 1000C to 5000 C has been proposed. Particular focus is given on the load line displacement where crack propagation occurs during the loading phase only. Path independency of J-integral has been clearly demonstrated for both the alloys up to 3000 C employing finite element analysis meshing with 1922 quadrilateral 2D solid elements in ANSYS. Cracks are typically initiated in relation to the level of strain range. A higher strain range initiates cracks due to precipitate shearing, whereas a low strain range initiates cracks with oxidation reactions and carbide diffusion. The values of K1C and crack tip opening displacement for these alloys have been calculated based on the experimental data. Moreover, fracture morphology in the loading and unloading sequences near the crack tip has been analyzed by SEM.
- 1 December 2018
- Published by Deer Hill Publications in International Journal of Engineering Materials and Manufacture
- Vol. 3 (4) , 224-236
Open AccessExperimental Study and Computer Simulation of Fracture Toughness of Ni Base Superalloy using CT Specimen
Due to superior mechanical and metallurgical performance, Nickel-base Alloys 617 and 276 have been considered as structural material for used in complex and stochastic applications. Surface irregularities such as cracks in the material may be vulnerable to the structural integrity of an engineering component. Void growth behavior is however analyzed using crystal plasticity theory in nickel-based super alloys. Elastic-plastic fracture mechanics base single compact tension specimen has been used to determine the J1C value as a function of temperature of austenitic Alloy 617 and 276 for ductile crack growth behavior. Crack formation is appropriately explained through crack nucleation based on the microstructural heterogeneity properties of the alloys. Alloy 617 showed a fair increased resistance to fracture as temperature increased from ambient to 5000C for duplicate testing, satisfying the EPFM criteria. Whereas the J1C values of Alloy 276 increased gradually with temperature up to 300° C and due to enhanced plasticity in the vicinity of 4000 C this alloy shows inconsistent value. Two-dimensional simulation of J-integral model of these nickel base super alloys at temperature range 1000C to 5000 C has been proposed. Particular focus is given on the load line displacement where crack propagation occurs during the loading phase only. Path independency of J-integral has been clearly demonstrated for both the alloys up to 3000 C employing finite element analysis meshing with 1922 quadrilateral 2D solid elements in ANSYS. Cracks are typically initiated in relation to the level of strain range. A higher strain range initiates cracks due to precipitate shearing, whereas a low strain range initiates cracks with oxidation reactions and carbide diffusion. The values of K1C and crack tip opening displacement for these alloys have been calculated based on the experimental data. Moreover, fracture morphology in the loading and unloading sequences near the crack tip has been analyzed by SEM.