Rekha Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Rekha Singh has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- James A. Smith
Department of Civil and Environmental Engineering, University of Virginia, Charlottesville, VA 22904, USA
3 shared publications - Alexandra Lorentz
Division of Consolidated Laboratory Services, Department of General Services, Richmond, 23219, United States
1 shared publication Andrew Warren
Biocomplexity Institute and Initiative, University of Virginia, Charlottesville, 22904, United States
1 shared publication- Aniruddha Adiga
University of Virginia
1 shared publication - Baltazar Espinoza
Affiliation Biocomplexity Institute, University of Virginia, Virginia, United States of America
1 shared publication - Bryan Lewis
University of Virginia, Charlottesville, VA, USA
1 shared publication
Latest Publications
- 11 March 2021
- Published by Springer Nature in Bulletin of Environmental Contamination and Toxicology
- Vol. 108 (3) , 518-525
Modified Oyster Waste Shells as a Value-Added Sorbent for Lead Removal from Water
Used oyster shells are considered a waste product of the seafood industry. Herein, we hypothesize that oyster shells can be used as a raw ingredient to synthesize effective sorbents. This study investigated the lead sorption ability of modified oyster shells [phosphoric-acid treated oyster shell (POS) and oyster shells with phosphoric acid (OS + P)] from water. XRD confirmed the presence of calcium phosphate. Lead removal efficiency as a function of sorbent type was as follows: OS + P > POS > OS. Sorption was quantified effectively using Freundlich isotherms with correlation coefficients ranging from 0.98 to 0.99. The Freundlich parameter values of Kf and n indicate that POS and OS + P exhibit stronger lead sorption than OS. These results indicate that modified oyster shells with OS + P and POS could be effective sorbents for lead removal from water. Kinetic models were well described by a pseudo-second-order rate constant for all the sorbents.
- 11 March 2021
- Published by Springer Nature in Bulletin of Environmental Contamination and Toxicology
- Vol. 108 (3) , 518-525
Modified Oyster Waste Shells as a Value-Added Sorbent for Lead Removal from Water
Used oyster shells are considered a waste product of the seafood industry. Herein, we hypothesize that oyster shells can be used as a raw ingredient to synthesize effective sorbents. This study investigated the lead sorption ability of modified oyster shells [phosphoric-acid treated oyster shell (POS) and oyster shells with phosphoric acid (OS + P)] from water. XRD confirmed the presence of calcium phosphate. Lead removal efficiency as a function of sorbent type was as follows: OS + P > POS > OS. Sorption was quantified effectively using Freundlich isotherms with correlation coefficients ranging from 0.98 to 0.99. The Freundlich parameter values of Kf and n indicate that POS and OS + P exhibit stronger lead sorption than OS. These results indicate that modified oyster shells with OS + P and POS could be effective sorbents for lead removal from water. Kinetic models were well described by a pseudo-second-order rate constant for all the sorbents.
- Open Access
Effect of Chloride Ions on the Point-of-Use Drinking Water Disinfection Performance of Porous Ceramic Media Embedded with Metallic Silver and Copper
This study quantifies the effects of chloride ions on silver and copper release from porous ceramic cubes embedded with silver and copper and its effect on E. coli disinfection in drinking water. Log-reduction of E. coli by silver ions decreased after 4 h of contact time as the chloride ion concentration increased from 0 to 250 mg/L but, it was not changed by copper ions under the same conditions. For silver addition by silver-ceramic cubes, log reductions of E. coli decreased sharply from 7.2 to 1.6 after 12 h as the chloride concentration increased from 0 to 250 mg/L. For the silver-ceramic cube experiments, chloride ion also reduced the total silver concentration in solution. After 24 h, total silver concentrations in solution decreased from 61 µg/L to 20 µg/L for corresponding chloride ion concentrations. According to the MINTEQ equilibrium model analysis, the decrease in disinfection ability with silver embedded ceramic cubes could be the result of precipitation of silver ions as silver chloride. This suggests that AgCl was precipitating within the pore space of the ceramic. These results indicate that, although ionic silver is a highly effective disinfectant for E. coli, the presence of chloride ions can significantly reduce disinfection efficacy. For copper-ceramic cubes, log reductions of E. coli by copper embedded cubes increased from 1.2 to 1.5 when chloride ion concentration increased from 0 to 250 mg/L. Total copper concentrations in solution increased from 4 µg/L to 14 µg/L for corresponding chloride ion concentrations. These results point towards the synergistic effect of chloride ions on copper oxidation as an increased concentration of chloride enhances copper release.
Open AccessEffect of Chloride Ions on the Point-of-Use Drinking Water Disinfection Performance of Porous Ceramic Media Embedded with Metallic Silver and Copper
This study quantifies the effects of chloride ions on silver and copper release from porous ceramic cubes embedded with silver and copper and its effect on E. coli disinfection in drinking water. Log-reduction of E. coli by silver ions decreased after 4 h of contact time as the chloride ion concentration increased from 0 to 250 mg/L but, it was not changed by copper ions under the same conditions. For silver addition by silver-ceramic cubes, log reductions of E. coli decreased sharply from 7.2 to 1.6 after 12 h as the chloride concentration increased from 0 to 250 mg/L. For the silver-ceramic cube experiments, chloride ion also reduced the total silver concentration in solution. After 24 h, total silver concentrations in solution decreased from 61 µg/L to 20 µg/L for corresponding chloride ion concentrations. According to the MINTEQ equilibrium model analysis, the decrease in disinfection ability with silver embedded ceramic cubes could be the result of precipitation of silver ions as silver chloride. This suggests that AgCl was precipitating within the pore space of the ceramic. These results indicate that, although ionic silver is a highly effective disinfectant for E. coli, the presence of chloride ions can significantly reduce disinfection efficacy. For copper-ceramic cubes, log reductions of E. coli by copper embedded cubes increased from 1.2 to 1.5 when chloride ion concentration increased from 0 to 250 mg/L. Total copper concentrations in solution increased from 4 µg/L to 14 µg/L for corresponding chloride ion concentrations. These results point towards the synergistic effect of chloride ions on copper oxidation as an increased concentration of chloride enhances copper release.
- Open Access
Optimization of Silver Ion Release from Silver-Ceramic Porous Media for Household Level Water Purification
A novel method has been developed to produce zerovalent silver nanopatches in a porous ceramic tablet using only clay, sawdust, water, and silver nitrate as precursors. When placed in 10 L of water, the silver nanopatches (2 to 3 nm diameter per patch) are gradually oxidized to produce silver ions, which diffuse out of the tablet into the bulk solution. The objective of this work is to optimize the silver-ceramic design to increase the rate of silver ion release from the tablet to further improve disinfection kinetics. To meet this objective, ceramic tablets were fabricated in different ways and tested for silver ion release into water over 8 to 24 h periods. Silver addition had an approximately linear effect on silver ion. Grinding the tablet into different particle sizes (4–60 mesh) had the most significant effect on silver release. However, if this ground fraction is compartmentalized into a fabric bag, silver levels produced in the water drop back to levels comparable to the single tablet form. Based on these results, 1 and 2 cm ceramic cubes were manufactured and represented a reasonable compromise between silver release and usability. Disinfection experiments on these silver-ceramic cubes resulted in effective disinfection of E. coli in laboratory experiments.
Open AccessOptimization of Silver Ion Release from Silver-Ceramic Porous Media for Household Level Water Purification
A novel method has been developed to produce zerovalent silver nanopatches in a porous ceramic tablet using only clay, sawdust, water, and silver nitrate as precursors. When placed in 10 L of water, the silver nanopatches (2 to 3 nm diameter per patch) are gradually oxidized to produce silver ions, which diffuse out of the tablet into the bulk solution. The objective of this work is to optimize the silver-ceramic design to increase the rate of silver ion release from the tablet to further improve disinfection kinetics. To meet this objective, ceramic tablets were fabricated in different ways and tested for silver ion release into water over 8 to 24 h periods. Silver addition had an approximately linear effect on silver ion. Grinding the tablet into different particle sizes (4–60 mesh) had the most significant effect on silver release. However, if this ground fraction is compartmentalized into a fabric bag, silver levels produced in the water drop back to levels comparable to the single tablet form. Based on these results, 1 and 2 cm ceramic cubes were manufactured and represented a reasonable compromise between silver release and usability. Disinfection experiments on these silver-ceramic cubes resulted in effective disinfection of E. coli in laboratory experiments.
- 1 February 2019
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 145 (2)
E. coli Inactivation by Metals and Effects of Changes in Water Chemistry
Microbiologically unsafe drinking water remains a leading cause of child morbidity and mortality in the world despite high investment in water-treatment infrastructure. This study explores the antimicrobial potential of Ag, Cu, Zn, Ni, and Co, at concentrations below the World Health Organization drinking standards, to inactivate a nonpathogenic strain of E. coli in synthetic groundwater (SGW). Disinfection capabilities of Ag and Cu are also tested against bacteria in natural surface water (NSW) to test the effect of a natural and more-complex water chemistry. The influence of changes in pH, , , , and concentrations on bacterial inactivation in SGW are also studied. The MINTEQ equilibrium model is used to study the speciation of the metals in solution. The Chick–Watson model is employed for kinetic modelling of the data. The results show that greater than 99.99% bacterial inactivation occurs within 12 h of contact time by Ag and Cu. Concentration and time played a major role in the disinfection process. Co and Ni are ineffective disinfectants. Higher inactivation of E. coli by Ag and Cu is recorded in SGW than in NSW. The inactivation efficiencies of the metals studied follow the trend .- 1 February 2019
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 145 (2)
E. coli Inactivation by Metals and Effects of Changes in Water Chemistry
Microbiologically unsafe drinking water remains a leading cause of child morbidity and mortality in the world despite high investment in water-treatment infrastructure. This study explores the antimicrobial potential of Ag, Cu, Zn, Ni, and Co, at concentrations below the World Health Organization drinking standards, to inactivate a nonpathogenic strain of E. coli in synthetic groundwater (SGW). Disinfection capabilities of Ag and Cu are also tested against bacteria in natural surface water (NSW) to test the effect of a natural and more-complex water chemistry. The influence of changes in pH, , , , and concentrations on bacterial inactivation in SGW are also studied. The MINTEQ equilibrium model is used to study the speciation of the metals in solution. The Chick–Watson model is employed for kinetic modelling of the data. The results show that greater than 99.99% bacterial inactivation occurs within 12 h of contact time by Ag and Cu. Concentration and time played a major role in the disinfection process. Co and Ni are ineffective disinfectants. Higher inactivation of E. coli by Ag and Cu is recorded in SGW than in NSW. The inactivation efficiencies of the metals studied follow the trend .