MFMariana Fratu

Mariana Fratu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mariana Fratu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Carbon Footprint Evaluation and Reduction Strategies for a Residential Building in Romania: A Case Study

    by Alexandru Mihai Bulmez, George Dragomir, Sorin Ionuț Bolocan, Alin Ionuț Brezeanu, Mariana Fratu, Nicolae Fani Iordan, Norbert Gocz, Răzvan Calotă

    Single-family residential buildings represent the highest share of building sector in Romania. Their operation emits the most CO2 into Earth’s atmosphere, as most of them are not energy efficient. A life cycle assessment is performed for a case study building, built in 2019 in Romania, establishing its carbon footprint. For this building CO2 emissions are 177.55 tCO2 for the construction stage, 76.19 tCO2 for the operation stage, 3.55 tCO2 for the demolition stage, and a total of 129.76 tCO2 after reducing with the carbon sequestration from vegetation 127.53 tCO2. The main purpose of this study is to analyse the carbon footprint for a typical single-family Romanian household, with an emphasis on the operational stage. The study compares the results and extrapolates them to all single-family residential buildings in Romania regarding CO2 emissions, with an emphasis on the operational stage. The results illustrate a considerable reduction in CO2 emissions from old, high energy consumption buildings to new, low energy consumption buildings. The highest operational stage emissions for old buildings in Romania are 962.94 tCO2 for firewood heating and 573.69 tCO2 for gas boiler heating, as those buildings are not insulated and don’t use a heat pump. Additionally, considering the use of photovoltaic panels for the entire lifespan, the CO2 emissions for the operational stage decrease for the case study building from 76.18 tCO2 to 19.90 tCO2. Moreover, using a heat pump detriments firewood or gas boilers, decreasing CO2 emissions for the operational stage by up to 34% and 26%, respectively. Due to the higher cost of electrical energy compared to natural gas in Romania, gas boilers are more cost-effective than heat pumps. Because of this, and the higher implementation costs, the tendency is towards natural gas. This will in turn result in an increase of CO2 emission for the entire life cycle of the building by approximate 32% for new buildings and 86% for old, high-energy-consumption buildings.


  • Open Access

    Carbon Footprint Evaluation and Reduction Strategies for a Residential Building in Romania: A Case Study

    by Alexandru Mihai Bulmez, George Dragomir, Sorin Ionuț Bolocan, Alin Ionuț Brezeanu, Mariana Fratu, Nicolae Fani Iordan, Norbert Gocz, Răzvan Calotă

    Single-family residential buildings represent the highest share of building sector in Romania. Their operation emits the most CO2 into Earth’s atmosphere, as most of them are not energy efficient. A life cycle assessment is performed for a case study building, built in 2019 in Romania, establishing its carbon footprint. The study compares the results and extrapolate them to all single-family residential buildings in Romania, regarding CO2 emissions with an emphasis on the operational stage. The results illustrate a considerable reduction in CO2 emissions from old, high energy consumption buildings to new, low energy consumption buildings. Moreover, using a heat pump in the detriment of firewood or gas boilers decreases the CO2 emissions for the operational stage up to 34% and 26% respectively. Due to the higher cost of electrical energy compared to natural gas in Romania, gas boilers are more cost-effective than heat pumps. Because of this, and the higher implementation costs, the tendency is towards natural gas. This in turn will result in an increase of CO2 emission for the entire life cycle of the building by approximate 32% for new buildings and 86% for old, high energy consumption buildings.


  • Open Access

    CFD Analysis for a New Trombe Wall Concept

    by Alexandru Mihai Bulmez, Alin Ionuț Brezeanu, George Dragomir, Mariana Fratu, Nicolae Fani Iordan, Sorin Ionuț Bolocan, Lucian Rozorea, Eugen Călin Popa, Gabriel Năstase

    The envelope (façade) of a building is the first barrier between the exterior and the interior of the building and withstands the highest variation in temperature and solar radiation. Trombe walls are used to take advantage of that and contribute to the heating of interior air, helping the heating system. In this study, a new Trombe wall design is presented to contribute significantly to the indoor ventilation of residential buildings. For this, an exterior wall equipped with a proposed Trombe system was studied in a numerical simulation analysis. The proposed systems consist of two important sections, an exterior one and an interior one. The air cavities on the exterior of the wall, covered with silica glass, are the first heat-transfer layer. The secondary layer used for heat transfer, on the interior, is comprised of a MPCLB wall of 115 mm. The air circulation from the exterior to the interior was established as forced convection with a ventilator. The air circulates through the first heating layer on the exterior air cavities and then passes through the second heating layer on the interior MPCLBs. Two cities in Romania were considered to represent the coldest and hottest climates in Romania. Brașov represents the cold climate and Constanța represents the hot climate. In the investigation, both the presence and absence of solar radiation were taken into account. In total, four cases were established. For all four cases, monthly research was made using monthly mean temperatures, and direct and diffuse solar radiation. The results are promising and illustrate that the system works best during the transitional seasons of spring and autumn. The lower the outdoor temperature, the higher the temperature can be increased. Overall, solar radiation accounted for an average 2 °C increase. The temperature increase varied between 3.4 °C and 15.99 °C for Brașov and between 6.42 °C and 12.07 °C in Constanța. This study presents an alternative way to use the Trombe wall for indoor ventilation purposes throughout the year, compared to traditional uses for the Trombe wall for indoor heating.


  • Open Access

    CFD Analysis for a New Trombe Wall Concept

    by Alexandru Mihai Bulmez, Alin Ionuț Brezeanu, George Dragomir, Mariana Fratu, Nicolae Fani Iordan, Sorin Ionuț Bolocan, Lucian Rozorea, Eugen Călin Popa, Gabriel Năstase

    The envelope (façade) of a building is the first barrier between the exterior and the interior of the building and withstands the highest variation of temperature and solar radiation. Trombe walls are used to take advantage of that and contribute to the heating of interior air, helping the heating system. In this study, a new Trombe wall design is presented with the aim to contribute significantly to the ventilation of residential buildings. For this an exterior wall equipped with a proposed Trombe system was studied in a numerical simulation analysis. The proposed systems consist of two parts, the air cavities on the exterior of the wall, covered with silica glass, and another layer used for heat transfer, on the interior, comprised of a MPCLBs wall of 115mm. Two cities in Romania were considered to represent the coldest and hottest climate in Romania. Brașov representing the cold climate and Constanța representing the hot climate. In the investigation, both the presence and absence of solar radiation were taken into account. In total 4 cases were established. For all four cases monthly research was made using monthly means temperature, direct and diffuse solar radiation. The results are promising and illustrate that the system works the best during the transitional seasons of spring and autumn. The lower the outdoor temperature the higher the temperature can be increased. Overall, solar radiation accounted for an average of 2 °C increase. The temperature increase varied between 3.4 °C to 15.99 °C for Brașov and between 6.42 °C to 12.07 °C in Constanța.


  • Open Access

    Numerical Investigation on Auxiliary Heat Sources for Horizontal Ground Heat Exchangers

    by Alexandru-Mihai Bulmez, Vasile Ciofoaia, Gabriel Năstase, George Dragomir, Alin-Ionuț Brezeanu, Nicolae-Fani Iordan, Sorin-Ionuț Bolocan, Mariana Fratu, Costel Pleșcan, Christiana Emilia Cazacu, et al.

    Human interference with the Earth’s climate cannot be ignored any longer. Renewable energy sources need utmost attention in all energy sectors. For buildings, geothermal energy for heating, cooling, and domestic hot water is a sustainable solution. Horizontal ground heat exchangers (HGHE) demonstrate promising results with low installation costs. Research is focused on increasing their thermal performances by structural improvements and ground thermal proprieties improvements, with little research on using auxiliary heat to increase their performances. A numerical model for an HGHE was established to investigate the effects of auxiliary heat sources on the performances of the HGHE. The results demonstrate that heat transfer into the HGHE increases the overall ground temperature at the end of the heating season by 138.50% compared with no heat transfer from auxiliary heat sources. The ground freezing period decreased by approximately 24.74% by having a heated basement, approximately 40.20% by transferring heat with solar thermal panels, and approximately 62.88% by using both auxiliary heat sources. The difference between the undisturbed ground temperature and the ground temperature with no auxiliary heat sources at the end of the season was 3.45 °C. The difference between the undisturbed ground temperature and the ground temperature with all auxiliary heat sources resulted in 0.92 °C.