Sudarsono Sudarsono
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Sudarsono Sudarsono has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Toto Rusianto
Department of Mechanical Engineering, The Graduate School of Universitas AKPRIND, Indonesia
3 shared publicationsPurnawan
Department of Environmental Engineering, Institut Sains & Teknologi AKPRIND Yogyakarta 55222 Indonesia
2 shared publicationsAnak Agung Putu Susastriawan
Department of Mechanical Engineering, Faculty of Industrial Technology, Institut Sains & Teknologi AKPRIND, Yogyakarta, Indonesia
1 shared publication- Anak Agung Putu Susastriawan
Department of Mechanical Engineering, Faculty of Industrial Technology, Institut Sains & Teknologi AKPRIND, Indonesia
1 shared publication Andang Novianta Muhammad
Department of Electrical Engineering, Institut Sains & Teknologi AKPRIND Yogyakarta 55222 Indonesia
1 shared publicationCyrilla Indri Parwati
Department of Industrial Engineering, Institut Sains & Teknologi AKPRIND Yogyakarta - Indonesia
1 shared publication
Latest Publications
- Open Access
- 25 August 2025
- Published by Everant Journals in Engineering and Technology Journal
- Vol. 10 (08) , 6409-6411
Sanding Machine Powered By 2 X 150 WP Solar Panels
The depletion of fossil fuel leads in searching renewable energy source. Solar energy, one of many renewable energy sources, is very suitable to be used in Indonesia. Indonesia has about 200 GW solar energy potential. This solar energy has been converted into electrical energy through solar power plant. However, only limited of those solar power plants powers household appliances. Thus, the present work aims to developed 2 x 150 WP solar power plant for sanding machine. The performance of the panel is evaluated in in terms of output voltage, current, power, and conversion efficiency. Data collection is performed for 5 days from 9 am to 3 pm. Data taken are irradiance, output voltage and current of the solar panel. The data are use to calculate output power and conversion efficiency. The result shows that the highest average output power is 235.96 Watts with conversion efficiency of 78.65% which occurs in day-5.
- 25 August 2025
- Published by Everant Journals in Engineering and Technology Journal
- Vol. 10 (08) , 6409-6411
Open AccessSanding Machine Powered By 2 X 150 WP Solar Panels
The depletion of fossil fuel leads in searching renewable energy source. Solar energy, one of many renewable energy sources, is very suitable to be used in Indonesia. Indonesia has about 200 GW solar energy potential. This solar energy has been converted into electrical energy through solar power plant. However, only limited of those solar power plants powers household appliances. Thus, the present work aims to developed 2 x 150 WP solar power plant for sanding machine. The performance of the panel is evaluated in in terms of output voltage, current, power, and conversion efficiency. Data collection is performed for 5 days from 9 am to 3 pm. Data taken are irradiance, output voltage and current of the solar panel. The data are use to calculate output power and conversion efficiency. The result shows that the highest average output power is 235.96 Watts with conversion efficiency of 78.65% which occurs in day-5.
- Open Access
- 17 January 2025
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 605, 01004
Performance Characteristics of Vortex Wind Turbines with The Computational Fluid Dynamics (CFD) Aided Simulation
The purpose of this paper present research on vortex wind turbines that is referred to as wind turbines without propellers or bladeless. The innovation of the vortex lies in its unique shape and the way it harnesses energy through oscillating motion. The mast column oscillates with the wind, harnessing the von Karman vortices generated as the fluid passes through the column structure. This paper presents the results of computational fluid dynamics (CFD) simulations of a vortex wind turbine with 6 and 7 inch diameter cylinders at various wind speeds. The voltage generated by a vortex wind turbine with a cylinder diameter of 6 inches was measured under realistic conditions to evaluate the wind turbine’s performance in terms of output power generator due to vortex generation. The result of the research show wind speeds as low as 5 m/s that the vortex wind turbines may already exhibit generator-induced oscillations. Vibrations can be obtained using either CFD simulations or measurement results in actual conditions that the vibrations can generate a generator to produce electric voltage.
- 17 January 2025
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 605, 01004
Open AccessPerformance Characteristics of Vortex Wind Turbines with The Computational Fluid Dynamics (CFD) Aided Simulation
The purpose of this paper present research on vortex wind turbines that is referred to as wind turbines without propellers or bladeless. The innovation of the vortex lies in its unique shape and the way it harnesses energy through oscillating motion. The mast column oscillates with the wind, harnessing the von Karman vortices generated as the fluid passes through the column structure. This paper presents the results of computational fluid dynamics (CFD) simulations of a vortex wind turbine with 6 and 7 inch diameter cylinders at various wind speeds. The voltage generated by a vortex wind turbine with a cylinder diameter of 6 inches was measured under realistic conditions to evaluate the wind turbine’s performance in terms of output power generator due to vortex generation. The result of the research show wind speeds as low as 5 m/s that the vortex wind turbines may already exhibit generator-induced oscillations. Vibrations can be obtained using either CFD simulations or measurement results in actual conditions that the vibrations can generate a generator to produce electric voltage.
- Open Access
- 31 October 2022
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 359, 01002
An Effect of Photovoltaic (PV) Arrangement on Performance of Small-scale Solar Energy System
Nowadays, solar energy got increasing attention worldwide. As a matter of fact, in renewable sources, solar power contribution is so high when compared with other sources. The present study aims to figure out an effect of photovoltaic (PV) arrangement on the performance of 150 W and 200 W solar energy conversion system. Three PV configurations, i.e standalone 150 W (model I), 100 W + 50 W (model II), and 3 x 50 W (model III) are tested for the 150 W solar energy system and three other PV configurations, i.e. 150 W + 50 W (model IV), 4 x 50 W (model V), and 2 x 100 W (model VI) are investigated for 200 W solar energy system. The results show that model VI is able to generate an average output power of about 116.44 W which means that the model has an efficiency of 58.22% with respect to the design capacity of the PV.
- 31 October 2022
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 359, 01002
Open AccessAn Effect of Photovoltaic (PV) Arrangement on Performance of Small-scale Solar Energy System
Nowadays, solar energy got increasing attention worldwide. As a matter of fact, in renewable sources, solar power contribution is so high when compared with other sources. The present study aims to figure out an effect of photovoltaic (PV) arrangement on the performance of 150 W and 200 W solar energy conversion system. Three PV configurations, i.e standalone 150 W (model I), 100 W + 50 W (model II), and 3 x 50 W (model III) are tested for the 150 W solar energy system and three other PV configurations, i.e. 150 W + 50 W (model IV), 4 x 50 W (model V), and 2 x 100 W (model VI) are investigated for 200 W solar energy system. The results show that model VI is able to generate an average output power of about 116.44 W which means that the model has an efficiency of 58.22% with respect to the design capacity of the PV.
- Open Access
- 5 December 2021
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 89 (1) , 185-195
The Effect of Compression Ratio on Performance of Generator Set Fuelled with Raw Biogas
In order to utilize a raw biogas as a fuel of generator set (gen-set), it is important to figure out optimum operating parameter of the gen-set, i.e. compression ratio. The present work aims to investigate the effect of compression ratio on performance of 3 kW gen-set fuelled with raw biogas and to obtain optimum compression ratio for operation of the gen-set on raw biogas. The gen-set used in the present work is bi-fuel engine, i.e. fuelled with gasoline or LPG. The performance of the engine fuelled with raw biogas in terms of brake power, brake torque, brake specific fuel consumption, and thermal efficiency is evaluated at compression ratio of 7.5, 8.5, 9.5, and 10.5. The work is carried out under electrical load of 240, 420, and 600 Watt. The result indicates that compression ratio affects the rotational speed, brake power, brake torque, brake specific fuel consumption, and thermal efficiency of the gen-set. Optimum compression ratio for the gen-set fuelled with raw biogas is 9.5. At the optimum compression ratio, maximum brake power, brake torque, and thermal efficiency of are 450.37 W, 1.66 Nm, and 46.93%, respectively. Minimum brake specific fuel is 0.59 kg/kWh at the optimum compression ratio.
- 5 December 2021
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 89 (1) , 185-195
Open AccessThe Effect of Compression Ratio on Performance of Generator Set Fuelled with Raw Biogas
In order to utilize a raw biogas as a fuel of generator set (gen-set), it is important to figure out optimum operating parameter of the gen-set, i.e. compression ratio. The present work aims to investigate the effect of compression ratio on performance of 3 kW gen-set fuelled with raw biogas and to obtain optimum compression ratio for operation of the gen-set on raw biogas. The gen-set used in the present work is bi-fuel engine, i.e. fuelled with gasoline or LPG. The performance of the engine fuelled with raw biogas in terms of brake power, brake torque, brake specific fuel consumption, and thermal efficiency is evaluated at compression ratio of 7.5, 8.5, 9.5, and 10.5. The work is carried out under electrical load of 240, 420, and 600 Watt. The result indicates that compression ratio affects the rotational speed, brake power, brake torque, brake specific fuel consumption, and thermal efficiency of the gen-set. Optimum compression ratio for the gen-set fuelled with raw biogas is 9.5. At the optimum compression ratio, maximum brake power, brake torque, and thermal efficiency of are 450.37 W, 1.66 Nm, and 46.93%, respectively. Minimum brake specific fuel is 0.59 kg/kWh at the optimum compression ratio.
- Open Access
- 10 November 2020
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 202, 11002
Prediction of Aerodynamics Coefficients of Modified NACA 4415 Airfoil Using Computational Fluid Dynamics
The aim of the resent work is to predict the aerodynamic performance of modified NACA 4415 airfoil using computational fluid dynamics modelling. The performance is compared to that of NACA 4415 Standard. The simulation is performed using FLUENT with the variables of freestream velocity (i.e. 3, 4, 5, and 18 m/s) and angle of attacks (i.e. -12°, -10°, -8°, -6°, 0°, 6°, 12°, 14°, 16°, 18°, and 20°). The results indicate that the modified NACA 4415 airfoil has better lift and momentum coefficient. The value of lift coefficient of modified NACA 4415 is relatively higher than NACA 4415, especially at -12° < α <-8° and 12° < α <20°. In addition, the momentum coefficient of the modified NACA 4415 is also higher than the NACA 4415 at -12° < α <20°.
- 10 November 2020
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 202, 11002
Open AccessPrediction of Aerodynamics Coefficients of Modified NACA 4415 Airfoil Using Computational Fluid Dynamics
The aim of the resent work is to predict the aerodynamic performance of modified NACA 4415 airfoil using computational fluid dynamics modelling. The performance is compared to that of NACA 4415 Standard. The simulation is performed using FLUENT with the variables of freestream velocity (i.e. 3, 4, 5, and 18 m/s) and angle of attacks (i.e. -12°, -10°, -8°, -6°, 0°, 6°, 12°, 14°, 16°, 18°, and 20°). The results indicate that the modified NACA 4415 airfoil has better lift and momentum coefficient. The value of lift coefficient of modified NACA 4415 is relatively higher than NACA 4415, especially at -12° < α <-8° and 12° < α <20°. In addition, the momentum coefficient of the modified NACA 4415 is also higher than the NACA 4415 at -12° < α <20°.
- Open Access
- 28 October 2019
- Published by EDP Sciences
- Vol. 125, 25005
Application of Internet of Things (IoT) on air pollution monitoring database system
In the present work, a database system of air pollution monitoring is developed using Internet of Things (IoT) technology. The system aims to give structural information and trace of air pollution level at particular monitoring station. The particular monitoring location (node) is connected to IoT/M2M server via GSM network using GPRS feature and display on IoT/M2M application in web form. The database on IoT/M2M contains name, description, and location of the monitoring station, Pollution index and the time when the data are taken. On IoT/M2M, the data are displayed either in a color bar graph or a line graph. The color indicated the index value of the pollution. The data can be accessed via internet on isfuonline.info. The system is tested at laboratory environment to detect CO, SO2, NO2, O3, and PM. The test result shows that the system is worked well. Time required to transfer the monitoring data to the IoT server is about 15 minutes. Meanwhile, response time of the system is 30 minutes.
- 28 October 2019
- Published by EDP Sciences
- Vol. 125, 25005
Open AccessApplication of Internet of Things (IoT) on air pollution monitoring database system
In the present work, a database system of air pollution monitoring is developed using Internet of Things (IoT) technology. The system aims to give structural information and trace of air pollution level at particular monitoring station. The particular monitoring location (node) is connected to IoT/M2M server via GSM network using GPRS feature and display on IoT/M2M application in web form. The database on IoT/M2M contains name, description, and location of the monitoring station, Pollution index and the time when the data are taken. On IoT/M2M, the data are displayed either in a color bar graph or a line graph. The color indicated the index value of the pollution. The data can be accessed via internet on isfuonline.info. The system is tested at laboratory environment to detect CO, SO2, NO2, O3, and PM. The test result shows that the system is worked well. Time required to transfer the monitoring data to the IoT server is about 15 minutes. Meanwhile, response time of the system is 30 minutes.
- Open Access
- 25 January 2019
- Published by International Journal of Technology in International Journal of Technology
- Vol. 10 (1) , 212-221
Three-dimensional CFD Analysis of Performance of Small-scale Hawt based on Modified NACA-4415 Airfoil
The geometric of a wind turbine rotor is an important parameter in the development of a horizontal axis wind turbine (HAWT). Simulation can be used to determine the rotor’s optimum geometry for specific wind speeds. The present study describes the three-dimensional (3D) computational fluid dynamics (CFD) simulation of a modified small-scale NACA-4415 HAWT rotor in order to predict power output and coefficient, using Blade Element Momentum (BEM) based on Lifting Line Theory (LLT). Power output and coefficient were analysed at wind speeds of 3, 4, 5, 6, and 7 m/s. The results predict that maximum power output increases with increasing wind speed. The predicted minimum power output of 35.41 Watt was obtained at wind speed 3 m/s and Tip Speed Ratio (TSR) 4; the predicted maximum power output was achieved at wind speed 7 m/s and TSR 6. As in the case of power output, power coefficient also improved with rising wind speed, with a coefficient of 0.259 at wind speed 3 m/s and TSR 4 and a coefficient of 0.449 at wind speed 7 m/s and TSR 5. Given Indonesia’s typical wind speed of 4 to 5 m/s, this modified NACA-4415 rotor is predicted to generate between 92 and 255 Watts of power. The power output results show good agreement between simulation and experiment, with an R2 value of 0.93.
- 25 January 2019
- Published by International Journal of Technology in International Journal of Technology
- Vol. 10 (1) , 212-221
Open AccessThree-dimensional CFD Analysis of Performance of Small-scale Hawt based on Modified NACA-4415 Airfoil
The geometric of a wind turbine rotor is an important parameter in the development of a horizontal axis wind turbine (HAWT). Simulation can be used to determine the rotor’s optimum geometry for specific wind speeds. The present study describes the three-dimensional (3D) computational fluid dynamics (CFD) simulation of a modified small-scale NACA-4415 HAWT rotor in order to predict power output and coefficient, using Blade Element Momentum (BEM) based on Lifting Line Theory (LLT). Power output and coefficient were analysed at wind speeds of 3, 4, 5, 6, and 7 m/s. The results predict that maximum power output increases with increasing wind speed. The predicted minimum power output of 35.41 Watt was obtained at wind speed 3 m/s and Tip Speed Ratio (TSR) 4; the predicted maximum power output was achieved at wind speed 7 m/s and TSR 6. As in the case of power output, power coefficient also improved with rising wind speed, with a coefficient of 0.259 at wind speed 3 m/s and TSR 4 and a coefficient of 0.449 at wind speed 7 m/s and TSR 5. Given Indonesia’s typical wind speed of 4 to 5 m/s, this modified NACA-4415 rotor is predicted to generate between 92 and 255 Watts of power. The power output results show good agreement between simulation and experiment, with an R2 value of 0.93.
- Open Access
- 21 December 2018
- Published by EDP Sciences
- Vol. 73, 05025
Performance of AVR microcontroller-SMS gateway system for detecting SO2 and NO2
This study aims to investigate SO2 and NO2 level in atmospheric air using AVR microcontroller-SMS gateway system. This system could gather high-resolution spatiotemporal air pollution data by GSM network of low-cost sensors for monitoring real-time concentrations of different air pollutants, which can be then utilized for a variety of air pollution management tasks. The system able to provide information with threshold values, Good (1-50PPM), Medium (51-100PPM), No Health (101-199PPM), Very Unhealth (200-299PPM) and Dangerous (above 300 PPM). Level of NO2 is higher than NO2 standard. Meanwhile in general, level of SO2 is slightly higher than the standard value. The response time to the SMS communication system averages about 5 seconds depending on signal quality and data traffic from cellular service providers. Differences in Voltage and ADC measurements are caused by several errors, such as ADC ± 2 bit output error, rounding ADC conversion error to volt, or due to errors in the measuring tool used.
- 21 December 2018
- Published by EDP Sciences
- Vol. 73, 05025
Open AccessPerformance of AVR microcontroller-SMS gateway system for detecting SO2 and NO2
This study aims to investigate SO2 and NO2 level in atmospheric air using AVR microcontroller-SMS gateway system. This system could gather high-resolution spatiotemporal air pollution data by GSM network of low-cost sensors for monitoring real-time concentrations of different air pollutants, which can be then utilized for a variety of air pollution management tasks. The system able to provide information with threshold values, Good (1-50PPM), Medium (51-100PPM), No Health (101-199PPM), Very Unhealth (200-299PPM) and Dangerous (above 300 PPM). Level of NO2 is higher than NO2 standard. Meanwhile in general, level of SO2 is slightly higher than the standard value. The response time to the SMS communication system averages about 5 seconds depending on signal quality and data traffic from cellular service providers. Differences in Voltage and ADC measurements are caused by several errors, such as ADC ± 2 bit output error, rounding ADC conversion error to volt, or due to errors in the measuring tool used.
- Open Access
- 3 December 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 434 (1) , 012233
Development of SMS Gateway Information System for Detecting Air Quality
In present work, an SMS gateway information system for detecting CO, O3 and Particulate Matter (PM) is designed and tested. The prototype of the system is developed using an electronic system with sensors of CO, O3, and PM. The data is transmitted to the microcontroller as an electronic control to provide air quality status further. The prototype consists of sensor of MiCS-5524, MiCS-2614, and GP2Y1010AU0F, ATMega 328 Microcontroller, micro SD LCD data logger and modem circuit for SMS gateway based detection information. The test of the system indicates that CO gas is detected using the MiCS-5524 sensor, O3 is measured using sensor MiCS-2614 and PM is detected using GP2Y1010AU0F Sharp sensor. Based on the result of electronic system test, each sensor has output analog voltage that able is read by ADC feature on a microcontroller with the output voltage (Vout) or ADC from sensor proportional to a gas concentration that is around the sensor. This prototype can provide information about air status. The response time to the SMS communication system averages about 5 seconds depending on signal quality and data traffic from cellular service providers.
- 3 December 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 434 (1) , 012233
Open AccessDevelopment of SMS Gateway Information System for Detecting Air Quality
In present work, an SMS gateway information system for detecting CO, O3 and Particulate Matter (PM) is designed and tested. The prototype of the system is developed using an electronic system with sensors of CO, O3, and PM. The data is transmitted to the microcontroller as an electronic control to provide air quality status further. The prototype consists of sensor of MiCS-5524, MiCS-2614, and GP2Y1010AU0F, ATMega 328 Microcontroller, micro SD LCD data logger and modem circuit for SMS gateway based detection information. The test of the system indicates that CO gas is detected using the MiCS-5524 sensor, O3 is measured using sensor MiCS-2614 and PM is detected using GP2Y1010AU0F Sharp sensor. Based on the result of electronic system test, each sensor has output analog voltage that able is read by ADC feature on a microcontroller with the output voltage (Vout) or ADC from sensor proportional to a gas concentration that is around the sensor. This prototype can provide information about air status. The response time to the SMS communication system averages about 5 seconds depending on signal quality and data traffic from cellular service providers.