Youngchul Byun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Youngchul Byun has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Dong Nam Shin
B Environment and Resources Research Group , Research Institute of Industrial Science & Technology , Gwangyang-si , Republic of Korea
2 shared publications- Hyun Su Bak
Particulate Matter Research Center, Research Institute of Industrial Science and Technology (RIST), Gwangyang 57801, Republic of Korea
2 shared publications - Chang-Wan Kim
School of Mechanical Engineering, Konkuk University, Seoul, Republic of Korea
1 shared publication Dong Jun Koh
1 shared publication- Dong Jun Koh
Particulate Matter Research Center, Research Institute of Industrial Science & Technology (RIST), 187-12, Geumho-ro, Gwangyang-si 57801, Jeollanam-do, Korea
1 shared publication - Eunae Kim
Particulate Matter Research Center, Research Institute of Industrial Science & Technology, Geuho-ro, Gwangyang-si 187-12, Jeollanam-do, Korea
1 shared publication
Latest Publications
- Open Access
- 16 March 2024
- Published by MDPI AG in Mathematics
- Vol. 12 (6) , 878
An Interpretable Time Series Forecasting Model for Predicting NOx Emission Concentration in Ferroalloy Electric Arc Furnace Plants
Considering the pivotal role of ferroalloys in the steel industry and the escalating global emphasis on sustainability (e.g., zero emissions and carbon neutrality), the demand for ferroalloys is anticipated to increase. However, the electric arc furnace (EAF) of ferroalloy plants generates substantial amounts of nitrogen oxides (NOx) because of the high-temperature combustion processes. Despite the substantial contributions of many studies on NOx prediction from various industrial facilities, there is a lack of studies considering the environmental condition of the EAF in ferroalloy plants. Therefore, this study presents a deep learning model for predicting NOx emissions from ferroalloy plants and further can provide guidelines for predicting NOx in industrial sites equipped with electric furnaces. In this study, we collected various historical data from the manufacturing execution system of electric furnaces and exhaust gas systems to develop a prediction model. Additionally, an interpretable artificial intelligence method was employed to track the effects of each variable on the NOx emissions. The proposed prediction model can provide decision support to reduce NOx emissions. Furthermore, the interpretation of the model contributes to a better understanding of the factors influencing NOx emissions and the development of effective strategies for emission reduction in ferroalloys EAF plants.
- 16 March 2024
- Published by MDPI AG in Mathematics
- Vol. 12 (6) , 878
Open AccessAn Interpretable Time Series Forecasting Model for Predicting NOx Emission Concentration in Ferroalloy Electric Arc Furnace Plants
Considering the pivotal role of ferroalloys in the steel industry and the escalating global emphasis on sustainability (e.g., zero emissions and carbon neutrality), the demand for ferroalloys is anticipated to increase. However, the electric arc furnace (EAF) of ferroalloy plants generates substantial amounts of nitrogen oxides (NOx) because of the high-temperature combustion processes. Despite the substantial contributions of many studies on NOx prediction from various industrial facilities, there is a lack of studies considering the environmental condition of the EAF in ferroalloy plants. Therefore, this study presents a deep learning model for predicting NOx emissions from ferroalloy plants and further can provide guidelines for predicting NOx in industrial sites equipped with electric furnaces. In this study, we collected various historical data from the manufacturing execution system of electric furnaces and exhaust gas systems to develop a prediction model. Additionally, an interpretable artificial intelligence method was employed to track the effects of each variable on the NOx emissions. The proposed prediction model can provide decision support to reduce NOx emissions. Furthermore, the interpretation of the model contributes to a better understanding of the factors influencing NOx emissions and the development of effective strategies for emission reduction in ferroalloys EAF plants.
- Open Access
- 14 June 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (12) , 7276
Experimental Study on the Operating Parameters of a Pulse-Jet Filter Bag Cleaning System
In this study, the effects of various parameters of the filter bag cleaning system, such as the blow tube size (20A, 40A, 50A), the nozzle diameter (5, 10, 15, 20, 25, 30 mm), the initial tank pressure (0.3, 0.4, 0.5, 0.6, 0.7 MPa), and the pulse duration (50, 100, 150, 200, 250, 300 ms), were evaluated with a view of peak pressure and pressure impulse. This study shows that the peak pressure and pressure impulse are not always in a proportional relationship, since pressure impulse aggregates static pressure and pressure over elapsed time together. For the system investigated, it is found that increasing the blow tube size and pulse duration induce a larger pressure impulse with little change in peak pressure, while higher initial tank pressure enhances both peak pressure and pressure impulse. On the other hand, a larger nozzle diameter was found to increase peak pressure rather than pressure impulse throughout the bag. The experimental results suggest that a higher initial tank pressure is a convenient way to elevate the overall dust-cleaning performance of pulse-jet systems, while other parameters (blow tube size, nozzle diameter, initial tank pressure) can be adopted according to the desired effect for given environment.
- 14 June 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (12) , 7276
Open AccessExperimental Study on the Operating Parameters of a Pulse-Jet Filter Bag Cleaning System
In this study, the effects of various parameters of the filter bag cleaning system, such as the blow tube size (20A, 40A, 50A), the nozzle diameter (5, 10, 15, 20, 25, 30 mm), the initial tank pressure (0.3, 0.4, 0.5, 0.6, 0.7 MPa), and the pulse duration (50, 100, 150, 200, 250, 300 ms), were evaluated with a view of peak pressure and pressure impulse. This study shows that the peak pressure and pressure impulse are not always in a proportional relationship, since pressure impulse aggregates static pressure and pressure over elapsed time together. For the system investigated, it is found that increasing the blow tube size and pulse duration induce a larger pressure impulse with little change in peak pressure, while higher initial tank pressure enhances both peak pressure and pressure impulse. On the other hand, a larger nozzle diameter was found to increase peak pressure rather than pressure impulse throughout the bag. The experimental results suggest that a higher initial tank pressure is a convenient way to elevate the overall dust-cleaning performance of pulse-jet systems, while other parameters (blow tube size, nozzle diameter, initial tank pressure) can be adopted according to the desired effect for given environment.
- 21 May 2019
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 69 (7) , 857-866
Quick vaporization of sprayed sodium hypochlorite (NaClO(aq)) for simultaneous removal of nitrogen oxides (NOx), sulfur dioxide (SO2), and mercury (Hg0)
Sodium hypochlorite (NaClO) has been widely used as a chemical additive for enhancing nitrogen oxide (NOx; NO + NO2), sulfur dioxide (SO2), and mercury (Hg0) removals in a wet scrubber. However, they are each uniquely dependent on NaClO(aq) pH, hence making the simultaneous control difficult. In order to overcome this weakness, we sprayed low liquid-to-gas (L/G) ratio (0.1 L/Nm3) of NaClO(aq) to vaporize quickly at 165 °C. Results have shown that the maximized NOx, SO2, and Hg0 removals can be achieved at the pH range between 4.0 and 6.0. When NOx and Hg0 coexist with SO2, in addition, their removals are significantly enhanced by reactions with solid and gaseous by-products such as NaClO(s), NaClO2(s), OClO, ClO, and Cl species, originated from the reaction between SO2 and NaClO(aq). We have also demonstrated the feasibility of this approach in the real flue gases of a combustion plant and observed 50%, 80%, and 60% of NOx, SO2, and Hg0 removals, respectively. These findings led us to conclude that the spray of NaClO(aq) at a relatively high temperature at which the sprayed solution can vaporize quickly makes the simultaneous control of NOx, SO2, and Hg0 possible. Implications: The simple spray of NaClO(aq) at temperatures above 165 °C can cause the simultaneous removal of gaseous NOx, SO2, and Hg0 by its quick vaporization. Their maximized removals are achieved at the pH range between 4.0 and 6.0. NOx and Hg0 removals are also enhanced by gaseous and solid intermediate products generated from the reaction of SO2 with NaClO(aq). The feasibility of this approach has been demonstrated in the real flue gases of a combustion plant.
- 21 May 2019
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 69 (7) , 857-866
Quick vaporization of sprayed sodium hypochlorite (NaClO(aq)) for simultaneous removal of nitrogen oxides (NOx), sulfur dioxide (SO2), and mercury (Hg0)
Sodium hypochlorite (NaClO) has been widely used as a chemical additive for enhancing nitrogen oxide (NOx; NO + NO2), sulfur dioxide (SO2), and mercury (Hg0) removals in a wet scrubber. However, they are each uniquely dependent on NaClO(aq) pH, hence making the simultaneous control difficult. In order to overcome this weakness, we sprayed low liquid-to-gas (L/G) ratio (0.1 L/Nm3) of NaClO(aq) to vaporize quickly at 165 °C. Results have shown that the maximized NOx, SO2, and Hg0 removals can be achieved at the pH range between 4.0 and 6.0. When NOx and Hg0 coexist with SO2, in addition, their removals are significantly enhanced by reactions with solid and gaseous by-products such as NaClO(s), NaClO2(s), OClO, ClO, and Cl species, originated from the reaction between SO2 and NaClO(aq). We have also demonstrated the feasibility of this approach in the real flue gases of a combustion plant and observed 50%, 80%, and 60% of NOx, SO2, and Hg0 removals, respectively. These findings led us to conclude that the spray of NaClO(aq) at a relatively high temperature at which the sprayed solution can vaporize quickly makes the simultaneous control of NOx, SO2, and Hg0 possible. Implications: The simple spray of NaClO(aq) at temperatures above 165 °C can cause the simultaneous removal of gaseous NOx, SO2, and Hg0 by its quick vaporization. Their maximized removals are achieved at the pH range between 4.0 and 6.0. NOx and Hg0 removals are also enhanced by gaseous and solid intermediate products generated from the reaction of SO2 with NaClO(aq). The feasibility of this approach has been demonstrated in the real flue gases of a combustion plant.
- 1 May 2009
- Published by Elsevier in Chemosphere
- Vol. 75 (6) , 815-818
Effect of hydrogen generated by dielectric barrier discharge of NH3 on selective non-catalytic reduction process
- 1 May 2009
- Published by Elsevier in Chemosphere
- Vol. 75 (6) , 815-818
Effect of hydrogen generated by dielectric barrier discharge of NH3 on selective non-catalytic reduction process