Lorenzo Scheda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lorenzo Scheda has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Carlo Monaco
Department of Biomedical Sciences and Neuromotor, Division of Prosthodontics, Alma Mater Studiorum University of Bologna, Bologna, Italy
4 shared publications - Leonardo Ciocca
Prosthodontic Unit, Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, 40125 Bologna, Italy
3 shared publications Carlo Monaco
Department of Biomedical and Neuromotor Sciences, Alma Mater Studiorum University of Bologna, Bologna, Italy
2 shared publications- Gianpaolo Savio
Department of Civil, Environmental, and Architectural Engineering, University of Padova, Via Venezia, 1, 35131 Padova, Italy
2 shared publications Giovanni Zucchelli
Division of Periodontology, Department of Biomedical and Neuromotor Science, Alma Mater Studiorum University of Bologna, Bologna, Italy
2 shared publicationsPaolo Baldissara
Department of Biomedical and Neuromotor Sciences, Alma Mater Studiorum University of Bologna, Bologna, Italy
2 shared publications
Latest Publications
- 30 April 2019
- Published by Wiley in Journal of Prosthodontics
- Vol. 28 (5) , 556-563
Manufacturing of Metal Frameworks for Full‐Arch Dental Restoration on Implants: A Comparison between Milling and a Novel Hybrid Technology
Purpose: To determine the trueness and precision of frameworks manufactured with a selective laser melting/milling hybrid technique (SLM/m) and conventional milling by comparing the implant‐platform/framework interface with those of the original computer‐aided design (CAD).Materials and Methods: Using a virtual 6‐implant‐supported full‐arch framework CAD drawing, 27 titanium replicas were manufactured by 3 independent manufacturing centers (n = 9/center) using a hybrid SLM/m technology (labs 1 and 2) or the conventional milling technique (lab 3). Using an opto‐mechanical coordinate measuring machine, the frameworks’ misfit distribution and patterns were analyzed, and the position error between paired platform positions within each framework was evaluated to calculate the misfit tendency for each group. A multilevel analysis using a mixed‐effects model was conducted (α = 0.05). The trueness was evaluated as the dimensional difference from the original, while the precision as the dimensional difference from a repeated scan.Results: The 3 dimensional misfits differed significantly among the 3 groups, with the milled group exhibiting the least accurate outcome (p = 0.005). The mean 3D positioning errors ranged from 8 to 16 µm and from 9 to 22 µm for the SLM/m technique (labs 1 and 2, respectively), and from 20 to 35 µm for conventional milling (lab 3). Regarding the misfit distribution pattern, the misfit increased with the distance between paired platform positions in all groups.Conclusions: All groups had 3D misfits well within the error limits reported in the literature. The 3D misfits of new hybrid (SLM/milling) and conventional (milling) procedures differed significantly among them, with the milling technique the less accurate and precise. The largest errors in all groups were found between the most distant implants, resulting in a correlation between the framework span and the inaccuracies.
- 30 April 2019
- Published by Wiley in Journal of Prosthodontics
- Vol. 28 (5) , 556-563
Manufacturing of Metal Frameworks for Full‐Arch Dental Restoration on Implants: A Comparison between Milling and a Novel Hybrid Technology
Purpose: To determine the trueness and precision of frameworks manufactured with a selective laser melting/milling hybrid technique (SLM/m) and conventional milling by comparing the implant‐platform/framework interface with those of the original computer‐aided design (CAD).Materials and Methods: Using a virtual 6‐implant‐supported full‐arch framework CAD drawing, 27 titanium replicas were manufactured by 3 independent manufacturing centers (n = 9/center) using a hybrid SLM/m technology (labs 1 and 2) or the conventional milling technique (lab 3). Using an opto‐mechanical coordinate measuring machine, the frameworks’ misfit distribution and patterns were analyzed, and the position error between paired platform positions within each framework was evaluated to calculate the misfit tendency for each group. A multilevel analysis using a mixed‐effects model was conducted (α = 0.05). The trueness was evaluated as the dimensional difference from the original, while the precision as the dimensional difference from a repeated scan.Results: The 3 dimensional misfits differed significantly among the 3 groups, with the milled group exhibiting the least accurate outcome (p = 0.005). The mean 3D positioning errors ranged from 8 to 16 µm and from 9 to 22 µm for the SLM/m technique (labs 1 and 2, respectively), and from 20 to 35 µm for conventional milling (lab 3). Regarding the misfit distribution pattern, the misfit increased with the distance between paired platform positions in all groups.Conclusions: All groups had 3D misfits well within the error limits reported in the literature. The 3D misfits of new hybrid (SLM/milling) and conventional (milling) procedures differed significantly among them, with the milling technique the less accurate and precise. The largest errors in all groups were found between the most distant implants, resulting in a correlation between the framework span and the inaccuracies.
- 4 April 2019
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 150 (6) , 549-555
Digital bar prototype technique for full-arch rehabilitation on implants
- 4 April 2019
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 150 (6) , 549-555
Digital bar prototype technique for full-arch rehabilitation on implants
- 25 October 2018
- Published by Wiley in Journal of Prosthodontics
- Vol. 28 (5) , 536-540
Implant Digital Impression in the Esthetic Area
The aim of this report is to describe two standardized protocols for digital impression when implant support rehabilitation is used in the esthetic area. The two techniques were used to transfer all provisional crown parameters to definitive restorations in different clinical scenarios. In the direct technique, an impression (STL1) is made of the provisional restorations attached to the implants, with surrounding gingival tissue. The second scan (STL2) captures the sulcular aspect of the peri‐implant soft tissue immediately after removal of the provisional restoration. The last impression (STL3) of the complete arch is made with a standardized scanbody attached to the implant to capture the 3D location of the implant. The direct technique is indicated when the peri‐implant soft tissues are stable upon removal of the provisional restoration. The indirect technique is used when the gingival tissue collapses rapidly after the removal of the provisional crown. The impressions of the provisional restoration and the position of the implant are similar to those obtained with the direct technique, and the shape of the peri‐implant tissue is extrapolated from the negative shape obtained from making the digital impression when the provisional restoration is taken out of the mouth. Finally, in both techniques the 3 scans are superimposed to obtain a file, which contains the details of the peri‐implant soft tissue. The direct and indirect digital techniques allowed realization of a predictable definitive restoration in the esthetic zone in different clinical scenarios, reducing the duration of clinical procedures.
- 25 October 2018
- Published by Wiley in Journal of Prosthodontics
- Vol. 28 (5) , 536-540
Implant Digital Impression in the Esthetic Area
The aim of this report is to describe two standardized protocols for digital impression when implant support rehabilitation is used in the esthetic area. The two techniques were used to transfer all provisional crown parameters to definitive restorations in different clinical scenarios. In the direct technique, an impression (STL1) is made of the provisional restorations attached to the implants, with surrounding gingival tissue. The second scan (STL2) captures the sulcular aspect of the peri‐implant soft tissue immediately after removal of the provisional restoration. The last impression (STL3) of the complete arch is made with a standardized scanbody attached to the implant to capture the 3D location of the implant. The direct technique is indicated when the peri‐implant soft tissues are stable upon removal of the provisional restoration. The indirect technique is used when the gingival tissue collapses rapidly after the removal of the provisional crown. The impressions of the provisional restoration and the position of the implant are similar to those obtained with the direct technique, and the shape of the peri‐implant tissue is extrapolated from the negative shape obtained from making the digital impression when the provisional restoration is taken out of the mouth. Finally, in both techniques the 3 scans are superimposed to obtain a file, which contains the details of the peri‐implant soft tissue. The direct and indirect digital techniques allowed realization of a predictable definitive restoration in the esthetic zone in different clinical scenarios, reducing the duration of clinical procedures.
- 1 October 2018
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 149 (10) , 918-923
The prototype concept in a full digital implant workflow
- 1 October 2018
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 149 (10) , 918-923
The prototype concept in a full digital implant workflow
- 1 July 2018
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 62 (3) , 383-385
A fully digital approach to replicate functional and aesthetic parameters in implant-supported full-arch rehabilitation
The aim of this technical procedure was to use a fully digital technique (FDT) for full-arch implant support rehabilitation. The FDT was used to transfer the provisional restoration parameters to definitive restorations using intraoral scanners. Three sets of digital impressions were obtained. Through the first set, standard tessellation language 1 (STL1), provisional restorations screwed to implants and the surrounding gingival tissue was captured. STL2 consisted of intraoral scans of standardized scanbodies screwed to implants to collect 3D positioning data of implants. STL3 included the digital impression of provisional restoration out of the mouth in order to capture the gingival architecture and the peri-implant soft tissue that was not possible to transfer with the previous impressions. STL1, STL2, and STL3 were combined using computer-aided design (CAD) functions into a single file, STL4. Thus, STL4 contained information on the 3D implant positions, soft tissue architectures, occlusal relationships, correct occlusal vertical dimension and aesthetic features. Using STL4, the master models with implant analogues were 3D printed. Computer-aided design and computer-aided manufacturing milled (CAD/CAM-milled) aluminium bars and a resin prototype were produced to test the accuracy and the functional and aesthetic parameters. Titanium frameworks were digitally designed using STL4, milled using CAD/CAM, and finalized with pink resin and resin teeth. The FDT provided an effective fully digital protocol to capture all information for provisional full-arch implant restorations using an intraoral scanner and transfer that information to definitive restorations.
- 1 July 2018
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 62 (3) , 383-385
A fully digital approach to replicate functional and aesthetic parameters in implant-supported full-arch rehabilitation
The aim of this technical procedure was to use a fully digital technique (FDT) for full-arch implant support rehabilitation. The FDT was used to transfer the provisional restoration parameters to definitive restorations using intraoral scanners. Three sets of digital impressions were obtained. Through the first set, standard tessellation language 1 (STL1), provisional restorations screwed to implants and the surrounding gingival tissue was captured. STL2 consisted of intraoral scans of standardized scanbodies screwed to implants to collect 3D positioning data of implants. STL3 included the digital impression of provisional restoration out of the mouth in order to capture the gingival architecture and the peri-implant soft tissue that was not possible to transfer with the previous impressions. STL1, STL2, and STL3 were combined using computer-aided design (CAD) functions into a single file, STL4. Thus, STL4 contained information on the 3D implant positions, soft tissue architectures, occlusal relationships, correct occlusal vertical dimension and aesthetic features. Using STL4, the master models with implant analogues were 3D printed. Computer-aided design and computer-aided manufacturing milled (CAD/CAM-milled) aluminium bars and a resin prototype were produced to test the accuracy and the functional and aesthetic parameters. Titanium frameworks were digitally designed using STL4, milled using CAD/CAM, and finalized with pink resin and resin teeth. The FDT provided an effective fully digital protocol to capture all information for provisional full-arch implant restorations using an intraoral scanner and transfer that information to definitive restorations.
- 2 March 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (7) , 1097-1108
In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants
This study describes a method for measuring the accuracy of the virtual impression.
- 2 March 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (7) , 1097-1108
In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants
This study describes a method for measuring the accuracy of the virtual impression.