SKSvetlana M. Krylova

Svetlana M. Krylova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Svetlana M. Krylova has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Fundamental Source of Misclassification in Single-Concentration Binding Screens

    by Tong Ye Wang, Toby Chan, Svetlana M. Krylova, Sergey N. Krylov

    High-throughput screening of large compound libraries is central to drug discovery and chemical probe development. Primary screens typically test each compound at a single concentration and classify hits according to whether the measured signal crosses a preset threshold. Only hits advance to multiconcentration assays for binding-isotherm construction and determination of equilibrium dissociation constants, Kd. Incorrect hit calling is usually attributed to chemistry-specific nuisance behavior, platform-dependent artifacts, screening concentration, and threshold selection. Here, we identify an additional fundamental vulnerability in single-concentration binding screens. First-principles analysis shows that when the reported compound–target signal is nonadditive, meaning that the mixture signal cannot be expressed as a weighted sum of free-target and bound-complex signals, small errors in nominal compound and target concentrations can be amplified into large errors in the single-point readout used for hit calling. Nonadditivity can arise from nonlinear signal formation during measurement or nonlinear transformations during postacquisition processing. Controlled end-to-end simulations, in which true Kd values and signal transformations are known, map the operating regimes where this amplification is most severe. The resulting distortions can produce irreversible false negatives because missed binders do not advance to secondary characterization; in some regimes, true high-affinity binders are preferentially penalized. We translate these findings into a practical workflow emphasizing definition of the desired Kd range, ligand-excess design when feasible, concentration control, end-to-end testing of readout additivity and monotonicity, and pilot- or simulation-based assessment of hit-misclassification risk.

  • Open Access

    A Widely Used CRP Aptamer Does Not Bind CRP, Revealing a General Route to Surface-Driven Pseudoaffinity in Biosensors

    by Quan Duc Le, An Thi Hoai Le, Tong Ye Wang, Svetlana M. Krylova, Noah A. Clark, David Seghetti-Hebble, Ken-Ichiro Matsunaga, Michiko Kimoto, Ichiro Hirao, Sergey N. Krylov

    Aptamer sequences are often reused in biosensors and diagnostics without independent confirmation of binding activity, even though rigorous validation requires quantitative solution-phase testing by orthogonal methods. Here, we re-examined a DNA sequence reported in 2010 to bind C-reactive protein (CRP) with a Kd of 3.5 nM by surface plasmon resonance (SPR) and subsequently adopted in many CRP aptasensors. We tested this sequence by two orthogonal solution-phase methods and SPR. In solution-phase assays, we found no detectable binding of the reported aptamer to native CRP. In SPR, we found that CRP binds strongly to streptavidin-containing sensor surfaces even in the absence of immobilized DNA, whereas the reported sequence produced no measurable ligand-specific SPR response under lower-background capture conditions. Thus, the originally reported affinity is best explained by surface-driven pseudoaffinity rather than true aptamer-CRP recognition. More broadly, this case reveals a general route by which nonbinding aptamers can acquire apparent affinity through surface-driven pseudoaffinity and then be propagated through the biosensor literature as validated molecular recognition reagents. The study underscores the need for orthogonal solution-phase validation before aptamers are reused in biosensor development and related analytical applications.

  • A Roadmap for Reliable Determination of Aptamer−Target Equilibrium Dissociation Constants ( K d )

    by An T. H. Le, Svetlana M. Krylova, Sergey N. Krylov

    Many published aptamer sequences selected and characterized by surface-based methods fail to show quantifiable binding in solution, indicating that their true equilibrium dissociation constants (Kd) are far higher than those originally reported. This discrepancy raises fundamental concerns about the reliability of quantitative binding studies that underpin the aptamer field. Surface-based assays enable high-throughput screening but are prone to non-specific binding that can be mistaken for true molecular recognition. Therefore, reliable Kd determination should be anchored in solution-based techniques that avoid such artifacts. A growing consensus also holds that Kd values should be verified by at least two orthogonal methods, since these constants are not measured directly but are inferred from quantitative observables in the absence of reference standards. Here, we compare the principal solution-based approaches for aptamer interactions with small-molecule and protein targets, focusing on quantitative accuracy, universality, material requirements, and feasibility. This analysis proposes a best-practice roadmap for method selection, aiming to reduce experimental workload while supporting defensible Kd determination through orthogonal confirmation. We hope this roadmap encourages community discussion and convergence toward shared practices for solution-based Kd determination.


  • Open Access

    Introducing Quantitative Assessment of Michaelis Constant ( K m ) Accuracy

    by Tong Ye Wang, Parmeetpal Dhillon, Svetlana M. Krylova, Amit Bijlani, Sebastian Schreiber, Dasantila Golemi‐Kotra, Joachim Jose, Sergey N. Krylov

    The Michaelis constant ( K m ) is central to enzyme kinetics, guiding variant selection, inhibitor screening, and metabolic modeling. However, K m obtained by nonlinear regression can be substantially inaccurate even when the reported standard error (SE) appears small. Common software reports SE but provides no accuracy metric. This gap is addressed by extending the accuracy confidence interval (ACI) framework to K m (ACI‐ K m ) through a binding‐isotherm formulation of the velocity–substrate fit. Given confidence intervals for concentration accuracy, the method quantifies how residual systematic uncertainties in enzyme and substrate concentrations ( E 0 and S 0 ) propagate into the determined K m values and provides a probabilistic interval expected to enclose the accurate value. The approach requires no additional kinetic experiments and is directly applicable to existing datasets. Concentration‐accuracy intervals can be estimated from calibration data, reagent specifications, or quality‐control records. ACI‐ K m is valid across a wide range of E 0 / K m conditions, including relatively high E 0 . A free web application ( https://aci.sci.yorku.ca ) implements ACI‐ K m . Tests on synthetic and experimental datasets show that K m ± SE can severely underestimate uncertainty, whereas ACI provides more reliable accuracy bounds for decision‐making, complementing rather than replacing traditional precision metrics by providing quantitative diagnostic bounds for concentration‐related uncertainties in K m determination.


  • Nonequilibrium Capillary Electrophoresis of Equilibrium Mixtures (NECEEM)-Enabled Mechanistic Analysis of Cooperative Binding: Application to C-Reactive Protein–SOMAmer Complexes

    by Quan Duc Le, An T. H. Le, Tong Ye Wang, Svetlana M. Krylova, Sergey N. Krylov

    Understanding cooperative binding is essential for characterizing interactions between multimeric proteins and their ligands, because biological function often depends on binding stoichiometry or allosteric regulation. Detailed characterization of cooperativity, in turn, requires determination of the equilibrium dissociation constants for each binding step (Kd1, Kd2,...). However, most experimental methods rely on ensemble-averaged signals that cannot resolve coexisting complexes, forcing stepwise constants to be inferred from model-dependent fits that cannot be validated with ensemble data alone. To date, direct (model-independent) determinations of these constants have been reported only with spectral-resolution techniques such as native MS and slow-exchange NMR; no physical-separation method has yet delivered Kd1, Kd2, etc. Here, we present a nonequilibrium capillary electrophoresis of equilibrium mixtures (NECEEM)-based approach that physically resolves and quantifies stoichiometric complexes formed at equilibrium. A protein and its ligand are pre-equilibrated in solution, and the resulting complexes of different stoichiometries are separated from one another and from free ligand according to their electrophoretic mobilities. Quantitative peak analysis yields the equilibrium fractions of each species, providing step-resolved thermodynamic data from which individual Kd values are obtained directly, without global model fitting; their relative magnitudes reveal the presence and extent of cooperativity. As proof of concept, we studied the interaction between C-reactive protein (CRP), a homopentameric acute-phase protein of the innate immune system, and a slow off-rate modified aptamer (SOMAmer). The electropherograms resolved and quantified free ligand as well as 1:1 and 2:1 SOMAmer-CRP complexes, allowing determination of the 95% accuracy confidence intervals (ACI) for the first two dissociation constants: Kd1 = 3.0-7.8 nM and Kd2 = 41-160 nM, consistent with strong negative cooperativity. At high ligand-to-target ratios, 3:1 SOMAmer-CRP complex was also detected, but its peak could not be baseline-resolved, precluding reliable determination of Kd3. This study establishes NECEEM as the first solution-phase physical-separation method capable of directly quantifying stepwise affinities and dissecting cooperativity in multivalent systems.


  • Open Access

    A policy roadmap for sustainable mass-testing

    by Sergey N Krylov, Svetlana M Krylova, An T H Le, Seyed M Moghadas, Amin Mawani, Nima Tabatabaei, Manos Papagelis, Peter Tsasis, Mary E Wiktorowicz, R Shayna Rosenbaum

    Population-wide mass testing with affordable self-tests can drastically reduce lives lost and minimize economic and societal costs during pandemics, especially if deployed before vaccines. During COVID-19, however, the development of self-test manufacturing and distribution capacity lagged behind vaccine rollout and was dismantled once surges subsided, returning us to a pre-pandemic state. As no new capacity has since been secured, future mass testing would again face costly delays. To mitigate this risk, we propose a policy roadmap for an economically viable mass-testing system that can be sustained between crises and rapidly scaled during emergencies. Public investment in R&D to improve the sensitivity of affordable self-tests—not to achieve a single benchmark, but to advance point-of-need (PoN) technologies across medical and non-medical applications—is essential. Improved sensitivity would enable new uses in routine health screening, food safety, and environmental monitoring, generating steady demand and production capacity that can expand as needed. This demand would support a robust system anchored by four mutually reinforcing pillars: scalable manufacturing, real-time data infrastructure, predictive analytics, and sustainable financing. Prioritizing sensitivity can transform mass testing from a reactive measure into a durable public health foundation.


  • Addressing Hemolysis-Induced Loss of Sensitivity in Lateral Flow Assays of Blood Samples with Platinum-Coated Gold Nanoparticles and Machine Learning

    by Xingzhi Che, An T. H. Le, Maria Orlando, Svetlana M. Krylova, Vasily G. Panferov, Nikita A. Ivanov, Erez Freud, R. Shayna Rosenbaum, Sergey N. Krylov

    Gold nanoparticles (GNPs), which appear red, are widely used as labels in lateral flow assays (LFAs) for visual detection. However, in blood-derived samples, hemolysis─caused by the rupture of red blood cells and the release of hemoglobin─creates a red-colored background that obscures the test line, significantly raising the limit of detection (LOD) and reducing the diagnostic sensitivity of LFAs. The degree of hemolysis can vary across samples due to differences in blood collection techniques, such as varying finger prick pressure, leading to inconsistent sensitivity. A practical solution to hemolysis-induced sensitivity loss should be easy for LFA manufacturers to implement without complicating the assay's use. We propose modifying the color of GNPs from red to black by coating the nanoparticles with platinum, creating a platinum shell around a gold core (GNPs@Pt). This simple and cost-effective modification produces black nanoparticles, enhancing the contrast between the test line and background in hemolyzed samples. Using manual threshold-based image analysis, (scanning test strips and calculating the signal-to-noise ratio as a reference technique), we found that GNPs@Pt improved the LOD in LFAs of hemolyzed samples, with greater relative improvements observed at higher levels of hemolysis. In experiments assessing visual detection by human subjects, GNPs@Pt significantly outperformed standard GNPs; however, human accuracy in recognizing the test line was consistently lower than that achieved with threshold-based image analysis. To address the impracticality of manual threshold-based image analysis and the unreliability of visual detection, we developed a machine learning (ML) model for analyzing images of the LFA test strips. The integration of GNPs@Pt with ML-based image analysis achieved an assay LOD performance comparable to manual threshold-based image analysis, demonstrating 100% sensitivity and 100% specificity when benchmarked against the latter as a reference standard. Given the ease of substituting GNPs with GNPs@Pt, we recommend adopting this modification for assays involving blood samples. Additionally, we advocate using ML models, which can be integrated into mobile applications, as a standard readout tool for LFAs.


  • Single-Reservoir Electrophoresis to Facilitate Layer-by-Layer Assembly of Gold Nanoparticles in Lateral Flow Immunoassay

    by Xingzhi Che, Nikita Ivanov, Svetlana M. Krylova, Sergey N. Krylov

    Electrophoretically facilitated layer-by-layer assembly of gold nanoparticles (GNPs) in lateral flow immunoassays (LFIAs) significantly enhances the signal-to-background ratio and, consequently, the diagnostic sensitivity of these tests. However, conventional two-reservoir electrophoresis on paper is limited by counterflow induced by capillary action, which disrupts the electrophoretic migration of GNPs toward the anode. This counterflow necessitates manual intervention to facilitate the movement of GNP-labeled immunocomplexes from the membrane to the absorption pad, complicating the assay workflow. To address this challenge, we propose a nonconventional single-reservoir electrophoresis system on paper, which inherently eliminates counterflow. In this configuration, the loading side of the paper strip and the cathode reside within the buffer reservoir, while the anode is directly affixed to the opposite end of the paper strip. We demonstrate the efficacy of this single-reservoir system in driving layer-by-layer assembly, while presenting favorable spatial temperature profiles as a side benefit. By eliminating the need for manual steps, this design streamlines the electrophoresis process and enhances the usability of electrophoretically facilitated LFIA assays.


  • Open Access

    Quantitative Characterization of Partitioning Stringency in SELEX

    by An T. H. Le, Eden Teclemichael, Svetlana M. Krylova, Sergey N. Krylov

    Maintaining stringent conditions in SELEX (Systematic Evolution of Ligands by EXponential enrichment) is crucial for obtaining high-affinity aptamers. However, excessive stringency greatly increases the risk of SELEX failure. Controlling stringency has remained a technical challenge, largely dependent on intuition, due to the absence of a clear, quantitative measure of stringency. This study was motivated by our insight that, while stringency is influenced by multiple factors, it can be quantified by its effect: increasing stringency reduces the quantity of binders normalized to that of nonbinders after partitioning. Based on this insight, we propose measuring stringency using the binder-to-nonbinder ratio (BNR), where a lower BNR indicates higher stringency. We derive an experimental method for determining BNR via quantitative PCR. Our theoretical analysis and SELEX experiments using two distinct proteins as selection targets underscore the importance of maintaining a BNR significantly greater than zero to avoid failure, a principle we call the SELEX nonfailure criterion. By employing inverse BNR to quantify stringency and applying this criterion, researchers can more rationally control SELEX progress. The quantitative stringency measure and nonfailure criterion can also be applied to other artificial evolution methods, provided that selected binders are quantifiable.


  • Open Access

    A Practical Approach to Quantitatively Assessing Equilibrium-Constant Accuracy from a Single Binding Isotherm

    by Tong Ye Wang, Jessica Latimer, Jean-Luc Rukundo, Isaac Kogan, Svetlana M. Krylova, Sebastian Schreiber, Philip Kohlmann, Joachim Jose, Sergey N. Krylov

    Equilibrium constants are essential for understanding and predicting the behavior of chemical systems across various scientific disciplines. Traditionally, these constants are computed via nonlinear regression of reaction isotherms, which show the dependence of the unreacted fraction of one reactant on the total concentration of another reactant. However, while these equilibrium constants can be precise (with small random errors), they may also be grossly inaccurate (with large systematic errors), leading to potential misinterpretations. Although some statistical methods exist for assessing the accuracy of nonlinear regression, their limited practicality for molecular scientists has resulted in their neglect by this research community. The objective of this work is to develop a practical method for quantitatively assessing the accuracy of equilibrium constants that could be easily understood and immediately adopted by researchers routinely determining these constants. Our approach integrates error-propagation and regression-stability analyses to establish the accuracy confidence interval (ACI)-a range within which the true value of the computed parameter lies with a defined probability. In a proof-of-principle study, we applied this approach to develop a workflow for determining the ACI of the equilibrium dissociation constant (K d) of affinity complexes from a single binding isotherm. We clearly explained how the input parameters for this workflow can be determined, and finally, we have implemented this workflow in a user-friendly web application (https://aci.sci.yorku.ca) to facilitate its immediate adoption by molecular scientists, regardless of their mathematical and computer proficiency. We further conducted three case studies exemplifying the use of the ACI in the context of simultaneous assessment of precision and accuracy of determined K d values. By understanding the ACI of equilibrium constants and other parameters computed through nonlinear regression, researchers can avoid misconceptions that arise from relying solely on precision.